MXPRG

The document contains settings for a PLC system including timer limits, RUN-PAUSE contacts, latch data backup functions, remote reset settings, and more. Interrupt, module synchronization, compatibility, and other PLC configuration settings are also included.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
23 views28 pages

MXPRG

The document contains settings for a PLC system including timer limits, RUN-PAUSE contacts, latch data backup functions, remote reset settings, and more. Interrupt, module synchronization, compatibility, and other PLC configuration settings are also included.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 28

Title

Comment

Prepared By

Date
PLC Parameter 5/22/2024
Data Name : PLC System
PLC System
[Timer Limit Setting]
Low Speed 100 ms
High-Speed 10.00 ms

[RUN-PAUSE Contacts]
RUN X
PAUSE X

[Latch Data Backup Function]


Device Name - -
-

[Remote Reset]
Not allowed

[Output Mode at STOP to RUN]


Previous State

[Floating Point Arithmetic Processing]


-

[Common Pointer No. ]


P2048 After

[Points Occupied by Empty Slot]


16 Points

[System Interrupt Settings]


Interrupt Counter Start No. -
I28 Fixed Scan Interval 100.0 ms
I29 Fixed Scan Interval 40.0 ms
I30 Fixed Scan Interval 20.0 ms
I31 Fixed Scan Interval 10.0 ms

[Interrupt Program / Fixed Scan Program Setting]


High-Speed Execution is not valid

[Module Synchronization]
Synchronize intelligent module's pulse up

[A-PLC Compatibility Setting]


Use of special relay / special register from SM/SD 1000 is not valid

[Service Processing Setting]


Execute the process as the scan time proceed 10 %

[PLC Module Change Setting]


No setting

[Built-in CC-Link Setting]


-

1
PLC Parameter 5/22/2024
Data Name : PLC File
PLC File
[File Register]
Not Used

[Comment File Used in a Command]


Not Used

[Device Initial Value]


Not Used

[File for Local Device]


Not Used

[File used for SP.DEVST/S.DEVLD Instruction


Not Used

2
PLC Parameter 5/22/2024
Data Name : PLC RAS
PLC RAS
[WDT(Watchdog Timer)Setting]
WDT Setting 200 ms
Initial Execution Monitoring Time ms
Low Speed Execution Monitoring Time - ms

[Error Check]
Battery Check Valid
Fuse Blown Check Valid
I/O Module Verify Valid
Check Device Range at Indexing Valid
Diagnose Redundant Power Supply System Valid
[Operating Mode When There is an Error]
Computation Error Stop
Expanded Command Error Stop
Fuse Blown Stop
Module Verify Error Stop
Intelligent Module Program Execution Error Stop
File Access Error Stop
Memory Card Operation Error Stop
External Power Supply OFF Stop

[Constant Scanning]
ms

[Error history]
-
Target Memory -
File Name -
History No. - Item

[Low Speed Program Execution Time]


- ms

[Module Error History Collection (Intelligent Function Module


Collection of intelligent function module error histories is val
Target Memory System Memory
History No. - Item
Collection No. 1 Items/Scan

3
PLC Parameter 5/22/2024
Data Name : Boot File
Boot File
[Boot Option]
Clear Program Memory is not valid.
High-Speed Monitor Area from Other Station- K Steps
Online Change Area of Multiple Blocks - K Steps

4
PLC Parameter 5/22/2024
Data Name : SFC
SFC
[SFC Program Start Mode]
Initial Start

[Start Conditions]
Autostart Block 0

[Output Mode When the Block is Stopped]


Turn OFF

5
PLC Parameter 5/22/2024
Data Name : Device
Device
[Device]
Device Latch (1) Latch (1) Latch (2) Latch (2) Local Device Local Device Write Protection Write Protection
Sym. Dig.
Points Start End Start End Start End Start End
Input Relay X 16 8K
Output Relay Y 16 8K
Internal Relay M 10 8K
Latch Relay L 10 8K
Link Relay B 16 8K
Annunciator F 10 2K
Link Special SB 16 2K
Edge Relay V 10 2K
Step Relay S 10 8K
Timer T 10 2K
Retentive Timer ST 10 0K
Counter C 10 1K
Data Register D 10 12K
Link Register W 16 8K
Link Special SW 16 2K
Index Z 10 20

