Water Line Layout Sewer Line Layout Plumbing Notes: One - Storey Residential
Water Line Layout Sewer Line Layout Plumbing Notes: One - Storey Residential
Water Line Layout Sewer Line Layout Plumbing Notes: One - Storey Residential
ALL PLUMBING WORKS INCLUDED HEREIN SHALL BE EXECUTED IN ACCORDANCE TO THE REQUIREMENTS OF THE PHILIPPINE PLUMBING
CODE.
TO DRAINAGE CANAL
2. THE SPECIFICATIONS AND DRAWINGS ARE MUTUALLY COMPLEMENTARY WHAT IS NOTED IN ONE ALTHOUGH NOT SHOWN IN THE OTHER
SHALL BE
SEPTIC TANK SEPTIC TANK DS
CB
CONSIDERED CONTAIN IN ALL CASE OF CONFLICT, THE SPECIFICATION SHALL PREVAIL OVER THE DRAWINGS.
1 1
2 PLANTERS 2 PLANTERS
3 3 3. THE DRAWINGS SHOW THE GENERAL ARRANGEMENT OF ALL THE PIPINGS, HOWEVER, WHERE LOCAL OR ACTUAL CONDITIONS AT THE JOB
4 4
CO SITE
NECESSITATE A DEVIATION OR ARRANGEMENT FOR THE ENGINEER/ARCHITECTS APPROVAL..
DN DN
4. THE PLUMBING SYSTEM SHALL BE LAID OUT AND INSTALLED CONSISTENTLY THROUGHOUT WITH THE GIVEN SLOPES IN THE PLANS AND
BEDROOM 4 BEDROOM 4
CB
DS
SHALL CONFORM
TO THE ACTUAL LOCATION DEPTH AND INVERT ELEVATION OF EXISTING PIPES.
range 1/2 Ø PPR PIPE range
5. ALL ABOVE GROUND STORM DRAIN AND UNDER GROUND PASSING UNDER SLAB SHALL BE POLYVINYL CHLORIDE (PVC).
BEDROOM 3 BEDROOM 3
sink
closet
sink
closet
6. ALL SANITARY SEWER LINES SHALL BE POLYVINYL CHLORIDE (PVC) PIPES AND FITTINGS SCH. 40. THE SLOPE FOR HORIZONTAL SEWER
LINES SHALL
KITCHEN island DINNING KITCHEN island DINNING
fd fd
BE IN 1% FOR Ø100 mm PIPES AND ABOVE AND 2% FOR Ø75 mm AND BELOW.
T&B T&B
closet closet
7. ALL VENT PIPING SHALL BE POLYVINYL CHLORIDE (PVC) SCH. 40 AS APPROVED AS BY THE ENGINEER/ARCHITECT. ALL PLUMBING
wc wc
lav.
sho.
lav.
sho.
FIXTURES SHALL
1/2 Ø PPR PIPE
BE INDIVIDUALLY VENTED UNLESS OTHERWISE INDICATED THE VENT BRANCH OF THE SEWER LINES SHALL BE TAKEN AT A VERTICAL
1/2 Ø PPR PIPE
ref ref ANGLE OR FROM THE TOP OF THE HORIZONTAL.
8. ALL PLUMBING WORKS SHALL BE DONE UNDER THE DIRECT SUPERVISION OF A SANITARY ENGINEER OR A MASTER PLUMBER.
PLANTERS PLANTERS
9. ALL CHANGES IN DIRECTION SHALL BE MADE IN APPROPRIATE USE OF 45° WYE LONG SWEEP QUARTER BEND.
BEDROOM 2 BEDROOM 2
10. ALL CHANGES IN DIRECTION SHALL BE MADE IN APPROPRIATE USE OF 45° WYES, LONG SWEEP QUARTER BENDS, HALF WYES EXCEPT
lav. lav.
THAT SINGLE
wc wc
SANITARY TEES MAY BE TO OTHER USED ON VERTICAL ATTACKS, AND SHORT QUARTER BENDS MAY BE USED IN SOIL AND WASTE LINES
T&B T&B
closet
closet
WHERE THE
LIVING ROOM LIVING ROOM
closet
closet
CHANGE IN THE DIRECTION OF FLOW IS FROM THE HORIZONTAL TO THE VERTICAL. TEES AND CROSSES MAY BE USED IN VENT PIPES.
sho. sho.
fd fd
DS
GVWMCV GV
M
BEDROOM 1 CB BEDROOM 1 11. NO DOUBLE HUB, DOUBLE T BRANCH SHALL BE USED ON HORIZONTAL SOIL OR WASTE LINE, THE DRILLING AND TAPPING OF HOUSE DRAIN,
1/2 Ø PPR PIPE
FROM WATER
SOURCE
SOIL WASTE
OR VENT PIPES AND THE USE OF SADDLE HUBS AND BEND ARE PROHIBITED.
