38DL PLUS™ Ultrasonic Thickness Gauge


Advanced Features, Simple Operation
Advanced Features, Simple Operation, Rugged, and Reliable

The 38DL PLUS™ ultrasonic thickness gauge combines ease Key Features
of use and accuracy with a durable design. Ideally suited ❯ Dual and single element transducer compatibility
for almost every ultrasonic thickness gauging application, ❯ Wide thickness range: 0.08 mm (0.003 in.) to 635 mm
this versatile handheld gauge is compatible with a full line (25 in.) depending on material and transducer selection
❯ Corrosion thickness gauging with dual element transducers
of dual and single element transducers. You can use it in ❯ THRU-COAT™ technology and echo-to-echo measurements on painted
applications ranging from wall thinning measurements and coated surfaces
of internally corroded pipes with dual element probes to ❯ Internal Oxide/Scale software option
very precise thickness measurements of thin or multilayer ❯ Standard resolution of 0.01 mm or 0.001 in. for all transducers
❯ High Resolution software option of 0.001 mm or 0.0001 in. with single
materials with single element transducers. element transducers from 2.25 MHz to 30 MHz
❯ Multilayer software option for measurements of up to four layers
The 38DL PLUS gauge comes standard with powerful simultaneously
measurement features and a range of application-specific ❯ High Penetration software option for attenuating materials such as
software options. Its sealed case is designed for IP67 to fiberglass, rubber, and thick castings
❯ Thickness, velocity, and time-of-flight measurements
withstand the rigors of very wet or dusty environments.
❯ Differential mode and reduction rate mode
The color transflective VGA display provides excellent ❯ Time-based B-scan mode; 10,000 reviewable readings per scan
readability from bright sunlight to complete darkness. It ❯ High Dynamic Gain technology with digital filters
features a simple, ergonomic keypad that you can operate ❯ V-Path Builder for custom V-path compensation
❯ Designed for EN15317
with the left or right hand for easy access to all functions.

Ultrasonic thickness measurements are accurate, reliable, and repeatable. Instant readings can be achieved from one side of a material, making it unnecessary to cut up or destroy the part.

2
What Makes This Thickness Gauge Different from Others?
The 38DL PLUS™ thickness gauge is built to meet the
challenges of demanding applications and withstand
tough conditions in the field and on the production floor.
Whether you work in wet or dusty conditions, cold or hot
climates, or bright or dark areas, the 38DL PLUS gauge
can handle any inspection job. Need an instrument tough
enough to tolerate shocks, drops, and rough handling?
The 38DL PLUS gauge, with its protective rubber boot and
military-rugged design, is your answer.

Built for Tough Environments


❯ Compact, weighs only 0.814 kg (1.80 lb)
❯ Rugged, designed for IP67
❯ Explosive atmosphere: tested using MIL-STD-810F,
Method 511.4, Procedure I
❯ Shock tested using MIL-STD-810F, Method 516.5, Procedure I,
6 cycles each axis, 15 g, 11 msec half sine
❯ Vibration tested using MIL-STD-810F, Method 514.5, Procedure I,
Annex C, Figure 6, general exposure: 1 hour each axis
❯ Wide operating temperature range
❯ Protective rubber boot with gauge stand
❯ Color transflective VGA display with indoor and outdoor color settings
for excellent clarity

Designed for Easy Operation


❯ Simple keypad for right hand/left hand operation
❯ Easy operator interface with direct access to all functions
❯ Internal and external microSD™ memory card storage
❯ USB and RS-232 communication ports
❯ Alphanumeric data logger with 475,000 thickness readings
or 20,000 waveforms
❯ VGA output to connect to computer or monitor
❯ Default/Custom dual element transducer setups
❯ Default/Custom single element transducer setups
❯ Password protected function enables locking of instrument features

