Honeywell Morley

Download as pdf or txt
Download as pdf or txt
You are on page 1of 30

Addressable Fire Alarm Control Panel

Model: SMX
The SMX model is designed keeping in mind the needs of today’s
performance conscious establishments. It is a range of compact
and feature-rich, modern-age panels that constitute together with
a suite of intelligent devices, highly reliable fire alarm systems.

The SMX panels meet the requirements of the latest codes and standards
and allow for quick and easy installation. Just fix the panel to the wall,
connect the field wiring devices, and power up the panel for a working fire
alarm system. The large touch display allows the panel to be programmed
easily by providing a clear menu structure, making the the entire setup
process extremely intuitive. Complex configuration is made easy by
using the mobile appl and the Bluetooth dongle connectivity.

USER INTERFACE DEVICES AND LOOP CAPACITY


Display: 5-inch multi-color touch display Supports Morley IAS UL detectors
Control Keys: Silence Buzzer, Silence/Resound Alarm, Reset & modules
Indicators: Power, Alarm Silenced, Trouble, System Trouble, Loop Capacity: 500 mA per loop
Disabled Test Supervisory, Delay

SKU NO. DESCRIPTION NUMBER OF LOOP COLOR DEVICES DEVICES / LOOP ADDRESS RANGE DEVICES / PANEL

SMX 1 loop panel supporting up to 198 Sensors 159 1 – 159 159


915-100-202 1 Grey
devices in a grey color metal enclosure Modules 39 161 – 199 39

SMX 1 loop panel supporting up to 198 Sensors 159 1 – 159 159


915-100-102-R 1 Red
devices in a red color metal enclosure Modules 39 161 – 199 39

SMX 2 loop panel supporting up to 396 Sensors 159 1 – 159 318


915-100-202 2 Grey
devices in a grey color metal enclosure Modules 39 161 – 199 78

SMX 2 loop panel supporting up to 396 Sensors 159 1 – 159 378


915-100-202-R 2 Red
devices in a red color metal enclosure Modules 39 161 – 199 78

SMX 4 loop panel supporting up to 792 Sensors 159 1 – 159 636


915-100-402 4 Grey
devices in a grey color metal enclosure Modules 39 161 – 199 156

SMX 4 loop panel supporting up to 792 Sensors 159 1 – 159 636


915-100-402-R 4 Red
devices in a red color metal enclosure Modules 39 161 – 199 156

K E Y F E AT U R E S
• Multiple loop options – 1, 2, and 4 loops • Pluggable electrical connectors and • Ability to configure panels off-site
ergonomic design for easy installation and sync via USB pen drive
• Up to 198 devices per full loop
or Honeywell Bluetooth
• Large touch display for enhanced
• 160 fire zones
readability, context-awareness • Battery-backed, real-time clock (RTC)
• 10,000 events log and easy navigation resulting in
• 32-bit dual-core microprocessor
• Multiple output and input interfaces for exemplified user experience
• UL 864 10 th Edition Certified
a fully integrated fire alarm solution • Mobile and PC apps for
guided configuration
SMX Technical Specifications
INTERFACES
• 3 Output Relays with single pole changeover 24V DC 1 A: Fire Trouble & Programmable (Supervisory by default)
• 1 RS485 port for up to 8 repeaters or mimics or a combination of the two
• 1 RS232 ports: One for serial printer
• 2 USB ports: One for pen drive and Honeywell Bluetooth dongle and one reserved for future use
• 2 NAC circuit with max 150 mA each
• 2 on-board monitored inputs

MECHNICAL SPECIFICATIONS

DIMENSIONS [MM] (H X W X D) 531x451x178

WEIGHT (EXCLUDING BATTERIES) 9 kg (317 oz)

COLOUR Grey & red

MOUNTING HOLES 5

KNOCKOUTS (20MM) Top: 16; Bottom: 4; Side: 4; Back: 2

MOUNTING TYPE Surface and Flush

OPERATING TEMPERATURE 0°C to +49°C

RELATIVE HUMIDITY 5% - 95% non-condensing

MATERIAL Powder Coated Mild Steel.

