PROJECT TITLE:

2244 Jafurah Modules

MAIN CONTRACTOR

Samsung Engineering Co. Limited (SECL)

DISCRIPTION:
Design calculations for Pipe stand 4T Capacity

A 27-Sept-23 ISSUE FOR REVIEW FIRST ISSUE FOR REVIEW

REV. DATE PRPD APPVD PURPOSE OF ISSUE DESCRIPTION

DOCUMENT NO.
ARABIAN INTERNATIONAL
COMPANY 2211
P.O. BOX: 41017, JEDDAH 21521 K.S. A
Tel: 5910999, Fax: 5910099
REV. -A-
Table of Contents
1. Introduction .................................................................................................................................... 1
1.1. Scope of work.............................................................................................................................. 2
2. References ...................................................................................................................................... 2
Standards and Codes .......................................................................................................................... 2
3. Software Used ................................................................................................................................. 2
4. Materials ......................................................................................................................................... 2
5. Design Loads ................................................................................................................................... 3
5.1. Dead Loads: ................................................................................................................................. 3
5.2. Live Load: .................................................................................................................................... 3
5.3. Wind Load ................................................................................................................................... 5
6. Load Combinations ......................................................................................................................... 7
7. The Result........................................................................................................................................ 8
7.1. Straining action diagrams ........................................................................................................... 8
7.2. Stress and deflection check ...................................................................................................... 11
8. Design Drawings............................................................................................................................ 13

1
1. Introduction
This report studies the analysis and design verification for Pipe support of capacity 4 T. The Pipe
stand consists of UB203x102x23 beams, colums and base support and L90x90x9 ties.

Figure 1 Structural walkway geometry

Figure 2 Sections assignment

1
1.1. Scope of work
The current scope of work is to design Pipe support members

2. References
Standards and Codes
• AISC 360-10-Specification for Structural Steel Buildings- (ASD)
• ASCE 7-10: Minimum Design Loads for Building and Other Structures

3. Software Used
The structure has been modeled with a finite element analysis three-dimensional model on SAP2000.

4. Materials

MINIMUM YIELD MINIMUM TENSILE


PURPOSE MATERIAL STRESS STRENGTH
(MPA) (MPA)

All UB203x102x23 and


angles A36 250 400
And Plates
5. Design Loads
− Dead Load
− Live Load
− Wind Load

5.1. Dead Loads:


− Own weight of the structure is applied automatically to the FEM models by the program.
Considering self-weight of sections of elements.

5.2. Live Load:


− Weight of Pipe that will be supported = 40kN (Point Load). Taken at 3 different position along the
beam length, with 1.7 Factor of Safety.

Figure 3 Pipe Load Case (1) (LL1)

3
Figure 4 Pipe Load Case (2) (LL2)

Figure 5 Pipe Load Case (3) (LL3)


5.3. Wind Load
− Wind Load is assigned on the structure members as open structure

Figure 6 Wind Load open structure (X-direction)

5
Figure 7 Wind Load open structure (Y-direction)
6. Load Combinations
Load Combinations taken as follow:
• DL : Own weight of structure
• LL: Live Load on beam
• Wx: Wind as open-structure (X-direction)
• Wy: Wind as open-structure (Y-direction)

SLS:
• DL+1.7LL1
• DL+1.7LL2
• DL+1.7LL1+Wx
• DL+1.7LL2+Wx
• DL+1.7LL3+Wx
• DL+1.7LL1+Wy
• DL+1.7LL2+Wy
• DL+1.7LL3+Wy
• 0.6DL+Wx
• 0.6DL+Wy

7
7. The Result
7.1. Straining action diagrams

• Normal Force diagram

Figure 8 Normal Force Diagram (kN)


• Shear Force diagram

Figure 11 Shear Force Diagram (kN)

9
• Bending Moment Diagram

Figure 12 Bending Moment Diagram (kN.m)


7.2. Stress and deflection check

• Design utilization ratio.

Figure 15 Design Validation

11
• Deflection check.
− Maximum deflection due to DL+1.7LL2= 1.1mm < Allowable =L/240=1675/240=7mm

Figure 16 Beam deflection


8. Design Drawings

13
Frame Capacity is 4 Ton
General Notes:

1-Frame capacity is 4 Ton.

2-Minimum steel grade S275JR for all members .

3-All plates grade are A36.

4-Minimum weld is 7mm Fillet weld

5-Total QTY is 10 frames.