0% found this document useful (0 votes)
11 views1 page

8

The document lists mandatory requirements for postweld heat treatment of pressure parts and attachments for various equipment denoted as P-No. It also includes other technical specifications and guidelines denoted by codes like PR, PB, PL, and A.

Uploaded by

TAHIR MAHMOOD
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
11 views1 page

8

The document lists mandatory requirements for postweld heat treatment of pressure parts and attachments for various equipment denoted as P-No. It also includes other technical specifications and guidelines denoted by codes like PR, PB, PL, and A.

Uploaded by

TAHIR MAHMOOD
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

PW-39-4 Mandatory Requirements for Postweld Heat Treatment of Pressure Parts

and Attachments — P-No. 5A and P-No. 5B . . . . . . . . . . . . . . . . . . 118


PW-39-5 Mandatory Requirements for Postweld Heat Treatment of Pressure Parts
and Attachments — P-No. 15E . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
PW-39-6 Mandatory Requirements for Postweld Heat Treatment of Pressure Parts
and Attachments — P-No. 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
PW-39-7 Mandatory Requirements for Postweld Heat Treatment of Pressure Parts
and Attachments — P-No. 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
PW-39-8 Mandatory Requirements for Postweld Heat Treatment of Pressure Parts
and Attachments — P-No. 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
PW-39-9 Mandatory Requirements for Postweld Heat Treatment of Pressure Parts
and Attachments — P-No. 10H . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
PW-39-10 Mandatory Requirements for Postweld Heat Treatment of Pressure Parts
and Attachments — P-No. 10I . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
PW-39-11 Mandatory Requirements for Postweld Heat Treatment of Pressure Parts
and Attachments — P-No. 31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
PW-39-12 Mandatory Requirements for Postweld Heat Treatment of Pressure Parts
and Attachments — P-No. 43 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
PW-39-13 Mandatory Requirements for Postweld Heat Treatment of Pressure Parts
and Attachments — P-No. 45 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
PW-39-14 Mandatory Requirements for Postweld Heat Treatment of Pressure Parts
and Attachments — P-No. 51 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
PW-39.1 Alternate Postweld Heat Treatment Requirements for Carbon and Low
Alloy Steels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
PW-39.2 Mandatory Requirements for Postweld Heat Treatment Temperature
Ranges for Welds Between P-No. 1, 3, 4, 5A, 5B Group 1, 6, 7, 8, and 15E
Group 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
PR-9-1 Minimum Thickness of Buttstraps . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
PR-15.3-1 Allowable Stress on Rivets in Tension . . . . . . . . . . . . . . . . . . . . . . . . 141
PB-1 Maximum Design Temperatures for Brazing Filler Metal . . . . . . . . . . . 147
PB-16 Recommended Joint Clearance at Brazing Temperature . . . . . . . . . . . 149
PL-21.3.4-1 Thickness of Riveted Reinforcing Rings for Dome Openings . . . . . . . . 158
PL-24.1-1 Maximum Allowable Working Pressure for Steel Flues for Firetube
Locomotive Boilers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161
PL-28.4-1 Radii for Firebox Mudrings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167
PL-30.4.5-1 Fillet-Welded Staybolt: Examples of Nominal Dimensions Permitted
±0.02 in. (±0.5 mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168
PHRSG-4 Minimum Drain Pot Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218
V-4-1 Sizes of Angles Required for Staying Segments of Heads . . . . . . . . . . 227
VIII-6.3.2-1 Control Zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236
A-44 Guide for Estimating Steaming Capacity Based on Heating Surface . . . 262
A-75-1 ................................................... . 281
A-250.3.2 Maximum Permissible Size of Rounded Indication (Examples Only) . . . 283
A-351 Guide for Completing Manufacturer’s Data Report, Form P-2 (See
PG-112.2.1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 297
A-351.1 Guide for Completing Manufacturer’s Data Report, Form P-2A (See
PG-112.2.1.1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302
A-351.2 Guide for Completing Manufacturer’s Data Report, Form P-2B (See
PG-112.2.1.2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 306

xxi

You might also like