0% found this document useful (0 votes)
26 views2 pages

LED Check On PWR Board

This document describes the LED indicators on the power boards of a radar system. It provides the part numbers, normal statuses, and functions of LEDs that indicate overcurrent, under/over voltage conditions. Restarting power resets the LED indicators. The location of the LEDs on the power boards is also shown in a figure.

Uploaded by

pronav2024
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
26 views2 pages

LED Check On PWR Board

This document describes the LED indicators on the power boards of a radar system. It provides the part numbers, normal statuses, and functions of LEDs that indicate overcurrent, under/over voltage conditions. Restarting power resets the LED indicators. The location of the LEDs on the power boards is also shown in a figure.

Uploaded by

pronav2024
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

6.

3 LED Check

3. PWR board
Table 6.3.3 LEDs on PWR board

Part Normal
Board Function
number status
Lights on when the over-current of antenna motor power
supply (+24 VDC) is detected. Restart the power to reset.
CR63
OFF Note:
(MTR)
Since the antenna motor of S-band radar is of AC motor
type, +24 VDC antenna motor power supply is not used.
Lights on when 4 to 5A, over-current of power supply for
CR64 (RF) OFF
TR unit (+24 VDC), is detected. Restart the power to reset.
Lights on when 5 to 7A, over-current of Tx-HV power
PWR (AC) CR65 supply (+24 VDC), is detected. Restart the power to reset.
OFF
(03P9339) (Tx-HV) The TX-HV board also has an over-current protection
circuit.
and The LED is turned on when input over/low voltage is
detected. Operation is restarted when the voltage comes
PWR (DC) back to the specified voltage range.
(03P9338)
AC type
Protection DC type
100 VAC 220 VAC
CR23
OFF Over 141 to 282 to 34 to
(IN ER)
voltage 147 VAC 294 VAC 38 VDC
148 to - 24 VDC Spc.
Low 70 to 170 VAC 13 to 17 VDC
voltage 80 VAC - 12 VDC Spc.
7.3 to 8.5 VDC

6-25
6.3 LED Check

CR63 (MTR)
CR63 (MTR)
CR64 (RF)
CR64 (RF)
CR65 (Tx-HV)
CR65 (Tx-HV)

CR23 (IN ER)


CR23 (IN ER)

PWR board DC (03P9338) PWR board AC (03P9339)

Fig. 6.3.4 Location of LEDs on PWR Board

6-26

You might also like