IP RATING 30

ELECTRICAL SPECIFICATIONS

OPERATING VOLTAGE 230V AC, 50/60 Hz

PSU RATING 24V DC 6.5 A

2 loop (915-100-102) - 2 x 12Ah


STAND-BY BATTERIES 4 loop (615-000-202) - 2 x 18 Ah or 2 x 24 Ah
(based on battery back-up calculations)

STAND-BY BATTERY DURATION 24 hours back-up under normal condition

AUXILLIARY OUTPUT 2 units of 24 V Dc 100 mA each

FIELD STRENGTH 52V/m for 5W test condition

Agency Listings and Approvals


Listing and approval below apply to the modules specified in this. In some cases, certain modules may not be
listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status.
• UL Listed: S36244

For more information


www.morley-ias.co.uk

Honeywell Building Technologies ASEAN Honeywell Building Technologies META


Level 25, UOA Corp Tower B, Avenue 10 Emaar Business Park, Building 2, 2nd Floor
The Vertical, Bangsar South City Sheikh Zayed Road
59200, Kuala Lumpur, Malaysia P.O.Box 232362, Dubai, U.A.E.
Email: [email protected] Phone: +971 4 4505 847

Honeywell Building Technologies India


Unitech Trade Centre, 5th Floor
Sector – 43, Block C, Sushant Lok Phase – 1
Gurgaon – 122002, Haryana, India
Email: HoneywellSecurity&[email protected]
Toll Free: 1-800-103-0339 SMX DS | Rev 01 | 08/19
www.honeywell.com © 2019 Honeywell International Inc.
Addressable Fire Alarm Control Panel

Model: STX
The STX model is designed keeping in mind the needs of today’s
performance conscious establishments. It is a range of compact and
feature-rich, modern-age panels that constitute together with a suite of
intelligent devices, highly reliable fire alarm systems.

The STX panels meet the requirements of the latest codes and standards
and allow for quick and easy installation. Just fix the panel to the wall,
connect the field wiring devices, and power up the panel for a working
fire alarm system. The large touch display allows the panel to be
programmed easily by providing a clear menu structure, making the the
entire setup process extremely intuitive. Complex configuration is made
easy by using the mobile app and the Bluetooth dongle connectivity.

USER INTERFACE DEVICES AND LOOP CAPACITY


Display: 5-inch multi-color touch display Supports Morley IAS UL detectors
Control Keys: Silence Buzzer, Silence/Resound Alarm, Reset & modules
Indicators: Power, Alarm Silenced, Trouble, System Trouble, Loop Capacity: 500 mA per loop
Disabled, Test, Supervisory, Delay

SKU NO. DESCRIPTION NUMBER OF LOOP COLOR DEVICES DEVICES / LOOP ADDRESS RANGE DEVICES / PANEL

STX 1 loop panel supporting up to 98 Sensors 59 1 – 59 59


615-000-002 1 Grey
devices in a grey color plastic enclosure Modules 39 161 – 199 39

STX 1 loop panel supporting up to 98 Sensors 59 1 – 59 59


615-000-002-R 1 Red
devices in a red color plastic enclosure Modules 39 161 – 199 39

STX 1 loop panel supporting up to 198 Sensors 159 1 – 159 159


615-000-102 1 Grey
devices in a grey color plastic enclosure Modules 39 161 – 199 39

STX 1 loop panel supporting up to 198 Sensors 159 1 – 159 159


615-000-102-R 1 Red
devices in a red color plastic enclosure Modules 39 161 – 199 39

STX 2 loop panel supporting up to 396 Sensors 159 1 – 159 318


615-000-202 2 Grey
devices in a grey color plastic enclosure Modules 39 161 – 199 78

STX 2 loop panel supporting up to 396 Sensors 159 1 – 159 318


615-000-202-R 2 Red
devices in a red color plastic enclosure Modules 39 161 – 199 78

K E Y F E AT U R E S
• Multiple loop options –half, 1 and 2 loops • Pluggable electrical connectors and • Ability to configure panels off-
ergonomic design for easy installation site and sync via USB pen drive
• Up to 198 devices per full loop
or Honeywell Bluetooth
• Large touch display for enhanced
• 160 fire zones
readability, context-awareness • Battery-backed, real-time clock (RTC)
• 5,000 events log and easy navigation resulting in
• 32-bit dual-core microprocessor
• Multiple output and input interfaces for exemplified user experience
• UL 864 10th Edition Certified
a fully integrated fire alarm solution • Mobile and PC apps for
guided configuration
STX Technical Specifications
INTERFACES
• 3 Output Relays with single pole changeover 24V DC 1 A: Fire Trouble & Programmable (Supervisory by default)
• 1 RS485 port for up to 4 repeaters or mimics or a combination of the two
• 1 RS232 ports: One for serial printer
• 2 USB ports: One for pen drive and Honeywell Bluetooth dongle and one reserved for future use
• 1 NAC circuit with max 150 mA
• 2 on-board monitored inputs

MECHNICAL SPECIFICATIONS

DIMENSIONS [MM] (H X W X D) 465x408x153

WEIGHT (EXCLUDING BATTERIES) 7 Kg (246 oz)

COLOUR Grey & red

MOUNTING HOLES 3

KNOCKOUTS (20MM) Top: 16; Back: 2

MOUNTING TYPE Surface Only

OPERATING TEMPERATURE 0°C to +49°C

RELATIVE HUMIDITY 5% - 95% non-condensing

MATERIAL PC+ABS plastic (BAYBLEND FR3010- UL 94 5VA)..

