2244-Pipe Lifting Stand
2244-Pipe Lifting Stand
2244-Pipe Lifting Stand
MAIN CONTRACTOR
DISCRIPTION:
Design calculations for Pipe stand 4T Capacity
DOCUMENT NO.
ARABIAN INTERNATIONAL
COMPANY 2211
P.O. BOX: 41017, JEDDAH 21521 K.S. A
Tel: 5910999, Fax: 5910099
REV. -A-
Table of Contents
1. Introduction .................................................................................................................................... 1
1.1. Scope of work.............................................................................................................................. 2
2. References ...................................................................................................................................... 2
Standards and Codes .......................................................................................................................... 2
3. Software Used ................................................................................................................................. 2
4. Materials ......................................................................................................................................... 2
5. Design Loads ................................................................................................................................... 3
5.1. Dead Loads: ................................................................................................................................. 3
5.2. Live Load: .................................................................................................................................... 3
5.3. Wind Load ................................................................................................................................... 5
6. Load Combinations ......................................................................................................................... 7
7. The Result........................................................................................................................................ 8
7.1. Straining action diagrams ........................................................................................................... 8
7.2. Stress and deflection check ...................................................................................................... 11
8. Design Drawings............................................................................................................................ 13
1
1. Introduction
This report studies the analysis and design verification for Pipe support of capacity 4 T. The Pipe
stand consists of UB203x102x23 beams, colums and base support and L90x90x9 ties.
1
1.1. Scope of work
The current scope of work is to design Pipe support members
2. References
Standards and Codes
• AISC 360-10-Specification for Structural Steel Buildings- (ASD)
• ASCE 7-10: Minimum Design Loads for Building and Other Structures
3. Software Used
The structure has been modeled with a finite element analysis three-dimensional model on SAP2000.
4. Materials
3
Figure 4 Pipe Load Case (2) (LL2)
5
Figure 7 Wind Load open structure (Y-direction)
6. Load Combinations
Load Combinations taken as follow:
• DL : Own weight of structure
• LL: Live Load on beam
• Wx: Wind as open-structure (X-direction)
• Wy: Wind as open-structure (Y-direction)
SLS:
• DL+1.7LL1
• DL+1.7LL2
• DL+1.7LL1+Wx
• DL+1.7LL2+Wx
• DL+1.7LL3+Wx
• DL+1.7LL1+Wy
• DL+1.7LL2+Wy
• DL+1.7LL3+Wy
• 0.6DL+Wx
• 0.6DL+Wy
7
7. The Result
7.1. Straining action diagrams
9
• Bending Moment Diagram
11
• Deflection check.
− Maximum deflection due to DL+1.7LL2= 1.1mm < Allowable =L/240=1675/240=7mm
13
Frame Capacity is 4 Ton
General Notes: