Dyn - DBS-MC-SD

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Key plan

EXIST
ING
W W PT
12

18

21
18

20
01
6.00

(+6.3
12

12

5)
7.50

11

02

16
6.00

11

13
12

12

22

03
11
6.00

10

09

19
14

04
05

17

15
07

GEN
ROOM
06

07

06

07

06
Outlet of Waste Sludge

07
Outlet of Effluent Outlet of Effluent 15,00

06
12

07
08
DN300 AISI316 DN100 AISI316 SCH 10S DN300 AISI316

06

07
08
15.0013

06
08
12

08
Bioblock Main Air Supply

08
Bioblock Air Supply DN200 AISI304 SCH 10S

08
Blower

23
-0,95
15,00
Equalization Tank
Air Supply Blower

6,20
Notes

+7.00
Wastewater
Feeding Tank GENERAL NOTES
(AISI304)
Monorail for Bioblock
Feeding Pumps Lift
Stainless steel pipes immersed in sewage shall be AISI 316 acc. to
+7,00 Wastewater
Flowmeter
ASTM778, ANSI B36.19 and wall thickness Sched. 10s.
DN150
Stainless steel pipes external to sewage shall be AISI 304 acc. to
Wastewater Discharge Pipe
DN150 AISI316 SCH10S ASTM778, ANSI B36.19 and wall thickness Sched. 10s.
Equalization Tank Air Supply
DETAIL - G DN100 AISI304 SCH 10S All stainless steel Flanges are acc. to DIN 2576

11,50
AIR LIFT No2
(AISI 304)
( 1 : 25 ) All pipe connections on the drawing are indicative. Please refer to
AIR LIFT No1
(AISI 304)
relevant drawings.
Wastewater Feeding Pipe
uPVC 200 PN10
Collection Circular Channel uPVC piping shall be solvent weld on site.
Bioblock Main Air Supply of Clarified Wastewater
(perforated at the bottom) DN200 AISI304 SCH 10S
G 315 HDPE PE100 PN10 For supports of piping please refer to the relevant drawings.
Wastewater Feeding Pipe
uPVC 200 PN10 DN100 AISI304 SCH10S
(perforated at the bottom)) All supports of piping and structures external to sewage shall be
hot dip galvanized.

0,95
Waste Sludge Outlet Wastewater Discharge Pipe
DN100 AISI316 SCH 10S DN150 AISI316 SCH10S +7.00
All supports of piping and structures immersed in sewage shall be
+6.40 AISI304.
+4.15 Equalization Tank
DN125 AISI304
Air Supply
SCH 10S

1,00
Air Supply for Inclined Wall DN200 AISI304 DN65 AISI304 SCH10S
Opening Cleaning SCH 10S
A
DN50 AISI316 SCH 10S
Lifting guide rails for F
24,00

24,00
0,50
0.00 0.00 Bioblock Feeding Pumps
2,50 +0,10 +0,10 DN65 AISI316 SCH10S Wastewater Overflow
+4.15 Pipe DN300
A Equalization Tank Air Supply
uPVC 32 PN16 DETAIL - F +3.80 Sheet Metal Partition
(perforated at the bottom) uPVC 63 ( 1 : 25 ) for Deaeration Zone
Supports for Sheet Metal Partition
PN16 AISI304
of Deaeration Zone AISI304
Wastewater Discharge Pipe
DN150 AISI316 SCH10S

28,50
Air Supply for Inclined Wall
Opening Cleaning
DN50 AISI316 SCH 10S
Equalization Tank
Air Supply
DN65 AISI316 SCH10S
Legend
Collection Circular Channel Collection Circular Channel
of Clarified Wastewater AIR LIFT No1 of Clarified Wastewater Fine Bubble
315 HDPE PE100 PN10 (AISI 304) 315 HDPE PE100 PN10 Disc Diffusers
uPVC 32
uPVC 90 PN16
PN16

0,50
uPVC 110 0.00 E
PN16
uPVC Tee
110 PN16 DYN GN MEC 006----

0,50
11,50
Equalization Tank
D Air Supply
SECTION A-A
uPVC 75 PN16

0,50
0,425 0,425
Air Supply for Inclined Wall Air Supply for Inclined Wall
Opening Cleaning uPVC 90 Equalization Tank
Opening Cleaning Air Supply
uPVC 63 PN16 PN16
uPVC 63 PN16 uPVC 75 PN16
(perforated at the bottom)) (perforated at the bottom) 0,85 0,85