IP RATING 30

ELECTRICAL SPECIFICATIONS

OPERATING VOLTAGE 230V AC, 50/60 Hz AC


1 loop (615-000-002 and 615-000-102) - 24V DC 2 A
PSU RATING
2 loop (615-000-202) - 24V DC 6.25 A
STAND-BY BATTERIES 2 x 12Ah (recommended)

STAND-BY BATTERY DURATION 24 hours back-up under normal condition

AUXILLIARY OUTPUT 24 V Dc 100 mA

FIELD STRENGTH 52V/m for 5W test condition

Agency Listings and Approvals


Listing and approval below apply to the modules specified in this. In some cases, certain modules may not be
listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status.
• UL Listed: S36244

For more information


www.morley-ias.co.uk

Honeywell Building Technologies ASEAN Honeywell Building Technologies META


Level 25, UOA Corp Tower B, Avenue 10 Emaar Business Park, Building 2, 2nd Floor
The Vertical, Bangsar South City Sheikh Zayed Road
59200, Kuala Lumpur, Malaysia P.O.Box 232362, Dubai, U.A.E.
Email: [email protected] Phone: +971 4 4505 847

Honeywell Building Technologies India


Unitech Trade Centre, 5th Floor
Sector – 43, Block C, Sushant Lok Phase – 1
Gurgaon – 122002, Haryana, India
Email: HoneywellSecurity&[email protected]
Toll Free: 1-800-103-0339 STX DS | Rev 01 | 08/19
www.honeywell.com © 2019 Honeywell International Inc.
Fire Panel Commissioning
Bluetooth Dongle

315-508
Honeywell Bluetooth USB Dongle is an elegant Bluetooth
Low Energy (BLE) product that is used for seamlessly
interfacing with the Morley STX and SMX fire panel models.

The Honeywell Bluetooth Dongle (HONBLEKIT2)


is a plug and play module that enables wireless
communication between the panel and the Honeywell
SmartConfig™ mobile application for simple, smart and
secure commissioning and maintenance operations. Honeywell Bluetooth Dongle (HONBLEKIT2)
The HONBLEKIT2 is compatible with
SmartConfig version 2.0.0.0 onwards.

Honeywell Bluetooth Dongle Specification: FCC Statement:


Contains FCC ID: QOQBLED112
CONTAINS BLUETOOTH 4.0 QUALIFIED SINGLE-MODE MODULE
This HONBLEKIT2 complies with part 15 of the FCC Rules.
VBUS -0.3 to 6.5 V Operation is subject to the following two conditions:
Operating Temperature Range -40 to +85°C • This device may not cause harmful interference
TX current consumption (radio only, 0dBm) 12.1 mA • This device must accept any interference received

RX current consumption (Radio only) 33 mA


CAUTION: Changes or modifications not expressly
TX output power 44 mA approved by the manufacturer could void the
Approvals/ Certifications WPC, FCC authority of the user to operate the equipment.

F E AT U R E S :
Following are the features of Honeywell wireless commissioning:
• Provides seamless wireless low power Bluetooth Connectivity to Morley STX and SMX fire panel models
• Eases the panel commissioning and maintenance operations through Honeywell SmartConfig™ Mobile app
• Enables productivity through a simple interface
• Eliminates the need to carry laptops, cables and so on to the site for configuration
How to connect the Honeywell Bluetooth USB Dongle to the fire panel?
1. Open the fire panel’s front door.
2. Look for the “USB 1” on the top
behind the display board.
3. Plug the USB dongle into
the “USB 1” port.

How to connect via Bluetooth to program the fire panel?

1 2 3 4

SMARTCONFIG

Launch the Honeywell Morley-IAS Establish a bluetooth connectivity Configure the Fire Alarm Control Voila! The Fire Alarm Control
SmartConfig™ mobile application. between mobile application and Panel using™ Quickwizard. Panel is configured.
Fire Alarm Control panel.

1. Ensure that the Honeywell Bluetooth USB Dongle is connected to the fire panel.
2. On the panel, tap Commissioning from the Main Menu.
3. Tap next to Configuration via Bluetooth.
4. On the mobile, switch-on the Bluetooth and discover, select the HONBLEKIT2 connection.
5. Enter the pass-code that appears on the panel screen into your mobile device.
6. The Bluetooth icon gets activated on the panel screen as soon as the panel is paired with the mobile device.
7. Now you can send the configuration from mobile to the panel or read from the panel, as required.

