Sobrepena, Andrei Jhon D. - Cengr 3210 - Bungalow

Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

TABLE OF CONTENTS Republic of the Philippines

Department of Public Works and Highways


OFFICE OF THE BUILDING OFFICIAL
ARCHITECTURAL
A-1 PERSPECTIVE SAN MIGUEL, NATIVIDAD, PANGGASINAN
SITE DEVELOPMENT PLAN
LOCATION MAP DISTRICT/CITY/MUNICIPALITY
TABLE OF CONTENTS
A-2 GROUND FLOOR PLAN
FRONT ELEVATION
RIGHT SIDE ELEVATION
SCHEDULE OF DOORS AND WINDOWS
A-3 LEFT SIDE ELEVATION LAND USE AND ZONING
REAR ELEVATION
SECTION THRU X
SECTION THRU Y
ROOF PLAN
LINE AND GRADE
STRUCTURAL
S-1 FOUNDATION PLAN
ROOF BEAM PLAN
TYPICAL COLUMN FTG. DETAILS
TYPICAL WALL FTG. DETAILS ARCHITECTURAL
TYPICAL BEAM DETAILS
SLAB DETAILS
S-2 TRUSS DIAGRAM
ROOF FRAMING PLAN
SCHEDULE OF REINFORCEMENT BEAM
SCHEDULE OF COLUMN STRUCTURAL
SCHEDULE OF FOOTING
TYPICAL STEEL TRUSS DETAILS
P E R S P E C T I V E
SANITARY
ELECTRICAL
RICE FIELD
ELECTRICAL
18.00m 1.00m
E-1 GROUND FLOOR LIGHTING LAYOUT
GROUND FLOOR POWER LAYOUT
ELECTRICAL LEGENDS
E-2 SCHEDULE OF ELECTRICAL LOADS
PROPOSED RISER DIAGRAM
14.00m

4-BEDROOM EXISTING RESIDENTIAL


RICE FIELD GENERAL ELECTRICAL NOTES

ROAD
BUILDING
BUNGALOW EXISTING RESIDENTIAL
BUILDING
MECHANICAL
EXISTING

.
RESIDENTIAL
BR GY . ROAD
BUILDING
PLUMBING

BRGY
EXISTING RESIDENTIAL BUILDING
P-1 GROUND FLOOR WATER LINE LAYOUT
GROUND FLOOR SANITARY LINE LAYOUT ELECTRONICS
GROUND FLOOR WATER LINE ISO LAYOUT
GROUND FLOOR SANITARY LINE ISO LAYOUT
B R G Y. R O A D
P-2 SEPTIC TANK DETAILS
CATCH BASIN DETAILS
FLOOR CLEAN OUT DETAILS
SCALE: FLOOR DRAIN DETAILS
PLUMBING LEGENDS GEODETIC
LOCATION MAP SITE DEVELOPMENT PLAN PLUMBING NOTES
NTS SCALE: NTS
CIVIL ENGINEER: DESIGNED AND CADD BY: REVISIONS: DATE: PROJECT TITLE: OWNER: SHEET CONTENTS: SHEET NO:
ANDREI JHON D. SOBREPEÑA PROPOSED 4-BEDROOM BUNGALOW
ENGR. RITCHIE C. MALASAN
CHECKED BY:
PROJECT LOCATION:

(AT = 160 m2)


ADDRESS:
TABLE OF CONTENTS
PERSPECTIVE A-1
ENGR. RITCHIE C. MALASAN SAN MIGUEL, NATIVIDAD, PANGASINAN SITE DEVELOPMENT PLAN
1 9
PRC REG NO: PTR NO: LOCATION MAP
VALIDITY: DATE ISSUED: DATE: SAN MIGUEL, NATIVIDAD, PANGASINAN DATE APPROVED:
TIN: PLACE ISSUED:
MAY 10, 2024 MAY 10, 2024
16000
4400 1950 2650 3000
2000 1200 2750 450 1900 1200 3000 1500 2000
1000
TOP OF FIREWALL
300

