WEG CFW11 Brochure 50019076 en
WEG CFW11 Brochure 50019076 en
WEG CFW11 Brochure 50019076 en
SPEED DRIVE
High productivity and performance
for your business
Table of Contents
Introduction 04
Benefits 05
Human-Machine Interface 08
Resources 12
Applications 14
Coding 16
Specifications 18
Accessories 24
Optional Items 28
Block Diagram 31
Technical Data 33
www.weg.net
Power Ranges1)
J 1.5 to 2.2 kW - 2 to 3 HP / 200-240 V ac - Single-phase J 1.5 to 560 kW - 2 to 850 HP / 500-600 V ac - Three-phase
J 1.1 to 55 kW - 2 to 75 HP / 200-240 V ac - Three-phase J 2.2 to 630 kW - 3 to 850 HP / 600-690 V ac - Three-phase
J 1.5 to 630 kW - 2 to 970 HP / 380-480 V ac - Three-phase
J 150% for 3 seconds every 10 minutes J 200% for 3 seconds every 10 minutes
Certifications
Note: for higher powers, contact WEG Automation or refer to the AFW11M catalog (Drive with Modular Variable Speed Drive).
Benefits
Innovative and Easy to Use
The CFW11 has many useful and convenient functions for the customers, especially because of its simple installation
and operation. The CFW11 has been designed based on the plug-and-play technology, which allows a simple and
quick installation of the inverter and its accessories. The HMI has a navigation and programming system with soft
keys. You can access the parameters sequentially or through parameter groups.
The HMI also offers the oriented start-up function that guides the user along the programming.
Flexibility
The CFW11 is adaptable to the customer’s needs through a wide range of easy-to-install accessories. In
addition, the standard version comes with SoftPLC, allowing the customers to create their own applications
using the WLP (Ladder Programming) software application.
Connectivity
Communication protocols: Modbus-RTU, Modbus-TCP, Profibus-DP-V1, DeviceNet, CANopen, EtherNet/IP,
EtherCAT, PROFINET-IO and BACnet.
J VVW - Voltage Vector WEG - voltage vector control: motor speed control with automatic adjustment to the load and grid
variations
J Vector sensorless (without encoder) - induction motors: vector torque and speed control with excellent dynamic response,
position and speed control with excellent accuracy and dynamic response over the entire speed range (even when the motor
is stopped)
J Vector WMagnet sensorless (without encoder) and with encoder: vector control with excellent dynamic response for WEG
Optimal Flux®
J Technology for motors driven by variable speed drive in applications with constant torque characteristics
J Rated torque at low speeds, eliminating the need for forced ventilation or motor oversizing
J Improved motor and inverter set performance (an exclusive WEG solution)
J The Optimal Flux function works when the high efficiency WEG motor + CFW11 configuration is used
Keypad
The keypad of the CFW11 has been developed to make the interaction with the user simple and fast, providing excellent visibility.
Interface Tools
J Graphic display with backlight
J Copy Function
J Language selection
Left soft key: function defined by the Keys to scroll the menus and
parameters and to change the
text on the display
content of the parameters
JOG key
Remote Keypad
The standard keypad is detachable and can be
installed on panel doors or machine consoles
with IP56 protection rating.
The HMI can be configured to display up to four variables simultaneously, in three different modes.
Status Indication
J Run J Auto-tuning
J Ready J Last alarm
J Configuration J Inverter disabled by fault and fault number
Local/Remote Indication
Basic Application
The Basic Application parameter group contains the basic parameters,
whose settings are required in most applications.
Fault History
It displays the parameters with the last ten faults, informing the
day, month, year and hour of the events.
Reading Parameters
It displays only the inverter
monitoring parameters.
Speed reference
Trend Function
J Parameter/variable online graphic monitoring
Trace Function
J It registers the CFW11 variables with activation by events
USB connection
Friendly environment
Resources
Safety Stop Function - Safe Torque Off (STO)
Enabling the safety stop function assures to stop the driven motor and/or prevents it from being accidentally started which
could be an important component of a machine and process safety system.