For more details on programing the fire panel via Bluetooth, refer to one or more of the following resources as required:

1. FAQ from within the SmartConfig™ mobile app.


2. SmartConfig™ PC Application User’s Guide (NS-MS-0020)
3. STX SMX Programming Guide (NS-MN-0017)

Product Line Information


315-508: BLE Dongle for Wireless Commissioning

For more information


www.morley-ias.co.uk

Honeywell Building Technologies ASEAN Honeywell Building Technologies META


Level 25, UOA Corp Tower B, Avenue 10 Emaar Business Park, Building 2, 2nd Floor
The Vertical, Bangsar South City Sheikh Zayed Road
59200, Kuala Lumpur, Malaysia P.O.Box 232362, Dubai, U.A.E.
Email: [email protected] Phone: +971 4 4505 847

Honeywell Building Technologies India


Unitech Trade Centre, 5th Floor
Sector – 43, Block C, Sushant Lok Phase – 1
Gurgaon – 122002, Haryana, India
Email: HoneywellSecurity&[email protected]
Toll Free: 1-800-103-0339 FPC Bluetooth Dongle DS | Rev 01 | 08/19
www.honeywell.com © 2019 Honeywell International Inc.
Addressable Relay Module

HM-D240CMO-UL
General
The HM-D240CMO-UL Addressable Relay Module provides
the system with a dry contact output for activating a variety of
auxilary devices, such as fans, door holders, dampers, control
equipment, etc. Addressability allows the dry contact to be
activated through panel programming, on a select basis.

Applications
The HM-D240CMO-UL may be programmed to operate
dry contacts for door holders, Air Handling Unit shutdown,
etc., and to reset four-wire smoke detector power.

Construction HM-D240CMO-UL
• The face plate is made of off-white, heat resistant plastic

• Controls include two rotary switches for direct-dial entry of


address-setting

• The HM-D240CMO-UL is configured for a single


Class B Notification Appliance Circuit

• The HM-D240CMO-UL provides two Form-C


dry contacts that switch together

Operation NOTE: Open/short supervision is suspended


with the HM-D240CMO-UL.
Each HM-D240CMO-UL uses one of the addresses on a
Rotary switches set a unique address for each module.
SLC loop. It responds to regular polls from the control panel
The address may be set before or after mounting.
and reports its type and status. The LED blinks with each The built-in TYPE CODE (not settable) will identify
the module to the control panel, so as to differentiate
poll received. On command, it activates its internal relay. between a control module and a relay module.

F E AT U R E S & B E N E F I T S

• Built-in type identification • Integral LED “blinks” green each • Wide viewing angle of LED
automatically identifies these time a communication is received
• SEMS screws with clamping
devices to the control panel from the control panel and turns
plates for wiring ease
on in steady red when activated
• Internal circuitry and relay powered
• Direct-dial entry of address:
directly by two-wire SLC loop • High noise immunity (EMF/RFI)
61 -99 for models SMX and STX
HM-D240CMO-UL Technical Specifications

PARAMETER SPECIFICATION
Normal operating voltage 15 to 32 VDC
Maximum SLC current draw 6.5 mA (LED on)
Average operating current 230 μA direct poll (CLIP mode) with LED flashing
EOL resistance Not Used.
Temperature range 32°F to 120°F (0°C to 49°C)
Humidity range 10% to 93% non-condensing
4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm)
Dimensions
square x 2.215" (5.398 cm) deep box

Relay Contact Ratings


• Load Descripton: Resistive
• Application: Non-Coded
• Maximum Voltage: 30 VDC
• Current Rating: 3.0 A

Agency Listings and Approvals


Listing and approval below apply to the modules specified in this. In some cases, certain modules may not be
listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status.
• UL: S35595

Product Line Information


HM-D240CMO-UL Intelligent addressable relay module

SMB500 Optional surface-mount backbox

Optional control module barrier, required by UL for separating power-limited and non-power-limited wiring in
CB500
the same junction box as HM-D240CMO-UL

NOTE: For installation instructions, see document CN-MN-0195 and refer to the SLC Wiring Manual.

Honeywell Building Technologies ASEAN Honeywell Building Technologies META


Level 25, UOA Corp Tower B, Avenue 10 Emaar Business Park, Building 2, 2nd Floor
The Vertical, Bangsar South City Sheikh Zayed Road
59200, Kuala Lumpur, Malaysia P.O.Box 232362, Dubai, U.A.E.
Email: [email protected] Phone: +971 4 4505 847

Honeywell Building Technologies India


Unitech Trade Centre, 5th Floor
Sector – 43, Block C, Sushant Lok Phase – 1
Gurgaon – 122002, Haryana, India
Email: HoneywellSecurity&[email protected]
Toll Free: 1-800-103-0339 HM-D240CMO-UL | Rev 01 | 08/19
www.honeywell.com © 2019 Honeywell International Inc.
Addressable Control Module

HM-DCMO-UL
General
The HM-DCMO-UL Addressable Control Module provides a
circuit for Notification appliances like horns, strobes, and more.
Addressability allows the HM-DCMO-UL to be activated through
panel programming, on a select (zone or area of coverage) basis.

