Laban Complete Drawings

The document contains a table of contents listing various architectural and structural drawings for a building project including a site development plan, floor plans, sections, elevations, schedules and foundation details.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
319 views7 pages

Laban Complete Drawings

The document contains a table of contents listing various architectural and structural drawings for a building project including a site development plan, floor plans, sections, elevations, schedules and foundation details.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

NO.

TABLE OF CONTENTS PN REPUBLIC OF THE PHILIPPINES


PROVINCE OF SORSOGON

PERSPECTIVE

VICINITY MAP
A1

A1
DPWH
MUNICIPALITY OF CASTILLA
OFFICE OF THE BUILDING OFFICIALS
SITE DEVELOPMENT PLAN A1

A R C H I T E C T U R A L
GROUND FLOOR PLAN A2 BUILDING OFFICIAL

CROSS SECTION THRU A' A2 LAND USE AND ZONING

LONGITUDINAL SECTION THRU B' A2

ROOF PLAN A2

FRONT ELEVATION A3

LEFT SIDE ELEVATION A3


LINE AND GRADE
RIGHT SIDE ELEVATION A3

REAR ELEVATION A3

DOORS AND WINDOWS SCHEDULE A3

FOUNDATION PLAN S1
ARCHITECTURAL
ROOF BEAM LAYOUT S1

S T R U C T U R A L
WALL FOOTING DETAILS S1

COLUMN FOOTING DETAILS S1

COLUMN SCHEDULE S1
1 PERSPECTIVE
A1 SCALE nts STRUCTURAL
ROOF FRAMING PLAN S2

18.25m
ROOF BEAM PLAN S2
TECHNICAL DESCRIPTION 8.25m 3.75m 6.25m

LINE EARIN DISTANCE BEAM SCHEDULE S2


1-2 S84°-39'W 36.57m
2-3 S42°-55'E 56.16m
TRUSS DETAILS S2
3-4 S05°-54'W 25.18m
4-5 N88°-52'W 23.10m

E L E C T R I C A L
5-6 N18°-43'W 71.02m GROUND FLOOR LIGHTING LAYOUT E1 SANITARY
6-7 S68°-37'W 18.43m
7-8 S31°-49'W 102.81m GROUND FLOOR POWER LAYOUT E1
8-9 N56°-29'E 20.12m
9-10 S46°-59'E 24.80m
10-11 S46°-59'E 49.22m
ELECTRICAL NOTES E1

15.50m
11.00m
11-12 S00°-39'E 41.24m
N76°-01'E 18.51m ELECTRICAL LOAD COMPUTATION E1

13.00m
12-13
13-14 N03°-09'E 69.73m
14-15 N84°-57'E 12.84m THIS SITE
CIRCUIT BREAKER DIAGRAM E1
15-1 S16°-22'E 70.18m
ELECTRICAL
NATIONAL HIGHWAY ELECTRICAL SYMBOLS E1
BARANGAY ROAD

WATER LINE LAYOUT P1

2.00m

P L U M B I N G
SEWER LINE LAYOUT P1

2.50m
7.13m

5.13m
PLUMBING NOTES P1

2.63m
FIRE SAFETY
WATER LINE ISOMETRIC VIEW P1
5.00m 6.77m
11.77m
5.25m 13.00m

SEWER LINE ISOMETRIC VIEW P1

SEPTIC TANK DETAILS P1


3 VICINITY MAP 2 SITE DEVELOPMENT PLAN
A1 SCALE nts A1 SCALE 1:700 Mts.
PLUMBING SYMBOLS P1

ARCHITECT ENGINEER PROJECT TITLE & LOCATION APPROVED BY: DATE REVISION SHEET CONTENTS SHEET NO.

PERSPECTIVE

ONE - STOREY RESIDENTIAL MR. DANILO J. LABAN


VICINITY MAP A
Arch. BENJAMIN B. RIMANDO, JR., UAP SITE DEVELOPMENT PLAN

PRC NO.: 22341


VALIDITY: 06/25/2022
PTR NO.: 6903754
DATE ISSUED: 01/04/2022
PRC NO.:
VALIDITY:
PTR NO.:
DATE ISSUED:
1 3
TIN NO.: 942-893-950 PLACE: BAUANG, LA UNION TIN NO.: PLACE: LOCATION: PUROK 9 SAN ISIDRO, CASTILLA, SORSOGON OWNER CAD BY: C J F
A B C D E F G
A B C D E B F G

18.25m

16.25m
8.25m 3.75m 6.25m

3.75m 3.90m 4.10m

GUTTER
DS

W 11
5 GUTTER
11 2
1

10

1.50m
3
W GUTTER BUILDING LINE
4 W 4
5 DS
10 DN
9

1.00m
W
7

5.00m
BEDROOM 4
9 D
3
W
W
4
8
range 8

8 BEDROOM 3 W
closet 4
sink
KITCHEN D
A A
5.00m

2
W DINNING

BUILDING LINE

BUILDING LINE
island fd
6
D
T&B
7

15.50m
4 W

1.75m

GUTTER

GUTTER
D

11.00m
3
closet 2 wc

7
lav.
sho.

