Ss-A5 SH e Cata
Ss-A5 SH e Cata
Ss-A5 SH e Cata
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY
COMPONENTS
PRESSURE
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
WIRE-SAVING
SYSTEMS
diagnosis
MEASUREMENT
SENSORS SUNX website http://www.sunx.com Self-diagnosis Timer Light intensity Interference
monitor prevention
STATIC CONTROL
DEVICES
LASER
MARKERS
Twin adjuster enables
delicate sensitivity setting
APPLICATIONS FIBER
SENSORS
Detecting ICs in transparent sticks Detecting small bottles Sensing remaining tape LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
Tape MICRO
PHOTO-
SH-33R ELECTRIC
SENSORS
SH-22
AREA
SENSORS
SH-21 PRESSURE
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
SENSOR
Amplifiers OPTIONS
Accessory WIRE-
SAVING
Type Appearance Model No. Sensing output • MS-DIN-1 (Amplifier mounting bracket) SYSTEMS
MEASURE-
MENT
3 m 9.843 ft SENSORS
cable SS-A5 STATIC
length type CONTROL
NPN open-collector transistor DEVICES
5 m 16.404 ft LASER
cable SS-A5-C5 MARKERS
length type
Sensor heads
SH-21
Front
Thru-beam
Selection
Guide
300 mm 11.811 in Amplifier
Ultra-slim
Built-in
sensing
EX-10
reflective
EX-20
sensing
Diffuse
SH-22
Front
50 mm 1.969 in
EX-30
EX-40
1 m 3.281 ft SH-31R Red LED
EQ-30
Thru-beam
MQ-W
2 m 6.562 ft SH-33R Incorporated
RX-LS200
reflective
Red LED
detection Diffuse
RX
100 mm 3.937 in SH-32R
CY
PX-2
substrate
SH-72 –
Glass
SS-A5 / SH
Other
Products
397 Manually Sensitivity Set Photoelectric Sensor SS-A5 SERIES SH SERIES
FIBER OPTIONS
SENSORS
LASER
SENSORS
Designation Model No. Description
PHOTO-
ELECTRIC
SENSORS This is a convenient slit mask having four types of slit masks.
MICRO
PHOTO-
ELECTRIC Sensing range Min.
SENSORS Slit size Fitting sensing
SH-31R SH-31G SH-33R object
AREA
SENSORS
Slit mask 500 mm 50 mm 750 mm ø3 mm
One side
For SH-31R, 0.5 × 3 mm 19.685 in 1.969 in 29.528 in ø0.118 in
SAFETY
COMPONENTS SH-31G and OS-SS3 0.020 × 0.118 in 250 mm 25 mm 400 mm 0.5 × 3 mm
SH-33R only Both sides
9.843 in 0.984 in 15.748 in 0.020 × 0.118 in
PRESSURE
SENSORS
700 mm 70 mm 1,000 mm ø3 mm
One side
INDUCTIVE 1 × 3 mm 27.559 in 2.756 in 39.370 in ø0.118 in
PROXIMITY 0.039 × 0.118 in
SENSORS 500 mm 50 mm 750 mm 1 × 3 mm
Both sides
PARTICULAR 19.685 in 1.969 in 29.528 in 0.039 × 0.118 in
USE
SENSORS Sensor head
Mounting bracket for the ultra-small sensor head
mounting bracket MS-SS3-1 (The thru-beam type sensor head needs two brackets.) (Note 2)
SENSOR
OPTIONS (For the ultra-small type only)
PO
W
ER C
H
X-
SC
LE
VE
L
2
Sensor
checker
EX-10
EX-20
EX-30
EX-40
EQ-30
EQ-500
MQ-W
RX-LS200
RX
CY
PX-2
RT-610
Power Supply
Built-in
NX5
VF
Amplifi er-
Amplifier-
separated
separated
SU-7 / SH
SS-A5 / SH
Other
Products
Manually Sensitivity Set Photoelectric Sensor SS-A5 SERIES SH SERIES
398
Amplifier LASER
SENSORS
Stability indicator Green LED (lights up under stable light received condition or stable dark condition) LASER
MARKERS
Sensitivity adjuster Continuously variable twin adjusters
Automatic interference prevention function Incorporated (Two units of sensors can be mounted close together.)
Timer function Approx. 40 ms fixed OFF-delay timer, selectable either effective or ineffective
Environmental resistance
Ambient temperature –25 to +60 °C –13 to +140 °F (No dew condensation or icing allowed), Storage: –30 to +70 °C –22 to +158 °F
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure Selection
Guide
Vibration resistance 10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each Amplifier
Built-in
Shock resistance 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions for three times each CX-400
Material Enclosure: Heat-resistant ABS, Cover: Polyethersulfone EX-10
Cable 0.2 mm2 4-core cabtyre cable, 3 m 9.843 ft long EX-20
Cable extension Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. EX-30
Weight Net weight: 120 g approx. EX-40
Accessories MS-DIN-1 (Amplifier mounting bracket): 1pc., Adjusting screwdriver: 1 pc., Adjuster cap: 1 pc. EQ-30
Note: Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F. EQ-500
MQ-W
I/O CIRCUIT AND WIRING DIAGRAMS RX-LS200
RX
I/O circuit diagram Wiring diagram to sensor head
CY
Color code Brown lead
wire Gray cable (Beam-emitting)
D (Brown) +V PX-2
Terminal No.