Applications Product Photo on White Background


The HM-DCMO-UL is used to switch 24 VDC audible/visual power.

Construction
• The face plate is made of off-white, heat resistant plastic

• Controls include two rotary switches for direct-dial entry of HM-DCMO-UL


address-setting

• The HM-DCMO-UL is configured for a single


Class B Notification Appliance Circuit

Operation
Each HM-DCMO-UL uses one of the module addresses on a from the communication loop, so that a
SLC loop. It responds to regular polls from the control panel and trouble condition on the external power supply
reports its type and status, including the open/normal/ short status doesn’t interfere with the rest of the system.
of its Notification Appliance Circuit (NAC). The LED blinks with Rotary switches set a unique address for
each poll received. On command, it activates its internal relay. The each module. The address may be set
HM-DCMO-UL supervises Class B notification or control circuits. before or after mounting. The built-in TYPE
Upon code command from the panel, the HM-DCMO-UL will CODE (not settable) of the control panel will
disconnect the supervision and connect the external power supply in identify the module, so as to differentiate
the proper polarity across the load device. The disconnection of the between a module and a sensor address.
supervision provides a positive indication to the panel that the control
relay turned ON. The external power supply is always relay-isolated

F E AT U R E S & B E N E F I T S

• Built-in type identification • Integral green LED blinks each • Wide viewing angle of LED
automatically matches devices time a communication is received
• SEMS screws with clamping
to the control panel from the control panel and turns
plates for easy wiring
on steady red when activated
• Internal circuitry powered directly
• Direct-dial entry of address:
by a two-wire SLC loop The • High noise immunity (EMF/RFI)
61 -99 for models SMX and STX
HM-DCMO-UL module requires
• The HM-DCMO-UL may be used
power (for horns, strobes, etc.)
to switch 24-volt NAC power
HM-DCMO-UL Technical Specifications
PARAMETER SPECIFICATION

Normal operating voltage 15 to 32 VDC

Maximum SLC current draw 6.5 mA (LED on)

Average operating current 350 A direct poll (CLIP mode) with LED flashing

External supply voltage maximum 80 Volts (RMS or DC)

Drain on external supply 2 mA maximum (using internal EOL relay)

EOL resistance 47K ohms

Temperature range 32°F to 120°F (0°C to 49°C)

Humidity range 10% to 93% non-condensing

• 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep
Dimensions
• Mounts to a 4" (10.16 cm) square x 2.215" (5.398 cm) deep box

Agency Listings and Approvals


Listing and approval below apply to the modules specified in this. In some cases, certain modules may not be
listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status.

• ULC: S35595

Product Line Information


HM-DCMO-UL Intelligent addressable control module

SMB500 Optional surface-mount backbox

Optional control module barrier, required by UL for separating power-limited and non-power-limited wiring in
CB500
the same junction box as HM-DCMO-UL

NOTE: For installation instructions, see document CN-MN-0194 and refer to the SLC Wiring Manual.

Honeywell Building Technologies ASEAN Honeywell Building Technologies META


Level 25, UOA Corp Tower B, Avenue 10 Emaar Business Park, Building 2, 2nd Floor
The Vertical, Bangsar South City Sheikh Zayed Road
59200, Kuala Lumpur, Malaysia P.O.Box 232362, Dubai, U.A.E.
Email: [email protected] Phone: +971 4 4505 847

Honeywell Building Technologies India


Unitech Trade Centre, 5th Floor
Sector – 43, Block C, Sushant Lok Phase – 1
Gurgaon – 122002, Haryana, India
Email: HoneywellSecurity&[email protected]
Toll Free: 1-800-103-0339 HM-DCMO-UL | Rev 01 | 08/19
www.honeywell.com © 2019 Honeywell International Inc.
Fault Isolator Module

HM-DISO-UL
General
The HM-DISO-UL Fault Isolator Module is used with the fire alarm control
panels (FACPs) to protect the system against wire-to-wire short circuits
on the SLC loop. The HM-DISO-UL should be placed between each
device on the SLC loop to isolate a short circuit problem between the
modules. It is required for true Style 7 operation, so that other devices can
continue to operate normally in the event of a short circuit on the SLC.