ROOF APEX
1500

LANAI
LAUNDRY DIRTY KITCHEN
AREA SERVICE AREA
2000

3000

0.4MM THK
KITCHEN AREA G.I. LONG SPAN ROOF
2389
1500

DINING TABLE
T.O.B
500

2000

T&B
BEDROOM 1 BEDROOM 2
2500
9500

T&B

3100
PANTRY AREA
GUEST ROOM
F.F.L
1500

T&B
LIVING AREA PAINTED CEMENT

1000
PLASTER WALL FINISH
5000

N.G.L
TERRACE
3000

PORCH
T&B
MASTER'S BEDROOM
CARPORT
FRONT ELEVATION
2000 4000 3500 3000 SCALE: 1:150
3500
PROPERTY LINE
GROUND FLOOR PLAN
SCALE: 1:150
TOP OF FIREWALL
300

ROOF APEX
PAINTED CEMENT
2389

PLASTER WALL FINISH 1800 800 1800 600 1550 1700 850 600
W-1 W-2 W-3 W-4
D-1 D-2 D-3 D-4
T.O.B

600
1200

1200

1200
2100

2100

2100
2100

1500
900

900

900
F.F.L
3100

PVC DOOR WIDE PANEL ALUMINUM SLIDING


TYPE WOOD 2 PANEL DOOR WOOD PANEL DOOR ALUMINUM SLIDING DOOR TYPE 2 PANEL ALUMINUM SLIDING WINDOW
WINDOW
ALUMINUM SLIDING WINDOW ALUMINUM AWNING WINDOW
F.F.L
SET 1 4 1 6 SET 2 4 6 3
BEDROOM 1, BEDROOM 2, MASTER'S BEDROOM'S DINING AREA, MASTER'S BEDROOM, KITCHEN AREA, LAUNDRY AREA,
LOCATION MAIN ENTRANCE DOOR GUESS ROOM, T&B, LANAI, LAUNDRY AREA
LOCATION TOILET AND BATHROOM
T&B LIVING AREA BEDROOMS 1, 2 & GUESS ROOM T&B OF MASTER'S BED
1000

MASTER'S BEDROOM
N.G.L
SCHEDULE OF DOORS SCHEDULE OF WINDOWS
SCALE: 1:150 SCALE: 1:150
RIGHT SIDE ELEVATION
SCALE: 1:150
CIVIL ENGINEER: DESIGNED AND CADD BY: REVISIONS: DATE: PROJECT TITLE: OWNER: SHEET CONTENTS: SHEET NO:
ANDREI JHON D. SOBREPEÑA PROPOSED 4-BEDROOM BUNGALOW
ENGR. RITCHIE C. MALASAN
CHECKED BY:
PROJECT LOCATION:

(AT = 160 m2)


ADDRESS:
GROUND FLOOR PLAN
FRONT ELEVATION A-2
ENGR. RITCHIE C. MALASAN SAN MIGUEL, NATIVIDAD, PANGASINAN RIGHT-SIDE ELEVATION
2 9
PRC REG NO: PTR NO:
SCHEDULE OF DOORS AND WINDOWS
VALIDITY: DATE ISSUED: DATE: SAN MIGUEL, NATIVIDAD, PANGASINAN DATE APPROVED:
TIN: PLACE ISSUED:
MAY 10, 2024 MAY 10, 2024
TOP OF FIREWALL TOP OF FIREWALL
300

ROOF APEX
300

ROOF APEX
2389 0.4MM THK
2389

G.I. LONG SPAN ROOF


0.4MM THK
T.O.B G.I. LONG SPAN ROOF
T.O.B

3100
3100

F.F.L F.F.L
PAINTED CEMENT PAINTED CEMENT

1000
1000

PLASTER WALL FINISH PLASTER WALL FINISH


N.G.L N.G.L
LEFT SIDE ELEVATION REAR ELEVATION
SCALE: 1:150 SCALE: 1:150
ROOF APEX TOP OF FIREWALL
ROOF PLAN

300
SCALE: 1:150 ROOF APEX
2389

SEE TRUSS DETAILS SEE TRUSS DETAILS

2389
T.O.B
T.O.B
3100

3100
F.F.L
F.F.L
1000

1000
N.G.L
N.G.L
SECTION THRU Y SECTION THRU X
SCALE: 1:150 SCALE: 1:150
CIVIL ENGINEER: DESIGNED AND CADD BY: REVISIONS: DATE: PROJECT TITLE: OWNER: SHEET CONTENTS: SHEET NO:
ANDREI JHON D. SOBREPEÑA PROPOSED 4-BEDROOM BUNGALOW LEFT SIDE ELEVATION
ENGR. RITCHIE C. MALASAN
CHECKED BY:
PROJECT LOCATION:

(AT = 160 m2)


ADDRESS:
REAR ELEVATION
SECTION THRU X
A-3
ENGR. RITCHIE C. MALASAN SAN MIGUEL, NATIVIDAD, PANGASINAN SECTION THRU Y
3 9
PRC REG NO: PTR NO:
VALIDITY: DATE ISSUED: DATE: SAN MIGUEL, NATIVIDAD, PANGASINAN ROOF PLAN
DATE APPROVED:
TIN: PLACE ISSUED:
MAY 10, 2024 MAY 10, 2024
6
REF
11
9
10
4
8
3
1 5
2
7
M M
GROUND FLOOR LIGHTING LAYOUT GROUND FLOOR POWER LAYOUT
SCALE: 1:150 SCALE: 1:150
LEGENDS:
DUPLEX SWITCH LIGHT FIXTURE
TRIPLEX SWITCH RECESSED LIGHT
CONVENIENCE SUSPENDED LIGHTS
OUTLET
REF OUTLET PANEL BOARD
AC OUTLET SWITCH
WEATHER PROOF
OUTLET
ELECTRICAL LEGENDS
SCALE: NTS
CIVIL ENGINEER: DESIGNED AND CADD BY: REVISIONS: DATE: PROJECT TITLE: OWNER: SHEET CONTENTS: SHEET NO:
ANDREI JHON D. SOBREPEÑA PROPOSED 4-BEDROOM BUNGALOW
ENGR. RITCHIE C. MALASAN
CHECKED BY:
PROJECT LOCATION:

(AT = 160 m2)