Fine Bubble Equalization Tank


Disc Diffusers Air Supply

0,70
uPVC 63 PN16

0.00

0,10
DETAIL- D
( 1 : 25 )
+7,00 +0,10 +0,10
Connection Flange to Adjacent
Bioblock Air Supply Network DETAIL- E
( 1 : 25 )
DN100 AISI304
SCH 10S
0,15

REV. DATE REMARKS


C
0,70

2,70 3,70 2,30


1,50

0,60
1,70

DN200 AISI304
SCH 10S 1,20 DN80 AISI304 -0,85
1,75
SCH 10S uPVC 63 uPVC 63 uPVC 75
DN150 AISI304 Wastewater 0,825
SCH 10S PN16 PN16 PN16
Feeding Tank B
(AISI 304)
-0,95
3,00

DN65 AISI304

4,00
0,50 1,00 0,50 SCH 10S
Equalization Tank Air Supply
uPVC 32 PN16 1,00 0,70 0,30
(perforated at the bottom) 0.00 0.00 +4,15
0.00 uPVC 32
0,60 0,50 PN16
1,00

Equalization Tank
0,60

0,50

+7,00 Air Supply Blowers C:\Users\tifas\Documents\26.png

Bioblock Air Supply


0,50

Blowers

Wastewater Overflow Bell-mouth for


Bioblock Wastewater Wastewater Inlet
Wastewater Inlet Pipe DN300 Fine Bubble Bioblock Wastewater Wastewater
Wastewater Feeding Pipe Feeding Pumps Pipe DN300
Pipe DN300 Disc Diffusers Feeding Pumps Overflow Pipe
0,35 uPVC 200 PN10
Wastewater Overflow
Waste Sludge Outlet (perforated at the bottom)
SECTION AT +0.50 Fine Bubble
SECTION AT +6.00
DN100 AISI316 SCH 10S
Pipe DN300 Equalization Tank Air Supply A Disc Diffusers
uPVC 32 PN16
TOP VIEW (perforated at the bottom)

0,15 0,70 0,15 Wastewater Feeding Pipe


uPVC 200 PN10 Support for Fine Bubble
(perforated at the bottom) Disc Diffusers - AISI316

Equalization Tank
0,65

Air Supply
uPVC 63 PN16
1,05 0,85 0,85 0,35

0,50
0,20
1,30

uPVC 90
0,35

PN16

0,25
0,60

Air Supply for Inclined Wall


Opening Cleaning
DN50 AISI304 SCH 10S

Bioblock Air Supply Dropleg


BioblockDN125
Main Air Supply
AISI304 SCH 10S
Equalization Tank Air Supply
uPVC 32 PN16 CONTRACTOR
DN200 AISI304 SCH 10S (perforated at the bottom)

DETAIL- B EMAK
( 1 : 25 ) DETAIL- C
DETAIL- A ( 1 : 25 )
( 1 : 25 ) Zero Level = +(5.46)

Client Consultant: TALAAT IMAM


CONSULTING ENGINEERS
11 Sphinx Square - Mohandesin, Giza, Egypt, 12411
Tel: 202 33461888 Fax:202 33036364

DESIGNR

IN ASSOCIATION WITH :
&
DWG.TITLE

PROJ.NAME MAIN DISCIPLINE SHEET TYPE SHEET NO TOTAL SHEETS NO


OF
DYN PR MEC 1 2

DATE SHEET SIZE SCALE REV SERIAL TO TOTAL DRAWINGS NO.

13.10.2020 A1 1 / 100 FINAL 006 089


B Key plan

EXIST
J J

ING
W W PT
12
H H

18

21
18

20
01
6.00

(+6.3
Bioblock Air Supply Wastewater
Equalization Tank

12

12

5)
Blowers Feeding Tank Bioblock Main Air Supply Air Supply Pipe 7.50

11
(AISI 304)

