WEG CFW11 Brochure 50019076 en

Download as pdf or txt
Download as pdf or txt
You are on page 1of 36

CFW11 - VARIABLE

SPEED DRIVE
High productivity and performance
for your business

Motors | Automation | Energy | Transmission & Distribution | Coatings


CFW11
Variable Speed Drive

Table of Contents
Introduction 04

Benefits 05

Unique WEG Technology 06

Human-Machine Interface 08

Built-in SoftPLC on the Standard Product 10

WPS - WEG Programming Suite 11

Resources 12

Applications 14

Coding 16

Specifications 18

Accessories 24

Optional Items 28

Dimensions and Weights 29

Mechanical Assembly / Panel Mounting 30

Block Diagram 31

Technical Data 33
www.weg.net

Variable Speed Drive for


Industrial Systems

HIGH PRODUCTIVITY AND PERFORMANCE


FOR YOUR BUSINESS
The CFW11 is a high-tech variable speed drive designed to drive and control three-phase induction
motors and WEG WMagnet permanent-magnet motors. It has excellent static and dynamic
performance, and highly-precise torque, speed and position control. It can be used in a wide range of
applications due to its high overload capacity.
Developed for exclusive use in industrial or professional applications, the CFW11 inverter provides
energy savings and greater productivity and quality for the processes where it is used.

Power Ranges1)
J 1.5 to 2.2 kW - 2 to 3 HP / 200-240 V ac - Single-phase J 1.5 to 560 kW - 2 to 850 HP / 500-600 V ac - Three-phase
J 1.1 to 55 kW - 2 to 75 HP / 200-240 V ac - Three-phase J 2.2 to 630 kW - 3 to 850 HP / 600-690 V ac - Three-phase
J 1.5 to 630 kW - 2 to 970 HP / 380-480 V ac - Three-phase

Normal Duty (ND) Heavy Duty (HD)


J 110% for 60 seconds every 10 minutes J 150% for 60 seconds every 10 minutes

J 150% for 3 seconds every 10 minutes J 200% for 3 seconds every 10 minutes

Certifications

Note: for higher powers, contact WEG Automation or refer to the AFW11M catalog (Drive with Modular Variable Speed Drive).

4 CFW11 - Variable Speed Drives


www.weg.net

Benefits
Innovative and Easy to Use
The CFW11 has many useful and convenient functions for the customers, especially because of its simple installation
and operation. The CFW11 has been designed based on the plug-and-play technology, which allows a simple and
quick installation of the inverter and its accessories. The HMI has a navigation and programming system with soft
keys. You can access the parameters sequentially or through parameter groups.
The HMI also offers the oriented start-up function that guides the user along the programming.

Flexibility
The CFW11 is adaptable to the customer’s needs through a wide range of easy-to-install accessories. In
addition, the standard version comes with SoftPLC, allowing the customers to create their own applications
using the WLP (Ladder Programming) software application.

Connectivity
Communication protocols: Modbus-RTU, Modbus-TCP, Profibus-DP-V1, DeviceNet, CANopen, EtherNet/IP,
EtherCAT, PROFINET-IO and BACnet.

CFW11 - Variable Speed Drives 5


www.weg.net

Unique WEG Technology


Vectrue Technology ®

Several Control Modes


J Scalar V/F linear or adjustable: motor speed control with slip compensation

J VVW - Voltage Vector WEG - voltage vector control: motor speed control with automatic adjustment to the load and grid

variations
J Vector sensorless (without encoder) - induction motors: vector torque and speed control with excellent dynamic response,

even at low speeds


J Vector with encoder: the encoder module makes the interfaces between the CFW11 and the motor, providing closed-loop

position and speed control with excellent accuracy and dynamic response over the entire speed range (even when the motor
is stopped)
J Vector WMagnet sensorless (without encoder) and with encoder: vector control with excellent dynamic response for WEG

WMagnet motors over the entire speed range

Optimal Braking® Braking torque (%)


In applications involving high-inertia loads with reduced
deceleration times, a large amount of energy returns from Torque curve for dynamic braking
the motor to the variable speed drive. To withstand such Torque curve for optimal braking
energy, the variable speed drive needs to dissipate it Torque curve for DC braking
through resistors, which generally occupy a large space
100 (%)
and are expensive. As an alternative for the braking
resistors, the CFW11 has a special braking method in
vector control mode known as Optimal Braking®.
This innovation provides a high-performance braking
torque, eliminating the need for braking resistors. The
following chart shows the advantages of the optimal
TB1
braking in comparison with other braking methods, thus
ensuring an optimized, low-cost solution for braking 0
applications. 0 20% 100% 200%
Speed (%)
Typical braking torque x speed graph for a 10 HP / 7.5 kW motor
driven by a CFW11

6 CFW11 - Variable Speed Drives


www.weg.net

Optimal Flux®
J Technology for motors driven by variable speed drive in applications with constant torque characteristics

J Rated torque at low speeds, eliminating the need for forced ventilation or motor oversizing

J Reduced space and costs for the application

J Improved motor and inverter set performance (an exclusive WEG solution)

J The Optimal Flux function works when the high efficiency WEG motor + CFW11 configuration is used

WMagnet Drive System®

CFW11 Variable Speed Drive combined with WEG


WMagnet Permanent Magnet Motor
The WMagnet system (WMagnet motor + CFW11) has the
highest efficiency level of the market. It is the perfect
combination for applications requiring speed variation, low
noise level and reduced size. In the Sensorless mode, the
WMagnet system can perform torque control at zero speed
without the need for forced ventilation.

J  ontrol methods: closed-loop (vector with encoder) and sensorless


C
vector control

CFW11 - Variable Speed Drives 7


www.weg.net

Keypad
The keypad of the CFW11 has been developed to make the interaction with the user simple and fast, providing excellent visibility.

Interface Tools
J Graphic display with backlight

J Soft Keys for easy operation

J Real time clock (RTC)

J Copy Function

J Plug-in (allows hot swapping)

J Language selection

J Remote keypad Right soft key: function


defined by the text on the display

Left soft key: function defined by the Keys to scroll the menus and
parameters and to change the
text on the display
content of the parameters

Selection of direction of rotation


Start key

Local/Remote Stop key

JOG key

Remote Keypad
The standard keypad is detachable and can be
installed on panel doors or machine consoles
with IP56 protection rating.

Backup Parameters Function Group


The backup parameter group allows transferring the The HMI displays parameter groups in individual folders,
CFW11 parameters to the keypad or to the flash and each of them shows specific settings. For example:
memory module (available in the standard product) and I/O setting, auto-tuning procedure, basic parameters,
vice versa. During the CFW11 operation, the modified etc.
parameters are automatically saved to the flash
memory module.

Selectable Languages Changed Parameters


The user can choose the HMI language: It displays only the parameters that have been
Portuguese, English, Spanish, German or French. programmed differently from the factory default.

8 CFW11 - Variable Speed Drives


www.weg.net

The HMI can be configured to display up to four variables simultaneously, in three different modes.

Status Indication
J Run J Auto-tuning
J Ready J Last alarm
J Configuration J Inverter disabled by fault and fault number

Local/Remote Indication

Direction of Rotation Indication

Basic Application
The Basic Application parameter group contains the basic parameters,
whose settings are required in most applications.

Fault History
It displays the parameters with the last ten faults, informing the
day, month, year and hour of the events.

Reading Parameters
It displays only the inverter
monitoring parameters.

CFW11 - Variable Speed Drives 9


www.weg.net

SoftPLC - Built-In on the Standard Product


Adds the functionality of a PLC to the CFW11, allowing the creation of special applications. The WLP software and the SoftPLC
functionality are a smart and simple way to make your CFW11, motor and application work together.

Easy programming: Ladder

Contacts and coils

Speed reference

Comparators and math functions

Counters and timers

Available on the User block


website protected by
www.weg.net password

Trend Function
J Parameter/variable online graphic monitoring

J Configurable in up to six channels

10 CFW11 - Variable Speed Drives


www.weg.net

WPS - WEG Programming Suite


Application to program, control and monitor WEG variable speed drive.