13.00m
ref

15.50m
2.75m
W
D 9
2
5
18.00m

D
4.00m

W BEDROOM 2 4
5 5
lav.
D
2
wc
T&B
closet

LIVING ROOM
W
4 4 DS

closet
sho.
fd

4.00m
BEDROOM 1 GUTTER
W W W
4 4 3
2.00m

3 DS

2.00m
W BUILDING LINE
4

3 1 GUTTER

2.50m
W W W
1 2 5

7.13m
GARAGE
PORCH
2

5.13m
2 4
4.50m

2.63m
1

UP
B 1
1 5.00m
11.77m
6.77m

5.25m 13.00m

1 GROUND FLOOR PLAN 2 ROOF PLAN


A 2 SCALE 1:1OO Mts. A 2 SCALE 1:1OO Mts.

1 2 3 4 6 8 10
A C E F G APEX
APEX

2.50m
2.50m

SEE TRUSS DETAIL


SEE TRUSS DETAIL
TOP BEAM LINE

0.35m
TOP BEAM LINE CEILING LINE
0.35m

CEILING LINE

3.00m
GARAGE PORCH LIVING ROOM KIT. BEDROOM 3
3.00m

KITCHEN DINING BEDROOM 3 BDRM 4 T&B

FINISH FLOOR LINE


FINISH FLOOR LINE

1.00m
1.00m

NAT. GRADE LINE


NAT. GRADE LINE

3 CROSS SECTION THRU A' 4 LONGITUDINAL SECTION THRU B'


A 2 SCALE 1:1OO Mts. A 2 SCALE 1:1OO Mts.

ARCHITECT ENGINEER PROJECT TITLE & LOCATION APPROVED BY: DATE REVISION SHEET CONTENTS SHEET NO.

GROUND FLOOR PLAN

ONE - STOREY RESIDENTIAL MR. DANILO J. LABAN


ROOF PLAN
CROSS SECTION THRU A'
A
Arch. BENJAMIN B. RIMANDO, JR., UAP LONGITUDINAL SECTION THRU B'
PRC NO.: 22341
VALIDITY: 06/25/2022
PTR NO.: 6903754
DATE ISSUED: 01/04/2022
PRC NO.:
VALIDITY:
PTR NO.:
DATE ISSUED:
2 3
TIN NO.: 942-893-950 PLACE: BAUANG, LA UNION TIN NO.: PLACE: LOCATION: PUROK 9 SAN ISIDRO, CASTILLA, SORSOGON OWNER CAD BY: C J F
1.40m 0.60m
0.70m

0.60m
0.40m

1.60m
F
F

0.9m
F

1.07m
0.70m
F

0.30
10 9 8 7 6 3

0.20m
A B C D E F G 11 5 4 2 1 FINISH FLR. LINE
W W W
1 2 3
ALUMINUM FRAMED AWNING WINDOW ALUMINUM FRAMED FIXED GLASS ALUMINUM FRAMED AWNING WINDOW
DESCRIPTION DESCRIPTION DESCRIPTION
APEX WITH FIXED GLASS WINDOW WITH FIXED GLASS

QUANTITY 1 SET QUANTITY 1 SET QUANTITY 2 SETS

LOCATION LIVING ROOM LOCATION ENTRANCE LOCATION TOILET AND BATH


2.50m

2.50m
0.60m 2.00m
0.50m

TOP OF BEAM 2.40m

0.50m
0.35m

0.35m
F F F F 0.60m
6.85m

6.85m

0.90m
CEILING LINE

1.50m

0.70m
1.80m
F F

1.00m
3.00m

3.00m
F

1.40m
FINISH FLOOR LINE

1.00m
0.70m
1.00m

1.00m
NATURAL GRADE LINE
FINISH FLR. LINE
W W W
4 5 6
ALUMINUM FRAMED SLIDING WINDOW ALUMINUM FRAMED SLIDING WINDOW ALUMINUM FRAMED SLIDING WINDOW
DESCRIPTION DESCRIPTION DESCRIPTION WITH FIXED GLASS
WITH FIXED GLASS WITH FIXED GLASS

QUANTITY 7 SETS QUANTITY 4 SETS QUANTITY 1 SET

LOCATION BEDROOM LOCATION BEDROOM LOCATION KITCHEN

2.80m 2.40m

1 FRONT ELEVATION 2 LEFT SIDE ELEVATION 1.20m


0.70m 0.60m

A 3 SCALE 1:1OO Mts. A 3 SCALE 1:1OO Mts.

0.70m
0.6m

0.70m

1.80m
F F

1.80m
1.40m

0.70m
1 2 3 4 5 6 7 8 9 10 11 G F E D C B A FINISH FLR. LINE
W W W
7 8 9
ALUMINUM FRAMED SLIDING WINDOW
DESCRIPTION ALUMINUM FRAMED SLIDING WINDOW DESCRIPTION DESCRIPTION ALUMINUM FRAMED AWNING WINDOW
WITH FIXED GLASS

APEX QUANTITY 1 SET QUANTITY 1 SET QUANTITY 1 SET

LOCATION KITCHEN LOCATION DINING LOCATION HALLWAY


2.50m

2.50m
1.00m 0.90 0.80m 0.70m

TOP OF BEAM
0.35m

0.35m
6.85m

6.85m
CEILING LINE
3.00m

3.00m

2.10m

2.10m

2.10m

2.10m
FINISH FLOOR LINE
1.00m

1.00m
NATURAL GRADE LINE
FINISH FLR. LINE
D D D D
1 2 3 4
DESCRIPTION SOLID WOOD PANEL DOOR DESCRIPTION SOLID WOOD PANEL DOOR DESCRIPTION SOLID WOOD PANEL DOOR DESCRIPTION SOLID WOOD PANEL DOOR

QUANTITY 1 SET QUANTITY 4 SETS QUANTITY 1 SETS QUANTITY 2 SETS

LOCATION MAIN DOOR LOCATION BEDROOM LOCATION KITCHEN LOCATION T&B

3 RIGHT SIDE ELEVATION 4 REAR ELEVATION 5 DOORS AND WINDOWS SCHEDULE


A 3 SCALE 1:1OO Mts. A 3 SCALE 1:1OO Mts. A 3 SCALE 1:1OO Mts.