Application
The Fault Isolator Modules should be spaced between groups of
sensors in a loop to protect the rest of the loop. The HM-DISO-
UL supports a maximum of 25 devices in between isolators.

HM-DISO-UL

F E AT U R E S & B E N E F I T S

• Powered by SLC loop directly, no external power required


• Mounts in standard junction boxes (4.0”/10.16 cm square, 2.125”/5.398 cm deep)
• Integral LED blinks to indicate normal condition and illuminates steady when short circuit condition is detected
• High noise (EMF/RFI) immunity
HM-DISO-UL Technical Specifications
SPECIFICATIONS Engineering Specifications
Fault Isolator Modules shall be provided to automatically isolate
Operating voltage 15 – 32 VDC (peak)
wire-to-wire short circuits on an SLC loop. The Fault Isolator Module
Maximum current upon limits the number of modules or detectors that may be rendered
Refer to the manual for the main FACP
activation due to short circuit
inoperative by a short circuit fault on the SLC Loop. If a wire-to-wire
450 μA maximum; HM-DISO-UL is not isolated short occurs, the Fault Isolator Module automatically disconnects
Standby current
through a closed relay
the SLC loop. When the short circuit condition is corrected, the
Temperature range 32°F to 120°F (0°C to 49°C) Fault Isolator Module automatically reconnects the isolated section
Relative humidity 10% to 93% of the SLC loop. The Fault Isolator Module doesn’t require any
address, as operations switch to automatic mode. Replacing or
Weight 5 oz. (150 grams)
resetting the Fault Isolator Module is not required, after operating
4.5”H x 4.5”W x 0.25” D (11.43 cm H x 11.43 cm normally. The Fault Isolator Module shall mount in a standard 4"
Dimensions
W x 0.635 cm D)
(10.16 cm) deep electrical box, in a surface mounted backbox, or in
the Fire Alarm Control Panel. It provides a single LED that flashes
Construction
when the Isolator is operational and illuminates steadily to indicate
The face plate is made of off-white plastic. Module includes
that a short circuit condition has been detected and isolated.
yellow LED indicator that pulses to indicate normal conditions
and illuminates steady when a short is detected.
Agency Listings and Approvals
Listing and approval below apply to the modules specified
Operation
in this. In some cases, certain modules may not be
The circuit is automatically opened when the voltage line drops
listed by certain approval agencies, or listing may be in
below four volts. Fault Isolator Modules should be spaced
process. Consult factory for latest listing status.
between groups of addressable devices (maximum 25), in a
loop that protects the rest of the loop. If a short occurs between • UL Listed: S35595
any two isolators, then both isolators immediately switch to an
open circuit state and isolate the groups of sensors between Product Line Information
them. The remaining units on the loop continue to fully operate.
HM-DISO-UL Isolator module
The HM-DISO-UL Fault Isolator Module automatically restores
SMB500 Optional surface-mount backbox
the shorted portion of the communications loop to normal.

Installation
• Mount on a standard junction box (4.0”/10.16 cm
square) which is at least 2.125”/5.398 cm deep
• Terminal screws are provided for “in and out” wiring
• Installation instructions are provided with each module
• Surface mount box available

Honeywell Building Technologies ASEAN Honeywell Building Technologies META


Level 25, UOA Corp Tower B, Avenue 10 Emaar Business Park, Building 2, 2nd Floor
The Vertical, Bangsar South City Sheikh Zayed Road
59200, Kuala Lumpur, Malaysia P.O.Box 232362, Dubai, U.A.E.
Email: [email protected] Phone: +971 4 4505 847

Honeywell Building Technologies India


Unitech Trade Centre, 5th Floor
Sector – 43, Block C, Sushant Lok Phase – 1
Gurgaon – 122002, Haryana, India
Email: HoneywellSecurity&[email protected]
Toll Free: 1-800-103-0339 HM-DISO-UL | Rev 01 | 08/19
www.honeywell.com © 2019 Honeywell International Inc.
Addressable Monitor Modules

