MTC Controller (Rev 1.7)
MTC Controller (Rev 1.7)
1.Main Features
¾ 8 Relays
¾ 5-Down Collective Stops
¾ 10 Stops in Switching mode
¾ 10 Stops in Simplex mode
¾ 4 Stops Full Collective mode
¾ Xon and 3 Safety Inputs
¾ PTC Input
¾ External LCD for programming
¾ 7-Segment Output active low with arrow Up and arrow Down*
¾ Gray/Binary Indicator active low with arrow Up and arrow Down
¾ Decimal Indicator active low with arrow Up and arrow Down*
¾ 12 Input terminals
¾ 10 Calls Terminals
¾ RJ45 for external LCD programming tool.
*
Arrow UP & Arrow Down are not active in switching mode.
2
3
4
5
Main Screen:
E MTC BOARD 0
INSP FL = --
LMTUP = 0 LMTDN = 0 DO
PRM ERR FN
To go to the parameter screen, you must enter the password, so press on PRM button.
This will appear on the screen:
MTC BOARD
Password= 00000000
6
When you enter the password, this will appear on the screen:
Parameter screen:
E MTC BOARD 0
Floor Stop Timer 01
Value= 03 sec
When you are in the parameter screen, press on SELECT button until the value blinks
to change the parameter value. This will appear on the screen:
E MTC BOARD 0
Floor Stop Timer 01
Value= 03 sec
OK DEC INC
7
MTC BOARD
00- Last fault
01- Fault2
E MTC BOARD 0
FL CALL
SDN SUP 00 00
8
Press on SDN or SUP to enter the Inspection page. This will appear on the screen.
Inspection page:
E MTC BOARD 0
To go to the main screen keep pressing on Exit button. This will appear on the screen
Main Screen:
E MTC BOARD 0
INSP FL = --
LMTUP = 0 LMTDN = 0 DO
PRM ERR FN
9
4. List of Parameters
Parameters
Parameter Parameters Full Default
Description on Values Range
Numbers Description Values
LCD
Time between travels
01 Floor Stop Timer 3 sec 1 Æ 255 sec
in sec
0=Swinging
02 Door Type Type of the door Swinging 1=Automatic
None
03 Level Zone Level of each floor None Installed NC
Installed NO
05 Basements Basement counts 0 0Æ9
Floor of which the
06 Home Floor 0 0…Last floor
station is on
Time out to go home
07 Home Floor Timer 0 sec 1 Æ 255 min
floor
Multi calls anybody
08 No Load 0 1Æ9
open door
Switch between
0= Full
09 Collective Down and Full Down
1= Down
collective
If enabled, make a
10 Homing on Power Enable Enable/Disable
home trip at start up
11 Truncate Empty the fault log N /A
Automatic Door
OPN/CLS Door The time of the open
12 Time
6 sec 0 Æ 31 sec
or close
The status of the door
13 Parking Stat Door when reach the Close Close/Open
station
15 Light Time Cabin light timer 5 sec 1 Æ 60 sec
Keep door active
16 Keep Close Disable Enable / Disable
during travel
Secondary
17 Retry Gamma Number of retry 3 0 Æ 10 times
Retry Gamma
18 Gamma retry timer 3 0Æ 30 sec
Timer
10
Parameters
Parameter Parameters Full Default
Description on Values Range
Numbers Description Values
LCD
To enter negative 0= Disable
19 Negative Output 0
signal for 7-Segment 1= Enable
After the magnet
timeout has passed
20 Pulse Timeout 20 sec 1 Æ 99 sec
then the elevator will
block
Retry yale time to
21 Yal Timer 5 sec 1 Æ 60 sec
next retry delay in sec
Reactive Gamma
22 PTC – NTC when level zone is NTC NTC/PTC
reached
16: Up to 5 stops
Down collective
17: Up to 10 stops
Down Collective
Switching mode
64: Up to 10 stops
not collective
24 Floor Expansion Floor Expansion 16
with lighting
the request
96: Up to 10 stops
Simplex mode
128: up to 10 stops
Collective
11
Parameters
Parameter Parameters Full Default
Description on Values Range
Numbers Description Values
LCD
Hydraulic and VVVF Elevator
VVVF Hy Stp Dly: Specify the stop
37 VVVF Hydraulic delay for Hydraulic or 0 0 Æ 50 in 100 ms
Stop Delay VVVF
Specify brake to turn
VF HY Strt Dly:
38 of after time finished 0 0 Æ 50 in 100 ms
VVVF Start Delay
at startup elevator
V- Hi Spd Flr: Specified when we
39 VVVF high Speed can turn to super 4 4Æ9
Floor high speed
Specified when turn
Hi 2Md Spd Flr: to med speed after
40 2 2Æ5
VVVF Med Speed reach the request
floor
Very high speed
41 Spar2 Output Inspection Inspection/Brake
output
Specify Hydraulic
42 Hydra Start Time start time after 0 0 Æ 99
converting to delta
The maximum
Passenger number of Cabin
44 0 1 Æ 15
Capacity calls to ignore
outside calls
0= AC2 Speed
1= VVVF ABB350
2= Hydraulic
3= VVVF Standard
AC2
45 Drive /VVVF Type Type of engine 4= VVVF 3-Speed
Speed/Hyd
5= VVVF Fuji
2-Speed
6= VVVF Fuji
12
Parameters
Parameter Parameters Full Default
Description on Values Range
Numbers Description Values
LCD
Makes delay at stop
56 Fuji Ena Delay for enable inverter 0 0 Æ 30
output
1. Dis: Disable relevel
2. SEL: works only
when door is close
57 RVL Relevel Option All 3. All: work when
door is close or
open
13
5. Indicator Connections
7-Segment Indicator (Active Low)
INDICATOR 7 segment
+22vdc +
+22vdc
|
^
|
^
- G F E D C B A
Hall Car
(-) (-) MTC Board Controller
Labels on the board
Note: In case of switching mode arrow up & arrow down are not active.
INDICATOR
BINARY/GRAY
^
|
|
^
D C B A
G F
Labels on the board
Note: In case of switching mode arrow up & arrow down are not active.
14
6. Input Connections
15
16
17
18
19
20
21
22
23
24
25