User’s Manual
DIRECTORY
1.4 Specifications........................................................................................................................................... 2
CHAPTER 4 TROUBLESHOOTING............................................................................................18
1.1 Outline
1.2 Features
Support 16 FTA DVB- S/S2 (DVB-C/T/T2 /ISDB-T/ATSC optional )input, 2 ASI input
Support BISS descrambling
Support DisEqc function
16 MPTS or 512 SPTS output (MPTS and SPTS output switchable)
2 GE mirrored output (IP address and port number of GE1 and GE2 are different), up to
850Mbps---SPTS
2 independent GE output port, GE1 + GE2---MPTS
Support PID filtering, re-mapping (Only for SPTS output)
Support “Null PKT Filter” function (Only for MPTS output)
1
1.3 Inner Principle
Tuner 1
X LD3508B
Tuner 2
Tuner 3
GE1
IP Output
IP Output
Tuner 15 GE2
Tuner 16
ASI Input1
ASI Input2
1.4 Specifications
2
1.5 Appearance and Description
1 Power indicator
2 Reset: Reset webmaster IP address, recover it to default IP address
1 16 channels RF IN Interface
2 Integrated power switch and socket
3 Grounding Wire
3
Chapter 2 Installation Guide
When users open the package of the device, it is necessary to check items according to
packing list. Normally it should include the following items:
XLD3508B Tuner to IP Gateway
User‟s Manual
Grounding Cable
RF In and Loop Out Cable
Power Cord
If any item is missing or mismatching with the list above, please contact local dealer.
When users install device, please follow the below steps. The details of installation will be
described at the rest part of this chapter. Users can also refer rear panel chart during the
installation.
The main content of this chapter including:
Checking the possible device missing or damage during the transportation
Preparing relevant environment for installation
Installing gateway
Connecting signal cables
Connecting communication port (if it is necessary)
Connecting
Grouding
Acquisition Fixing Connecting Setting Running
Wire and
Check Device Signal Wire Parameter Device
Power
Cord
When user installs machine frame array in one machine hall, the
Machine Hall Space distance between 2 rows of machine frames should be 1.2~1.5m
and the distance against wall should be no less than 0.8m.
Relative
20%~80% sustainable 10%~90% short time
Temperature
Pressure 86~105KPa
All function modules‟ good grounding designs are the basis of reliability and stability of
devices. Also, they are the most important guarantee of lightning arresting and
interference rejection. Therefore, the system must follow this rule.
Coaxial cable‟s outer conductor and isolation layer should keep proper electric
conducting with the metal housing of device.
Grounding conductor must adopt copper conductor in order to reduce high frequency
impedance, and the grounding wire must be as thick and short as possible.
Users should make sure the 2 ends of grounding wire well electric conducted and be
5
antirust.
It is prohibited to use any other device as part of grounding electric circuit
The area of the conduction between grounding wire and device‟s frame should be no less
than 25mm2.
All the machine frames should be connected with protective copper strip. The grounding wire
should be as short as possible and avoid circling. The area of the conduction between
grounding wire and grounding strip should be no less than 25mm2.
Connecting the device‟s grounding rod to frame‟s grounding pole with copper wire.
The grounding wire conductive screw is located at the right end of rear panel, and the power
switch, fuse, power supply socket is just beside ,whose order goes like this, power switch is
on the left ,power supply socket is on the right and the fuse is just between them.
Connecting Power Cord
User can insert one end into power supply socket, while insert the other end to AC power.
Connecting Grounding Wire
When the device solely connects to protective ground, it should adopt independent way,
say, share the same ground with other devices. When the device adopts united way, the
grounding resistance should be smaller than 1Ω.
Caution:
Before connecting power cord to NDS3508B Tuner to IP Gateway, user should set the
power switch to “OFF”.
6
Chapter 3 WEB NMS operation
User can only control and set the configuration in computer by connecting the device to web
NMS Port. User should ensure that the computer‟s IP address is different from the
XLD3508B‟s IP address; otherwise, it would cause IP conflict.