Outdoor display setting, A-scan mode

Indoor display setting, B-scan mode


38DL PLUS thickness gauge with standard protective rubber boot

3
Thickness Measurements on Internally Corroded Metals
One of the major applications of the 38DL PLUS™ gauge is
measuring the remaining thickness of pipes, tubes, tanks,
pressure vessels, hulls, and other structures affected by
corrosion or erosion. Dual element transducers are most
commonly used for these applications.
❯ Automatic Probe Recognition for standard D79X series dual
element transducers
❯ Ten custom dual element transducer setups
❯ Optimized default gain during calibration for dual element transducer
❯ V-Path Builder for custom V-path compensation
❯ Calibration doubling warning when echo doubling may occur
during calibration
❯ THRU-COAT™ technology and echo-to-echo measurements on painted
and coated surfaces
❯ High-temperature measurements; up to 500 °C (932 °F)
❯ Boiler tube and internal oxide measurements (optional) with M2017
or M2091 single element transducers
❯ EMAT transducer (E110-SB) for no-couplant measurements
of boiler tubes with external oxide/scale buildup

Encoded B-scan Option THRU-COAT Technology


This powerful optional feature This feature uses a single
enables the 38DL PLUS back-wall echo to measure
gauge to be connected to a true metal thickness. You can
linear encoded scanner to display the metal and coating
generate encoded B-scans. thicknesses, each adjusted for
The instrument will capture their correct material sound
and store the distance velocities. There is no need
traveled information along to remove paint and coatings
with corresponding thickness from surfaces. THRU-COAT
readings. The waveform at the measurements use the D7906-
minimum thickness location SM, D7906-RM, and D7908 dual
is also captured. The user can element transducers.
select the distance between
measurements and select
between bidirectional and
unidirectional modes. Up to
10,000 thickness readings can
be stored in a single B-scan.

4
Temperature Compensation Oxide/Scale Measurement Option
Variations in material This feature uses advanced
temperature affect sound algorithms to measure the
velocity and the accuracy of thickness of oxide/scale
thickness measurements. The buildups inside boiler tubes.
temperature compensation The gauge simultaneously
feature enables you to displays the metal thickness
manually enter the calibration of the boiler tube and the
block’s temperature and the thickness of the oxide layer.
current (high) temperature Knowing the thickness of the
at the measurement points. oxide/scale helps predict tube
The The 38DL PLUS™ life. We recommend using
gauge automatically M2017 or M2091 transducers in
displays the temperature- this application.
corrected thickness.

V-Path Builder
This patented feature enables you to build a custom
V-path compensation curve for almost any dual element
transducer. These curves can be saved and recalled along
with custom setups for most dual element transducers.
You simply calibrate and enter the known thickness with
a minimum of 3 and up to 10 calibration points, and the
instrument will create the V-path.

Automatic Probe Recognition


All standard dual element transducers (see chart
below) feature Automatic Probe Recognition, which
automatically recalls a default V-path correction for each
specific transducer.

5
Dual Element Transducers for Corrosion Gauging
All standard dual element transducers feature Automatic Probe Recognition, which automatically recalls a default V-path
correction for each specific transducer.

Item Freq. Tip Dia. Range (Steel)* Temp. Range** Item


Transducer Connector Cable
Number (MHz) mm (in.) mm (in.) °C (°F) Number
D790 U8450002 Straight Potted —
D790-SM U8450009 Straight 11.00 1.00 to 500.00 –20 to 500 LCMD-316-5B† U8800353
5.0
D790-RL U8450007 90° (0.434) (0.040 to 20.000) (–5 to 932) LCLD-316-5G† U8800330
D790-SL U8450008 Straight LCLD-316-5H U8800331
11.00 1.00 to 500.00 –20 to 500
D791 U8450010 5.0 90° Potted —
(0.434) (0.040 to 20.000) (–5 to 932)
11.00 1.00 to 500.00 –20 to 400
D791-RM U8450011 5.0 90° LCMD-316-5C U8800354
(0.434) (0.040 to 20.000) (–5 to 752)
D7912 Q4530005 Straight 7.50 0.50 to 25.00 0 to 50
10.0 Potted —
D7913 Q4530006 90° (0.295) (0.020 to 1.000) (32 to 122)