ARCHITECT ENGINEER PROJECT TITLE & LOCATION APPROVED BY: DATE REVISION SHEET CONTENTS SHEET NO.

FRONT ELEVATION

ONE - STOREY RESIDENTIAL MR. DANILO J. LABAN


LEFT SIDE ELEVATION
RIGHT SIDE ELEVATION
A
Arch. BENJAMIN B. RIMANDO, JR., UAP REAR ELEVATION
PRC NO.: 22341
VALIDITY: 06/25/2022
PTR NO.: 6903754
DATE ISSUED: 01/04/2022
PRC NO.:
VALIDITY:
PTR NO.:
DATE ISSUED:
DOORS AND WINDOWS SCHEDULE 3 3
TIN NO.: 942-893-950 PLACE: BAUANG, LA UNION TIN NO.: PLACE: LOCATION: PUROK 9 SAN ISIDRO, CASTILLA, SORSOGON OWNER CAD BY: C J F
A B C D E F G A B C D E F G

16.25m 16.25m

3.75m 4.50m 3.90m 4.10m 3.75m 4.50m 3.90m 4.10m

TB01
RB-02

11 SLAB ON FILL
10mm Ø @ 600 mm
WF01
11
1.50m

1.50m
BOTHWAYS
C1F1 C1F1
4'' THICK CHB WITH 10 mm Ø
TB01
RB-02 VERTICAL REBARS @ 600 mm.,
10 10 &10 mm., Ø HORIZONTAL REBARS
1.00m

1.00m
C1F1 WF01
TB01 C1F1 C1F1 SPACED @ EVERY 3 LAYERS

RB-02
5.00m

5.00m
RB-02
RB-02
9 9 OF CHB.

WF01

TB01
WF01
WF01
C1F1 TB01
RB-02

8 SLAB-ON-FILL

RB-02
WF01

TB01
C1F1 C1F1
TB01

WF01
5.00m

5.00m

RB-02
WF01
TB01

RB-02 RB-02

TB01
WF01 WF01

RB-02

RB-02
RB-02
TB01

WF01

1.75m

1.75m
TB01 TB01
7 7 RB-02 RB-02
3-12 mm Ø LONGITUDINAL

RB-02
TB01 C1F1
WF01
C1F1 C1F1
BOTTOM BARS

6 6

15.50m

15.50m
RB-02 RB-02 RB-02

RB-02
TB01

2.75m

2.75m
WF01

TB01
WF01

1.00
C1F1 C1F1

WF01
18.00m

18.00m

RB-02
RB-02
RB-02
TB01
12 mm Ø TRAVERSE
4.00m

4.00m
RB-02
WF01
TB01

5 WF01
5 BOTTOM BARS SPACED
WF01

RB-02
WF01
C1F1 C1F1 @ 300mm M.O.C.

0.20
WF01

RB-02

RB-02
WF01
4 4
RB-02

4.00m

4.00m
TB01
WF01
RB-02
TB01
C1F1 C1F1 C1F1
2.00m

2.00m
0.45
100 mm THK GRAVEL BED,
WF01
95 % COMPACTION
WF01
RB-02 RB-02
3 TB01 TB01
3
C2F2 C1F1 C1F1 C1F1

RB-01

RB-01

RB-01
2.00m

2.00m
WF01
WF01 SECTION
TB01

2 2
TB01
4.50m

4.50m
TB01 RB-01
C2F2

1 TB01
1 RB-01
C2F2 C2F2

1 FOUNDATION PLAN 2 ROOF BEAM LAYOUT 3 WALL FOOTING DETAILS


S 1 SCALE 1:1OO Mts. S 1 SCALE 1:1OO Mts. S 1 SCALE 1:1OO Mts.

10mm Ø LATERAL
10mm Ø LATERAL
TIES @ 5 - 50mm,
TIES @ 5 - 50mm,
@5 - 100mm, 0.25
@5 - 100mm, 0.20
REST @ 150mm
1.00m REST @ 150mm

0.25m

GRADE LINE GRADE LINE


4-16mm.∅

0.25

0.20
6-16mm ∅

5-12mm. ∅ 0.20m
4-12mm. ∅
BOTHWAYS BOTHWAYS

VERIFY
VERIFY

C-01 C-02
0.25m
1.00m

MAIN BAR: MAIN BAR:


0.80 m

0.20m

5 - 12mm Ø 4 - 12mm Ø 6-16mm ∅ 4-16mm ∅


BOTHWAYS BOTHWAYS TIES: TIES:
10mm ∅ 10mm ∅
6-16mm. ∅ 5 @ 50mm, 5 @ 50mm,
5 @ 100mm, 5 @ 100mm,
MAIN BAR 4-16mm. ∅

0.20m
0.20m

rest @ 150mm to CENTER rest @ 150mm to CENTER


MAIN BAR
PLAN PLAN
C1F1 SECTION
1.00m
C2F2 SECTION
0.80m

4 COLUMN FOOTING DETAILS 5 COLUMN SCHEDULE


S 1 SCALE 1:1OO Mts. S 1 SCALE 1:1OO Mts.