The STO function can be used in category 3 / PL d applications according to the EN ISO13849-1 standard and SIL 2
according to the IEC62061 and IEC61508 standards.
This is an optional feature and available in versions with the STO function.
L1
R U
V M
S
W 3~
T
L2
Dynamic Braking
Braking IGBT (chopper) can be offered built-in or with external module (DBW03/DBW04).
Conformal Coating
Application of a special varnish on the CFW11 electronic
boards to extend the service life, protecting against dust,
moisture and corrosive chemicals.
Class 3C2 protection is standard for the entire CFW11 line
and in compliance with IEC 60721-3-3. Also available in the
Extra-Coating version, class 3C3, as an optional item.
Single DC Busbar
Usually used in multimotor systems, this configuration is a great solution for energy savings and reduced installation costs,
since the individual rectifier bridges of the inverters are replaced by a single rectifier bridge. Each variable speed drive is then
fed with direct current through its DC power terminals.
This solution allows the power on the DC link to be shared by the inverters connected to it, thus optimizing the energy
consumption.
Standard frames A to E and H of the CFW11 in the standard version and sizes F and G in the special hardware version (DC)
can be connected to a DC bus system (refer to the User’s Manual for further information).
General input
rectifier unit
CFW11
1 2 3 4 n
Note: a pre-charge circuit must be added to each of the variable speed drive.
cleaning or replacement
Operating Temperature
Ambient temperature up to 60 °C for
frames A to D (except IP55 models) and up
to 55 °C for frames E, F, G and H, with
current derating (refer to the User’s
Manual).
Applications
Thanks to its wide range of functions, high overload capacity, easy setup, installation and operation, in addition to offering the
panel-mounted versions (AFW11, APW11 and modular AFW11M/W), the CFW11 is the ideal variable speed drive for different
applications, in different industry sectors.
Pulp and Paper Wood Cement and Mining Chemicals and Petrochemical
The CFW11 has also been developed for applications where safety is an essential requirement, because, in addition to the
built-in protections and alarms, it has a safety stop function according to EN ISO 13849-1 and IEC 62061/IEC 61508 and
TÜV Rheiland certification.
Coding1)
T Three-phase N1 NEMA1
55 IP55
4 - Voltage
Frame Degree of protection Special DC hardware
200-240 V: for frames A, B, C and D
2
220-230 V: for frame E and F A IP21 No
4 380-480 V B IP21 No
5 500-600 V C IP21 No
6 660-690 V D NEMA1 / IP20 No
E IP20 No
5 - Optional accessories
IP20 No
S Factory default model F
IP00 Yes
O Product with optional items
IP20 No
G
IP00 Yes
H IP20 No
O No operating interface (HMI) - with blank cover Y Built-in STO module included. 500-690 V any size: built-in
Frames A, B, C and D: Built-in brake IGBT. Frames E, F and G: Blank Factory default model
200-480 V
Brake IGBT not incorporated.
W With external power supply of the electronics at 24 V dc
Frame B: Built-in brake IGBT.
Frames F and G: Brake IGBT not incorporated
Blank 500-600 V (use DBW03 - see accessories). 12 - Special hardware
Frame H: Brake IGBT not incorporated
(use DBW04 - see accessories). Blank Factory default model
Frames D and E: Built-in brake IGBT. H Special hardware included
500-690 V
Frames F and G: Brake IGBT not incorporated.
200-480 V Frame E: Built-in brake IGBT. DC Power supply via DC link (without rectifier bridge)
DB Frames D and E: Brake IGBT already built-in DS With built-in switch disconnector (IP55 models only)
500-690 V
(no need to include “DB” in the smart code).
500-690 V Brake IGBT not included in frames B, C, D and E. 13 - Special software
NB
200-480 V Frames A, B, C, D and E: not available without brake IGBT.
