Specifications Application
Auxiliary Supply: 100-120, 200-240, 380-415 or The digitally controlled KPM161x series monitors insulation level between a non-grounded (IT)
440-460VAC, 40-70Hz (Fuse 0.5A) AC mains and its protective earth, regardless of whether the mains is live or non-live (standby).
Optional Voltage: 12-24, 48 or 110VDC (Fuse 2A) The unit is for land, marine, offshore, sub-sea and ocean floor use.
Supply tolerance: ± 10%
Power rating: 1,5VA
Contact rating: AC: 100VA - 250V/2A max.
An AC or DC auxiliary voltage is required for the unit, if powered from a separate source the network can
DC: 50W - 100V/1A max. also be monitored during standby conditions. Only ONE KPM161x can be connected to each IT-system.
Analogue Output: Up to 20mA, max 500R The ohmmeter and the triple-zone status LEDs give at a glance the clear safety message:
F-versions Up to 10V, min 100kohm
(other on request) - ALARM (red zone)
Temperature: -20 to +70ºC
- WARNING (yellow zone)
Weight: 0.85kgs
Front protection: IP52 (IP65 optional) - HEALTHY (green zone)
Norway
Denmark
United Kingdom Page: 1 of 4
REF: Datasheet.KPM161x - REV: 2.06/12.2018
www.megacon.com © All rights reserved to Megacon
ELECTRONIC CONTROL AND INSTRUMENTATION Megacon reserves the right to make any changes to the information at any time
INSULATION GUARD FOR NON-GROUNDED AC NETWORKS KPM161x
Description Relay Operation
KPM161E2 & KPM161F - KPM161G & KPM161GF Scale range: 0-1000kΩ - (>6MΩ)
This unit is used for hospital, industrial, marine and offshore installations.
Warning Alarm Fail Safe Latch
R1
Start of monitoring function is delayed when auxiliary power is switched on. (default 5 secs delay)
R2 *
R3 *
The unit has minimum 150 mS detection time for any insulation fault.
Model Latch Output Fail Safe Adjustments Trip level Delay
KPM161E2 - - X WARNING: 0-1MΩ 0-30secs
Direct connection up to 690V line voltage. Up to 1,4kV via HV adaptor CH163/1,4. KPM161F - X X ALARM: 0-1MΩ 0,1-3secs
KPM161G* X - X
KPM161GF* X X X
KPM161E3 & KPM161F3 - KPM161G3 & KPM161GF3 Scale range: 0-1000kΩ - (>6MΩ)
This unit is used for hospital, industrial, marine and offshore installations.
Warning Alarm Fail Safe Latch
R1
Start of monitoring function is delayed when auxiliary power is switched on. (default 5 secs delay) R2 *
R3 *
The unit has minimum 150 mS detection time for any insulation fault.
Model Latch Output Fail Safe Adjustments Trip level Delay
KPM161E3 - - X WARNING: 0-10MΩ 0-30secs
Direct connection up to 690V line voltage. Up to 1,4kV via HV adaptor CH163/1,4. KPM161F3 - X X ALARM: 0-10MΩ 0,1-3secs
KPM161G3* X - X
KPM161GF3* X X X
Norway
Denmark
United Kingdom Page: 2 of 4
Voltage Adaptors CH163x series are used for Insulation Guard KPM161x when the monitored line voltage is higher than 690VAC. These adapters
are a passive low-pass filter for use in 50, 60 or 400Hz networks, and are potted in polyurethane.
These units includes high inductance reactance modules, connected in a special configuration to avoid DC saturation. Connection to the star-point
(Neutral) is Preferable. These adapters maintain a highAC suppression of its signal output to very low, safe levels, under all conditions.
Caution
Terminal 1 must be disconnected during ’’megger’’ test.
CH163/1,4 up to 1.4kVAC
Norway
Denmark
United Kingdom Page: 3 of 4
Dimensions
9 1
10 2
11
12
13
4
DIN96
14
15
16 PANEL
17 CUTOUT
6
92 x 92mm
Mounting Bracket
19
22 20
23 21
Comport