MTC Controller (Rev 1.7)

The document describes the features and operation of an MTC board controller. It lists the main features, input/output terminals, and provides instructions on how to access programming screens and change parameter values.

Uploaded by

ahmed morsy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 26

1

‘ƒ”†‘–”‘ŽŽ‡”

1.Main Features

¾ 8 Relays
¾ 5-Down Collective Stops
¾ 10 Stops in Switching mode
¾ 10 Stops in Simplex mode
¾ 4 Stops Full Collective mode
¾ Xon and 3 Safety Inputs
¾ PTC Input
¾ External LCD for programming
¾ 7-Segment Output active low with arrow Up and arrow Down*
¾ Gray/Binary Indicator active low with arrow Up and arrow Down
¾ Decimal Indicator active low with arrow Up and arrow Down*
¾ 12 Input terminals
¾ 10 Calls Terminals
¾ RJ45 for external LCD programming tool.
*
Arrow UP & Arrow Down are not active in switching mode.

2
3
‘ƒ”†‘–”‘ŽŽ‡”

2.1 Input Terminals




¾ 1: Magnetic switch Up direction
¾ 2: Magnetic switch Down direction
¾ 3: Limit switch Up direction
¾ 4: Limit switch Down direction
¾ 5: Service enable
¾ 6: Safety 1
¾ 7: Close Circuit
¾ 8: Auxiliary ON contactor for UP/DN direction
¾ 9: Safety 2
¾ 10: Limit switch end of closing
¾ 11: Limit switch end of opening
¾ 12: Safety 3
¾ 13: Motor PTC
¾ 14: Ground
¾ 17 VAC: Board power supply = 17vac

2.2 Call Terminals



¾ 0F: Floor 0 call (Service DOWN is CALL 0F in Inspection mode)
¾ 1F: Floor 1 call (Service UP is CALL 1F in Inspection mode)
¾ 2F: Floor 2 call
¾ 3F: Floor 3 call
¾ 4F: Floor 4 call
¾ 5F: Floor 5 call
¾ 6F: Floor 6 call
¾ 7F: Floor 7 call
¾ 8F: Floor 8 call
¾ 9F: Floor 9 call

4
‘ƒ”†‘–”‘ŽŽ‡”

2.3 Output Terminals for AC2 speed and VVVF




¾ (-) 22 V: Biasing voltage from periphery supply –negative side
¾ (+) 22V: Biasing voltage from periphery supply – positive side
¾ CLSE CAM: Cam contactor / Close relay or contactor
¾ OPEN: Open door relay or contactor
¾ COM2: Common 2 for CLSE CAM and OPN
¾ HIGH: High speed contactor
¾ DOWN: Down direction contactor
¾ SLOW: Low speed contactor
¾ COM1: Common 1 for HI, LOW,UP, DOWN, and SPARE
¾ UP: Up direction contactor
¾ SPR: Spare output
¾ LITE: Car light relay
¾ COM LITE: Common for LITE output

2.4 Indicator Output Terminals



¾ A
¾ B
¾ C
¾ D
¾ E
¾ F
¾ G
¾ 1
¾ CAR (-): Arrow Down
¾ CAR (+): Not used
¾ HALL (-): Arrow UP
¾ HALL (+): Not used

5
‘ƒ”†‘–”‘ŽŽ‡”

3. How to enter the PARAMETER Screen



When the MTC board is powered up with 17 VAC, the main screen appears in this form

Main Screen:

E MTC BOARD 0
INSP FL = --
LMTUP = 0 LMTDN = 0 DO

PRM ERR FN

To go to the parameter screen, you must enter the password, so press on PRM button.
This will appear on the screen:

MTC BOARD

Password= 00000000

OK NEXT DEC INC

¾ To decrease each digit, press on DEC button.