Trace Function
J It registers the CFW11 variables with activation by events

(e.g., alarm, fault, overvoltage), storing the data on the


inverter memory, which then can be viewed in the form of
graphs.

USB connection

Friendly environment

Available on the website


www.weg.net

CFW11 - Variable Speed Drives 11


www.weg.net

Resources
Safety Stop Function - Safe Torque Off (STO)
Enabling the safety stop function assures to stop the driven motor and/or prevents it from being accidentally started which
could be an important component of a machine and process safety system.
The STO function can be used in category 3 / PL d applications according to the EN ISO13849-1 standard and SIL 2
according to the IEC62061 and IEC61508 standards.
This is an optional feature and available in versions with the STO function.

Built-in DC Link Inductor


It allows the inverter to be installed in any network (without minimum impedance restrictions).
Typical power factor (PF) for rated condition:
J 0.94 for models with three-phase power supply

J 0.70 for models with single-phase power supply

J 0.70 for models with single-phase/three-phase power supply

Displacement factor > 0.98

DC Link Inductor Reduces Harmonic Distortion


The CFW11 inverters (up to frame G) are equipped with a DC link inductor to mitigate harmonics, providing compliance with the
requirements of IEC 61000 parts 3-2 and 3-12, related to the injection of harmonics into the line. For frame H, it is mandatory to
add line reactance.

L1

R U
V M
S
W 3~
T

L2

Note: in frames A to G, no additional line reactor is required.

Dynamic Braking
Braking IGBT (chopper) can be offered built-in or with external module (DBW03/DBW04).

Conformal Coating
Application of a special varnish on the CFW11 electronic
boards to extend the service life, protecting against dust,
moisture and corrosive chemicals.
Class 3C2 protection is standard for the entire CFW11 line
and in compliance with IEC 60721-3-3. Also available in the
Extra-Coating version, class 3C3, as an optional item.

12 CFW11 - Variable Speed Drives


www.weg.net

Monitoring of Motor Temperatures


Monitoring of the motor temperature readings (PTC, Pt-100, KTY84), providing thermal protection for the motor (accessory
required).

Single DC Busbar
Usually used in multimotor systems, this configuration is a great solution for energy savings and reduced installation costs,
since the individual rectifier bridges of the inverters are replaced by a single rectifier bridge. Each variable speed drive is then
fed with direct current through its DC power terminals.

This solution allows the power on the DC link to be shared by the inverters connected to it, thus optimizing the energy
consumption.
Standard frames A to E and H of the CFW11 in the standard version and sizes F and G in the special hardware version (DC)
can be connected to a DC bus system (refer to the User’s Manual for further information).

Power supply Single DC Link

General input
rectifier unit

CFW11

1 2 3 4 n

Note: a pre-charge circuit must be added to each of the variable speed drive.

Intelligent Thermal Management


J Monitoring of the heatsink and internal air
temperatures on the electronic boards,
providing full protection for the IGBTs and
CFW11 as a whole
J The heatsink fan is turned on and off

automatically, depending on the


temperature of the power modules
J The speed and running time of the fans

are monitored and indicated in


parameters
J The fan can be easily removed for

cleaning or replacement

Operating Temperature
Ambient temperature up to 60 °C for
frames A to D (except IP55 models) and up
to 55 °C for frames E, F, G and H, with
current derating (refer to the User’s
Manual).

CFW11 - Variable Speed Drives 13


www.weg.net

Applications
Thanks to its wide range of functions, high overload capacity, easy setup, installation and operation, in addition to offering the
panel-mounted versions (AFW11, APW11 and modular AFW11M/W), the CFW11 is the ideal variable speed drive for different
applications, in different industry sectors.

Steel and Metallurgy Refrigeration Sugar and Alcohol

Pulp and Paper Wood Cement and Mining Chemicals and Petrochemical

The CFW11 has also been developed for applications where safety is an essential requirement, because, in addition to the
built-in protections and alarms, it has a safety stop function according to EN ISO 13849-1 and IEC 62061/IEC 61508 and
TÜV Rheiland certification.

Pumps and Fans Compressors


Reduction of the electric energy consumption, precise control of Reduction of the electric energy consumption, higher
process variables (pressure, flow, temperature) with PID regulator, efficiency and demand control, lower starting current,
maintenance and safety alarm indication. prevention of mechanical wear.

Multipump Control Load Lifting


It maintains constant pipe line pressure, regardless of oscillations The vector mode ensures precise stop and speed control
in the flow demand. even at low speeds.

14 CFW11 - Variable Speed Drives


www.weg.net

Machines and Processes in General


Copy and download of parameters via keypad or built-in flash memory, free software applications, excellent cost-benefit and
simple operation.

Mills and Centrifuges Equipment in Steel and Metallurgy


The wide power range of the CFW11 line, combined with the Ideal for applications requiring extremely reliable and robust
possibility of connection to a single DC link, allows the DC drives with high overload capacity (HD-sized models).
link energy to be shared by the inverters connected to it, thus
optimizing the energy consumption in the system.

Conveyor Belts HVAC-R


Due to its programming flexibility and hardware configuration, The SoftPLC function incorporated to the standard product
the CFW11 makes adjusting applications where synchronism allows the use of two PID controllers simultaneously. Such
is essential quite simple. feature is ideal for HVAC-R applications.

CFW11 - Variable Speed Drives 15


www.weg.net

Coding1)

1 CFW11 2 0016 3 T 4 4 5 S 6 --- 7 ---

1 - WEG CFW11 variable speed drive


2 - Rated output current for normal duty (ND)
Single-phase or
Power Supply Single-phase (S) Three-phase (T)
Three-phase (B)
Voltage 200-240 V ac 200-240 V ac 200-240 V ac 380-480 V ac 500-600 V ac 660-690 V ac
0007 = 7 A 0003 = 3 A 0180 = 180 A
0002 = 2,9 A 0107 = 107 A 0002 = 2,9 A 0107 = 100 A
0010 = 10 A 0005 = 5 A 0211 = 211 A
0004 = 4,2 A 0125 = 125 A 0004 = 4,2 A 0125 = 108 A
0013 = 13 A 0007 = 7 A 0242 = 242 A
0007 = 7 A 0150 = 150 A 0007 = 7 A 0150 = 130 A
0016 = 16 A 0010 = 10 A 0312 = 312 A
0010 = 10 A 0170 = 170 A 0010 = 8,5 A 0170 = 147 A
0024 = 24 A 0013 = 13 A 0370 = 370 A
0012 = 12 A 0216 = 216 A 0012 = 11 A 0216 = 195 A
0028 = 28 A 0017 = 17 A 0477 = 477 A
0006 = 6 A 0017 = 17 A 0289 = 289 A 0289 = 259 A
0033 = 33 A 0024 = 24 A 0017 = 15 A
0006 = 6 A 0515 = 515 A 0315 = 315 A 0315 = 259 A
Current 0007 = 7 A 0045 = 45 A 0031 = 31 A 0022 = 22 A 0022 = 20 A
0007 = 7 A 0601 = 601 A 0365 = 365 A 0365 = 312 A
0010 = 10 A 0054 = 54 A 0038 = 38 A 0027 = 27 A 0027 = 24 A
0720 = 720 A 0435 = 435 A 0435 = 365 A
0070 = 70 A 0045 = 45 A 0032 = 32 A 0032 = 30 A
0760 = 760 A 0472 = 472 A 0472 = 427 A
0086 = 86 A 0058 = 58 A 0044 = 44 A 0044 = 35 A
0795 = 795 A 0584 = 584 A 0584 = 478 A
0105 = 105 A 0070 = 70 A 0053 = 53 A 0053 = 46 A
0877 = 877 A 0625 = 625 A 0625 = 518 A
0142 =142 A 0088 = 88 A 0063 = 63 A 0063 = 54 A
1062 = 1062 A 0758 = 758 A 0758 = 628 A
0180 = 180 A 0105 = 105 A 0080 = 80 A 0080 = 73 A
1141 = 1141 A 0804 = 804 A 0804 = 703 A
0211 = 211 A 0142 = 142 A

3 - Number of phases 6 - Degree of protection

S Single-phase Blank Standard (according to the table below)

B Single-phase or three-phase 21 IP21

T Three-phase N1 NEMA1

55 IP55
4 - Voltage
Frame Degree of protection Special DC hardware
200-240 V: for frames A, B, C and D
2
220-230 V: for frame E and F A IP21 No
4 380-480 V B IP21 No
5 500-600 V C IP21 No
6 660-690 V D NEMA1 / IP20 No

E IP20 No
5 - Optional accessories
IP20 No
S Factory default model F
IP00 Yes
O Product with optional items
IP20 No
G
IP00 Yes

H IP20 No

Note: 1) Other configurations available upon request.

