Model Questions of DSE4T For ESE
Model Questions of DSE4T For ESE
25. Write down two methods for measurement of linear displacement using capacitive
transducer.
26. Define temperature coefficient of resistivity of a thermistor. Give two examples of PTC
an NTC thermistors. Write down resistance -temperature relation of NTC thermistors.
27. A copper-constantan thermocouple was found to have linear calibration between 0oC and
400 oC with emf at maximum temperature (w.r.t to cold junction 0oC) equal to 20 mV.
(a) Determine the correction which must be made to the indicated emf if the cold
junction temperature is 20oC.
(b) If the indicated emf is 8.90 mV (w.r.t cold junction temperature at 20oC) in the
thermocouple circuit, determine the temperature of the hot junction.
28. What are the different Factors to be considered while selecting transducer?