3.1 login
Figure-1
3.2 Operation
Summary → Status
When we confirm the login, it displays the status interface as Figure-2.
7
System information
Figure-2
16 Tuner input
status
8
Figure-3
Figure-3
16 Tuner input
status
Figure-4
9
Figure-5
Parameter→ BISS
From the menu on left side of the webpage, clicking “BISS”, it displays the interface where
users can configure BISS and descramble the input channels (Figure-6).
Figure-6
10
When users disable the ASI input, XLD3508B can support 16 Tuner input with 16 MPTS IP
output (Figure-7).
Figure-7
When users enable the ASI input, XLD3508B can support 1 4 Tuner input and 2 ASI input
with 16 MPTS IP output (Figure-8).
Figure-8
Parameter→ IP Stream
XLD3508B supports TS to output in IP (16*MPTS) format through the GE1 or GE2 port.
Clicking “IP Stream”, it displays the interface where to set IP out parameters (Figure-9).
11
Figure-9
NDS3508B support 16 Tuner input and 2 ASI input with 512 SPTS output, the parameter
interface is different from MPTS. When users switch MPTS to SPTS, new mode will work
after reboot the device.
Parameter→ TS Config
Clicking “TS Config”, it displays the interface where users can set the output TS and
configure TS ID and ON ID (Figure-10).
Figure-10
Parameter→ BISS:
From the menu on left side of the webpage, clicking “BISS”, it displays the interface where
users can configure BISS and descramble the input channels (Figure-11).
12
Figure-11
Operation Area
Figure-12
Configure „Input Area‟ and „Output Area‟ with buttons in „Operation Area‟. Instructions are as
below:
Select one input program first and click this button to transfer the selected
program to the right box to output.
Similarly, user can cancel the multiplexed programs from the right box.
To select all the input programs
To select all the output programs
Program Modification:
The multiplexed program information can be modified by clicking the program in the „output‟
area. For example, when clicking , it triggers a dialog box (Figure 13) where
users can input new information.
Figure-13
System → Network:
Clicking “Network”, it displays the interface as Figure-14 where to set network parameters.
14
Figure-14
System → Password:
From the menu on left side of the webpage, clicking “Password”, it displays the screen as
Figure-15 where to set the login account and password for the web NMS.
Figure-15
System → Save/Restore:
From the menu on left side of the webpage, clicking “Save/Restore”, it displays the screen
as Figure-16 where to save or restore your configurations.
15
Figure-16
System → Backup/Load:
From the menu on left side of the webpage, clicking “Backup/Load”, it displays the screen
as Figure-17 where to backup or load your configurations.
Figure-17
System → Firmware:
From the menu on left side of the webpage, clicking “Firmware”, it displays the screen as
Figure-18 where to update firmware for the device.
16
Select IP output
Mode, click “Apply”
and reboot the device
then the new mode
can start to work.
Figure-18
17
Chapter 4 Troubleshooting
XIELID s ISO9001 quality assurance system has been approved by CQC organization. For
guarantee the products‟ quality, reliability and stability. All our products have been passed
the testing and inspection before ship out factory. The testing and inspection scheme already
covers all the Optical, Electronic and Mechanical criteria which have been published by
us. To prevent potential hazard, please strictly follow the operation conditions.
Prevention Measure
Making sure good ventilation for the heat-sink on the rear panel and other heat-sink bores
if necessary
Checking the input AC within the power supply working range and the connection is
correct before switching on device
Checking the RF output level varies within tolerant range if it is necessary
Checking all signal cables have been properly connected
Frequently switching on/off device is prohibited; the interval between every switching
on/off must greater than 10 seconds.
18
Chapter 5 Packing list
XLD3508B Tuner to IP gateway
User‟s manual
Grounding cable
RF In and Loop Out Cable
Power cord
19