¾ To increase each digit, press on INC button.
¾ To move from one digit to another, press on NEXT button.
¾ To save the password, press on OK button.
The password is 00000000

6
‘ƒ”†‘–”‘ŽŽ‡”

When you enter the password, this will appear on the screen:

Parameter screen:

E MTC BOARD 0
Floor Stop Timer 01
Value= 03 sec

SELECT EXIT PREV NEXT

NEXT: It is used to scroll between parameters in increasing order.


PREV: It is used to scroll between parameters in decreasing order.
EXIT : It is used to exit the parameter page.
SELECT: It is used to change the parameter value.

3.1 How to change the value of a parameter

When you are in the parameter screen, press on SELECT button until the value blinks
to change the parameter value. This will appear on the screen:

E MTC BOARD 0
Floor Stop Timer 01
Value= 03 sec

OK DEC INC

¾ To increase the value of the parameter, press on INC button


¾ To decrease the value of the parameter, press on DEC button
¾ To save the value of the parameter, press on OK button.

7
‘ƒ”†‘–”‘ŽŽ‡”

3.2 How to enter the Error screen


When you are in the main screen, press on ERR button to enter the Error screen.
This will appear on the screen:

MTC BOARD
00- Last fault
01- Fault2

Exit DEC INC

¾ To increase the fault, press on INC button


¾ To decrease the fault, press on DEC button

3.3 How to enter the Function screen


When you are in the main screen, press on FN button to enter the Function screen.
This will appear on the screen:

E MTC BOARD 0

FL CALL

SDN SUP 00 00

¾ Press on INC button to increase the Call.


¾ Press ob DEC button to decrease the Call.

8
‘ƒ”†‘–”‘ŽŽ‡”

Press on SDN or SUP to enter the Inspection page. This will appear on the screen.

Inspection page:

E MTC BOARD 0

SDN SUP Exit

To go to the main screen keep pressing on Exit button. This will appear on the screen

Main Screen:

E MTC BOARD 0
INSP FL = --
LMTUP = 0 LMTDN = 0 DO

PRM ERR FN

9
‘ƒ”†‘–”‘ŽŽ‡”

4. List of Parameters
Parameters
Parameter Parameters Full Default
Description on Values Range
Numbers Description Values
LCD
Time between travels
01 Floor Stop Timer 3 sec 1 Æ 255 sec
in sec
0=Swinging
02 Door Type Type of the door Swinging 1=Automatic
None
03 Level Zone Level of each floor None Installed NC
Installed NO
05 Basements Basement counts 0 0Æ9
Floor of which the
06 Home Floor 0 0…Last floor
station is on
Time out to go home
07 Home Floor Timer 0 sec 1 Æ 255 min
floor
Multi calls anybody
08 No Load 0 1Æ9
open door
Switch between
0= Full
09 Collective Down and Full Down
1= Down
collective
If enabled, make a
10 Homing on Power Enable Enable/Disable
home trip at start up
11 Truncate Empty the fault log N /A

Automatic Door
OPN/CLS Door The time of the open
12 Time
6 sec 0 Æ 31 sec
or close
The status of the door
13 Parking Stat Door when reach the Close Close/Open
station
15 Light Time Cabin light timer 5 sec 1 Æ 60 sec
Keep door active
16 Keep Close Disable Enable / Disable
during travel
Secondary
17 Retry Gamma Number of retry 3 0 Æ 10 times
Retry Gamma
18 Gamma retry timer 3 0Æ 30 sec
Timer

10
‘ƒ”†‘–”‘ŽŽ‡”

Parameters
Parameter Parameters Full Default
Description on Values Range
Numbers Description Values
LCD
To enter negative 0= Disable
19 Negative Output 0
signal for 7-Segment 1= Enable
After the magnet
timeout has passed
20 Pulse Timeout 20 sec 1 Æ 99 sec
then the elevator will
block
Retry yale time to
21 Yal Timer 5 sec 1 Æ 60 sec
next retry delay in sec
Reactive Gamma
22 PTC – NTC when level zone is NTC NTC/PTC
reached
16: Up to 5 stops
Down collective
17: Up to 10 stops
Down Collective
Switching mode
64: Up to 10 stops
not collective
24 Floor Expansion Floor Expansion 16
with lighting
the request
96: Up to 10 stops
Simplex mode
128: up to 10 stops
Collective