16 CFW11 - Variable Speed Drives


www.weg.net

8 --- 9 --- 10 --- 11 --- 12 --- 13 --- 14 ---

7 - HMI 10 - Safety stop: Safe Torque Off (STO)

Blank With operating interface (HMI) included Blank Not built-in

O No operating interface (HMI) - with blank cover Y Built-in STO module included. 500-690 V any size: built-in

8 - Braking 11 - External power supply of the electronics at 24 V dc

Frames A, B, C and D: Built-in brake IGBT. Frames E, F and G: Blank Factory default model
200-480 V
Brake IGBT not incorporated.
W With external power supply of the electronics at 24 V dc
Frame B: Built-in brake IGBT.
Frames F and G: Brake IGBT not incorporated
Blank 500-600 V (use DBW03 - see accessories). 12 - Special hardware
Frame H: Brake IGBT not incorporated
(use DBW04 - see accessories). Blank Factory default model
Frames D and E: Built-in brake IGBT. H Special hardware included
500-690 V
Frames F and G: Brake IGBT not incorporated.
200-480 V Frame E: Built-in brake IGBT. DC Power supply via DC link (without rectifier bridge)
DB Frames D and E: Brake IGBT already built-in DS With built-in switch disconnector (IP55 models only)
500-690 V
(no need to include “DB” in the smart code).
500-690 V Brake IGBT not included in frames B, C, D and E. 13 - Special software
NB
200-480 V Frames A, B, C, D and E: not available without brake IGBT.
Blank Factory default model
9 - RFI filter Sx Special software included

Frames A, B, C and D: without RFI filter.


200-480 V
Frames E, F, G and H with built-in RFI filter. 14 - End-of-coding indicator digit
Blank
500-600 V Frame B: built-in RFI filter. Z End-of-code indicator
500-690 V Frames D, E, F, G and H: built-in RFI filter.
200-480 V Frames A, B, C and D: built-in RFI filter.
FA Any frame: already built-in
500-690 V
(no need for FA in the smart code).
Frames A, B, C and D: standard without RFI filter
200-480 V
(no need for NF in the smart code).
NF
500-600 V Frame B: without RFI filter.
500-690 V Frame D: without RFI filter.

CFW11 - Variable Speed Drives 17


www.weg.net

Specification
IP2x version
Maximum applicable motor1)
CFW11 variable speed drive
Normal duty (ND) Heavy duty (HD)

IEC UL IEC UL
Rated output current
Frame Braking 50 Hz 60 Hz 60 Hz 50 Hz 60 Hz 60 Hz
(A)
Reference Power supply (V)
size IGBT 230 V ac 220 V ac 230 V ac 230 V ac 220 V ac 230 V ac

ND HD kW HP HP kW HP HP

CFW110006S2OFAZ 6.0 5.0 1.5 2.0 1.5 1.1 1.5 1.0


200-240
CFW110007S2OFAZ Single-phase A 7.0 7.0 1.5 2.0 2.0 1.5 2.0 2.0
V ac
CFW110010S2SZ 10 10 2.2 3.0 3.0 2.2 3.0 3.0

CFW110006B2SZ Single-phase or 200-240 6.0 5.0 1.5 2.0 1.5 1.1 1.5 1.0
A
CFW110007B2SZ three-phase V ac 7.0 7.0 1.5 2.0 2.0 1.5 2.0 2.0

CFW110007T2SZ 7.0 5.5 1.5 2.0 2.0 1.1 1.5 1.0

CFW110010T2SZ 10 8.0 2.2 3.0 3.0 1.5 2.0 2.0


A
CFW110013T2SZ 13 11 3.0 4.0 3.0 3 3.0 3.0

CFW110016T2SZ 16 13 4.0 5.0 5.0 3 4.0 3.0

CFW110024T2SZ 24 20 5.5 7.5 7.5 5.5 6.0 5.0


Built-in
CFW110028T2SZ B 28 24 7.5 10 10 5.5 7.5 7.5

CFW110033T2SZ 33.5 28 9.2 12.5 10 7.5 10 10

CFW110045T2SZ 45 36 11 15 15 9.2 12.5 10

CFW110054T2SZ 200-240 C 54 45 15 20 20 11 15 15
Three-phase
V ac
CFW110070T2SZ 70 56 22 25 25 15 20 20

CFW110086T2SZ 86 70 22 30 30 22 25 25
D
CFW110105T2SZ 105 86 30 40 40 22 30 30

CFW110142T2ODBZ 142 115 45 50 50 30 40 40

CFW110180T2ODBZ 180 142 55 75 60 45 50 50

CFW110211T2ODBZ 211 180 55 75 75 55 75 60


E
CFW110142T2SZ 142 115 45 50 50 30 40 40

CFW110180T2SZ Not built-in 180 142 55 75 60 45 50 50

CFW110211T2SZ 211 180 55 75 75 55 75 60

Notes: 1) Motor powers are referential values valid for WEG W22 IE2 three-phase, 4-pole, 50 or 60 Hz induction motors. The proper size must be determined
according to the motor rated current, which must be lower than or equal to the inverter rated output current.
ND = Normal Duty (normal overload = 110% of the rated current for one minute or 150% of the rated current for 3 seconds; one overload every 10 minutes).
HD = Heavy Duty (heavy overload = 150% of the rated current for one minute or 200% of the rated current for 3 seconds; one overload every 10 minutes).

18 CFW11 - Variable Speed Drives


www.weg.net

IP2x version
Maximum applicable motor1)
CFW11 variable speed drive
Normal duty (ND) Heavy duty (HD)

IEC IEC UL IEC IEC UL


Rated output current
60 Hz 60 Hz 50 Hz 60 Hz 60 Hz 60 Hz 60 Hz 50 Hz 60 Hz 60 Hz
Power supply Frame Braking (A)
Reference
(V) size IGBT 380 V ac 380 V ac 415 V ac 460 V ac 460 V ac 380 V ac 380 V ac 415 V ac 460 V ac 460 V ac

ND HD kW HP kW HP HP kW HP kW HP HP

CFW110003T4SZ 3.6 3.6 1.5 2.0 1.5 2.0 2.0 1.5 2.0 1.5 2.0 2.0

CFW110005T4SZ 5.0 5.0 2.2 3.0 2.2 3.0 3.0 2.2 3.0 2.2 3.0 3.0

CFW110007T4SZ A 7.0 5.5 3.0 4.0 3.0 5.0 3.0 2.2 3.0 2.2 3.0 3.0

CFW110010T4SZ 10 10 4.5 6.0 4.0 7.5 5.0 4.5 6.0 4.0 7.5 5.0

CFW110013T4SZ 13.5 11 5.5 7.5 5.5 10 7.5 4.5 6.0 5.5 7.5 7.5

CFW110017T4SZ 17 13.5 7.5 10 9.2 10 10 5.5 7.5 5.5 10 7.5

CFW110024T4SZ B 24 19 11 15 11 20 15 9.2 12.5 9.2 15 10

CFW110031T4SZ 31 25 15 20 15 25 20 11 15 11 20 15

CFW110038T4SZ Built-in 38 33 18.5 25 18.5 30 25 15 20 15 25 20

CFW110045T4SZ C 45 38 22 30 22 30 30 18.5 25 18.5 30 25

CFW110058T4SZ 58.5 47 30 40 30 50 40 22 30 22 30 30

CFW110070T4SZ 70.5 61 37 50 37 60 50 30 40 30 50 40
D
CFW110088T4SZ 88 73 45 60 45 75 60 37 50 37 60 50

CFW110105T4ODBZ 105 88 55 75 55 75 75 45 60 45 75 60

CFW110142T4ODBZ 142 115 75 100 75 100 100 55 75 55 100 75

CFW110180T4ODBZ 180 142 90 125 90 150 150 75 100 75 100 100


380-480
CFW110211T4ODBZ Three-phase 211 180 110 150 110 150 150 90 125 90 150 150
V ac
E
CFW110105T4SZ 105 88 55 75 55 75 75 45 60 45 75 60