ARCHITECT CIVIL ENGINEER PROJECT TITLE & LOCATION APPROVED BY: DATE REVISION SHEET CONTENTS SHEET NO.

FOUNDATION PLAN

ONE - STOREY RESIDENTIAL MR. DANILO J. LABAN


ROOF BEAM LAYOUT
WALL FOOTING DETAILS
S
Arch. BENJAMIN B. RIMANDO, JR., UAP COLUMN FOOTING DETAILS
PRC NO.: 22341
VALIDITY: 06/25/2022
PTR NO.: 6903754
DATE ISSUED: 01/04/2022
PRC NO.:
VALIDITY:
PTR NO.:
DATE ISSUED:
COLUMN SCHEDULE 1 2
TIN NO.: 942-893-950 PLACE: BAUANG, LA UNION TIN NO.: PLACE: LOCATION: PUROK 9 SAN ISIDRO, CASTILLA, SORSOGON OWNER CAD BY: C J F
0.20m 0.20m

18.25m
2-16mm ∅ 2-16mm ∅

8.25m 3.75m 6.25m

0.30m

0.30m
5-10mm ∅ spaced @ 50mm
2-16mm ∅ 2-16mm ∅

TRUSS 13
L/4 E.S M.S
rest spaced @ 150mm
RB-01

TOP BAR : 2-16mm ∅

6
TR
TRUSS 14

S
US
BOTTOM BAR : 2-16mm ∅

US
TR

TR
TRUSS 9
US

6
S
5-10mm ∅ spaced @ 100mm

3
6
L/3

U SS
TR
TRUSS 15
L
TRUSS 14
SECTION

TR

TRUSS 10

TRUSS 7
US
0.20m 0.20m

S
4
TRUSS 11

15.50m
TRUSS 1

TRUSS 1
2-16mm ∅
RB-01 4-16mm ∅
11.00m

TRUSS 2

0.35m

0.35m
13.00m

TRUSS 8
S

2-16mm ∅ 4-16mm ∅
US
TR

E.S M.S
TRUSS 14

4
S
TR
US
RB-02
TRUSS 11

TR
TRUSS 14

US
US

S
TR
TOP BAR : 4-16mm ∅ TOP BAR : 2-16mm ∅

3
BOTTOM BAR : 2-16mm ∅ BOTTOM BAR : 4-16mm ∅

TRUSS 15
5-10mm ∅ spaced @ 50mm
TRUSS 16
TRUSS 11

TRUSS 11
TRUSS 5

TRUSS 8

TRUSS 5
L/4
rest spaced @ 150mm
2.00m

2.50m
0.20m 0.20m
7.13m

3-16mm ∅ 2-16mm ∅

5.13m

0.30m

0.30m
2.63m
L/3 5-10mm ∅ spaced @ 100mm
2-16mm ∅ 3-16mm ∅

L
E.S M.S

SECTION
5.00m 6.77m TB-01
11.77m

5.25m 13.00m

RB-02 TOP BAR : 3-16mm ∅ TOP BAR : 2-16mm ∅


BOTTOM BAR : 2-16mm ∅ BOTTOM BAR : 3-16mm ∅

1 ROOF FRAMING PLAN 2 ROOF BEAM DETAILS 3 BEAM SCHEDULE


S 2 SCALE 1:1OO Mts. S 2 SCALE NTS S 2 SCALE 1:50 Mts.

5.9 5.8 9.36 8.08 7.7


1m 8m m m 8m
2.50m 7.34

2.50m
m
2.16m

2.16m
2.10m

1.96m
1.20m 1.20m 1.20m 1.20m 1.20m 1.20m 1.90m 1.35m 1.35m 1.35m 1.20m 1.20m 1.20m 1.90m 1.20m 1.20m 1.20m 1.20m 1.20m 1.20m 1.82m 1.20m 1.20m 1.20m 1.20m 1.20m 1.78m 1.20m 1.20m 1.20m 1.20m 2.27m
1.90m 1.35m 1.20m 1.20m 1.20m 1.20m 1.20m 1.37m
11.00m 10.90m 9.02m 7.78m 7.37m 7.07m

TRUSS 1 TRUSS 2 TRUSS 3 TRUSS 4 TRUSS 5 TRUSS 6

6.8
7.12 5m 5.6
m 0m 5.6 4.7
2.50m

8 m 0m
2.25m

2.16m
1.96m

4.59 3.13 3.7

1.72m
m 6m
m

1.37m
1.23m

1.14m
1.20m 1.20m 1.20m 1.20m 1.58m 1.20m 1.20m 2.02m
1.20m 1.20m 1.20m 1.20m 1.95m 1.00m 1.20m 1.20m 1.20m 1.65m 1.20m 1.20m 1.20m 1.65m 1.20m 1.20m 1.20m 0.78m 1.59m 1.20m 1.71m
1.20m 1.20m 1.10m
6.75m 6.38m 6.25m 5.25m 4.38m 4.42m 3.50m
4.50m

TRUSS 7 TRUSS 8 TRUSS 9 TRUSS 10 TRUSS 11 TRUSS 12 TRUSS 13 TRUSS 14


2.5
5m 2.15
0.93m

0.78m
1.20m 1.18m 1.20m 0.80m
2.38m 2.00m

TRUSS 15 TRUSS 16

4 TRUSS DETAILS
S 2 SCALE 1:100 Mts.

ARCHITECT CIVIL ENGINEER PROJECT TITLE & LOCATION APPROVED BY: DATE REVISION SHEET CONTENTS SHEET NO.