Blank Factory default model
9 - RFI filter Sx Special software included
Specification
IP2x version
Maximum applicable motor1)
CFW11 variable speed drive
Normal duty (ND) Heavy duty (HD)
IEC UL IEC UL
Rated output current
Frame Braking 50 Hz 60 Hz 60 Hz 50 Hz 60 Hz 60 Hz
(A)
Reference Power supply (V)
size IGBT 230 V ac 220 V ac 230 V ac 230 V ac 220 V ac 230 V ac
ND HD kW HP HP kW HP HP
CFW110006B2SZ Single-phase or 200-240 6.0 5.0 1.5 2.0 1.5 1.1 1.5 1.0
A
CFW110007B2SZ three-phase V ac 7.0 7.0 1.5 2.0 2.0 1.5 2.0 2.0
CFW110054T2SZ 200-240 C 54 45 15 20 20 11 15 15
Three-phase
V ac
CFW110070T2SZ 70 56 22 25 25 15 20 20
CFW110086T2SZ 86 70 22 30 30 22 25 25
D
CFW110105T2SZ 105 86 30 40 40 22 30 30
Notes: 1) Motor powers are referential values valid for WEG W22 IE2 three-phase, 4-pole, 50 or 60 Hz induction motors. The proper size must be determined
according to the motor rated current, which must be lower than or equal to the inverter rated output current.
ND = Normal Duty (normal overload = 110% of the rated current for one minute or 150% of the rated current for 3 seconds; one overload every 10 minutes).
HD = Heavy Duty (heavy overload = 150% of the rated current for one minute or 200% of the rated current for 3 seconds; one overload every 10 minutes).
IP2x version
Maximum applicable motor1)
CFW11 variable speed drive
Normal duty (ND) Heavy duty (HD)
ND HD kW HP kW HP HP kW HP kW HP HP
CFW110003T4SZ 3.6 3.6 1.5 2.0 1.5 2.0 2.0 1.5 2.0 1.5 2.0 2.0
CFW110005T4SZ 5.0 5.0 2.2 3.0 2.2 3.0 3.0 2.2 3.0 2.2 3.0 3.0
CFW110007T4SZ A 7.0 5.5 3.0 4.0 3.0 5.0 3.0 2.2 3.0 2.2 3.0 3.0
CFW110010T4SZ 10 10 4.5 6.0 4.0 7.5 5.0 4.5 6.0 4.0 7.5 5.0
CFW110013T4SZ 13.5 11 5.5 7.5 5.5 10 7.5 4.5 6.0 5.5 7.5 7.5
CFW110031T4SZ 31 25 15 20 15 25 20 11 15 11 20 15
CFW110058T4SZ 58.5 47 30 40 30 50 40 22 30 22 30 30
CFW110070T4SZ 70.5 61 37 50 37 60 50 30 40 30 50 40
D
CFW110088T4SZ 88 73 45 60 45 75 60 37 50 37 60 50
CFW110105T4ODBZ 105 88 55 75 55 75 75 45 60 45 75 60
CFW110211T4SZ 211 180 110 150 110 180 150 90 125 90 150 150
CFW110242T4SZ 242 211 110 150 132 200 200 110 150 110 150 150
CFW110312T4SZ 312 242 150 200 160 270 250 110 150 132 200 200
F
CFW110370T4SZ 370 312 200 270 200 300 300 150 200 160 250 250
Not
CFW110477T4SZ built-in; use 477 370 260 350 260 350 400 200 270 200 300 300
external
CFW110515T4SZ accessory 515 477 260 350 300 450 400 220 300 280 400 400
DBW03
CFW110601T4SZ 601 515 300 400 355 500 500 260 350 300 450 400
G
CFW110720T4SZ 720 560 370 500 400 610 600 300 400 315 500 400
CFW110760T4SZ 760 600 400 550 450 680 600 300 400 330 550 500
CFW110795T4SZ 795 637 400 550 450 680 600 330 450 355 550 500
Not
CFW110877T4SZ built-in; use 877 715 480 650 500 750 700 370 500 400 610 500
H external
CFW111062T4SZ accessory 1,062 855 560 750 560 850 900 440 600 500 750 700
DBW04
CFW111141T4SZ 1,141 943 590 800 630 970 1,000 515 700 560 750 800
Notes: 1) Motor powers are referential values valid for WEG W22 IE2 or HGF three-phase, 4-pole, 50 or 60 Hz induction motors. The proper size must be determined
according to the motor rated current, which must be lower than or equal to the inverter rated output current.