Specify the hall and Gray/Binary/


26 Indicator type Gray
car display type 7-Segment/Decimal

Disable: Disable limit


Switch during
LMT SW During Limit Reopen During inspection
30 Enable
INS Inspection
Enable: Enable limit
Switch during
inspection
31 Count of Days Days of operation 0000 0000
Name of the
32 Company Name MTC Board N/A
company
The serial number of
34 Serial Number 154 N/A
the board
The Hardware
35 Hardware Version MTC N/A
version of the board
The Firmware version
36 Firmware Version FV N/A
of the board

11
‘ƒ”†‘–”‘ŽŽ‡”

Parameters
Parameter Parameters Full Default
Description on Values Range
Numbers Description Values
LCD
Hydraulic and VVVF Elevator
VVVF Hy Stp Dly: Specify the stop
37 VVVF Hydraulic delay for Hydraulic or 0 0 Æ 50 in 100 ms
Stop Delay VVVF
Specify brake to turn
VF HY Strt Dly:
38 of after time finished 0 0 Æ 50 in 100 ms
VVVF Start Delay
at startup elevator
V- Hi Spd Flr: Specified when we
39 VVVF high Speed can turn to super 4 4Æ9
Floor high speed
Specified when turn
Hi 2Md Spd Flr: to med speed after
40 2 2Æ5
VVVF Med Speed reach the request
floor
Very high speed
41 Spar2 Output Inspection Inspection/Brake
output
Specify Hydraulic
42 Hydra Start Time start time after 0 0 Æ 99
converting to delta
The maximum
Passenger number of Cabin
44 0 1 Æ 15
Capacity calls to ignore
outside calls
0= AC2 Speed
1= VVVF ABB350
2= Hydraulic
3= VVVF Standard
AC2
45 Drive /VVVF Type Type of engine 4= VVVF 3-Speed
Speed/Hyd
5= VVVF Fuji
2-Speed
6= VVVF Fuji

To start the indicator


52 First Stop Disable Disable/Enable
from floor 1
NC/ NC
Close Circuit or SEN
NO/NC
54 ClS Circuit/ SEN to work active low or NC/NC
NC/NO
active high
NO/NO

12
‘ƒ”†‘–”‘ŽŽ‡”

Parameters
Parameter Parameters Full Default
Description on Values Range
Numbers Description Values
LCD
Makes delay at stop
56 Fuji Ena Delay for enable inverter 0 0 Æ 30
output
1. Dis: Disable relevel
2. SEL: works only
when door is close
57 RVL Relevel Option All 3. All: work when
door is close or
open

Fact Default: Restore factory


59
Factory Restore settings

13
‘ƒ”†‘–”‘ŽŽ‡”

5. Indicator Connections
™ 7-Segment Indicator (Active Low)

INDICATOR 7 segment
+22vdc +

+22vdc

|
^
|
^
- G F E D C B A

Hall Car
(-) (-) MTC Board Controller
Labels on the board

Note: In case of switching mode arrow up & arrow down are not active.

™ Binary/Gray Indicator (Active Low)

INDICATOR
BINARY/GRAY

^
|
|
^
D C B A
G F
Labels on the board

MTC Board Controller

™ Decimal Indicator (Active Low)

Note: In case of switching mode arrow up & arrow down are not active.

14
‘ƒ”†‘–”‘ŽŽ‡”

6. Input Connections

CDN: Contactor Down direction


CUP: Contactor UP direction
DJ: Door jam switch
PC: Photocell switch
BOP: Bush button to reopen automatic door
OL: Overload switch

15
16
17
18
19
20
21