ROOF FRAMING PLAN

ONE - STOREY RESIDENTIAL MR. DANILO J. LABAN


ROOF BEAM DETAILS
BEAM SCHEDULE
S
Arch. BENJAMIN B. RIMANDO, JR., UAP TRUSS DETAILS
PRC NO.: 22341
VALIDITY: 06/25/2022
PTR NO.: 6903754
DATE ISSUED: 01/04/2022
PRC NO.:
VALIDITY:
PTR NO.:
DATE ISSUED:
2 2
TIN NO.: 942-893-950 PLACE: BAUANG, LA UNION TIN NO.: PLACE: LOCATION: PUROK 9 SAN ISIDRO, CASTILLA, SORSOGON OWNER CAD BY: C J F
c c IN GENERAL:
1 1

PLANTERS
ROOF LINE
PLANTERS ACU
- All Electrical works shall be done in accordance with the latest edition of the Philippine Electrical
2 2

3 b b 3 CKT
Code (PEC), the rules and regulations of the Local Enforcing Authority, the National Building Code,
and the requirements of the Local Power Company or Utility
10
4 4

a
DN DN
ACU
- Other Codes, standards governing the specific designs shall served as a guide or basis on the
b b
WP CKT
actual implementation and execution of Electrical works
BEDROOM 4 9 BEDROOM 4
Sa a
RANGE - All Electrical works shall be under the direct supervision of either of the following with valid license:
b range b range
CKT Professional Electrical Engineer
12
Registered Electrical Engineer
BEDROOM 3 BEDROOM 3
Registered Master Electrician
a b
closet closet
sink sink
b
CKT
- Electrical Supply shall be as required for specific use whether:
ROOF LINE

ROOF LINE
2 Sab

KITCHEN island DINNING fd KITCHEN island DINNING fd 220 V Single Phase 2 - Wire 60 Hz system
a Sab Sa
a 110 / 220 V Single Phase 3 - Wire 60 Hz system
T&B T&B
a a
b Sa
b
closet
lav.
wc closet
lav.
wc
- All wires and cables to be used shall be copper, insulation required will depend on its specific use to wit:
sho. sho.
Lightings - THHN Type
Sa

CKT CKT

b b
6 11 Convenience outlets - THHN Type
ref ref

Sab REF
Power (ACU's, Motors, Heaters, etc)- THHN Type
Service Entrance - THHN Type
b b PLANTERS PLANTERS Service Lateral - THHN Type
a
c
Service Service Drop - THW Type
Sabc b b CKT

Sa
MPB 4 MPB
- The minimum size of wire and conduit to be used shall be:
BEDROOM 2 BEDROOM 2
a
lav. lav. Lightings - 2.0 mm2, 15 mm dia. Pipe
CKT Sabc
1
b
ACU
C.O. - 3.5 mm2, 15 mm dia. Pipe
wc a b wc
T&B T&B
closet

closet
CKT
CKT
7
8
- Type of wiring shall be in rigid PVC pipe in concrete slab and floor as required.

closet

closet
LIVING ROOM LIVING ROOM

b b
sho.
fd
a ACU
sho.
fd
- Panel boards shall be located on load center to minimize length of home runs
a
BEDROOM 1 BEDROOM 1 - All circuit breakers shall be Inverse Time Type, and of required Interrupting Capacity Rating as designed,and
b
of Residential Type Category
- Grounding system shall be implemented as required. All metal parts of all equipment shall be bonded and
c
grounded in accordance with Article 2.50 of the PEC. Ground resistance shall be tested and should passed
CKT
WP 5

the ohmic value for safety of life and property


b b
a
Sabc Sab
Sabc
b b
- Prior to energizaion, and to ensure the integrity ( Free from shorts and grounds) of the installations,insulation
b
c c
Sabc
CKT
WP
resistance testing shall be conducted on the following:
b b 3
Branch circuits
PORCH
c
PORCH Sub-feeders
a
Breakers
GARAGE GARAGE
b b
Bus bars Service
4 4 Entrance / Service Lateral
3 3

2 PLANTERS 2 PLANTERS
Motor loads in general, if any
a
1 1

Note: Results shall passed the required insulation value in MEGA OHMS
UP UP - Installation of Standby Generator shall be accompanied with Transfer Switches to supply power in case of
blackouts is optional.If in case, its rating in kVA shall be based on the emergency power requirement of the
ROOF LINE
b b installations or as required. Shifting of power shall be done manually or automatic or as required.
- Scheduled (post) electrical inspection and testing is highly recommended.
- Breakers shall be bolt-on Type

1 GROUND FLOOR LIGHTING LAYOUT 2 GROUND FLOOR POWER LAYOUT 3 ELECTRICAL NOTES
E1 SCALE 1:1OO Mts. E1 SCALE 1:1OO Mts. E 1