ND = Normal Duty (normal overload = 110% of the rated current for one minute or 150% of the rated current for 3 seconds; one overload every 10 minutes).
HD = Heavy Duty (heavy overload = 150% of the rated current for one minute or 200% of the rated current for 3 seconds; one overload every 10 minutes).
Specification
IP2x version
CFW11 variable speed drive Maximum applicable motor1)
ND HD kW HP HP kW HP HP
CFW110017T5ONFYZ 17 17 11 15 15 11 15 15
CFW110022T5ONFYZ 22 19 15 20 20 11 20 15
CFW110027T5ONFYZ 27 22 18.5 25 25 15 20 20
C Built-in
CFW110032T5ONFYZ 32 27 22 30 30 18.5 25 25
CFW110044T5ONFYZ 44 36 30 40 40 22 30 30
CFW110053T6OYZ 53 44 37 50 50 30 40 40
CFW110063T6OYZ 63 53 45 60 60 37 50 50
CFW110080T6OYZ 80 66 55 75 75 45 75 60
500-600 E
CFW110107T6OYZ Three-phase 107 90 75 100 100 55 100 75
V ac
CFW110125T6OYZ 125 107 90 125 125 75 100 100
CFW110289T6OYZ Not built-in; 289 240 200 300 300 160 250 250
use the
CFW110315T6OYZ DBW03 315 289 220 350 300 200 300 300
external
CFW110365T6OYZ accessory 365 315 260 380 350 220 350 300
G
CFW110435T6OYZ 435 357 300 450 450 260 380 350
Notes: 1) Motor powers are referential values valid for WEG W22 IE2 or HGF three-phase, 4-pole, 50 or 60 Hz induction motors. The proper size must be determined
according to the motor rated current, which must be lower than or equal to the inverter rated output current.
ND = Normal Duty (normal overload = 110% of the rated current for one minute or 150% of the rated current for 3 seconds; one overload every 10 minutes).
HD = Heavy Duty (heavy overload = 150% of the rated current for one minute or 200% of the rated current for 3 seconds; one overload every 10 minutes).
IP2x version
CFW11 variable speed drive Maximum applicable motor1)
ND HD kW HP HP kW HP HP
CFW110022T6ONFYZ 20 17 15 25 20 15 20 15
CFW110027T6ONFYZ 24 20 18.5 30 25 15 25 20
Built-in
CFW110032T6ONFYZ 30 24 22 30 30 18.5 30 25
CFW110044T6ONFYZ 35 30 30 40 40 22 30 30
CFW110053T6OYZ 46 39 37 60 60 30 50 40
CFW110063T6OYZ 54 46 45 60 60 37 60 50
CFW110080T6OYZ 73 61 55 75 75 55 75 75
500-690 E
CFW110107T6OYZ Three-phase 100 85 90 125 125 75 100 100
V ac
CFW110125T6OYZ 108 95 90 125 125 75 125 100
CFW110289T6OYZ Not built-in; 259 225 200 300 250 185 250 200
use the
CFW110315T6OYZ DBW03 259 225 220 300 300 200 300 270
external
CFW110365T6OYZ accessory 312 259 280 400 350 220 300 300
G
CFW110435T6OYZ 365 312 315 450 450 280 400 350
Notes: 1) Motor powers are referential values valid for WEG W22 IE2 or HGF three-phase, 4-pole, 50 or 60 Hz induction motors. The proper size must be determined
according to the motor rated current, which must be lower than or equal to the inverter rated output current.
ND = Normal Duty (normal overload = 110% of the rated current for one minute or 150% of the rated current for 3 seconds; one overload every 10 minutes).