Device Total 28.8 K Words


Word Device 25.0 K Words
Bit Device 44.0 K Bits

6
PLC Parameter 5/22/2024
Data Name : Device
Device
[File Register Extended Setting]

Capacity K Points

Device Latch (1) Latch (1) Latch (2) Latch (2) Device No. Device No. Write Protection Write Protection
Sym. Dig.
Points Start End Start End Start End Start End
File Register ZR(R) 10 0K
Extended Data D 10 0K
Extended Link W 16 0K

7
PLC Parameter 5/22/2024
Data Name : Device
Device
[Indexing Setting for ZR Device]
32Bit Indexing Z After

[Latch Interval Setting]


-

[Pointer Extended Setting for Automatic-Assign Device


-

8
PLC Parameter 5/22/2024
Data Name : I/O Assignment
I/O Assignment
[I/O Assignment]

Main
PLC 0 1 2 3 4 5 6 7
PLC Intelligent
Power
Supply
- 32Points
QD77MS2
Start XY - 0000
Error Time - Clear - - - - - - -
Output
Mode
PLC - Stop - - - - - - -
Operation
Mode at
H/W Error
I/O - - - - - - - - -
Response
Time
Control PLC - - - - - - - - -
1 - - - - - - - -
Switch Setting

2 - - - - - - - -
3 - - - - - - - -
4 - - - - - - - -
5 - - - - - - - -

9
PLC Parameter 5/22/2024
Data Name : Serial Communication
Serial Communication
[Serial Communication]
Serial communication is not valid

10
PLC Parameter 5/22/2024
Data Name : Acknowledge XY Assignment
Acknowledge XY Assignment
[Acknowledge XY Assignment]
Type
XY No. Slot Module Type Points Model Name Duplication
Network I/O Assignment
0000 I/O Assignment 0(*- 0) Intelligent 32 Points QD77MS2
0010 I/O Assignment 0(*- 0) Intelligent 32 Points QD77MS2

11
Network Parameter 5/22/2024
Data Name : Ethernet/CC IE/MELSECNET
Ethernet/CC IE/MELSECNET
[Ethernet/CC IE/MELSECNET]
Valid Module During Other Station Access1
Interlink Transmission Parameters No setting
Routing Parameters No setting

12
Network Parameter 5/22/2024
Data Name : Ethernet/CC IE/MELSECNET
Ethernet/CC IE/MELSECNET
[Ethernet/CC IE/MELSECNET]
Module 1 Module 2 Module 3 Module 4
Network Type None None None None
Start I/O No. - - - -
Network No. - - - -
Total Stations - - - -
Group No. - - - -
Station No. - - - -
Mode - - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -

13
Network Parameter 5/22/2024
Data Name : Ethernet/CC IE/MELSECNET
Ethernet/CC IE/MELSECNET
[Ethernet/CC IE/MELSECNET]
Module 5 Module 6 Module 7 Module 8
Network Type None None None None
Start I/O No. - - - -
Network No. - - - -
Total Stations - - - -
Group No. - - - -
Station No. - - - -
Mode - - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -

14
Network Parameter 5/22/2024
Data Name : Ethernet/CC IE/MELSECNET
Ethernet/CC IE/MELSECNET
[Ethernet/CC IE/MELSECNET]
Module 9 Module10 Module11 Module12
Network Type None None None None
Start I/O No. - - - -
Network No. - - - -
Total Stations - - - -
Group No. - - - -
Station No. - - - -
Mode - - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -

15
Network Parameter 5/22/2024
Data Name : Ethernet/CC IE/MELSECNET
Ethernet/CC IE/MELSECNET
[Ethernet/CC IE/MELSECNET]
Module13 Module14 Module15 Module16
Network Type None None None None
Start I/O No. - - - -
Network No. - - - -
Total Stations - - - -
Group No. - - - -
Station No. - - - -
Mode - - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -

16
Network Parameter 5/22/2024
Data Name : Ethernet/CC IE/MELSECNET
Acknowledge XY Assignment
[Acknowledge XY Assignment]
Type
XY No. Slot Module Type Points Model Name Duplication
Network I/O Assignment
0000 I/O Assignment 0(*- 0) Intelligent 32 Points QD77MS2
0010 I/O Assignment 0(*- 0) Intelligent 32 Points QD77MS2