POWER SERVICE ENTRANCE CAP


SCHEDULE OF LOAD
220 V, 60 Hz M MAIN KILOWATT-HOUR METER
No. of FREQ. OCP CONDUCTOR SERVICE ENTRY 2 - #35mm THHN COPPER 2
CKT. No. LOAD DESCRIPTION VA VOLT PHASE FLA CONDUIT SIZE POWER AND LIGHTING PANEL BOARD
OUTLET Hz D SIZE 2-WIRE ENTRY WIRE IN 21 '' Ø PIPE
M
1 LIGHTINGS 15 1,500 220 1 60 6.82 15 AT 2 - 3.5 mm² THHN 1/2" Ø PVC
2 LIGHTINGS 15 1,500 220 1 60 6.82 15 AT 2 - 3.5 mm² THHN 1/2" Ø PVC CKT1
BRANCH CIRCUIT HOMERUN TO PANELBOARD
3 LIGHTINGS 15 1,500 220 1 60 6.82 15 AT 2 - 3.5 mm² THHN 1/2" Ø PVC
4 LIGHTINGS 11 1,100 220 1 60 5.00 15 AT 2 - 3.5 mm² THHN 1/2" Ø PVC PANEL REF REFRIGERATOR OUTLET
5 CONVENIENCE OUTLET 9 1,620 220 1 60 7.36 20 AT 2 - 3.5 mm² THHN 1/2" Ø PVC BOARD 01
6 CONVENIENCE OUTLET 10 1,800 220 1 60 8.18 20 AT 2 - 3.5 mm² THHN 1/2" Ø PVC ACU AIR CONDITIONING UNIT OUTLET
7 REF OUTLET 1 250 220 1 60 1.14 20 AT 2 - 3.5 mm² THHN 1/2" Ø PVC
8 ELECTRIC RANGE 1 6,400 220 1 60 29.09 30 AT 2 - 5.5 mm² THHN 1/2" Ø PVC MAIN 120 AT/ 300 AF
WP WEATHER PROOF OUTLET
9 1.5 HP ACU 1 2,300 220 1 60 10.00 30 AT 2 - 5.5 mm² THHN 1/2" Ø PVC
10 1.5 HP ACU 1 2,300 220 1 60 10.00 30 AT 2 - 5.5 mm² THHN 1/2" Ø PVC L.O. L.O.
1 2 RANGE OUTLET
RANGE
11 1.5 HP ACU 1 2,300 220 1 60 10.00 30 AT 2 - 5.5 mm² THHN 1/2" Ø PVC
12 1.5 HP ACU 1 2,300 220 1 60 10.00 30 AT 2 - 5.5 mm² THHN 1/2" Ø PVC
3 L.O. L.O.
13 ELECTRIC WATER PUMP 1 1,840 220 1 60 8.36 20 AT 2 - 5.5 mm² THHN 1/2" Ø PVC
4 CENTER LIGHT
14 SPARE 1 0 220 1 60 0 20 AT 2 - 3.5 mm² THHN 1/2" Ø PVC
5 C.O. C.O
6 PIN LIGHT
26,710 121.409091
REF RANGE
TOTAL FULL LOAD CURRENT : 97.12 Amps. 7 8 PENDANT LIGHT
MAIN CONDUCTOR USED :
MAIN CIRCUIT BREAKER USED: AT 9 ACU ACU
10 Sabc THREE GANG SWITCH PLATE
MAIN CONDUIT SIZE USED:
ACU ACU TWO GANG SWITCH PLATE
11 12 Sab

IFL=26,710/220V PUMP SPARE Sa ONE GANG SWITCH PLATE


13 14
=121.40 AT
CIRCUIT LINE FOR LIGHTING
80% DEMAND FACTOR
CIRCUIT LINE FOR CONVENIENCE OUTLET
= 121.40 x 0.80
= 97.12 Amps SWITCH RUN

4 ELECTRICAL LOAD COMPUTATION 5 CIRCUIT BREAKER DIAGRAM 6 ELECTRICAL SYMBOLS


E 1 SCALE 1:1OO Mts. E 1 SCALE 1:1OO Mts. E 1 SCALE 1:1OO Mts.

ARCHITECT PROFESSIONAL ELECTRICAL ENGINEER PROJECT TITLE & LOCATION APPROVED BY: DATE REVISION SHEET CONTENTS SHEET NO.

GROUND LIGHTING LAYOUT

ONE - STOREY RESIDENTIAL MR. DANILO J. LABAN


GROUND FLOOR POWER LAYOUT
ELECTRICAL NOTES
E
Arch. BENJAMIN B. RIMANDO, JR., UAP ELECTRICAL LOAD COMPUTATION
PRC NO.: 22341
VALIDITY: 06/25/2022
PTR NO.: 6903754
DATE ISSUED: 01/04/2022
PRC NO.:
VALIDITY:
PTR NO.:
DATE ISSUED:
CIRCUIT BREAKER DIAGRAM
ELECTRICAL SYMBOLS
1 1
TIN NO.: 942-893-950 PLACE: BAUANG, LA UNION TIN NO.: PLACE: LOCATION: PUROK 9 SAN ISIDRO, CASTILLA, SORSOGON OWNER CAD BY: C J F
1. ALL PLUMBING WORKS INCLUDED HEREIN SHALL BE EXECUTED IN ACCORDANCE TO THE REQUIREMENTS OF THE PHILIPPINE PLUMBING
CODE.
TO DRAINAGE CANAL
2. THE SPECIFICATIONS AND DRAWINGS ARE MUTUALLY COMPLEMENTARY WHAT IS NOTED IN ONE ALTHOUGH NOT SHOWN IN THE OTHER
SHALL BE
SEPTIC TANK SEPTIC TANK DS
CB
CONSIDERED CONTAIN IN ALL CASE OF CONFLICT, THE SPECIFICATION SHALL PREVAIL OVER THE DRAWINGS.
1 1