7.20 0.75 to 50.00 0 to 50


D794 U8450014 5.0 Straight Potted —
(0.283) (0.030 to 2.000) (32 to 122)
D797 U8450016 90° 22.90 3.80 to 635.00 –20 to 400 Potted —
2.0
D797-SM U8450017 Straight (0.900) (0.150 to 25.000) (–5 to 752) LCMD-316-5D U8800355
D7226 U8454013 8.90 0.71 to 100.00 –20 to 150
7.5 90° Potted —
D798-LF U8450019 (0.350) (0.028 to 4.000) (–5 to 300)

D798 U8450018 90° 7.20 0.71 to 100.00 –20 to 150 Potted —


7.5
D798-SM U8450020 Straight (0.283) (0.028 to 4.000) (–5 to 300) LCMD-316-5J U8800357
11.00 1.00 to 500.00 –20 to 150
D799 U8450021 5.0 90° Potted —
(0.434) (0.040 to 20.000) (–5 to 300)
12.7 1.00 to 254 0 to 50
D7910 U8454038 5.0 90° Potted —
(0.500) (0.040 to 10.000) (32 to 122)
5.10 1.00 to 19.00 0 to 50
MTD705†† U8620225 5.0 90° LCLPD-78-5 U8800332
(0.200) (0.040 to 0.750) (32 to 122)
D7906-SM †††
U8450005 Straight 11.00 1.00 to 50.00 0 to 50 LCMD-316-5L U8800358
5.0
D7906-RM††† U8450025 90° (0.434) (0.040 to 2.000) (32 to 122) LCMD-316-5N U8800647
7.20 1.00 to 37.00 0 to 50
D7908 ††
U8450006 7.5 90° Potted —
(0.283) (0.040 to 1.500) (32 to 122)

* Thickness range dependent on material, transducer type, surface conditions, †


Stainless steel cable available; consult Olympus for details.
and temperature. Full range may require Gain adjustment. ††
Not certified to EN15317; The MTD705 is issued a TP103 test certificate in accordance
** Maximum temperature with intermittent contact only. with ASTM E1065.
†††
Transducers used with THRU-COAT® technology.

Single Element Transducers for Corrosion Gauging


For a complete list of single element transducers, please consult your local representative or visit us online at
EvidentScientific.com.
Item Freq. Tip Dia. Range (Steel)* Temp. Range** Item
Transducer Connector Cable
Number (MHz) mm (in.) mm (in.) °C (°F) Number
V260-SM U8411019 Straight LCM-74-4 U8800348
2.00 0.50 to 10.00 0 to 50
V260-RM U8411018 15 90° LCM-74-4 U8800348
(0.080) (0.020 to 0.400) (32 to 122)
V260-45 U8411017 45° LCM-74-4 U8800348
Steel 0.50 to 12.00
6.35 (0.020 to 0.500) 0 to 50
M2017 U8415002 20 90° LCM-74-4 U8800348
(0.250) Oxide 0.25 to 1.25 (32 to 122)
(0.010 to 0.050)
Steel 0.50 to 12.00
6.35 (0.020 to 0.500) 0 to 50
M2091 U8415018 20 90° LCM-74-4 U8800348
(0.250) Oxide 0.15 to 1.25 (32 to 122)
(0.006 to 0.050)
28.50 2.00 to 125.00 0 to 80 LCB-74-4 and U8800320
E110-SB U8471001 — Straight
(1.250) (0.080 to 5.000) (32 to 176) 1/2XA/E110 U8767104

* Dependent on material, transducer type, surface conditions, and temperature. Full range may require Gain Adjust.
** Maximum temperature with intermittent contact only.