02
DN200 AISI304 SCH 10S Air Supply for Inclined Wall DN100 AISI304 SCH 10S

16
Wastewater

6.00
DN200 AISI304 Bioblock Main Air Supply Opening Cleaning Equalization Tank G G

11
AIR LIFT No1

13
12
SCH 10S DN200 AISI304 SCH10S DN65 AISI304 SCH 10S Feeding Tank

12
Air Supply Blowers

22

03
(AISI 304) Bioblock Air Supply Dropleg (AISI304)
Flow Control

11
DN125 AISI316 SCH 10S AIR LIFT No2 6.00

10
Flow Control

09

19
(AISI 304) Gates AISI304

14

04
Gates AISI304

05

17
H

15
07

GEN
ROOM
06
DN200 AISI316 Condensate Discharge

07
DN65 AISI316

06
+7,00 +7,00 DN25 AISI316 +7,00

07
SCH 10S Flow Control SCH 10S

06

07
SCH 10S F F

0,95
Gates AISI304

06
C

12

07
08

06
+6.50

07
08
Monorail for Bioblock Air Supply Dropleg

06
3 +6.40 +6.40 +6.40 +6.40 +6.40 E E

08
12
Pump Lift DN125 AISI316 SCH 10S

08
+6.00 +7,00

08
0,60 DN100 AISI304

08
Wastewater SCH 10S

23
Flowmeter DN150 uPVC 200 Waste Sludge +5.40
0,20
PN10 +5.30 Discharge Pipe +5.30 Condensate Discharge
DN100 AISI316 SCH 10S DN25 AISI316
SCH 10S Equalization Tank
Equalization Tank Air Supply Air Supply
DN100 AISI304 SCH 10S +6.40
DN65 AISI 304 SCH 10S
Air Vent Pipe
Waste Sludge Outlet D D TOP VIEW
+4,15 DN100 AISI316 +4,15
Notes
uPVC 110 PN10
+3.80 +3.80
GENERAL NOTES
Guide-rails for 3
Pump Lift
Air Lift Suction Pipe
Waste Sludge
Discharge Pipe
DN65 AISI 316 SCH 10S C B Stainless steel pipes immersed in sewage shall be AISI 316 acc. to
Wastewater Discharge Pipe DN80 AISI316 SCH 10S DN100 AISI316 SCH 10S TOP VIEW
DN150 AISI 316 SCH 10S DETAIL- H ASTM778, ANSI B36.19 and wall thickness Sched. 10s.
DN65 AISI 316 +1.80 ( 1 : 25 ) 0,50

SCH 10S +1.80


DN125 AISI316
SCH 10S +1.80 Stainless steel pipes external to sewage shall be AISI 304 acc. to
J
Bioblock Air Supply Dropleg
uPVC 75 DN125 AISI316 SCH 10S
ASTM778, ANSI B36.19 and wall thickness Sched. 10s.
PN16 Equalization Tank Air Supply

1,00
uPVC 32 PN16 All stainless steel Flanges are acc. to DIN 2576
(perforated at the bottom)

Fine Bubble +0,10


All pipe connections on the drawing are indicative. Please refer to
0.00 0.00
Disk Diffusers
+0.60 relevant drawings.

1,00
uPVC piping shall be solvent weld on site.
0,70

-0,95 -0.85 -0,95 -0,95 -0,95

0,30
0,70
For supports of piping please refer to the relevant drawings.

0,40
Wastewater Feeding Pipe

0,30
uPVC 200 PN10 0.00
SECTION B-B (perforated at the bottom)
uPVC 90 Wastewater Feeding Pipe
All supports of piping and structures external to sewage shall be
Equalization Tank Air Supply PN16 uPVC 200 PN10 Bioblock Wastewater
Wastewater Inlet DETAIL- J
Pipe DN300
Bioblock Wastewater
Feeding Pumps DN100 AISI 304 SCH 10S (perforated at the bottom 65mm/3m) Feeding Pumps Overflow Pipe
DN300
hot dip galvanized.
Bioblock Main Air Supply ( 1 : 25 ) SECTION C-C
2,18

Equalization Tank Air Supply DN200 AISI304 SCH 10S All supports of piping and structures immersed in sewage shall be
DN65 AISI 304 SCH 10S
1,20

DN200 AISI304
1,75 2,30 3,70 2,70 AISI304.
+4,15
SCH 10S Connection Flange to Adjacent
Bioblock Air Supply Network
Bioblock Air Supply
DN100 AISI304
Manifold DN200 AISI304 SCH 10S
Equalization Tank SCH 10S
DN200 AISI304
SCH 10S Wastewater
DETAIL SECTION 3 - 3 Air Supply Blowers

Feeding Tank ( 1 : 50 ) AIR LIFT No1


2 2
2,10

2,10
(AISI304) (AISI304)
Bioblock Air Supply

1,06
Blowers
+7,00
0,36

+7,00 +7,00
0,26

Wastewater +6.40 +6.40 +6.40 +6.40


Flowmeter DN150 Equalization Tank Air Supply
Wastewater DN65 AISI 304 DN100 AISI 304 SCH 10S
Discharge Pipe Air Supply for Inclined Wall
SCH 10S Collection Circular Channel Collection Circular Channel Opening Cleaning
DN150 AISI316 SCH 10S of Clarified Wastewater 15.0000 of Clarified Wastewater DN50 AISI316 SCH 10S
315 HDPE PE100 PN10 315 HDPE PE100 PN10