HD = Heavy Duty (heavy overload = 150% of the rated current for one minute or 200% of the rated current for 3 seconds; one overload every 10 minutes).
Specification
IP55/NEMA type 12 version
This version of the inverter can be installed in environments with
high humidity, rain, exposed to sun and dust, without the need
for panels. The inverter cooling method ensures maximum
overload capacity and performance.
J Chemical Industry
J Petrochemical Industry
J Food Industry
IP55 version
CFW11 variable speed drive Maximum applicable motor1)
ND HD kW HP HP kW HP HP
CFW110006B2O55Z Single-phase or 200-240 6.0 5.0 1.5 2.0 1.5 1.1 1.5 1.0
CFW110007B2O55Z three-phase V ac 7.0 7.0 1.5 2.0 2.0 1.5 2.0 2.0
CFW110054T2O55Z 200-240 C 54 45 15 20 20 11 15 15
Three-phase
CFW110070T2O55Z V ac 70 56 22 25 25 15 20 20
CFW110086T2O55Z 86 70 22 30 30 22 25 25
D
CFW110105T2O55Z 105 86 30 40 40 22 30 30
Notes: 1) Motor powers are referential values valid for WEG W22 IE2 three-phase, 4-pole, 50 or 60 Hz induction motors. The proper size must be determined
according to the motor rated current, which must be lower than or equal to the inverter rated output current.
ND = Normal Duty (normal overload = 110% of the rated current for one minute or 150% of the rated current for 3 seconds; one overload every 10 minutes).
HD = Heavy Duty (heavy overload = 150% of the rated current for one minute or 200% of the rated current for 3 seconds; one overload every 10 minutes).
IP55 version
CFW11 variable speed drive Maximum applicable motor1)
ND HD kW HP kW HP HP kW HP kW HP HP
CFW110003T4O55Z 3.6 3.6 1.5 2.0 1.5 2.0 2.0 1.5 2.0 1.5 2.0 2.0
CFW110005T4O55Z 5.0 5.0 2.2 3.0 2.2 3.0 3.0 2.2 3.0 2.2 3.0 3.0
CFW110007T4O55Z 7.0 5.5 3.0 4.0 3.0 5.0 3.0 2.2 3.0 2,2 3.0 3.0
CFW110010T4O55Z 10 10 4.5 6.0 4.0 7.5 5.0 4.5 6.0 4.0 7.5 5.0
B
CFW110013T4O55Z 13.5 11 5.5 7.5 5.5 10 7.5 4.5 6.0 5.5 7.5 7.5
CFW110031T4O55Z 31 25 15 20 15 25 20 11 15 11 20 15
CFW110105T4O55DBZ 105 88 55 75 55 75 75 45 60 45 75 60
CFW110211T4O55DBZ 211 180 110 150 110 150 150 90 125 90 150 150
E
CFW110105T4O55Z 105 88 55 75 55 75 75 45 60 45 75 60
CFW110211T4O55Z 211 180 110 150 110 180 150 90 125 90 150 150
Notes: 1) Motor powers are referential values valid for WEG W22 IE2 three-phase, 4-pole, 50 or 60 Hz induction motors. The proper size must be determined
according to the motor rated current, which must be lower than or equal to the inverter rated output current.
ND = Normal Duty (normal overload = 110% of the rated current for one minute or 150% of the rated current for 3 seconds; one overload every 10 minutes).
HD = Heavy Duty (heavy overload = 150% of the rated current for one minute or 200% of the rated current for 3 seconds; one overload every 10 minutes).
Accessories
8 digital inputs
IOC-01 4 digital outputs 1
(use with SoftPLC)
8 digital inputs
IOC-02 1
8 open collector digital outputs (use with SoftPLC)
8 digital inputs
7 open collector external 24 V dc
IOC-03 1
digital outputs
(use with SoftPLC)
MODBUSTCP-05
PROFINETIO-05
ETHERNETIP-05
1, 2 and 3
Accessories
PLC11
The PLC11 accessory provides the CFW11 with PLC functionalities, such as network master, speed reference generator and
motion control functions.