6
D791

D794
D7908

D7226

D790

D790-RL

D798-LF

D790-SL

D791-RM D799

MTD705

D790-SM
D798

D7906-SM

D7910
D797-SM

D7913
D7912

M2017 M2091 E110-SB

Additional Products
Couplants Calibration Test Blocks Transducer Cables
Liquid couplant is almost always Test blocks are necessary for the A wide selection of transducer cables
necessary to provide acoustic calibration of ultrasonic thickness suitable for all ultrasonic thickness
coupling between the transducer gauges and should be used to gauging instrumentation.
and the test piece. We offer various maintain and verify the accuracy,
❯ Standard
types of couplants to suit virtually dependability, and reliability of ❯ Waterproof
all applications. ultrasonic measurements. Blocks are ❯ Heavy duty
held to tighter tolerances than stated - Teflon
in the ASTM E797 code. Metric test - Stainless steel
blocks are available.

7
Thickness Measurements on Plastics, Metals,
Composites, Glass, Rubber, and Ceramics
When using single element transducers, you can make
accurate thickness measurements on metals, plastics,
composites, glass, ceramics, and other materials. These
transducers are available in a wide range of frequencies,
diameters, and connector styles. The High Resolution
software option enables you to make very precise
measurements at a resolution of 0.0001 in. or 0.001 mm.
❯ Standard resolution of 0.01 mm (0.001 in.) for all transducers
❯ High Resolution software option can display measurements up
to 0.001 mm (0.0001 in.) for single element transducers from
2.25 MHz to 30 MHz
❯ High Penetration software option for measurements on attenuating
materials such as fiberglass, rubber, and thick castings
❯ Multilayer software option for individual thickness measurements of
up to four layers simultaneously
❯ Thickness, velocity, or time-of-flight measurements
❯ Application auto-recall with default and custom setups to simplify
thickness measurements
Measure the thickness of many materials including plastic, metal, rubber, glass, ceramic,
and composites.
High Penetration Software Option
This option enables you to use low frequency single
element transducers (as low as 0.5 MHz) to measure thick
or sound attenuating materials such as rubber, fiberglass,
castings, and composites.

Multilayer Software Option


This software option calculates and simultaneously
displays thickness measurements of up to four individual
layers. It also displays the total thickness of selected
layers. Typical applications include thickness of barrier
layers in plastic fuel tanks, bottle preforms, and soft
contact lenses.

Outer Inside
Surface Surface

Many cast metal parts or sound-attenuating materials can be measured with the High Penetration
software option.

HDPE EVOH HDPE Total


Layer Barrier Layer Thickness
0.1658 in. 0.0044 in. 0.0781 in. 0.2483 in.

The 38DL PLUS thickness gauge can make accurate measurements of up to four individual layers The High Resolution software option enables thickness measurements of up to
simultaneously. 0.001 mm (0.0001 in.) resolution.

8
Data Logger and PC Interface
The 38DL PLUS™ gauge has a full-featured internal, microSD Card
bidirectional alphanumeric data logger that is designed VGA Connectors
USB Connector
to easily collect and transfer thickness readings and
USB or RS-232
waveform data.
Charger Probe Connectors
❯ Internal memory of 475,000 thickness readings or 20,000 waveforms
with thickness readings
❯ 32-character file name
❯ 20-character ID# (TML#)
❯ 9 file formats:
Incremental, sequential, sequential with custom point, 2D grid, 2D
grid with custom point, 3D grid, 3D custom, boiler, and manual
❯ Stores up to 4 comments (notes) per ID# (TML)
❯ Stores comments (notes) at an ID# or to a range of ID#s
❯ Internal and external microSD memory cards
❯ File copy with the ability to copy files between internal/external
microSD™ memory cards
❯ Standard USB and RS-232 communication
❯ Two-way transfer of both single and dual element transducer setups
❯ Onboard statistical report
❯ Onboard DB Grid View with three programmable colors
❯ GageView™ interface program can communicate with the 38DL PLUS
instrument using the USB, RS-232 ports, and can read and write to a
microSD memory card
❯ Direct export of internal files to microSD memory card in an Excel
compatible CSV (comma-separated values) format Onboard DB Grid View with three programmable colors