ADDRESS:
GROUND FLOOR LIGHTING LAYOUT
GROUND FLOOR POWER LAYOUT
E-1
ENGR. RITCHIE C. MALASAN SAN MIGUEL, NATIVIDAD, PANGASINAN
6 9
PRC REG NO: PTR NO: ELECTRICAL LEGENDS
VALIDITY: DATE ISSUED: DATE: SAN MIGUEL, NATIVIDAD, PANGASINAN DATE APPROVED:
TIN: PLACE ISSUED:
MAY 10, 2024 MAY 10, 2024
M
C O M P U T A T I O N O F L O A D S SERVICE ENTRANCE
LOAD DESCRIPTION RATING # OF OUTLETS VA VOLTS AMPS WIRE CB CONDUIT
1 LIGHTING OUTLET 100 VA 10 1000 230 4.35 2-2.0 mm² TW WIRE 15 AT 13 mm 100 AT
2 LIGHTING OUTLET 100 VA 9 900 230 3.91 2-2.0 mm² TW WIRE 15 AT 13 mm
L.O. 1 2 L.O.
3 LIGHTING OUTLET 100 VA 10 1000 230 4.35 2-2.0 mm² TW WIRE 15 AT 13 mm 15 AT 15 AT
4 LIGHTING OUTLET 100 VA 8 800 230 3.48 2-2.0 mm² TW WIRE 15 AT 13 mm
5 CONVENIENCE OUTLET 180 VA 6 1080 230 4.70 2-2.0 mm² TW WIRE 15 AT 13 mm L.O. 3 15 AT 15 AT
4 L.O.
6 CONVENIENCE OUTLET 180 VA 6 1080 230 4.70 2-2.0 mm² TW WIRE 15 AT 13 mm
7 0.75HP WINDOW TYPE AIR CONDITIONER 560 VA 1 560 230 2.43 2-3.5 mm² TW WIRE 30 AT 13 mm C.O. 5 6 C.O.
15 AT 15 AT
8 0.75HP WINDOW TYPE AIR CONDITIONER 560 VA 1 560 230 2.43 2-3.5 mm² TW WIRE 30 AT 13 mm
9 0.75HP WINDOW TYPE AIR CONDITIONER 560 VA 1 560 230 2.43 2-3.5 mm² TW WIRE 30 AT 13 mm
ACU 7 8 ACU
30 AT 30 AT
10 0.75HP WINDOW TYPE AIR CONDITIONER 560 VA 1 560 230 2.43 2-3.5 mm² TW WIRE 30 AT 13 mm
11 REFRIGERATOR OUTLET 750 VA 1 230 3.26 2-3.5 mm² TW WIRE 30 AT 13 mm
12 SPARE
ACU 9 30 AT 30 AT
10 ACU
REF. 11 12 SPARE
30 AT 30 AT
TOTAL WATTAGE EXCEPT ACU:
LIGHTING OUTLETS
CONVENIENCE OUTLETS
3700 WATTS
2160 WATTS SCHEDULE OF ELECTRICAL LOADS
CKT 11 750 WATTS SCALE: NTS
TOTAL = 6610 WATTS
6610 WATTS
4 UNITS ACU @ 560 WATTS 2240 WATTS
TOTAL = 8850 WATTS GROUND
PANEL BOARD DIAGRAM
I = [8850 + 25%(560 )]/230 V
SCALE: NTS
ELECTRICAL NOTES:
I = 39.09 Amperes
WIRE : FOR 39.09 AMP, USE 2 - 30 mm² TW
Main Feeder : Use no. 10
1.ALL ELECTRICAL WORKS AND INSTALLATION SHALL COMPLY WITH THE
COPPER WIRE FOR MAIN FEEDER AND 1 - 14 mm² TW PROVISION OF LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE WITH THE AWG THHN Copper Wire
COPPER WIRE FOR NEUTRAL LINE.
RULES AND REGULATIONS OF THE NATIONAL AND AUTHORITIES CONCERNED IN THE on 20 mm dia. PVC Pipe
CIRCUIT BREAKER : FOR 39.09 AMP, USE 100 ENFORCEMENT OF THE LOCAL ELECTRICAL LAWS AND REGULATIONS OF THE
AMPERES CIRCUIT BREAKER. UTILITY COMPANIES CONCERNED.
2.SERVICE VOLTAGE TO THE BUILDING SHALL BE 220 V,60Hz, SINGLE PHASE.
CONDUIT : USE 32 mm CONDUIT PIPE.
3.PULL BOXES OF THE APPROPRIATE SIZE SHALL BE PROVIDED EVEN IF NOT 30 AT
INDICATED IN THE DRAWINGS TO ACCOMMODATE THE NUMBER OF SPLICES OF
WIRES.
4.ALL MATERIALS TO BE USED MUST BE BRAND NEW AND APPROVED TYPE
APPROPRIATE SIZED FOR BOTH LOCATION AND INTENDED USED.
5.ALL ELECTRICAL INSTALLATION SHALL BE UNDER DIRECT SUPERVISION OF A
DULY LICENSED ELECTRICAL ENGINEER OR REGISTERED MASTER ELECTRICIAN.
6.SERVICE ENTRANCE SHALL BE INSTALLED IN ACCORDANCE WITH THE
PB
REGULATION OF THE LOCAL POWER COMPANY.
SERVICE ENTRANCE: 60
7.NO JOINTS AND SPLICES SHALL BE ALLOWED INSIDE THE CONDUIT RUN IN Hz 2 wires, single phase
ANY CIRCUIT AND JUNCTION BOXES SHALL BE LOCATED PROPERLY.
8.ALL WIRING INSTALLATION SHALL BE RUN IN POLYVINYL CHLORIDE (PVC)
PIPE HEAVY DUTY WITH NECESSARY FITTINGS EMBEDDED IN CONCRETE OR
MASONRY, INSIDE DOUBLE WALLING PARTITION OR ABOVE CEILING LINE.
9.WALL SNAP SWITCHES ARE TO BE INSTALLED 1,300mm-1,500mm ABOVE M
FINISH FLOOR LINE, CONVENIENCE OUTLET SHALL BE 300mm ABOVE FINISH FLOOR
LINE AND THE POWER PANEL SHALL BE 1,800mm-2,000mm ABOVE FINISH FLOOR LINE.
10.NO REVISION IN THE DESIGN SHALL BE DONE WITHOUT THE PRIOR
ACKNOWLEDGE AND APPROVAL OF THE DESIGNER AND OWNER, ANY REVISION
DONE WITHOUT APPROVAL SHALL CAUSE RESPONSIBILITY OF THE DESIGNER TO
CEASE AS A WHOLE.
RISER DIAGRAM
SCALE: NTS
ELECTRICAL NOTES
SCALE: NTS
CIVIL ENGINEER: DESIGNED AND CADD BY: REVISIONS: DATE: PROJECT TITLE: OWNER: SHEET CONTENTS: SHEET NO:
ANDREI JHON D. SOBREPEÑA PROPOSED 4-BEDROOM BUNGALOW
ENGR. RITCHIE C. MALASAN
CHECKED BY:
PROJECT LOCATION:

(AT = 160 m2)


ADDRESS:
SCHEDULE OF ELECTRICAL LOADS
RISER DIAGRAM
E-2
ENGR. RITCHIE C. MALASAN SAN MIGUEL, NATIVIDAD, PANGASINAN
7 9
PRC REG NO: PTR NO: GENERAL ELECTRICAL NOTES
VALIDITY: DATE ISSUED: DATE: SAN MIGUEL, NATIVIDAD, PANGASINAN DATE APPROVED:
TIN: PLACE ISSUED:
MAY 10, 2024 MAY 10, 2024
CO
MH SEPTIC TANK
CB DS CB DS
3
4 '' Ø PVC PIPE KS 3'' Ø PVC PIPE KS
KS CB KS
FA FD
DS
LAV LAV
TS WC FD TS WC
WC LAV WC LAV
1
'' Ø PVC PIPE FD
2
TS TS
WC FD WC
CB
TS DS TS
LAV LAV
TS FD
LAV LAV
TS
WC WC
CB
CV M GV FROM THE MAIN DS
WATER SOURCE
M

TO THE NEAREST
EXISTING DRAINAGE LINE
SANITARY LINE LAYOUT
WATER LINE LAYOUT SCALE: 1:150
SCALE: 1:150
SANITARY LINE ISO LAYOUT
WATER LINE ISO LAYOUT SCALE: 1:150
SCALE: 1:150
CIVIL ENGINEER: DESIGNED AND CADD BY: REVISIONS: DATE: PROJECT TITLE: OWNER: SHEET CONTENTS: SHEET NO:
ANDREI JHON D. SOBREPEÑA PROPOSED 4-BEDROOM BUNGALOW
ENGR. RITCHIE C. MALASAN
CHECKED BY:
PROJECT LOCATION:

(AT = 160 m2)


ADDRESS:

GROUND FLOOR WATER LINE LAYOUT


GROUND FLOOR SANITARY LINE LAYOUT P-1
ENGR. RITCHIE C. MALASAN SAN MIGUEL, NATIVIDAD, PANGASINAN GROUND FLOOR WATER LINE ISO LAYOUT
8 9
PRC REG NO: PTR NO:
GROUND FLOOR SANITARY LINE ISO LAYOUT
VALIDITY: DATE ISSUED: DATE: SAN MIGUEL, NATIVIDAD, PANGASINAN DATE APPROVED:
TIN: PLACE ISSUED:
MAY 10, 2024 MAY 10, 2024
4" PVC SOIL PIPE LAV. FAUCET
HCG LAVATORY
2000 2000 1500 100MM PEDESTAL TYPE
(2) VENT
10mm REBARS
@0.20m O.C B.W
500 500 500 LEGENDS:
100mm (2) P-TRAP SK SINK
800mm
16MM PLAIN
SANITARY TEE CO CLEANOUT
ROUND BAR 500 1500
RETRACTABLE FD FLOOR DRAIN
PULL HANDLE
WASTE LINE
FC FAUCET
WC WATER CLOSET
PLAN
CB CATCH BASIN
LAVATORY DETAILS KS KITCHEN SINK
SCALE: NTS HB HOSE BIBB
LEACHING
4'' PVC TEE WITH ST SEPTIC TANK
CLEAN OUT
DIGESTIVE CHAMBER CHAMBER
1.8m HEIGHT
FLOOR DRAIN SHO. SHOWER
(STAINLESS w/
4'' PVC TEE WITH SOIL SCREEN & STRAINER) 1 WATER METER
PIPE
AIR SPACE
NATURAL GROUND
LINE TILE FINISH FLOOR
12mm VERTICAL &
HORIZONTAL BARS 5'' CHB PLASTERED
PLUMBING NOTES
@ 0.60m B.W INFLUENT LINE
CONCRETE BASE
1. ALL PLUMBING WORKS SHOULD BE DONE IN ACCORDANCE WITH THE
10mm BASE BARS NATIONAL BUILDING CODE AND NATIONAL PLUMBING CODE.
@ 0.20m O.C B.W
2. PIPES SHALL BE INSTALLED AS LOCATED IN THE WORKING DRAWINGS.
ANY RELOCATION REQUIRED FOR PROPER EXECUTION OF OTHER
SECTION (3) PVC ELBOW
&
TRADES SHALL BE UPON ARRIVAL OF SANITARY ENGINEER OR MASTER
FABRICATED PLUMBER.
P-TRAP
3. GALVANIZED IRON DIRECTLY IN CONTACT WITH THE SOIL SHALL BE
APPLIED WITH 2 COATS OF BLACK COALTAR OR EQUIVALENT.
SEPTIC TANK DETAILS
SCALE: NTS FLOOR DRAIN DETAILS 4. ALL DOWNSPOUT SHALL BE 3" Ø (75 MM ) PVC PIPE.
SCALE: NTS
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR HAVING
ASCERTAINED PERTINENT INQUIRIES SUCH AS LOCATION, ACCESSIBILITY,
GENERAL CHARACTER FOR THE EXTENT OF EXISTING AND PROPOSAL
WORK TO BE DONE OR PERFORMED BEFORE THE TIME OF SUBMISSION OF
CONTRACT.
0.60
10mm Ø GRAB BAR
OUTLET 0.40
4" THICK CHB STAINLESS CLEAN OUT
6. ALL SEWER LINE SHALL BE POLYVINYL CHLORIDE PIPE.
6" Ø PVC PIPE OUTLET (COUNTER SINK)
6" Ø PVC PIPE
INLET 7. ALL SLOPES FOR HORIZONTAL DRAINAGE SHALL MAINTAIN 1% MINIMUM
INLET
UNLESS OTHERWISE SPECIFIED.
WATER PROOFING
MEMBRANE 8. USE MATERIALS INDICATED IN WATER AND SANITARY LINE LAYOUT.
10mm Ø GRAB BAR
90' ELBOW 9. 8" Ø CONCRETE PIPE FOR CATCH BASIN OUTLET.
10. 3" Ø PVC PIPE FOR CATCH BASIN INLET.
CATCH BASIN DETAILS 11. 4" Ø PVC PIPE FOR SEPTIC TANK INLET.
SCALE: NTS
FLOOR CLEAN-OUT DETAILS
SCALE: NTS PLUMBING NOTES AND LEGENDS
SCALE: NTS
CIVIL ENGINEER: DESIGNED AND CADD BY: REVISIONS: DATE: PROJECT TITLE: OWNER: SHEET CONTENTS: SHEET NO:
ANDREI JHON D. SOBREPEÑA PROPOSED 4-BEDROOM BUNGALOW SEPTIC TANK DETAILS
ENGR. RITCHIE C. MALASAN CATCH BASIN DETAILS
CHECKED BY:
PROJECT LOCATION:

(AT = 160 m2)


ADDRESS:
FLOOR CLEAN OUT DETAILS
FLOOR DRAIN DETAILS
P-2
ENGR. RITCHIE C. MALASAN SAN MIGUEL, NATIVIDAD, PANGASINAN
9 9
PRC REG NO: PTR NO: PLUMBING LEGENDS
VALIDITY: DATE ISSUED: DATE: SAN MIGUEL, NATIVIDAD, PANGASINAN DATE APPROVED: PLUMBING NOTES
TIN: PLACE ISSUED:
MAY 10, 2024 MAY 10, 2024
16000 16000
4400 1950 2650 3000 4400 1950 2650 3000
2000 1200 2750 450 1900 1200 3000 1500 2000 2000 1200 2750 450 1900 1200 3000 1500 2000
WF WF WF WF C1-F11000 RB
C1-F1 RB 1000
RB
C1-F1 WF C1-F1 C1-F1 C1-F1 C1-F1 RB RB

1500
1500

RB RB
WF TB TB
ELEV. @ +0.95 M ELEV. @ +1 M TB RB RB RB

2000

3000
RB
2000

3000

SLAB ON COMPACTED FILL


WF
SLAB ON COMPACTED FILL
WF ELEV. @ +1 M
SLAB ON COMPACTED FILL
WF
ELEV. @ +1 M 100 mm SLAB ON FILL RB
WF SLAB ON COMPACTED FILL RB RB