It has two versions: PLC11-01 and PLC11-02 (see the differences below). In many applications, these accessories enable the
CFW11 to replace an external PLC, reducing costs.
Resources
J Motion control with trapezoidal “S” profiles (absolute and J Master/Slave function (electronic gearbox)
relative) J CAN interface for CANopen and DeviceNet protocols
J Search for the machine home position (homing) J Modbus-RTU Master and CANopen Master, which enables
J Ladder programming through the WLP software with the CFW11 to control up to 25 slave devices
timers, counters, coils and contacts J WLP/WSCAN software: network programming and
J RS485 serial interface with Modbus-RTU protocol configuration software in the same environment
J 100 configurable parameters available to the user through
Technical Data
J Digital inputs J RS485 interface J CANopen interface
J Digital outputs J Encoder interface inputs J Analog outputs
J Relay output
PLC11-01 PLC11-02
J 9 bi-directional inputs 24 V J 4 isolated bi-directional inputs 24 V
J 3 bi-directional open collector outputs: 24 V dc, 500 mA J 3 bi-directional open collector outputs: 24 V dc, 500 mA
J 3 outputs for NO contacts: 250 V ac, 3 A J 1 output for NO contacts: 250 V ac, 3 A
J 2 incremental encoder inputs 5...12 V dc, 500 mA (built-in J 2 incremental encoder inputs 5...12 V dc, 500 mA (built-in
J 1 CAN port (CANopen available) J 1 CAN port (CANopen and DeviceNet available)
Name Description
Notes: 1) The PCSD-01, PCSE-01 power cable shield kit is supplied together with inverters with RFI filter
installed at the factory. E.g.: CFW11 0007 T 2 O FA Z.
2) In frames D and E, the power cable shield kit is factory default, even for inverters without built-in
RFI filter.
3) Not available for frames F, G and H.
Cabinets
Stan- Frames
Classification
dards A B C D E F and G H
IP20 - - - X X X X
IEC
IP21 X X X KIP21D-01 - - -
KN1E-01/ KN1F-01/
NEMA Type 1 KN1A-01 KN1B-01 KN1C-01 X -
KN1E-02 KN1G-01
Note: (X) Default
(-) Not available
Note: In the KN1X-01 conduit kit (frames A, B and C), the power cable shield is also supplied.
Optional items
Note: 1) Those optional items must be installed at the factory and the orders must specify the desired option in the product coding (page 16).
Standard Version
Dimensions mm Weight kg
Frame
Height (H) Width (W) Depth (D) 200-240 V ac 380-480 V ac 500-690 V ac
A 270 145 227 6.3 6.3 -
B 316 190 227 9.1 10.4 9.1
C 405 220 293 17.9 20.5 19.6
D 550 300 305 31.4 32.6 34
E 675 335.2 358.2 65 65 64
F 1,234 430 360 - 140 168
G 1,264 535 426 - 215 258
H 1,414 686 420.8 - 220 213
IP55/NEMA12 version
D W
Dimensions mm
Frame Weight kg
Height (H) Width (W) Depth (D1) Depth (D2)
B 529 273 237 279 17.0
C 670 307 306 348 30.0
D 754 375 301.3 339 49.0
E 1,000 430 388,8 419 65.0
Mechanical Assembly
D D
Flange Mounting
a3 b3 c3 d3 e3
Frame a3
mm mm M mm mm
A 130 240 M5 135 225
B 175 285 M5 179 271
C 195 365 M6 205 345 b3 e3
Notes: For frames A to D, the area of the inverter outside the panel has IP54 protection rating.
For frames E (models 180T2, 211T2, 180T4 and 211T4), F and G, the area of the inverter outside the panel has IP54 protection rating (hardware
version H1).
For frame H, the area of the inverter outside the panel has IP20 protection rating.