CFW110142T4SZ 142 115 75 100 75 100 100 55 75 55 100 75


Not built-in
CFW110180T4SZ 180 142 90 125 90 150 150 75 100 75 100 100

CFW110211T4SZ 211 180 110 150 110 180 150 90 125 90 150 150

CFW110242T4SZ 242 211 110 150 132 200 200 110 150 110 150 150

CFW110312T4SZ 312 242 150 200 160 270 250 110 150 132 200 200
F
CFW110370T4SZ 370 312 200 270 200 300 300 150 200 160 250 250
Not
CFW110477T4SZ built-in; use 477 370 260 350 260 350 400 200 270 200 300 300
external
CFW110515T4SZ accessory 515 477 260 350 300 450 400 220 300 280 400 400
DBW03
CFW110601T4SZ 601 515 300 400 355 500 500 260 350 300 450 400
G
CFW110720T4SZ 720 560 370 500 400 610 600 300 400 315 500 400

CFW110760T4SZ 760 600 400 550 450 680 600 300 400 330 550 500

CFW110795T4SZ 795 637 400 550 450 680 600 330 450 355 550 500
Not
CFW110877T4SZ built-in; use 877 715 480 650 500 750 700 370 500 400 610 500
H external
CFW111062T4SZ accessory 1,062 855 560 750 560 850 900 440 600 500 750 700
DBW04
CFW111141T4SZ 1,141 943 590 800 630 970 1,000 515 700 560 750 800

Notes: 1) Motor powers are referential values valid for WEG W22 IE2 or HGF three-phase, 4-pole, 50 or 60 Hz induction motors. The proper size must be determined
according to the motor rated current, which must be lower than or equal to the inverter rated output current.
ND = Normal Duty (normal overload = 110% of the rated current for one minute or 150% of the rated current for 3 seconds; one overload every 10 minutes).
HD = Heavy Duty (heavy overload = 150% of the rated current for one minute or 200% of the rated current for 3 seconds; one overload every 10 minutes).

CFW11 - Variable Speed Drives 19


www.weg.net

Specification
IP2x version
CFW11 variable speed drive Maximum applicable motor1)

Normal duty (ND) Heavy duty (HD)

Rated output current IEC UL IEC UL


Frame (A)
Reference Power supply (V) Braking 50 Hz 60 Hz 60 Hz 50 Hz 60 Hz 60 Hz
size
IGBT
525 V ac 575 V ac 575 V ac 525 V ac 575 V ac 575 V ac

ND HD kW HP HP kW HP HP

CFW110002T5ONFYZ 2.9 2.7 1.5 2.0 2.0 1.5 2.0 2.0

CFW110004T5ONFYZ 4.2 3.8 2.2 3.0 3.0 2.2 3.0 2.0

CFW110007T5ONFYZ 7.0 6.5 4.0 5.0 5.0 4.0 5.0 5.0


B
CFW110010T5ONFYZ 10 9.0 5.5 7.5 7.5 5.5 7.5 7.5

CFW110012T5ONFYZ 12 10 7.5 10 10 5.5 7.5 7.5

CFW110017T5ONFYZ 17 17 11 15 15 11 15 15

CFW110022T5ONFYZ 22 19 15 20 20 11 20 15

CFW110027T5ONFYZ 27 22 18.5 25 25 15 20 20
C Built-in
CFW110032T5ONFYZ 32 27 22 30 30 18.5 25 25

CFW110044T5ONFYZ 44 36 30 40 40 22 30 30

CFW110053T6OYZ 53 44 37 50 50 30 40 40

CFW110063T6OYZ 63 53 45 60 60 37 50 50

CFW110080T6OYZ 80 66 55 75 75 45 75 60
500-600 E
CFW110107T6OYZ Three-phase 107 90 75 100 100 55 100 75
V ac
CFW110125T6OYZ 125 107 90 125 125 75 100 100

CFW110150T6OYZ 150 122 110 150 150 90 125 100

CFW110170T6OYZ 170 150 110 175 150 110 150 150

CFW110216T6OYZ F 216 180 160 200 250 132 175 150

CFW110289T6OYZ Not built-in; 289 240 200 300 300 160 250 250
use the
CFW110315T6OYZ DBW03 315 289 220 350 300 200 300 300
external
CFW110365T6OYZ accessory 365 315 260 380 350 220 350 300
G
CFW110435T6OYZ 435 357 300 450 450 260 380 350

CFW110472T6OYZ 472 418 330 500 500 300 430 450

CFW110584T6OYZ 584 504 400 600 600 370 550 500


Not built-in;
CFW110625T6OYZ use the 625 540 450 650 700 370 550 600
H DBW04
CFW110758T6OYZ external 758 614 560 750 800 450 680 600
accessory
CFW110804T6OYZ 804 682 560 850 900 500 750 700

Notes: 1) Motor powers are referential values valid for WEG W22 IE2 or HGF three-phase, 4-pole, 50 or 60 Hz induction motors. The proper size must be determined
according to the motor rated current, which must be lower than or equal to the inverter rated output current.
ND = Normal Duty (normal overload = 110% of the rated current for one minute or 150% of the rated current for 3 seconds; one overload every 10 minutes).
HD = Heavy Duty (heavy overload = 150% of the rated current for one minute or 200% of the rated current for 3 seconds; one overload every 10 minutes).

20 CFW11 - Variable Speed Drives


www.weg.net

IP2x version
CFW11 variable speed drive Maximum applicable motor1)

Normal duty (ND) Heavy duty (HD)

Rated output current IEC UL IEC UL


Frame Braking (A)
Reference Power supply (V) 50 Hz 60 Hz 60 Hz 50 Hz 60 Hz 60 Hz
size IGBT
660 V ac 690 V ac 660 V ac 660 V ac 690 V ac 660 V ac

ND HD kW HP HP kW HP HP

CFW110002T6ONFYZ 2.9 2.7 2.2 3.0 3.0 1.5 3.0 2.0

CFW110004T6ONFYZ 4.2 3.8 3.0 4.0 4.0 2.2 4.0 4.0

CFW110007T6ONFYZ 7.0 6.5 5.5 7.5 7.5 4.0 7.5 6.0

CFW110010T6ONFYZ 8.5 7.0 5.5 10 10 5.5 7.5 7.5

CFW110012T6ONFYZ 11 9.0 9.2 12.5 12.5 7.5 10 10


D
CFW110017T6ONFYZ 15 13 11 15 15 11 15 15

CFW110022T6ONFYZ 20 17 15 25 20 15 20 15

CFW110027T6ONFYZ 24 20 18.5 30 25 15 25 20
Built-in
CFW110032T6ONFYZ 30 24 22 30 30 18.5 30 25

CFW110044T6ONFYZ 35 30 30 40 40 22 30 30

CFW110053T6OYZ 46 39 37 60 60 30 50 40

CFW110063T6OYZ 54 46 45 60 60 37 60 50

CFW110080T6OYZ 73 61 55 75 75 55 75 75
500-690 E
CFW110107T6OYZ Three-phase 100 85 90 125 125 75 100 100
V ac
CFW110125T6OYZ 108 95 90 125 125 75 125 100

CFW110150T6OYZ 130 108 110 150 125 90 125 125

CFW110170T6OYZ 147 127 132 180 175 110 150 150

CFW110216T6OYZ F 195 165 185 250 200 132 200 200

CFW110289T6OYZ Not built-in; 259 225 200 300 250 185 250 200
use the
CFW110315T6OYZ DBW03 259 225 220 300 300 200 300 270
external
CFW110365T6OYZ accessory 312 259 280 400 350 220 300 300
G
CFW110435T6OYZ 365 312 315 450 450 280 400 350

CFW110472T6OYZ 427 365 400 500 550 355 400 400

CFW110584T6OYZ 478 410 450 610 600 370 550 500


Not built-in;
CFW110625T6OYZ use the 518 447 500 680 650 400 550 550
H DBW04
CFW110758T6OYZ external 628 518 560 750 800 500 680 650
accessory
CFW110804T6OYZ 703 594 630 850 900 560 750 750

Notes: 1) Motor powers are referential values valid for WEG W22 IE2 or HGF three-phase, 4-pole, 50 or 60 Hz induction motors. The proper size must be determined
according to the motor rated current, which must be lower than or equal to the inverter rated output current.
ND = Normal Duty (normal overload = 110% of the rated current for one minute or 150% of the rated current for 3 seconds; one overload every 10 minutes).
HD = Heavy Duty (heavy overload = 150% of the rated current for one minute or 200% of the rated current for 3 seconds; one overload every 10 minutes).