HM-DMMI-UL, HM-MM3E-UL, HM-DCZRM-UL


General
Three different monitor modules are available for fire alarm The HM-DMMI-UL Monitor Module is intended
control panels – suiting a variety of applications. Monitor for use in intelligent, two-wire systems, where
modules supervise a circuit of drycontact input devices, the individual address of each module is selected
such as conventional heat detectors and pull stations, or using the built-in rotary switches. It provides
to monitor and power two-wire smoke detector circuits. either a two-wire or four-wire fault-tolerant
Initiating Device Circuit (IDC) for normally open,
HM-DMMI-UL is a standard-sized module (typically
contact fire alarm and supervisory devices. The
mounts to a 4”/10.16 cm square box) that supervises
module has a panel-controlled LED indicator.
Class B circuit of dry contact input devices.
HM-DMMI-UL Applications
HM-MM3E-UL is a miniature monitor module – 1.3” (3.302
Monitor a zone of four-wire smoke detectors, manual
cm) H x 2.75” (6.985 cm) W x 0.65” (1.651 cm) D – that
fire alarm pull stations, waterflow devices, or other
supervises Class B circuit of dry-contact input devices.
normally open, drycontact alarm activation devices.
Thanks to its compact design, the HM-MM3E-UL can be
Use it to monitor normally-open supervisory devices
mounted in a single-gang box behind the device it monitors.
with special supervisory indication at the control
HM-DCZRM-UL is a standard-sized module used to panel. The monitored circuit may be wired as an NFPA
monitor and supervise compatible two-wire, (Class B) Initiating Device Circuit. A 47K Ohm end of
24-Volt, smoke on a Class B circuit. line resistor (provided) terminates the Class B circuit.

HM-DMMI-UL Operation
HM-DMMI-UL Monitor Module Each HM-DMMI-UL uses one of the available
module addresses on an SLC loop. It responds to
regular polls from the control panel and reports
its type and the status (open/normal/short) of
its Initiating Device Circuit (IDC). A flashing LED
indicates that the module communicates with the
control panel. The LED steadily illuminates when an
alarm starts (subject to current loop limitations).

HM-DMMI-UL Specifications
Nominal operating voltage 15 to 32 VDC

Maximum current draw 5.0 mA (LED on)


375 μA (LED flashing), 1 communication
Average operating current
every 5 seconds, 47k EOL

HM-DMMI-UL Maximum IDC wiring


1500 Ohms
resistance
• Built-in type identification automatically identifies this Maximum IDC Voltage 11 V
device as a monitor module to the control panel EOL resistance 47K Ohms
• Powered directly by two-wire SLC loop. No additional power required
Temperature range 32°F to 120°F (0°C to 49°C)
• High noise (EMF/RFI) immunity
Humidity range 10% to 93% non-condensing
• SEMS screws with clamping plates for easy wiring
• Direct-dial entry of address: 61-99 for models SMX and STX 4.5" (11.43 cm) high x 4" (10.16 cm)
wide x 1.25" (3.175 cm) deep. Mounts to
• LED flashes during normal operation and Dimensions
a 4" (10.16 cm) square x 2.125" (5.398
steadily illuminates to indicate alarm cm) deep box
HM-MM3E-UL Min-Monitor Module HM-MM3E-UL Operation
Each HM-MM3E-UL uses one of the available module
addresses on an SLC loop. It responds to regular polls
from the control panel and reports its type and the status
(open/normal/short) of its Initiating Device Circuit (IDC).

HM-MM3E-UL Specifications
Nominal operating voltage 15 to 32 VDC
HM-MM3E-UL
350 A, 1 communication every 5 seconds, 47k
Average operating current
EOL; 600 A Max. (Communicating, IDC Shorted)
Maximum IDC wiring resistance 1500 Ohms
• Powered directly by two-wire SLC loop Maximum IDC Voltage 11 V
No additional power required Maximum IDC Current 450 A

• High noise (EMF/RFI) immunity EOL resistance 47K Ohms

• Tinned, stripped leads for easy wiring Temperature range 32°F to 120°F (0°C to 49°C)
Humidity range 10% to 93% non-condensing
• Direct-dial entry of address:
1.3” (3.302 cm) high x 2.75” (6.985 cm) wide x
61-99 for models SMX and STX Dimensions
0.65” (1.651 cm) deep
Wire length 6” (15.24 cm) minimum

HM-DCZRM-UL Interface Module

HM-DCZRM-UL

The HM-MM3E-UL Min-Monitor Module can be • Supports compatible two-wire smoke detectors