2
1 = DC bus connection
2 = Connection for braking resistor
Pre-charge
Power
Supply
Motor
Three-phase Capacitor Bank Inverter
Rectifier with IGBT
transistor
PE RFI Filter
I/O Expansion
(Slot 1 White)
Encoder Interface
(Slot 2 Yellow)
HMI (remote)
HMI CC11
Control COMM1
Card (Slot 3 Green)
with
Digital Inputs 32-bit
(DI1 to DI6) Risc
CPU
COMM2
(Anybus) (Slot4)
Analog Inputs
(AI1 and AI2)
Analog Outputs
Flash
Memory
Module
Digital Outputs
DO1 (RL1) to
DO3 (RL3)
CONTROL
DC+ DC-
R1
Pre-charge
S1
Power
Supply
T1
Motor
Three-phase Capacitor Bank Inverter
Rectifier with IGBT
transistor
PE
RFI Filter
R2
Pre-charge
S2 PE
Power
Supply
T2
Three-phase
Rectifier
PE
POWER
/O Expansion
(Slot 1 White)
Encoder Interface
(Slot 2 Yellow)
HMI (remote)
HMI CC11
Control COMM1
Card (Slot 3 Green)
with
Digital Inputs 32-bit
(DI1 to DI6) RISC
COMM2
(Anybus) (Slot4)
Analog Inputs
(AI1 and AI2)
Analog Outputs
(AO1 and AO2)
Flash
Memory
Module
Digital Outputs
DO1 (RL1) to
DO3 (RL3)
CONTROL
Technical Data
Technical Data
Communication with SuperDrive G2 software EN 55011 - Limits and methods of measurement of radio disturbance characteristics of
USB industrial, scientific and medical (ISM) radio-frequency equipment
Communication with WLP software used for programming and
monitoring the SoftPLC function and PLC11 CISPR 11 - Industrial, scientific and medical (ISM) radio-frequency equipment
Electromagnetic disturbance characteristics Limits and methods of measurement
EN 61000-4-2 - Electromagnetic Compatibility Standards (EMC) Part 4: Testing and
Safety standards measurement techniques - Section 2: Electrostatic discharge immunity test
Safety standards EN 61000-4-3 - Electromagnetic Compatibility Standards (EMC) Part 4: Testing and
UL 840: Insulation coordination including clearances and creepage distances for electrical measurement techniques - Section 3:Radiated, radiofrequency, electromagnetic field
equipment immunity test
EN 61800-5-1: Safety requirements electrical, thermal and energy EN 61000-4-4 - Electromagnetic Compatibility Standards (EMC) Part 4: Testing and
measurement techniques - Section 4: Electrical fast transient / burst immunity test
EN 50178: Electronic equipment for use in power installations
EN 61000-4-5 - Electromagnetic Compatibility Standards (EMC) Part 4: Testing and
EN 60204-1: Safety of machinery. Electrical equipment of machines. measurement techniques - Section 5: Surge immunity test
Part 1: General requirements.
Note: In order to have a machine in accordance with this standard, the manufacturer of EN 61000-4-6 - Electromagnetic Compatibility Standards (EMC) Part 4: Testing and
the machine is responsible for installing an emergency stop device and a device for measurement techniques - Section 6: Immunity to conducted disturbances, induced by
disconnection from the power line. radio-frequency fields
EN 60146 (IEC 146): Semiconductor converters EN 61000-4-11 - Testing and measurement techniques - Voltage dips, short interruptions
and voltage variations immunity tests
EN 61800-2: Adjustable speed electrical power drive systems - Part 2: General requirements
- rating specifications for low voltage adjustable frequency a.c. power drive systems
Global Presence
With more than 30.000 employees worldwide, WEG is one of the largest electric motors, electronic equipments and systems
manufacturers. We are constantly expanding our portfolio of products and services with expertise and market knowledge. We
create integrated and customized solutions ranging from innovative products to complete after-sales service.
WEG’s know-how guarantees our Variable Speed Drive is the right choice for your application and business, assuring safety,
efficiency and reliability.
Know More
High performance and reliable
products to improve your
production process.
www.weg.net
+55 47 3276.4000