CFW11 - Variable Speed Drives 21


www.weg.net

Specification
IP55/NEMA type 12 version
This version of the inverter can be installed in environments with
high humidity, rain, exposed to sun and dust, without the need
for panels. The inverter cooling method ensures maximum
overload capacity and performance.

J Chemical Industry
J Petrochemical Industry
J Food Industry

They use the same communication and I/O accessories as


IP20/21 inverters.
Also available in the version with built-in switch disconnector for
a fast and safe isolation of the power line.

IP55 version
CFW11 variable speed drive Maximum applicable motor1)

Normal duty (ND) Heavy duty (HD)

Rated output current IEC UL IEC UL


Frame (A)
Reference Power supply (V) Braking 50 Hz 60 Hz 60 Hz 50 Hz 60 Hz 60 Hz
size
IGBT
230 V ac 220 V ac 230 V ac 230 V ac 220 V ac 230 V ac

ND HD kW HP HP kW HP HP

CFW110006S2O55FAZ 6.0 5.0 1.5 2.0 1.5 1.1 1.5 1.0


200-240
CFW110007S2O55FAZ Single-phase 7.0 7.0 1.5 2.0 2.0 1.5 2.0 2.0
V ac
CFW110010S2O55Z 10 10 2.2 3.0 3.0 2.2 3.0 3.0

CFW110006B2O55Z Single-phase or 200-240 6.0 5.0 1.5 2.0 1.5 1.1 1.5 1.0

CFW110007B2O55Z three-phase V ac 7.0 7.0 1.5 2.0 2.0 1.5 2.0 2.0

CFW110007T2O55Z 7.0 5.5 1.5 2.0 2.0 1.1 1.5 1.0


B
CFW110010T2O55Z 10 8.0 2.2 3.0 3.0 1.5 2.0 2.0

CFW110013T2O55Z 13 11 3.0 4.0 3.0 3 3.0 3.0

CFW110016T2O55Z 16 13 4.0 5.0 5.0 3 4.0 3.0

CFW110024T2O55Z 24 20 5.5 7.5 7.5 5.5 6.0 5.0


Built-in
CFW110028T2O55Z 28 24 7.5 10 10 5.5 7.5 7.5

CFW110033T2O55Z 33.5 28 9.2 12.5 10 7.5 10 10

CFW110045T2O55Z 45 36 11 15 15 9.2 12.5 10

CFW110054T2O55Z 200-240 C 54 45 15 20 20 11 15 15
Three-phase
CFW110070T2O55Z V ac 70 56 22 25 25 15 20 20

CFW110086T2O55Z 86 70 22 30 30 22 25 25
D
CFW110105T2O55Z 105 86 30 40 40 22 30 30

CFW110142T2O55DBZ 142 115 45 50 50 30 40 40

CFW110180T2O55DBZ E 180 142 55 75 60 45 50 50

CFW110211T2O55DBZ 211 180 55 75 75 55 75 60

CFW110142T2O55Z 142 115 45 50 50 30 40 40

CFW110180T2O55Z E Not built-in 180 142 55 75 60 45 50 50

CFW110211T2O55Z 211 180 55 75 75 55 75 60

Notes: 1) Motor powers are referential values valid for WEG W22 IE2 three-phase, 4-pole, 50 or 60 Hz induction motors. The proper size must be determined
according to the motor rated current, which must be lower than or equal to the inverter rated output current.
ND = Normal Duty (normal overload = 110% of the rated current for one minute or 150% of the rated current for 3 seconds; one overload every 10 minutes).
HD = Heavy Duty (heavy overload = 150% of the rated current for one minute or 200% of the rated current for 3 seconds; one overload every 10 minutes).

22 CFW11 - Variable Speed Drives


www.weg.net

IP55 version
CFW11 variable speed drive Maximum applicable motor1)

Normal duty (ND) Heavy duty (HD)

Rated output IEC IEC UL IEC IEC UL


Frame Braking current (A)
Reference Power supply (V) 60 Hz 60 Hz 50 Hz 60 Hz 60 Hz 60 Hz 60 Hz 50 Hz 60 Hz 60 Hz
size IGBT
380 V ac 380 V ac 415 V ac 460 V ac 460 V ac 380 V ac 380 V ac 415 V ac 460 V ac 460 V ac

ND HD kW HP kW HP HP kW HP kW HP HP

CFW110003T4O55Z 3.6 3.6 1.5 2.0 1.5 2.0 2.0 1.5 2.0 1.5 2.0 2.0

CFW110005T4O55Z 5.0 5.0 2.2 3.0 2.2 3.0 3.0 2.2 3.0 2.2 3.0 3.0

CFW110007T4O55Z 7.0 5.5 3.0 4.0 3.0 5.0 3.0 2.2 3.0 2,2 3.0 3.0

CFW110010T4O55Z 10 10 4.5 6.0 4.0 7.5 5.0 4.5 6.0 4.0 7.5 5.0
B
CFW110013T4O55Z 13.5 11 5.5 7.5 5.5 10 7.5 4.5 6.0 5.5 7.5 7.5

CFW110017T4O55Z 17 13.5 7.5 10 9.2 10 10 5.5 7.5 5.5 10 7.5

CFW110024T4O55Z 24 19 11 15 11 20 15 9.2 12.5 9.2 15 10

CFW110031T4O55Z 31 25 15 20 15 25 20 11 15 11 20 15

CFW110038T4O55Z Built-in 38 33 18.5 25 18.5 30 25 15 20 15 25 20

CFW110045T4O55Z C 45 38 22 30 22 30 30 18.5 25 18,5 30 25


380-480
CFW110058T4O55Z Three-phase 58.5 47 30 40 30 50 40 22 30 22 30 30
V ac
CFW110070T4O55Z 70.5 61 37 50 37 60 50 30 40 30 50 40
D
CFW110088T4O55Z 88 73 45 60 45 75 60 37 50 37 60 50

CFW110105T4O55DBZ 105 88 55 75 55 75 75 45 60 45 75 60

CFW110142T4O55DBZ 142 115 75 100 75 100 100 55 75 55 100 75

CFW110180T4O55DBZ 180 142 90 125 90 150 150 75 100 75 100 100

CFW110211T4O55DBZ 211 180 110 150 110 150 150 90 125 90 150 150
E
CFW110105T4O55Z 105 88 55 75 55 75 75 45 60 45 75 60

CFW110142T4O55Z 142 115 75 100 75 100 100 55 75 55 100 75


Not built-in
CFW110180T4O55Z 180 142 90 125 90 150 150 75 100 75 100 100

CFW110211T4O55Z 211 180 110 150 110 180 150 90 125 90 150 150

Notes: 1) Motor powers are referential values valid for WEG W22 IE2 three-phase, 4-pole, 50 or 60 Hz induction motors. The proper size must be determined
according to the motor rated current, which must be lower than or equal to the inverter rated output current.
ND = Normal Duty (normal overload = 110% of the rated current for one minute or 150% of the rated current for 3 seconds; one overload every 10 minutes).
HD = Heavy Duty (heavy overload = 150% of the rated current for one minute or 200% of the rated current for 3 seconds; one overload every 10 minutes).

