FF F.C Looping Details

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

ENTRANCE FROM

D
2ND MID-LANDING
BE(9"X18") BE(9"X18") BE(9"X18") Legend for Switch board

SECTION - DD'
NO FALSE CEILING

-3" FRM BEAM BOTTOM LVL


1'
2'-3"
2'9"X7'0"

6" 1'-6" 6"


121" 5"
-3" FRM BEAM BOTTOM LVL GYP CEILING Main Switch board

D5
15 WL 15 WL 15 WL
5 WL
1½" X 2" thk Wooden Pelmet

GYP CEILING

1½" X 2" thk Wooden Pelmet


FROM BOTTOM LVL OF Tapered ceiling - Wooden Bed Side table Switch board

ceiling - Ply
FFL+ 7' - 6"

Tapered
B2A(9"X18")
CASSETTE AC

B5(9"X18")
B3(9"X18")
GYP CEILING -3" FRM SLAB LVL GYP CEILING Bed Side table Switch board
B1'(9"X18")

NO FALSE CEILING
Slab

10"
Glass railing

Rope light
Rope light
Rope light
Profile Light

5'-10"
BALCONY

1'-9" 1'-9" 1'-10"

+3" FRM BEAM BOTTOM LVL


3'6" X 13'3" Cut - Out

Profile Light

GYP CEILING
15 WL 15 WL

Rope light

5'-8"

Profile Light
HL

13'-3"
Landscape 3 WL 3 WL
(in Ground floor)
1'-1021" 3'-421" 1'-6"
15 WL
121" 15 WL

6'-9" 6" 1'-6" 6" 1'-10" 4'-6" 4'-6" 1'-10" 6" 1'-6" 6"

1½" X 2" thk Wooden Pelmet


5" +3" FRM BEAM BOTTOM LVL 121"

9'-6"
5"

5'-10"
15 WL 15 WL

6" 1'-6" 6" 1'-10"


GYP CEILING

20'-121"
Profile Light

Profile Light

ceiling - Ply
UP

Tapered
10"
10" 11'-2" 10"
-3" FRM SLAB LVL GYP CEILING
3'-9" 3'-9"
BD(9"X18") 7'-6" Tapered ceiling - Wooden 18'-9"

5" 121"
1½" X 2" thk Wooden Pelmet
9"

DRIVER
-4" FRM SLAB LVL

8'-5"
1'-10"
1'-7"

DRIVER 5 WL -3" FRM BEAM BOTTOM LVL GYP CEILING

B3(9"X18")
HL GYP CEILING 15 WL 15 WL 15 WL

BC1(9"X18") BC1(9"X18")

-3" FRM BEAM BOTTOM LVL


9"
B1(9"X18")

3'-2"1'-7"
1 WL
Glass railing
7'-8"

7'-4"
6'

B5(9"X18")
6'-421"
3'-6"

6'-421"
3'-2"

GYP CEILING
B2(9"X18")

AC dim 3 WL 8'-7" 1'


3' 2'-4" 2'-9" 2'-9"
CASSETTE AC

9'-721" 15' 2'-121"


3'-10"

DRIVER
10'-1021" Profile Light
ATT.TOILET 3 WL 3 WL
-6" FRM SLAB LVL
10'10½" X 7'7½"
5 WL FROM BOTTOM LVL OF 5 WL

PVC LOUVERED CEILING CASSETTE AC

3'-2"
2'-11"
1 WL wi fi
Profile Light

9" 3 WL GYP CEILING

1'-7"
4'-10" 2'-9" 8'-7" 8'-7"
2'

1'
AC dim

Drawing Title
26'-9"
9"

HL BALCONY REVISED FIRST FLOOR F.C LIGHTING


CENTERLINE & LOOPING LAYOUT
BB(9"X18") BB(9"X18") BB(9"X18") 6'0" X 34'0"

Switch Board
Drawing Number

1'-9"
9"

ATT.TOILET
Track Light 4'6" X 11'4" -12" FRM SLAB LVL 1.2

2'-3"
MASTER BED ROOM 2'-7" 2'-7" 2'-7" 2'-3" 1'-10" Drawn By
18'0" X 11'4" GYP CEILING KEERTHANA
2'

C C'
3 WL Profile Light Checked By
BEAM BOTTOM LVL DRIVER DRIVER 4'-121" 2'-2" 10' 2'-7" AR. BADREE

B5(9"X18")
10'-1121"
GYP CEILING Drawing Date

B4(9"X18")
3 WL 3 WL 3'-9" North
B2B(9"X18")

HL
Profile Light
B1(9"X18")

CEILING EXHAUST

+9" FRM BEAM BOTTOM LVL 06.05.2022

5'-6"
CHILDREN BED ROOM

-12" FRM SLAB LVL


Tapered ceiling - Gyp

Tapered ceiling - Gyp


11'-4"

Revision Date
GYP CEILING 14'9" X 11'4"

6'-6"

GYP CEILING
06.06.2022

11'
Fan dim 7' DRIVER
Revision Number
R3
Profile Light

3 WL

Profile Light
3 WL 3 WL Sheet Number
Fan dim 9' BEAM BOTTOM LVL 1 of 1

4'-6"
5'
5'-4"

BEAM BOTTOM LVL GYP CEILING Client

Fan dim
CEILING EXHAUST

GYP CEILING MR.PRADEEP KUMAR@JAIPUR


way

3'-9"

NO FALSE Duct for exhaust fan


Two

3 WL 3 WL
Project Location
CEILING
5'

00

ay
3'-2" 1'-3" 9" 6" 3'-4" 3'-4" 6" 9" 1'-3" 3'-2" Double Height Cut
ow
Tw
ow Tw 14'-9" Architects & Project Managers
9" 9"
Fan dim
2'

3 WL 3'-3" ay 3'-9" 3'-9" 4' out above


1'-9"

2'-3"
3 WL 3 WL 3 WL
18'
1'

1'
HL HL

BA(9"X21") BA(9"X21") BA(9"X21") # 4-114, 5th floor,


MN Classic,
Kokapet,
Gandipet, Hyderabad, TS -
D'

SUNKEN SLAB 500075


BEAM BOTTOM LVL +9" FRM BEAM BOTTOM LVL Developers
GYP CEILING
Tapered GYP CEILING Profile Light
Profile Light
ceiling - Gyp Tapered BEAM BOTTOM LVL
ceiling - Gyp GYP CEILING
REVISED FIRST FLOOR F.C LIGHTING SYMBOLS

SECTION - CC' CENTERLINE & LOOPING LAYOUT Elevation Section Details

06.06.2022 Drawing Code:

Concept Drawing