1500
w/ 10 mm REBARS SPACED
C1-F1 C1-F1 RB
1500

@ 600mm BOTHWAYS
TB RB RB

500
C1-F1 C1-F1 C1-F1
500

C1-F1 C1-F1 RB
TB
ELEV. @ +1 M
SLAB ON COMPACTED FILL
TB ELEV. @ +0.95 M
SLAB ON COMPACTED FILL
RB RB

2000
ELEV. @ +1 M
RB
2000

WF
ELEV. @ +1 M
TB SLAB ON COMPACTED FILL
TB TB TB RB RB RB RB RB
TB WF

2500
SLAB ON COMPACTED FILL
2500

RB

9500
TB
9500

C1-F1 C1-F1
C1-F1 TB C1-F1 ELEV. @ +1 M RB RB RB RB RB
SLAB ON COMPACTED FILL
WF
C1-F1 C1-F1
ELEV. @ +0.95 M RB

1500
1500

WF TB
SLAB ON COMPACTED FILL C1-F1 C1-F1 RB
C1-F1 C1-F1 C1-F1 RB RB
WF
RB

5000
TB TB 100 mm SLAB ON FILL
5000

w/ 10 mm REBARS SPACED
ELEV. @ +1 M ELEV. @ +0.95 M @ 600mm BOTHWAYS
SLAB ON COMPACTED FILL SLAB ON COMPACTED FILL
ELEV. @ +1 M
ELEV. @ +0.95 M
SLAB ON COMPACTED FILL SLAB ON COMPACTED FILL WF WF

3000
3000

WF RB RB RB RB RB
WF TB
ELEV. @ +0.50 M
C1-F1 C1-F1
SLAB ON COMPACTED FILL
RB RB RB
C1-F1 C1-F1 C1-F1 C1-F1 RB RB
WF WF WF
2000 4000 3500 3000 3500 2000 4000 3500 3000 3500
FOUNDATION PLAN ROOF BEAM PLAN
SCALE: 1:150 SCALE: 1:150
4" THK. CONC. SLAB W/
CONCRETE COL. 9 & 10mm Ø (ALT) 5" CHB
SEE COL. TEMP. BARS @ 600 mm
DETAILS FFL O.C. B.W. 200 200
100 MM GRAVEL BED NGL
FIN GRND LINE
VARIES

FILL FILL 300 2-16 MM BARS 2-16 MM BARS


10mmØ Vertical Bar 300
NAT GRND LINE @0.60m O.C 2-16 MM BARS
2-16 MM BARS
10mmØ Hor'l Bar @ MID SUPPORT CROSS SECTION END SUPPORT CROSS SECTION
1.50 MIN (VARIES)

@0.60m O.C

400
10 MM STIRRUP BAR SPACE
75 MM THK COMPACTED L/4=0.43
L/4 = 0.42 AT 3-.05, 3-.10, 3-.15, REST AT 0.20 MOC
BASE COURSE (34 Ø - 1 21
Ø GRAVEL BED)
10mmØ Tie Bar
STD 90° HOOK @0.20m O.C
.075 0.25 M

GUAGE .40
MM STEEL
TEGULA

200
GRAVEL BED COMPACTED SUBGRADE
OR NATURAL GROUND 3 - 12 mmØ RSB
SEE SCH
SPAN (AS INDICATED)
300
TYP. COLUMN FTG. DETAILS TYP. WALL FTG. DETAILS TYP. BEAM DETAILS
SCALE: NTS SCALE: NTS SCALE: NTS
CIVIL ENGINEER: DESIGNED AND CADD BY: REVISIONS: DATE: PROJECT TITLE: OWNER: SHEET CONTENTS: SHEET NO:
ANDREI JHON D. SOBREPEÑA PROPOSED 4-BEDROOM BUNGALOW FOUNDATION PLAN
ENGR. RITCHIE C. MALASAN
(AT = 160 m2)
CHECKED BY:
PROJECT LOCATION: ADDRESS:
ROOF BEAM PLAN
TYPICAL COLUMN FTG. DETAILS S-1
ENGR. RITCHIE C. MALASAN SAN MIGUEL, NATIVIDAD, PANGASINAN TYPICAL WALL FTG. DETAILS
4 9
PRC REG NO: PTR NO:
VALIDITY: SAN MIGUEL, NATIVIDAD, PANGASINAN TYPICAL BEAM DETAILS
DATE ISSUED: DATE: DATE APPROVED:
TIN: PLACE ISSUED:
MAY 10, 2024 MAY 10, 2024 SLAB DETAILS
`50x100x1.2MM
C-PURLINS
FULL 5
WELD
2-65 X 50 X
6mm TOP 2-65 X 50 X
CHORD
FULL
6mm TOP
CHORD
HT-1 HT-2 HT-3
5
50x50x6MM x WELD 5
5 FULL
75MM ANGLE
WELD
BAR CLEATS
6mm THICK
GUSSET
PLATE
2389