2 PLANTERS 2 PLANTERS
3 3 3. THE DRAWINGS SHOW THE GENERAL ARRANGEMENT OF ALL THE PIPINGS, HOWEVER, WHERE LOCAL OR ACTUAL CONDITIONS AT THE JOB
4 4
CO SITE
NECESSITATE A DEVIATION OR ARRANGEMENT FOR THE ENGINEER/ARCHITECTS APPROVAL..
DN DN

4. THE PLUMBING SYSTEM SHALL BE LAID OUT AND INSTALLED CONSISTENTLY THROUGHOUT WITH THE GIVEN SLOPES IN THE PLANS AND
BEDROOM 4 BEDROOM 4
CB
DS
SHALL CONFORM
TO THE ACTUAL LOCATION DEPTH AND INVERT ELEVATION OF EXISTING PIPES.
range 1/2 Ø PPR PIPE range

5. ALL ABOVE GROUND STORM DRAIN AND UNDER GROUND PASSING UNDER SLAB SHALL BE POLYVINYL CHLORIDE (PVC).
BEDROOM 3 BEDROOM 3
sink
closet
sink
closet
6. ALL SANITARY SEWER LINES SHALL BE POLYVINYL CHLORIDE (PVC) PIPES AND FITTINGS SCH. 40. THE SLOPE FOR HORIZONTAL SEWER
LINES SHALL
KITCHEN island DINNING KITCHEN island DINNING
fd fd
BE IN 1% FOR Ø100 mm PIPES AND ABOVE AND 2% FOR Ø75 mm AND BELOW.
T&B T&B
closet closet
7. ALL VENT PIPING SHALL BE POLYVINYL CHLORIDE (PVC) SCH. 40 AS APPROVED AS BY THE ENGINEER/ARCHITECT. ALL PLUMBING
wc wc
lav.
sho.
lav.
sho.
FIXTURES SHALL
1/2 Ø PPR PIPE

BE INDIVIDUALLY VENTED UNLESS OTHERWISE INDICATED THE VENT BRANCH OF THE SEWER LINES SHALL BE TAKEN AT A VERTICAL
1/2 Ø PPR PIPE
ref ref ANGLE OR FROM THE TOP OF THE HORIZONTAL.

8. ALL PLUMBING WORKS SHALL BE DONE UNDER THE DIRECT SUPERVISION OF A SANITARY ENGINEER OR A MASTER PLUMBER.
PLANTERS PLANTERS
9. ALL CHANGES IN DIRECTION SHALL BE MADE IN APPROPRIATE USE OF 45° WYE LONG SWEEP QUARTER BEND.

BEDROOM 2 BEDROOM 2
10. ALL CHANGES IN DIRECTION SHALL BE MADE IN APPROPRIATE USE OF 45° WYES, LONG SWEEP QUARTER BENDS, HALF WYES EXCEPT
lav. lav.
THAT SINGLE
wc wc
SANITARY TEES MAY BE TO OTHER USED ON VERTICAL ATTACKS, AND SHORT QUARTER BENDS MAY BE USED IN SOIL AND WASTE LINES
T&B T&B
closet

closet
WHERE THE
LIVING ROOM LIVING ROOM

closet

closet
CHANGE IN THE DIRECTION OF FLOW IS FROM THE HORIZONTAL TO THE VERTICAL. TEES AND CROSSES MAY BE USED IN VENT PIPES.
sho. sho.
fd fd
DS
GVWMCV GV
M
BEDROOM 1 CB BEDROOM 1 11. NO DOUBLE HUB, DOUBLE T BRANCH SHALL BE USED ON HORIZONTAL SOIL OR WASTE LINE, THE DRILLING AND TAPPING OF HOUSE DRAIN,
1/2 Ø PPR PIPE
FROM WATER
SOURCE
SOIL WASTE
OR VENT PIPES AND THE USE OF SADDLE HUBS AND BEND ARE PROHIBITED.

12. DEAD ENDS SHALL BE AVOIDED ON ALL DRAINAGE SYSTEM INSTALLATION.


DS
CB
13. THERE SHALL BE A CLEAN OUT WITHIN FIVE (5) FEET INSIDE THE PROPERTY LINE BEFORE THE HOUSE SEWER CONNECTION, CONNECTED
FROM A FULL
PORCH PORCH SIZED BRANCH, EXCEPT FOR THE LATTER, CLEAN-OUTS SHALL BE OF THE SAME NOMINAL SIZE AST THE PIPES. THE DISTANCE BETWEEN
GARAGE GARAGE
CLEN-OUT IN
HORIZONTAL WASTE OR SOIL LINES SHALL NOT EXCEED BY FIFTY (50) FEET.
4 4
3 3

2 PLANTERS 2 PLANTERS 14. VERIFY AND DETERMINE, SUBJECT TO THE ENGINEER/ARCHITECT'S APPROVAL THE BEST LOCATION AT WHICH TO CONNECT THE
1 1 DRAINAGE SYSTEM
TO EXISTING STREET DRAIN OR TO OTHER CONVENIENT ACCEPTABLE APPROVED WATER DISCHARGE RECEIVER IN ALL CASES, PROVIDE
UP UP STORM
DRAINAGE LINES WITH 2% MINIMUM SLOPE TOWARDS DIRECTIONS OF DRAIN.