CFW11 - Variable Speed Drives 23


www.weg.net

Accessories

Name Description Slot Image

1 14-bit voltage or current analog input


2 digital inputs
IOA-01 1
2 14-bits voltage or current analog outputs
2 open collector digital outputs

2 isolated 12-bit analog inputs


2 digital inputs
IOB-01 1
2 14-bits voltage or current analog outputs
2 open collector digital outputs
I/O expansion

8 digital inputs
IOC-01 4 digital outputs 1
(use with SoftPLC)

8 digital inputs
IOC-02 1
8 open collector digital outputs (use with SoftPLC)

8 digital inputs
7 open collector external 24 V dc
IOC-03 1
digital outputs
(use with SoftPLC)

IOE-01 5 PTC temperature sensor inputs 1


Temperature transducers

IOE-02 5 Pt-100 temperature sensor inputs 1

IOE-03 5 KTY84 temperature sensor inputs 1

Incremental encoder module


ENC-01 5 to 12 V dc (built-in power supply) 100 kHz 2
Encoder interface

With encoder signal repeater (external power supply required)

Incremental encoder module


ENC-02 5 to 12 V dc (built-in power supply) 2
100 kHz

Blank Cover - HMID - 011)


Blank cover to replace the standard HMI when not used.
Note: 1) This optional item must be installed at the factory and the orders must specify the desired option in
the product coding (page 16).

Frame for Remote HMI - RHMIF-01


Frame to install the HMI on panel door or machine consoles. IP56 protection
rating.

24 CFW11 - Variable Speed Drives


www.weg.net

Reference Description Slot Image

RS485-01 RS485 serial communication module (Modbus-RTU) 3

RS232-01 RS232 serial communication module (Modbus-RTU) 3

CAN/RS485-01 CAN/RS485 interface module (CANopen, DeviceNet, Modbus-RTU and BACnet) 3

CAN-01 CAN interface module (CANopen and DeviceNet) 3

PROFIBUS DP-01 Profibus-DP-V1 interface module 3

ETHERCAT-05 EtherCAT interface module 4

PROFDP-05 Profibus-DP-V1 module (Anybus-CC) 4

DEVICENET-05 DeviceNet module (Anybus-CC) 4


Communication

RS232-05 RS232 interface module (passive) (Modbus-RTU) 4

RS485-05 RS485 interface module (passive) (Modbus-RTU) 4

Interface module Modbus-TCP - 1 port 4

MODBUSTCP-05

Interface module Modbus-TCP - 2 ports 4

PROFINET IO interface module (Anybus-CC) - 1 port 4

PROFINETIO-05

PROFINET IO interface module (Anybus-CC) - 2 ports 4

EtherNet/IP interface module - 1 port 4

ETHERNETIP-05

EtherNet/IP interface module - 2 ports 4

PLC11-01 Module with PLC functions (see page 26)


PLC Functions

1, 2 and 3

PLC11-02 Module with PLC functions (see page 26)

CFW11 - Variable Speed Drives 25


www.weg.net

Accessories

PLC11
The PLC11 accessory provides the CFW11 with PLC functionalities, such as network master, speed reference generator and
motion control functions.
It has two versions: PLC11-01 and PLC11-02 (see the differences below). In many applications, these accessories enable the
CFW11 to replace an external PLC, reducing costs.

Installation of the PLC module in the CFW11 PLC11 module

Resources
J Motion control with trapezoidal “S” profiles (absolute and J Master/Slave function (electronic gearbox)
relative) J CAN interface for CANopen and DeviceNet protocols
J Search for the machine home position (homing) J Modbus-RTU Master and CANopen Master, which enables
J Ladder programming through the WLP software with the CFW11 to control up to 25 slave devices
timers, counters, coils and contacts J WLP/WSCAN software: network programming and
J RS485 serial interface with Modbus-RTU protocol configuration software in the same environment
J 100 configurable parameters available to the user through

the HMI or WLP

Technical Data
J Digital inputs J RS485 interface J CANopen interface
J Digital outputs J Encoder interface inputs J Analog outputs
J Relay output

PLC11-01 PLC11-02
J 9 bi-directional inputs 24 V J 4 isolated bi-directional inputs 24 V

J 3 bi-directional open collector outputs: 24 V dc, 500 mA J 3 bi-directional open collector outputs: 24 V dc, 500 mA

J 3 outputs for NO contacts: 250 V ac, 3 A J 1 output for NO contacts: 250 V ac, 3 A

J 2 incremental encoder inputs 5...12 V dc, 500 mA (built-in J 2 incremental encoder inputs 5...12 V dc, 500 mA (built-in

power supply) power supply)


J 1 RS485 port (Modbus-RTU available) J 1 RS485 port (Modbus-RTU available)

J 1 CAN port (CANopen available) J 1 CAN port (CANopen and DeviceNet available)

J 1 differential input: -10...+ 10V dc / 0...20 mA, 14 bits

J 2 analog outputs: -10...+10 V dc / 0...20 mA, 12 bits

26 CFW11 - Variable Speed Drives


www.weg.net

Power Cable Shield Kit


The CFW11 has a kit to simplify the connection of the motor cable shield to the ground, allowing a low impedance connection
for high frequencies.

Name Description

PCSA-01 Power cable shield kit for frame A


PCSB-01 Power cable shield kit for frame B
PCSC-01 Power cable shield kit for frame C
PCSD-01 Power cable shield kit for frame D
PCSE-01 Power cable shield kit for frame E

Notes: 1) The PCSD-01, PCSE-01 power cable shield kit is supplied together with inverters with RFI filter
installed at the factory. E.g.: CFW11 0007 T 2 O FA Z.
2) In frames D and E, the power cable shield kit is factory default, even for inverters without built-in
RFI filter.
3) Not available for frames F, G and H.

Cabinets

Stan- Frames
Classification
dards A B C D E F and G H

IP20 - - - X X X X
IEC
IP21 X X X KIP21D-01 - - -
KN1E-01/ KN1F-01/
NEMA Type 1 KN1A-01 KN1B-01 KN1C-01 X -
KN1E-02 KN1G-01
Note: (X) Default
(-) Not available

Default Accessory Composition

KN1A-01 Conduit kit for frame A

KN1B-01 Conduit kit for frame B

KN1C-01 Conduit kit for frame C


NEMA
KN1E-01 Top cover frame E models 105 and 142
Type 1
KN1E-02 Top cover + conduit kit frame E models 180 and 211

KN1F-01 Conduit kit for frame F

KN1G-01 Conduit kit for frame G

KIP21A-01 Top cover kit frame A

KIP21B-01 Top cover kit frame B


IEC
KIP21C-01 Top cover kit frame C

KIP21D-01 Top cover kit frame D

Note: In the KN1X-01 conduit kit (frames A, B and C), the power cable shield is also supplied.

DBW03 and DBW04 Dynamic Braking Module


The DBW03 and DBW04 braking modules can be used in applications involving high-
inertia loads that require fast deceleration, dissipating the braking energy through an
external resistor and keeping the voltage level on the DC link within the limits. The DBW
braking modules have been developed to allow dynamic braking in F, G and H size
inverters.

Model of the braking module

Inverters frame F and G DBW03 0380 D 3848SZ DBW03 0250 D 5069SZ

Inverters frame H DBW04 0380 D 3848SZ DBW04 0250 D 5069SZ

Effective braking current 380 A 250 A

Minimum resistor 1,8 Ω 2,6 Ω

Auxiliary power supply for fan 220 V ac ±5% - 250 mA

CFW11 - Variable Speed Drives 27


www.weg.net

Optional items

Safe Torque Off (STO) Module


Category 3/PLd and SIL CL2, according to EN ISO 61800-5-2, EN ISO 13849-1,
IEC 62061 and IEC 61508 Parts 1-7 and IEC 60204-1.
When the function is activated, the PWM pulses are blocked. Since torque is not
applied to the motor, it is ensured that it remains still, providing safety to the system.

Control External Power Supply at 24 V dc1)


Used with communication networks (Profibus-DP, DeviceNet, EtherNet/IP, etc.) so that
the control circuit and interface to the communication network still work, even with the
removal of the electric power (AC power supply).