38-Link™ Wireless Communication Adapter GageView™ Program


The optional 38-Link wireless adapter enables any ❯ The GageView interface program, a Windows-based application,
collects, creates, prints, and manages data from the
existing 38DL PLUS gauge to send and receive data using 38DL PLUS gauge
Bluetooth® or wireless LAN.* ❯ Create datasets and surveys
❯ Stored data editing
The 38-Link adapter provides three powerful wireless ❯ View dataset and survey files including thickness readings, gauge
communication capabilities: setup values, and transducer setup values
❯ Download and upload thickness surveys to and from the gauges
❯ Wireless communication to the Olympus Scientific Cloud (OSC) ❯ Export surveys to spreadsheets and other programs
❯ Bluetooth communication to the Link Plus app or other compatible ❯ Collect snapshot screens
third-party applications ❯ Print reports such as thickness, setup table, statistics, and color grid
❯ Bluetooth communication to the optional Link-Wedge software to ❯ Upgrade the operating software
directly send thickness readings into an active program on your ❯ Download and upload single and dual element transducer setup files
Windows 7 or Windows 10 PC ❯ B-scan review

For more details, see the 38-Link brochure or visit us


online at EvidentScientific.com.

9
Single Element Transducers for
Precision Thickness Measurements
Contact Transducers
Element
Frequency Diameter Item
Transducer M102-SB M1036
(MHz) Number
mm inches
0.5 25 1.00 M101-SB* U8400017
1.0 25 1.00 M102-SB* U8400018
1.0 13 0.50 M103-SB* U8400020
2.25 13 0.50 M106-RM U8400023
M106-SM U8400025
2.25 13 0.50 M1036 U8400019
5.0 13 0.50 M109-RM U8400027
M109-SM U8400028 M101-SB
M103-SB
5.0 6 0.25 M110-RM U8400030
M110-SM U8400031
M110H-RM** U8400029
M106-SM
10 6 0.25 M112-RM U8400034 M109-SM
M112-SM U8400035 M112-SM M110-RM
M112H-RM** U8400033
10 3 0.125 M1016 U8400015
20 3 0.125 M116-RM U8400038
M116-SM U8400039
M106-RM M116-SM
20 3 0.125 M116H-RM** U8400037
M116-RM M112-RM
M109-RM
* These transducers can only be used with the High Penetration software option. M1061
** Use with spring loaded holder.

Sonopen™ Transducers
The Sonopen transducer
has a replaceable delay
line that is tapered to a
small contact area. This V260-45 V260-SM V260-RM
transducer makes reliable DLP-301

thickness measurements in Sonopen – 15 MHz, 3 mm (0.125 IN.) transducer Sonopen – Replaceable Delay Lines
applications such as turbine Straight Handle Right Angle Handle 45° Handle Tip Diameter Item
Part
blades and tight radii on Item Item Item mm inches Number
Part Part Part
plastic containers. Number Number Number
2.0 0.080 DLP-3 U8770086
V260-SM U8411019 V260-RM U8411018 V260-45 U8411017
1.5 0.060 DLP-302 U8770088
2.0 0.080 DLP-301† U8770087
† High-temperature delay for use up to 175 °C (350 °F)

Immersion Transducers Frequency


Element Diameter
Transducer
Item
(MHz) Number
mm inches
Microscan immersion transducers are designed to

2.25 13 0.50 M306-SU U8410027
transmit and receive ultrasound in water. Thickness
measurements by immersion technique are often 5.0 13 0.50 M309-SU U8420001

preferred when the test piece has a complex geometry 5.0 6 0.25 M310-SU U8420004

or in on-line applications. Typical off-line applications 10 6 0.25 M312-SU U8420008

include wall thickness measurements on small-diameter 15 6 0.25 M313-SU U8420009

plastic or metal tubing, scanned or rotary measurements, 20 3 0.125 M316-SU U8420011

and thickness measurements on sharply curved parts.


Transducer focusing may be necessary depending on
the application.