1 WATER LINE LAYOUT 2 SEWER LINE LAYOUT 3 PLUMBING NOTES


P 1 SCALE 1:1OO Mts. P 1 SCALE 1:1OO Mts. P 1

2.50m PWL POTABLE WATER LINE


1.00m 0.75m 0.75m

SP/DP SOIL PIPE/DRAIN PIPE


DS CB 1OOmm Ø PVC TEE
W/ CLEAN-OUT

LAV LAVATORY

1.00m
4 MANHOLE MANHOLE MANHOLE
M
OO
DR
BE clo
set 4
fd
OM
RO
B sh
o. BE
D
clo
set
fd
1OOmm Ø PVC
INLET PIPE
1OOmm Ø
PVC TEE 1OOmm Ø PVC
OUTLET PIPE
WC WATER CLOSET
T& wc

lav
.
B o.
sh
RS T&
TE wc PLAN
NK 3 AN

SE
PT
IC
TA
ED
R OO
M PL lav
.

TE
R S FD FLOOR DRAIN
B E K 3 AN
PIP TA
N
OM PL
PR IC CO RO 1OOmm Ø thick Concrete 1OOmm x 5OOmm x 5OOmm 15Omm CHB WALL w/ 12mm Ø

ØP PT D Slab w/ 12mm reinforcement Concrete Manhole w/ 3-1Omm Vertical Bars S.P @ 6OOmm

1/2 SE BE bars S.P. @ 125mm O.C. BW Bars B.W. & Bar Handel O.C & 12mm Ø Horizontal BarS
S.P @ every 3 layer of CHB
CO CO CO CO
t
se GV
GV GATE VALVE
E
PIP clo
RS PP
R 1
TE Ø OO
M
AN 1/2 R et
3OOmm Air Space

PL G BE
D
S clo
s
CB
1OOmm Ø PVC
AL 1 DS
1 IN ER M
INLET PIPE

NN clo
AN NT O
DI RO
2 se
t C A
PL
3
D
4
GE NG BE
INA CV
CV
DN
DR
A
1
2
3 DI
NN
I clo
set
1OOmm Ø
PVC Tee CHECK VALVE
4
ge TO
ran
DN
d
isl
an
OM ge
EN ran DIGESTIVE

2.00m
RO LEACHING LEACHING
sin
k
KIT
CH
LIV
IN
G
DS
CB an
d
M CHAMBER WELL 1 WELL 2
M M WATER METER
isl
ref EN OO
RS
H GR
H ITC
.
lav B RC k IN
T& TE sin K LIV
wc fd PO AN ref
2 PL S
E . H
o. B ER
M lav
RC
FAU FAUCET
PIP clo sh
R
PP R OO se
t T& PO NT
wc A
ED fd 16mm thick
PL
Ø 4
1/2 B 3 CONCRETE
2 2 o.
PLASTERING
1 OM clo sh
RO
se
t
D 4
E BE 3
2 CO
PIP
CO
1
CLEANOUT

0.20m
PR UP
ØP
1/2
E
AG
G AR UP
GRAVEL FILL

GE

CV
GV
DS
CB
GA
RA 0.40m CB CB CATCH BASIN
WM
GV M

TE
WA CE
OM UR
R
SECTION DS DOWNSPOUT
FR SO

4 WATER LINE ISOMETRIC VIEW 5 SEWER LINE ISOMETRIC VIEW 6 SEPTIC TANK DETAILS 7 PLUMBING NOTES
P 1 SCALE 1:1OO Mts. P 1 SCALE 1:1OO Mts. P 1 SCALE 1:1OO Mts. P 1 SCALE 1:1OO Mts.

ARCHITECT MASTER PLUMBER PROJECT TITLE & LOCATION APPROVED BY: DATE REVISION SHEET CONTENTS SHEET NO.
WATER LINE LAYOUT

ONE - STOREY RESIDENTIAL MR. DANILO J. LABAN


SEWER LINE LAYOUT
PLUMBING NOTES P
Arch. BENJAMIN B. RIMANDO, JR., UAP BENJAMIN B. RIMANDO, JR., RMP WATER LINE ISOMETRIC VIEW
PRC NO.: 22341
VALIDITY: 06/25/2022
PTR NO.: 6903754
DATE ISSUED: 01/04/2022
PRC NO.: 5258
VALIDITY: 06/25/22
PTR NO.: 6903755
DATE ISSUED: 01/04/2022
SEWER LINE ISOMETRIC VIEW
SEPTIC TANK DETAILS 1 1
PLACE: Bauang, La Union PLACE: Bauang, La Union LOCATION: PUROK 9 SAN ISIDRO, CASTILLA, SORSOGON OWNER CAD BY: C J F PLUMBING SYMBOLS