+4,15 DN32 AISI 316

+3.80 +3.80
Air Lift Suction Pipe
DN80 AISI316 SCH 10S
SCH 10S
Legend
DN65 AISI 316
SCH 10S Equalization Tank Air Supply DN125 AISI316
DN65 AISI 316 SCH 10S SCH 10S

uPVC 140
PN16
O
uPVC 200 uPVC 110 DYN GN HY 007----
PN10 PN16
uPVC 75 uPVC 75
PN16 PN16

0,40
uPVC 63 N
PN16 +0,10
M +0,10
0.00 0.00 0.00 0.00
uPVC 90 0,85 0,85 0,35
PN16

-0,95
Air Supply for Inclined Wall
Bioblock Air Supply Manifold Opening Cleaning & Air Lift Pumps +7.00 SECTION F-F Waste Sludge
Air Supply for Air Lift No2 SECTION E-E 0,35
DN200 AISI304 SCH 10S DN65 AISI304 SCH 10S Discharge Pipe
DN32 AISI304 SCH 10S
Air Supply for Inclined Wall DN100 AISI316 SCH 10S
0,15 0,70 0,15
+6.63 Opening Cleaning Needle Valve DN25 DETAIL- O
Bioblock Air Supply Dropleg DN50 AISI316 SCH 10S for air supply ( 1 : 25 )
1 1 SECTION D-D DN125 AISI316 SCH 10S
+6.40
flow regulation
+6.285
Air Vent Pipe +6.20 uPVC 75 PN16 Motorized
uPVC 110 PN10 Ball Valve DN25
0,95

Bioblock Air Supply Dropleg 0,3


DN125 AISI316 SCH 10S Equalization Tank Air Supply 0,31 5
0,50 0,50
0,30 uPVC 32 PN16 Air Supply By-pass
+7.00 0,30 0,10 Collection Circular Channel
+7,00 (perforated at the bottom) 2 Ball Valve DN25

0,70
of Clarified Wastewater
0,15

Wastewater Feeding Pipe 0,1


1,30

0,35
315 HDPE PE100 PN10 Air Supply for Inclined Wall Opening Cleaning +7.00
Sheet Metal Partition +0,10 uPVC 200 PN10
Air Supply for Inclined Wall for Deaeration Zone 0.00 (perforated at the bottom) uPVC 63 PN16
Air Supply for Inclined Wall (perforated at the bottom)
0,65

Opening Cleaning AISI304 - 2mm


Opening Cleaning
DN50 AISI316 SCH 10S
DN50 AISI316 SCH 10S REV. DATE REMARKS
AIR LIFT No1

0,15
0,70 (AISI304)
0,75
Air Supply for Air Lift No1 +4.70 Supports for Sheet Metal Partition
DN32 AISI304 SCH 10S of Deaeration Zone AISI304 DETAIL - M
K
DN65 AISI304 DETAIL- L ( 1 : 25 )
DETAIL SECTION 1-1
SCH 10S DETAIL- N
DETAIL- K ( 1 : 25 ) DETAIL SECTION 2-2
( 1 : 25 )
L ( 1 : 25 )
( 1 : 25 ) +7,00 +7,00 +7,00 ( 1 : 25 )

+6.40 +6.40 +6.40 +6.40 +6.40 +6.40

C:\Users\tifas\Documents\26.png

Condensate Discharge Condensate Discharge


DN25 AISI316 DN25 AISI316
SCH 10S SCH 10S

Air Vent Pipe


uPVC 110 PN10

+1.80
+1.54

+0.60

+0,10 +0,10
0,50

0.00 0.00 0.00

1,00

-0,95
0,50

SECTION G-G SECTION H-H

SECTION J-J Zero Level = +(5.46)


CONTRACTOR

EMAK

Client Consultant: TALAAT IMAM


CONSULTING ENGINEERS
11 Sphinx Square - Mohandesin, Giza, Egypt, 12411
Tel: 202 33461888 Fax:202 33036364

DESIGNR

IN ASSOCIATION WITH :
&
DWG.TITLE

PROJ.NAME MAIN DISCIPLINE SHEET TYPE SHEET NO TOTAL SHEETS NO


OF
DYN PR HY 2 2

DATE SHEET SIZE SCALE REV SERIAL TO TOTAL DRAWINGS NO.

13/10/2020 A1 1 / 100 FINAL 007 089

You might also like