2 PLANTERS 2 PLANTERS 14. VERIFY AND DETERMINE, SUBJECT TO THE ENGINEER/ARCHITECT'S APPROVAL THE BEST LOCATION AT WHICH TO CONNECT THE
1 1 DRAINAGE SYSTEM
TO EXISTING STREET DRAIN OR TO OTHER CONVENIENT ACCEPTABLE APPROVED WATER DISCHARGE RECEIVER IN ALL CASES, PROVIDE
UP UP STORM
DRAINAGE LINES WITH 2% MINIMUM SLOPE TOWARDS DIRECTIONS OF DRAIN.
LAV LAVATORY
1.00m
4 MANHOLE MANHOLE MANHOLE
M
OO
DR
BE clo
set 4
fd
OM
RO
B sh
o. BE
D
clo
set
fd
1OOmm Ø PVC
INLET PIPE
1OOmm Ø
PVC TEE 1OOmm Ø PVC
OUTLET PIPE
WC WATER CLOSET
T& wc
lav
.
B o.
sh
RS T&
TE wc PLAN
NK 3 AN
SE
PT
IC
TA
ED
R OO
M PL lav
.
TE
R S FD FLOOR DRAIN
B E K 3 AN
PIP TA
N
OM PL
PR IC CO RO 1OOmm Ø thick Concrete 1OOmm x 5OOmm x 5OOmm 15Omm CHB WALL w/ 12mm Ø
ØP PT D Slab w/ 12mm reinforcement Concrete Manhole w/ 3-1Omm Vertical Bars S.P @ 6OOmm
1/2 SE BE bars S.P. @ 125mm O.C. BW Bars B.W. & Bar Handel O.C & 12mm Ø Horizontal BarS
S.P @ every 3 layer of CHB
CO CO CO CO
t
se GV
GV GATE VALVE
E
PIP clo
RS PP
R 1
TE Ø OO
M
AN 1/2 R et
3OOmm Air Space
PL G BE
D
S clo
s
CB
1OOmm Ø PVC
AL 1 DS
1 IN ER M
INLET PIPE
NN clo
AN NT O
DI RO
2 se
t C A
PL
3
D
4
GE NG BE
INA CV
CV
DN
DR
A
1
2
3 DI
NN
I clo
set
1OOmm Ø
PVC Tee CHECK VALVE
4
ge TO
ran
DN
d
isl
an
OM ge
EN ran DIGESTIVE
2.00m
RO LEACHING LEACHING
sin
k
KIT
CH
LIV
IN
G
DS
CB an
d
M CHAMBER WELL 1 WELL 2
M M WATER METER
isl
ref EN OO
RS
H GR
H ITC
.
lav B RC k IN
T& TE sin K LIV
wc fd PO AN ref
2 PL S
E . H
o. B ER
M lav
RC
FAU FAUCET
PIP clo sh
R
PP R OO se
t T& PO NT
wc A
ED fd 16mm thick
PL
Ø 4
1/2 B 3 CONCRETE
2 2 o.
PLASTERING
1 OM clo sh
RO
se
t
D 4
E BE 3
2 CO
PIP
CO
1
CLEANOUT
0.20m
PR UP
ØP
1/2
E
AG
G AR UP
GRAVEL FILL
GE
CV
GV
DS
CB
GA
RA 0.40m CB CB CATCH BASIN
WM
GV M
TE
WA CE
OM UR
R
SECTION DS DOWNSPOUT
FR SO
4 WATER LINE ISOMETRIC VIEW 5 SEWER LINE ISOMETRIC VIEW 6 SEPTIC TANK DETAILS 7 PLUMBING NOTES
P 1 SCALE 1:1OO Mts. P 1 SCALE 1:1OO Mts. P 1 SCALE 1:1OO Mts. P 1 SCALE 1:1OO Mts.
ARCHITECT MASTER PLUMBER PROJECT TITLE & LOCATION APPROVED BY: DATE REVISION SHEET CONTENTS SHEET NO.
WATER LINE LAYOUT