RFI Suppressor Filter1) (Compliant with EN 61800-3 and EN 55011)


CFW11 Models with built-in RFI filter, when properly installed, meet the requirements of the
EMC Directive 2004/108/EC, as they attenuate high frequency noise (> 150 kHz) generated
by the variable speed drive and injected in the power line.
Example: CFW11 0007 T 2 O FA Z.
For frames A to D, the RFI filter is optional. For frames E, F, G and H, the RFI filter is
included as standard item.

Note: 1) Those optional items must be installed at the factory and the orders must specify the desired option in the product coding (page 16).

28 CFW11 - Variable Speed Drives


www.weg.net

Dimensions and Weights

Standard Version

Dimensions mm Weight kg
Frame
Height (H) Width (W) Depth (D) 200-240 V ac 380-480 V ac 500-690 V ac
A 270 145 227 6.3 6.3 -
B 316 190 227 9.1 10.4 9.1
C 405 220 293 17.9 20.5 19.6
D 550 300 305 31.4 32.6 34
E 675 335.2 358.2 65 65 64
F 1,234 430 360 - 140 168
G 1,264 535 426 - 215 258
H 1,414 686 420.8 - 220 213

IP55/NEMA12 version

D W

Dimensions mm
Frame Weight kg
Height (H) Width (W) Depth (D1) Depth (D2)
B 529 273 237 279 17.0
C 670 307 306 348 30.0
D 754 375 301.3 339 49.0
E 1,000 430 388,8 419 65.0

D1 = Depth of the models without built-in switch disconnector.


D2 = Depth of the models with built-in switch disconnector.

CFW11 - Variable Speed Drives 29


www.weg.net

Mechanical Assembly

Standard Installation Side-by-Side Installation

D D

Minimum mounting distance with top cover


Frame
A mm B mm C mm D mm
A 25 25 10 30
B 40 45 10 30
B
C 110 130 10 30
D 110 130 10 30
E 150 250 20 80
F, G and H 150 250 20 80
C
Notes: When a variable speed drive is mounted over another, use the distance A + B and divert the hot air
from the inverter.
For frames A, B and C: it is possible to mount the inverters side by side, without lateral spacing. In
this case, the top cover should be removed.

Mechanical Installation and Panel Mounting


Surface Mounting
a2 b2 c2 a2 a2
Protection
Frame
rating mm mm M
A IP2X 115 250 M5
IP2X 150 300 M5 a2
B
IP55 200 505 M8 b2
IP2X 150 375 M6
C
IP55 200 642 M8 b2
IP2X 200 525 M8
D
IP55 250 725 M8 øc2
øc2
IP2X 200 650 M8
E
IP55 150 970 M8 Frames A, B, C and D Frames E (IP55), F,
F IP2X 150 1,200 M10 (IP2X and IP55) and E G and H
G IP2X 200 1,225 M10 (IP2X)
H IP2X 175 1,350 M10

Flange Mounting
a3 b3 c3 d3 e3
Frame a3
mm mm M mm mm
A 130 240 M5 135 225
B 175 285 M5 179 271
C 195 365 M6 205 345 b3 e3

D 275 517 M8 285 485


d3
E 275 640 M8 315 615
F 350 1,185 M10 391 1,146 øc3

G 400 1,220 M10 495 1,182


H 595 1,345 M10 647 1,307

Notes: For frames A to D, the area of the inverter outside the panel has IP54 protection rating.
For frames E (models 180T2, 211T2, 180T4 and 211T4), F and G, the area of the inverter outside the panel has IP54 protection rating (hardware
version H1).
For frame H, the area of the inverter outside the panel has IP20 protection rating.

30 CFW11 - Variable Speed Drives


www.weg.net

Block Diagram - Frames A to G

2
1 = DC bus connection
2 = Connection for braking resistor

Pre-charge
Power
Supply

Motor
Three-phase Capacitor Bank Inverter
Rectifier with IGBT
transistor

PE RFI Filter

DC Bus (DC Link)


PE
Feedbacks:
POWER -Voltages
-Current

Sources for electronics and interfaces


between power and control

SuperDrive G2 and USB


WLP softwares
Accessories

I/O Expansion
(Slot 1 White)

Encoder Interface
(Slot 2 Yellow)

HMI (remote)

HMI CC11
Control COMM1
Card (Slot 3 Green)
with
Digital Inputs 32-bit
(DI1 to DI6) Risc
CPU
COMM2
(Anybus) (Slot4)
Analog Inputs
(AI1 and AI2)

Analog Outputs
Flash
Memory
Module
Digital Outputs
DO1 (RL1) to
DO3 (RL3)

CONTROL

Notes: 1) Available from frame G.


2) Brake IGBT available in frames A to D and E (in versions with built-in brake IGBT). In frames F, G and H, it is necessary to use a dynamic braking module
(external accessory).
3) Standard RFI filter for sizes E, F, G and H.
For further information, refer to the user’s manual.
CFW11 - Variable Speed Drives 31
www.weg.net

Block Diagram - Frame H


1

DC+ DC-

1 = DC link connection and


dynamic braking module
(external accessory)

R1
Pre-charge
S1
Power
Supply
T1
Motor
Three-phase Capacitor Bank Inverter
Rectifier with IGBT
transistor

PE
RFI Filter
R2
Pre-charge
S2 PE
Power
Supply
T2

Three-phase
Rectifier

DC Bus (DC Link)

PE
POWER

Sources for electronics and interfaces


between power and control

SuperDrive G2 and USB


WLP softwares
Accessories

/O Expansion
(Slot 1 White)

Encoder Interface
(Slot 2 Yellow)

HMI (remote)

HMI CC11
Control COMM1
Card (Slot 3 Green)
with
Digital Inputs 32-bit
(DI1 to DI6) RISC
COMM2
(Anybus) (Slot4)
Analog Inputs
(AI1 and AI2)

Analog Outputs
(AO1 and AO2)
Flash
Memory
Module
Digital Outputs
DO1 (RL1) to
DO3 (RL3)

CONTROL

Notes: 1) Available from frame G.


2) Brake IGBT available in frames A to D and E (in versions with built-in brake IGBT). In frames F, G and H, it is necessary to use a dynamic braking module
(external accessory).
3) Standard RFI filter for sizes E, F, G and H.
For further information, refer to the user’s manual.