ZD1 (Black) Load RT-610
Sensor circuit
Sensing output
Load Sensor head Power Supply
Tr 1 + 12 to 24 V DC
ZD2 100 mA max. Built-in
(Orange) Self-diagnosis output(Note) – ± 10 %
SS-A5 Shield NX5
Tr 2 50 mA max. (Amplifier)
(Blue) 0 V Shield
VF
Amplifi er-
Amplifier-
Internal circuit Users’ circuit separated
separated
Yellow lead
Note: The self-diagnosis output does not incorporate a short-circuit wire Black cable (Beam-receiving) SU-7 / SH
protection circuit. Do not connect it directly to a power supply or a
capacitive load. SS-A5 / SH
Other
Products
Symbols ... D: Reverse supply polarity protection diode
ZD1, ZD2: Surge absorption zener diode
Tr1, Tr2 : NPN output transistor
399 Manually Sensitivity Set Photoelectric Sensor SS-A5 SERIES SH SERIES
FIBER PRECAUTIONS FOR PROPER USE Refer to p.986~ for general precautions and p.390 for precautions of sensor head.
SENSORS
LASER
SENSORS Trimming sensor head cables
• Never use this product as a sensing device
PHOTO- for personnel protection. • Trim the ends of sensor head cables as follows.
ELECTRIC
SENSORS • In case of using sensing devices for 12 mm
MICRO
PHOTO-
personnel protection, use products which 0.472 in
ELECTRIC
SENSORS
meet laws and standards, such as OSHA, 5 mm 0.197 in
ANSI or IEC etc., for personnel protection
AREA
SENSORS applicable in each region or country. 8 mm
0.315 in
SAFETY
COMPONENTS • Always use the sensor head and the exclusive amplifier • In case of the reflective type sensor heads, with two
together as a set. parallel cables, the beam-emitting cable must be longer
PRESSURE
SENSORS than the beam-receiving cable as shown below.
INDUCTIVE
PROXIMITY
Cable extension for sensor head Beam-emitting cable (Gray)
SENSORS
PARTICULAR
• If the attached sensor head cables need to be extended, use Beam-receiving cable (Black)
USE two single core shielded cables of at least equivalent quality.
SENSORS
If a joint terminal or connector is used for extension, refer 12 mm
0.472 in
40 mm
SENSOR to the figures below. 1.575 in
OPTIONS
WIRE-
The shielded extension cable must be of ø1.45 mm Note: Do not solder the cable ends.
SAVING ø0.057 in outer diameter.
SYSTEMS
Mounting
MEASURE-
MENT Connection with joint terminal
SENSORS
Beam-emitting Beam-receiving Beam-emitting Beam-receiving
• When the amplifier is fixed with screws and nuts, the
STATIC cable cable
The beam-emitting cable cable
This
tightening torque should be 0.58 N·m or less.
CONTROL
DEVICES cable and the distance
LASER
beam-receiving cable should be
MARKERS should be separated as short as
from each other as possible.
NG OK
much as possible.
M3 (length 20 mm 0.787 in)
screw with washers
Connection with metal connector
Beam-emitting Beam-receiving Beam-emitting Beam-receiving
cable cable cable cable
The beam-emitting cable
Amplifier
and the beam-receiving mounting bracket
cable must not be connected MS-FX-1 (Optional)
to one metal connector.
Selection Use two separate metal
Guide
NG connectors. OK
Amplifier
Built-in
CX-400
EX-10
Connection to sensor head
EX-20
EX-30 1
6
EX-40 3
EQ-30 5
EQ-500 7
2
MQ-W 4
RX-LS200
RX
CY 1 Rotate the cable lock lever approx. 3 Rotate the cable lock lever approx. 6 Rotate the cable lock lever back to the
PX-2 160° clockwise. 90° counterclockwise. (The beam- “LOCK” position. (The beam-emitting
2 Insert the black beam-receiving receiving cable is hooked up.) cable is hooked up.)
RT-610
cable’s yellow inner wire into 4 Press the beam-receiving cable into 7 Press the beam-emitting cable into
Power Supply
Built-in terminal No. 4 and the outer woven the rubber retainer. the rubber retainer.
NX5 shield wire into terminal No. 3. 5 Insert the gray beam-emitting cable’s brown
inner wire into terminal No. 1 and the outer
VF
woven shield wire into terminal No. 2.
Amplifi er-
Amplifier-
separated
separated
Note: Close the case cover firmly. Not doing so will weaken the shield cable clamp.
SU-7 / SH
PRECAUTIONS FOR PROPER USE Refer to p.986~ for general precautions and p.390 for precautions of sensor head. FIBER
SENSORS
2 VF
50
3.5 1.969 Amplifi er-
Amplifier-
0.138 2-ø3.5 ø0.138 holes separated
separated
42
1.654 2-M3 × 0.5 0.020 (Burring) SU-7 / SH
14
0.551
Material: Cold rolled carbon steel (SPCC)
SS-A5 / SH
4 (Uni-chrome plated) Other
0.157 Products
Two M3 (length 20 mm 0.787 in)
screws with washers are attached.
1.2 t 1.2