2389
2-50 X 50 X 6mm

845
DIAGONAL/VERTICAL
2389

WEB MEMBERS
1000 1075 1076
1000 880 884 884 884 884 884 884 884 884 884 884 880 1000
1000 880 884 884 884 884 884 1415 936 937 937 937 937 937 937 937
2-50 X 50 X
6mm FULL 2-50 X 50 X 6mm
5
DIAGONAL/VERTICAL WELD DIAGONAL/VERTICAL
WEB 2-50 X 50 X WEB MEMBERS
5
MEMBERS FULL 5 6mm KING
WELD POST
6mm
TRUSS DIAGRAM
5 THICK SCALE: 1:150
FULL 5 GUSSET
WELD
6mm THICK PLATE
GUSSET
PLATE 2-65 X 50 X 6mm
BOTTOM CHORD
2-65 X 50 X
6mm BOTTOM
CHORD T-1 BOTTOM
FULL CHORD
FULL
WELD 5 4-12mmØ X250mm
WELD 5 250 X 200 X
LONG ANCHOR 10mm THICK
BOLT BASE PLATE
TYP. STEEL TRUSS DETAILS 4-12mmØ X300mm
SCALE: 1:150 LONG ANCHOR BOLT SUPPORT
250 X 200 X 10mm BEAM/COLUMN
THICK BASE
PLATE
1366 1366 1366 1366 1366 1366 1366 1366 BOTTOM
CHORD
TYP. TRUSS SUPPORT
SCALE: NTS
C-PURLINS SPACING @500MM
HT3
HT3
HT2
MARK B-1 RB MARK C1 FOOTING SCHEDULE
DIMENSIONS REINFORCEMENTS
T1 T1 T1 T1 2-16mmØ
MARK WIDTH LENGTH THICK. DEPTH BOTTOM BARS TOP BARS
SECTION (X) (Y) (T) (D) X Y X Y
HT1 T1 T1 T1 T1 T1 SECTION 2-16mmØ
F1 1000 1000 250 1000 6-16 MM Ø 6-16 MM Ø - -
4-16 MM BARS 4-16 MM BARS SIZE 300mm x 300mm
4-16 MM BARS 4-16 MM BARS MAINBARS 4-16 mmØ
LT STANDARD 10mmØ
SIZE 200mm x 300mm 200mm x 300mm
SPACING
3-50, 3-100, 3-150mm
REST @200mm
HT2
HT3 STIRRUPS STANDARD 10mmØ STANDARD 10mmØ
HT3
SCHEDULE OF BEAMS SCHEDULE OF COLUMNS SCHEDULE OF FOOTING
SCALE: NTS SCALE: NTS SCALE: NTS
ROOF FRAMING PLAN
SCALE: 1:150
CIVIL ENGINEER: DESIGNED AND CADD BY: REVISIONS: DATE: PROJECT TITLE: OWNER: SHEET CONTENTS: SHEET NO:
ANDREI JHON D. SOBREPEÑA PROPOSED 4-BEDROOM BUNGALOW TRUSS DIAGRAM
ENGR. RITCHIE C. MALASAN
(AT = 160 m2)
S-2
ROOF FRAMING PLAN
CHECKED BY: SCHEDULE OF REINFORCEMENT BEAM
PROJECT LOCATION: ADDRESS:
ENGR. RITCHIE C. MALASAN SAN MIGUEL, NATIVIDAD, PANGASINAN SCHEDULE OF COLUMN
5 9
PRC REG NO: PTR NO:
SCHEDULE OF FOOTING
VALIDITY: DATE ISSUED: DATE: SAN MIGUEL, NATIVIDAD, PANGASINAN DATE APPROVED:
TIN: PLACE ISSUED:
MAY 10, 2024 MAY 10, 2024 TYPICAL STEEL TRUSS DETAILS