RBS-1 Immersion Tank


The RBS-1 immersion tank is designed to simplify
ultrasonic thickness measurements using
immersion techniques.

10
Delay Line Transducers
Microscan™ delay line transducers provide excellent performance on very thin materials, at elevated temperatures,
or with applications that require a high degree of thickness resolution.
Element
Freq. Diameter Item Item
Transducer Holder
(MHz) Number Number
mm inches
0.5 25 1.00 M2008* U8415001 —
2.25 13 0.50 M207-RB U8410017 —
5.0 13 0.50 M206-RB U8410016 —
5.0 6 0.25 M201-RM U8410001 —
5.0 6 0.25 M201H-RM U8411030 2127 U8770408 M2055
M202-RM U8410003
10 6 0.25 —
M202-SM U8410004
10 6 0.25 M202H-RM U8507023 2127 U8770408
M2008
M203-RM U8410006
10 3 0.125 —
M203-SM U8410007 M202
M201
M208-RM U8410019
20 3 0.125 —
M208-SM U8410020
20 3 0.125 M208H-RM U8410018 2133 U8770412 M206-RB 2127
20 3 0.125 M2055** U8415013 —
30 6 0.25 V213-BC-RM** U8411022 — 2133

* These transducers can only be used with the High Penetration software option.
** Delay line is not replaceable on these transducers.
M208H

M208

Replaceable Delay Lines Element


Diameter
Delay Line
Maximum Thickness
Measurement Limit*

Delay lines function as a protective buffer Part


Item Steel - Mode 2 Steel - Mode 3 Plastic - Mode 2
Number
between the surface of the test piece and the mm inches mm inches mm inches mm inches

transducer element. 13 0.50 DLH-2 U8770062 25 1.0 13 0.5 13 0.5


6 0.25 DLH-1 U8770054 25 1.0 13 0.5 13 0.5
3 0.125 DLH-3 U8770069 13 0.5 5 0.2 5 0.2
* Exact range depends on material sound velocity, transducer frequency, part geometry, and surface condition.

11
38DL PLUS™ Specifications*
Measurements
Standard Package
Dual element transducer
Time interval from a precision delay after the excitation pulse to the first echo
measurement mode ❯ 38DL PLUS ultrasonic thickness gauge, AC
THRU-COAT™ measurement Measurement of true metal and coating thicknesses with a single back-wall echo or battery operation, 50 Hz to 60 Hz
(with D7906-SM and D7908 transducers) ❯ Kits available with standard dual
Thru-Paint Echo-to-Echo Time interval between two successive back-wall echoes to eliminate paint or coating thickness element transducers*
Single element transducer Mode 1: Time interval between the excitation pulse and the first back-wall echo
❯ Charger/AC adapter (100 VAC, 115 VAC,
measurement modes Mode 2: Time interval between the delay line echo and the first back-wall echo (with delay or 230 VAC)
immersion transducers) ❯ Internal data logger
Mode 3: Time interval between successive back-wall echoes following the first interface echo
after the excitation pulse (with delay line or immersion transducers)
❯ GageView™ interface program
Oxide: optional ❯ Test block* and couplant
Multilayer mode: optional ❯ USB cable
Thickness range  .080 mm to 635.00 mm (0.003 in. to 25.000 in.) depending on material,
0 ❯ Rubber protective boot with gauge stand
transducer surface conditions, temperature, and selected configuration and neck strap
Material velocity range 0.508 mm/μs to 13.998 mm/μs (0.020 in./μs to 0.551 in./μs) ❯ User’s manual
Resolution (selectable) Low: 0.1 mm (0.01 in.) ❯ Measurement features: THRU-COAT, Thru-
Standard: 0.01 mm (0.001 in.) Paint Echo-to-Echo, EMAT compatibility,
High Resolution (optional): 0.001 mm (0.0001 in.) Min./Max. mode, two alarm modes,
Transducer frequency range
Standard: 2.0 MHz to 30 MHz (–3 dB) differential mode, B-scan, Application
High Penetration (optional): 0.50 MHz to 30 MHz (–3 dB) Auto-Recall, temperature compensation,
Average/Min. mode
General
Operating temperature range –10 °C to 50 °C (14 °F to 122 °F) Software Options
Keypad Sealed, color-coded keypad with tactile and audible feedback 38DLP-OXIDE (U8147014): Code-activated Internal
Case Impact-resistant and water-resistant, gasketed case with sealed connectors; designed for IP67
Oxide measurement software