32 CFW11 - Variable Speed Drives


www.weg.net

Technical Data

Power supply and power range Protection rating


220-240 V ac (+10%, -15%) Standard for frames A, B, C.
Single-phase IP21 For frame D the top cover kit should be added.
(2 to 3 HP) 1.5 to 2.2 kW
Option not available for frames E, F, G and H.
220-240 V ac (+10%, -15%)
(2 to 75 HP) 1.5 to 55 kW Standard for frames D, E, F, G and H.
IP20
In frames A, B and C, the top cover must be removed.
Voltage and 380-480 V ac (+10%, -15%)
NEMA1 Standard for frame D. Optional for frames A, B, C, E, F, and G.
power range (2 to 850 HP) 1.5 to 630 kW
Three-phase IP55/NEMA12 Optional for frames B, C, D and E.
500-600 V ac (+10%, -15%)
(2 to 850 HP) 1.5 to 630 kW
Braking methods
660-690 V ac (+10%,-15%)
(3 to 850 HP) 2.2 to 630 kW Available with built-in IGBT braking or external module
Dynamic braking (DBW03 or DBW04)
Frequency 50/60 Hz (+/-2%: 48 to 63 Hz)
External braking resistor (not supplied)
0.94 for models with three-phase input in
Optimal braking No braking resistor required
the rated condition
Typical input power factor DC braking Direct current applied to the motor
0.70 for models with single-phase input
in the rated condition
Performance
Cos φ (displacement factor) Above 0.98
Regulation: 1% of the rated speed
Efficiency Above 0.97 V/F
Speed variation range: 1:20
Inverter output Regulation: 1% of the rated speed
Voltage vector
Voltage range Three-phase, 0 V up to the supply voltage (VVW) Speed variation range: 1:30
Frequency range 0 to 3.4x rated motor frequency1) Regulation: 0.5% of the rated speed
Sensorless
Standard: 5 kHz (frames A, B, C, D); vector Speed variation range: 1:100
Speed control
Switching frequency 2.5 kHz (frame E); 2 kHz (frames F, G and H)
Available options 2.5 / 5 / 10 kHz Regulation: ±0.01% of the rated speed
with 14-bit analog input (IOA)
110% for 1 min every 10 min Vector with
Normal Duty (ND): encoder Regulation: ±0.01% of the rated speed with
150% for 3 s every 10 min (assynchronous or digital reference (keyboard, serial fieldbus,
Overload permanente electronic potentiometer, multispeed)
Heavy overload duty 150% for 1 min every 10 min
magmet motor)
(HD): Regulation: ±0.05 % of the rated speed
200% for 3 s every 10 min with 12-bit analog input
Acceleration 0 to 999s Vector with encoder
Time (ramps)
Deceleration 0 to 999s (assynchronous Range: 10 to 180%
motor and
permanente magmet
Environment motor) or sensorless
Frame A...D IP20, Torque control (permanente Regulation: ±5% of the rated torque
-10...60 °C (above 50 °C, current magmet motor)
IP21 and UL type 1
derating is necessary)
(NEMA1)
Sensorless vector Range: 20 to 180%
Frame E IP20, IP21 (assynchronous
and UL type 1 Regulation: ±10% of the rated torque
motor)
(NEMA1) (above 3 Hz)
-10...55 °C (above 45 °C, current
All models of Fra- derating is necessary) Inputs and outputs (I/Os) in the standard product
Operating me F and G, IP20
temperature except for 720T4 Digital 6 isolated inputs, 24 V dc, programmable functions
and 760T4
2 isolated differential inputs by the differential
Models 720T4 and amplifier, programmable functions
-10...55 °C (above 40 °C, current
760T4 (Frame G) Resolution
derating is necessary)
and all Frame H AI1: 12 bits
Inputs
Frame B...E IP55 / Analog AI2: 11 bits + signal
-10...50 °C (above 40 °C, current
UL type 12 Signals: 0 to 10 V dc, 0 to 20 mA or 4 to 20 mA
derating is necessary)
(NEMA 12)
Impedance
Humidity 5 to 95% non-condensing 400 kΩ for 0 to 10 V dc signal
500 Ω for 0 to 20 mA or 4 to 20 mA signal
Up to 1,000 m - rated conditions
From 1000 m to 4000 m with current 3 relay outputs with NO/NC contacts,
Relay
Altitude derating (1% for each 100 m above 1000 m) 240 V ac / 2 A, programmable functions
From 2000 to 4000 m - current derating 2 isolated outputs, programmable functions
of 1.1% for each 100 m above 2000 m
Outputs Resolution: 11 bits
Note: 1) This maximum value may change according to the control mode and Analog
Load:
switching frequency. The maximum allowable speed is 18,000 rpm. 0 to 10 V: RL >= 10 kΩ
0 to 20 mA or 4 to 20 mA: RL < 500 Ω
Power supply available to the user 24 V dc + -20%, 500 mA

CFW11 - Variable Speed Drives 33


www.weg.net

Technical Data

Communication Mechanical construction standards


PROFIBUS-DP-01 (slot 3) EN 60529 - Degrees of protection provided by enclosures (IP Code)
Profibus-DP
PROFDP-05 (slot 4)
UL 50 - Enclosures for electrical equipment
CAN/RS485-01 (slot 3)
IEC60721-3-3 - Classification of environmental conditions - part 3: classification of
DeviceNet CAN-01 (slot 3) groups of environmental parameters and their severities - section 3: stationary use at
weatherprotected locations
DEVICENET-05 (slot 4) Level: 3M4
ETHERCAT-05 (slot 4)
EtherCAT
Special Ve 65.84 firmware required Protections
CAN/RS485-01 (slot 3) Overcurrent/short circuit
CANopen
CAN-01 (slot 3) Under/overvoltage on the power circuit
CANopen and Phase loss
Modbus-RTU PLC11-01 and PLC11-02 (slots 1, 2 and 3)
master/slave Overtemperature on the inverter (IGBTs, rectifier and internal air on the electronic boards)

1 port: ETHERNETIP-05 Motor overtemperature


EtherNet/IP 2 ports: ETHERNETIP-2P-05
Overload on the braking resistor
(slot 4)
Overload on the IGBTs
1 port: MODBUSTCP-05
Modbus-TCP 2 ports: MODBUSTCP-2P-05 Motor overload
(slot 4)
External Fault/Alarm
PROFINET IO 2 ports: PROFINETIO-05 (slot 4)
Fault on the CPU or memory
CAN/RS485-01 (slot 3)
BACnet Phase-ground short circuit in the output
Special Ve 5.3X firmware required.
Fault of the heatsink fan
RS485-01 (slot 3)
Motor overspeed
Modbus-RTU (RS485) CAN/RS485-01 (slot 3)
Incorrect encoder connection
RS485-05 (slot 4)
RS232-01 e RS232-02 (slot 3) Electromagnetic compatibility standards (EMC)
Modbus-RTU (RS232)
RS232-05 (slot 4) EN 61800-3 - Adjustable speed electrical power drive systems Part 3: EMC product
Built-in the standard product standard including specific test methods

Communication with SuperDrive G2 software EN 55011 - Limits and methods of measurement of radio disturbance characteristics of
USB industrial, scientific and medical (ISM) radio-frequency equipment
Communication with WLP software used for programming and
monitoring the SoftPLC function and PLC11 CISPR 11 - Industrial, scientific and medical (ISM) radio-frequency equipment
Electromagnetic disturbance characteristics Limits and methods of measurement
EN 61000-4-2 - Electromagnetic Compatibility Standards (EMC) Part 4: Testing and
Safety standards measurement techniques - Section 2: Electrostatic discharge immunity test
Safety standards EN 61000-4-3 - Electromagnetic Compatibility Standards (EMC) Part 4: Testing and
UL 840: Insulation coordination including clearances and creepage distances for electrical measurement techniques - Section 3:Radiated, radiofrequency, electromagnetic field
equipment immunity test

EN 61800-5-1: Safety requirements electrical, thermal and energy EN 61000-4-4 - Electromagnetic Compatibility Standards (EMC) Part 4: Testing and
measurement techniques - Section 4: Electrical fast transient / burst immunity test
EN 50178: Electronic equipment for use in power installations
EN 61000-4-5 - Electromagnetic Compatibility Standards (EMC) Part 4: Testing and
EN 60204-1: Safety of machinery. Electrical equipment of machines. measurement techniques - Section 5: Surge immunity test
Part 1: General requirements.
Note: In order to have a machine in accordance with this standard, the manufacturer of EN 61000-4-6 - Electromagnetic Compatibility Standards (EMC) Part 4: Testing and
the machine is responsible for installing an emergency stop device and a device for measurement techniques - Section 6: Immunity to conducted disturbances, induced by
disconnection from the power line. radio-frequency fields

EN 60146 (IEC 146): Semiconductor converters EN 61000-4-11 - Testing and measurement techniques - Voltage dips, short interruptions
and voltage variations immunity tests
EN 61800-2: Adjustable speed electrical power drive systems - Part 2: General requirements
- rating specifications for low voltage adjustable frequency a.c. power drive systems

34 CFW11 - Variable Speed Drives


www.weg.net

Global presence is essential,


as much as understanding your needs.

Global Presence
With more than 30.000 employees worldwide, WEG is one of the largest electric motors, electronic equipments and systems
manufacturers. We are constantly expanding our portfolio of products and services with expertise and market knowledge. We
create integrated and customized solutions ranging from innovative products to complete after-sales service.

WEG’s know-how guarantees our Variable Speed Drive is the right choice for your application and business, assuring safety,
efficiency and reliability.

Availability is to have a global support network

Partnership is to create solutions that suit your needs

Competitive edge is to unite technology and innovation

Know More
High performance and reliable
products to improve your
production process.

Excelence is to provide a whole solution in


industrial automation that improves
our customers productivity.

Visit: www.weg.net youtube.com/wegvideos

CFW11 - Variable Speed Drives 35


For WEG’s worldwide
operations visit our website

www.weg.net

+55 47 3276.4000

[email protected]

Jaraguá do Sul - SC - Brazil


AUTOMATION

Cod: 50019076 | Rev: 27 | Date (m/a): 08/2021.


The values shown are subject to change without prior notice.
The information contained is reference values.