17
Network Parameter 5/22/2024
Data Name : CC-Link
CC-Link Setting
[CC-Link Setting]

Number of Modules Boards

18
Network Parameter 5/22/2024
Data Name : CC-Link
CC-Link Setting
[CC-Link Setting]
1 2 3 4
Start I/O No. - - - -
Type - - - -
Master Station Data Link Type - - - -
Mode - - - -
Total Module Connected - - - -
Remote input(RX) - - - -
Remote output(RY) - - - -
Remote register(RWr) - - - -
Remote register(RWw) - - - -
Ver.2 Remote input(RX) - - - -
Ver.2 Remote output(RY) - - - -
Ver.2 Remote register(RWr) - - - -
Ver.2 Remote register(RWw) - - - -
Special relay(SB) - - - -
Special register(SW) - - - -
Retry Count - - - -
Automatic Reconnection Station Count - - - -
Standby Master Station No. - - - -
PLC Down Select - - - -
Scan Mode Setting - - - -
Delay Time Setting - - - -
Remote Device Station Initial Setting - - - -
Interrupt Settings - - - -

19
Network Parameter 5/22/2024
Data Name : CC-Link
Acknowledge XY Assignment
[Acknowledge XY Assignment]
Type
XY No. Slot Module Type Points Model Name Duplication
Network I/O Assignment
0000 I/O Assignment 0(*- 0) Intelligent 32 Points QD77MS2
0010 I/O Assignment 0(*- 0) Intelligent 32 Points QD77MS2

20
Program setting 5/22/2024
Data Name : Program setting
Execution type Program file name Local Task name Task attribute
[Title] device comment [Title]
Initial Program - - - -

Scan Program - - - -

Standby Program - - - -

Fixed Scan Program - - - -

No Execution Type MAIN None Task_01 Priority (31), Always

21
Program setting 5/22/2024
Data Name : Task_01

Task Setting

Program Name Comment


1 POU_01

22
Structured Ladder/FBD 5/22/2024
Data Name : POU_01

23
Label 5/22/2024
Data Name : Global1
Global Label Setting
Class Label Name Data Type Constant Device Address Comment Remark Relation with System Label System Label Name Attribute

24
Label 5/22/2024
Data Name : POU_01
Local Label Setting
Class Label Name Data Type Constant Device Address Comment

25
Device List 5/22/2024
Data Name : Device List

Find In:(Entire project)


Find What:Used Device (Contact & Coil)
Print Range:Whole Range

*:in use, (counts): the number of coil uses

Device Contact Coil (counts) Parameter Comment

26
Project Contents List 5/22/2024
Data Name : Project Contents List
Workspace Name :
Project Name :
Title :

Data Name Last Change Title


Parameter 4/19/2024 6:24:42 AM
PLC Parameter 4/19/2024 6:24:42 AM
Network Parameter 4/19/2024 6:24:42 AM
Ethernet / CC IE / MELSECNET 4/19/2024 6:24:42 AM
CC-Link 4/19/2024 6:24:42 AM
Remote Password 4/19/2024 6:24:42 AM
Intelligent Function Module 4/28/2024 3:29:23 PM
0000:QD77MS2 4/28/2024 3:29:23 PM
Simple Motion Module Setting
Auto_Refresh
Global Device Comment 4/19/2024 6:24:43 AM
Global Label 4/19/2024 6:24:43 AM
Global1 4/19/2024 6:24:43 AM
Program Setting
Initial Program
Scan Program
Standby Program
Fixed Scan Program
No Execution Type
MAIN 4/19/2024 6:24:44 AM
Task_01 4/19/2024 6:24:44 AM
POU_01 5/22/2024 8:15:37 PM
Program 5/22/2024 8:15:37 PM
Local Label 4/19/2024 6:24:43 AM
POU
Program 4/19/2024 6:24:43 AM
POU_01 5/22/2024 8:15:37 PM
Program 5/22/2024 8:15:37 PM
Local Label 4/19/2024 6:24:43 AM
FB/FUN 4/19/2024 6:24:42 AM
Structured Data Types 4/19/2024 6:24:42 AM
Local Device Comment
Device Memory 4/19/2024 6:24:44 AM
MAIN 4/19/2024 6:24:44 AM
Device Initial Value 4/19/2024 6:24:42 AM

27

You might also like