Dimensions (W x H x D) Overall: 125 mm x 211 mm x 46 mm (4.92 in. x 8.31 in. x 1.82 in.)
38DLP-HR (U8147015): Code-activated High
Resolution measurement software
Weight 0.814 kg (1.80 lb)
38DLP-MM (U8147016): Code-activated Multilayer
Power supply AC/DC adapter, 24 V; lithium-ion battery 23.760 Wh; or 4 AA auxiliary batteries measurement software
Operating time: minimum 12.6 h, 14 h typical, 14.7 h maximum 38DLP-HP (U8147017): Code-activated High
Battery life, lithium-ion
Fast charge: 2 h to 3 h
Penetration (low frequency) measurement software
Standards Designed for EN15317
38DLP-EBSCAN (U8147018): Encoded
Explosive atmosphere Tested using MIL-STD-810G, Method 511.5, Procedure I B-scan software

Optional Accessories
Display
38-LINK-BT-U-EN (Q7790104): 38-Link™ adapter with
Color transflective VGA display Liquid crystal display area: 56.16 mm x 74.88 mm (2.2 in. x 2.95 in.) Bluetooth dongle
Rectification Full wave, RF, half-wave positive, or half-wave negative 38-LINK-WF-NA-EN (Q7790113): 38-Link adapter with
Wireless LAN dongle
Inputs/Outputs 38DLP/EW (U8778348): Three-year warranty
USB 1.0 client 1/2XA/E110 (U8767104): Filter adapter for E110‑SB
RS-232 Yes EMAT transducer

Memory card Maximum capacity: 2 GB external microSD™ memory card 38-9F6 (U8840167): RS-232 cable

Video output VGA output standard 38-C-USB-IP67 (U8800998): USB cable for
IP67 sealed operation

Internal Data logger 38DLP/RFS (U8780288): Foot switch, factory installed


EPLTC-C-VGA-6 (U8840035): VGA output cable
Data logger The 38DL PLUS instrument identifies, stores, recalls, clears, and transmits thickness readings,
waveform images, and gauge configuration information through the standard RS-232 serial MICROSD-ADP-2GB (U8779307):
port or USB port. 2 GB External microSD memory card
Capacity 475,000 thickness measurements or 20,000 waveforms with thickness measurements BSCAN-ENC (U8779522): Encoded B-scan buggy
File names, IDs, and comments 32-character file names and 20-character alphanumeric location codes with four comments 38DLP-ENC-CBC-10 (U8840168): 10 ft
per location
encoder cable
File structures Nine standard or custom application-specific file structures
On-gauge reporting of summary with statistics, Min./Max. with locations, Min. review, file
Reports
comparison, and alarm report
E0440039EN

Evident Scientific, Inc. EVIDENT CORPORATION is certified to ISO 9001, ISO 14001, and OHSAS 18001.
48 Woerd Avenue All specifications are subject to change without notice.
Waltham, MA 02453, USA All brands are trademarks or registered trademarks of their respective owners and third party entities.
*In the EMEA region, transducers are not included and must be purchased separately.
(1) 781-419-3900 *In the EMEA region, the test block is not included and must be purchased separately.
38DL PLUS, THRU-COAT, Sonopen, GageView, 38-Link, and Microscan are trademarks of Evident Corporation or its
subsidiaries. Copyright © 2023 by Evident.

EvidentScientific.com 38DL_PLUS_EN_2023_11 • 920-212-EN Rev. E

You might also like