P-06 Curve
P-06 Curve
P-06 Curve
DOCUMENT TITLE : Performance curves Rotary Pump 19-P-06A/B Pitch Product Pump
TOTAL No OF PAGES : 6
SUPLLIER'S ORDER No : 96100351
ENPPI PROJECT
PERMISSION TO PROCEED DOES NOT CONSTITUTE NUMBER
: 3800-210
ACCEPTANCE OR APPROVAL OF DESIGN DETAILS,
CALCULATIONS, ANALYSIS, TEST METHODS OR
MATERIALS DEVELOPED OR SELECTED BY SUPPLIER
FROM FULL COMPLIANCE WITH CONTRACTUAL PACKAGE
: Rotary Screw Pumps
OBLIGATIONS. DESCRIPTION
3
3800-210-PM1-FRM-0033
NAME:
96100351-A1002-0003 006
SIGNATURE: DATE :
1 of 6
NOTOS® MULTI SCREW PUMP CURVE
200
180
160
Flow, m³/h 140
120
100
80
60
40
20
0
0 2 4 6 8 10
80
70
60
Shaft power, kW
50
40
30
20
10
0
0 2 4 6 8 10
Differential pressure, bar
Operating Conditions
Normal
Max PSV (+1.1
Visc. PSV
Viscosity accumulation)
case
Rated
Fluid Pitch Pitch Pitch Pitch
Temperature °C 292 250 292 292
Viscosity cP 105 340 105 105
Relative Density - 0,95 0,95 0,95 0,95
Speed rpm 1455 1455 1455 1455
Differential pressure bar 4,38 4,38 6,14 7,656
Nominal flow m³/h 176,9 180 174 172
Minimum flow m³/h 176,9 - - -
Rated Capacity m³/h 176,9 - - -
Rated Suction Pressure barG 9,02 9,02 9,02 9,02
NPSHa mLc 5,5 5,5 5,5 5,5
NPSHr mLc 2,4 2,4 2,4 2,9
NPIPa bar(a) 0,52 0,52 0,52 0,52
NPIPr bar(a) 0,22 0,22 0,22 0,27
Shaft power kW 49,2 63,2 60,4 66,6
SPEED bar(a) 0,22 0,27 0,22 0,22
General information
End User MIDOR Name Gustavo Marega
Curve n° DE-LP0000150-313-003 Rev. Nr. 6
Ref. Nr. TAG 19-P-06 A/B Approval Rubem Bader
Customer Enppi
Pump data sheet reference document: 2544-19-SP-0931-02
Supplier document number: 96100351-A1001-0005/96100351-A1001-0006
2 of 6
NOTOS® MULTI SCREW PUMP CURVE
250
200
Flow, m³/h
150
100
50
0
0 500 1000 1500 2000 2500
80
70
Shaft power, kW
60
50
40
30
20
10
0
0 500 1000 1500 2000 2500
60%
50%
Efficiency
40%
30%
20%
10%
0%
0 500 1000 1500 2000 2500
3
NPSH required, m
2,5
2
1,5
1
0,5
0
0 500 1000 1500 2000 2500
Speed, rpm
Rated DIESEL Start-up VGO Start-up VGO
Operating Conditions
Rated Start-up Start-up Start-up
Fluid Pitch Diesel VGO VGO
Temperature °C 292 40 80 160
Viscosity cP 105 2,6 13,9 1,9
Relative Density - 0,95 0,805 0,885 0,834
Differential pressure bar 4,38 4,38 4,38 4,38
Speed rpm 1455 890 810 910
Nominal flow m³/h 176,9 88,4 88,4 88,4
Rated Capacity m³/h 176,9 - - -
Rated Suction Pressure barG 9,02 9,02 9,02 9,02
Shaft power kW 49,3 24,5 22,4 25,1
Volumetric Efficiency 90% 74% 81% 72%
Total efficiency 44% 44% 48% 43%
NPSHa mLc 5,5 5,5 5,5 5,5
NPSHr mLc 2,3 1,9 1,8 1,8
NPIPr bar(a) 0,22 0,15 0,16 0,15
3 of 6
NOTOS® MULTI SCREW PUMP CURVE
250
200
Flow, m³/h
150
100
50
0
0 500 1000 1500 2000 2500
90
80
Shaft power, kW
70
60
50
40
30
20
10
0
0 500 1000 1500 2000 2500
60%
50%
Efficiency
40%
30%
20%
10%
0%
0 500 1000 1500 2000 2500
3,5
3
NPSH required, m
2,5
2
1,5
1
0,5
0
0 500 1000 1500 2000 2500
Speed, rpm
Start-up Pitch Start-up Diesel
Operating Conditions
Start-up Start-up
Fluid VR VR
Temperature °C 160 292
Viscosity cP 183 3,4
Relative Density - 0,961 0,923
Differential pressure bar 4,38 4,38
Speed rpm 750 880
Nominal flow m³/h 88,4 88,4
Shaft power kW 27,4 24,3
Volumetric Efficiency 87% 75%
Total efficiency 39% 44%
NPSH available mLc 5,5 5,5
NPSH required mLc 2,1 2,7
NPIP bar(a) 0,2 0,15
4 of 6
MIDOR REFINERY EXPANSION PROJECT
GENERAL NOTES
1- NPSHr / NPIPr are constant for fixed speed, variable pressure and constant viscosity.
2- Revised performance curves and data sheets shall be submitted after the performance test to represent
data from the test that shall be as per acceptance criteria of governing specification in any case. Please
refer to API-676 para. 9.3.2.2.
3- Pump is suitable and able to operate all over the curve specified in the drawing A1002 with the same
capability with NPSHa provided
4- NPIPA&R (Pa) = NPSHA&R (m) * density * gravity acceleration
5- Max Suction pressure cases:
For rated viscosity 105 cP
5 of 6
MIDOR REFINERY EXPANSION PROJECT
6- Minimum flow conditions. The VFD is designed for rated conditions, however, for start up (low Viscosity)
conditions, pump speed can be lowered down due to torque reduction.