installed in a single-gang junction directly behind the • Supervises IDC wiring and connection
monitored unit. Its small size and light weight allow it to of external power source
be installed without rigid mounting. The HM-MM3E-UL • High noise (EMF/RFI) immunity
is intended for use in intelligent, two-wire systems where • SEMS screws with clamping plates for ease of wiring
the individual address of each module is selected using • Direct-dial entry of address:
rotary switches. It provides a two-wire initiating device 61 -99 for models SMX and STX
circuit for normally open, contact fire alarm devices.
• LED flashes during normal operation
HM-MM3E-UL Applications • LED steadily illuminates to indicate an alarm
Use to monitor a single device or a zone of four-wire on command from the control panel
smoke detectors, manual fire alarm pull stations, The HM-DCZRM-UL Interface Module is intended
waterflow devices, or other normally open, dry contact for use in intelligent, addressable systems, where the
devices. Monitor normally-open supervisory devices individual address of each module is selected using
with special supervisory indication at the control built-in rotary switches. This module allows intelligent
panel. Monitored circuit/device is wired as an NFPA panels to interface and monitor two-wire conventional
Class B Initiating Device Circuit. A 47K Ohm end of smoke detectors. It transmits the status (normal, open,
line resistor (provided) terminates the circuit. or alarm) of one full zone of conventional detectors
back to the control panel. All two-wire detectors being
monitored must be UL compatible with the module.
HM-DCZRM-Ul Applications Installation
Use the HM-DCZRM-UL to monitor a zone of two-wire HM-DMMI-UL, and HM-DCZRM-UL modules mount
smoke detectors. The monitored circuit may be wired as an directly to a standard 4” (10.16 cm) square, 2.125”
NFPA Class B Initiating Device Circuit. A 3.9 K Ohm end of (5.398 cm) deep, electrical box. They may also be
the line resistor (provided) terminates the end of the Class mounted to the SMB500 surface mount box. Mounting
B circuit (maximum IDC loop resistance is 25 Ohms). hardware and installation instructions are provided
with each module. All wiring must conform to applicable
HM-DCZRM-UL Operation
local codes, ordinances, and regulations. These
Each HM-DCZRM-UL uses one of the available
modules are intended for power-limited wiring only.
module addresses on an SLC loop. It responds to
regular polls from the control panel and reports The HM-MM3E-UL module is intended to be wired
its type and the status (open/normal/short) of and mounted without rigid connections, inside a
its Initiating Device Circuit (IDC). A flashing LED standard electrical box. All wiring must conform to
indicates that the module is in communicates with applicable local codes, ordinances, and regulations.
the control panel. The LED steadily illuminates when
an alarm is on (subject to current loop limitations).
Agency Listings and Approvals
HM-DCZRM-UL Specifications Listing and approval below apply to the modules specified
Nominal operating voltage 15 to 32 VDC in this. In some cases, certain modules may not be
Maximum current draw 5.1 mA (LED on) listed by certain approval agencies, or listing may be
Maximum IDC wiring resistance 25 Ohms in process. Consult factory for latest listing status.
270 A, 1 communication and 1 LED flash • UL: S35595
Average operating current
every 5 seconds, 3.9k eol
EOL resistance 3.9K Ohms Product Line Information
• DC voltage: 24 V power limited
External supply voltage
• Ripple voltage: 0.1 Vrms maximum HM-DMMI-UL Addressable Monitor Module
(between Terminals T10 and T11)
• Current: 90 mA per module maximum
HM-MM3E-UL Addressable Min-Monitor Module
Temperature range 32°F to 120°F (0°C to 49°C)
Humidity range 10% to 93% non-condensing HM-DCZRM-UL Addressable Interface Module

4.5” (11.43 cm) high x 4” (10.16 cm) wide NOTE: See installation instructions CN-MN-0196, CN-MN-0197
x 1.25” (3.175 cm) deep. Mounts to a 4”
Dimensions and CN-MN-0198 and refer to the SLC Wiring Manual.
(10.16 cm) square x 2.125” (5.398 cm)
deep box
Honeywell Building Technologies ASEAN Honeywell Building Technologies META
Level 25, UOA Corp Tower B, Avenue 10 Emaar Business Park, Building 2, 2nd Floor
The Vertical, Bangsar South City Sheikh Zayed Road
59200, Kuala Lumpur, Malaysia P.O.Box 232362, Dubai, U.A.E.
Email: [email protected] Phone: +971 4 4505 847

Honeywell Building Technologies India


Unitech Trade Centre, 5th Floor
Sector – 43, Block C, Sushant Lok Phase – 1
Gurgaon – 122002, Haryana, India
Email: HoneywellSecurity&[email protected] HM-DMMI-UL, HM-MM3E-UL,
Toll Free: 1-800-103-0339 HM-DCZRM-UL | Rev 01 | 08/19
www.honeywell.com © 2019 Honeywell International Inc.
Thermal Detectors

HM-FHSE-UL, HM-RHSE-UL
HM-HTSE-UL
General HM-RHSE-UL
HM-FHSE-UL
The HM-FHSE-UL, HM-RHSE-UL and HM-HTSE-UL Series
thermal detectors are addressable sensors that use a state-
of-the-art thermistor sensing circuit for fast response. These
sensors provide protection for open areas and can be used
use with addressable Fire Alarm Control Panels (FACPs).

The HM-FHSE-UL and HM-RHSE-UL sensors provide fixed


temperature detection at 135°F (57°C). The HM-RHSE-UL sensor HM-HTSE-UL
also responds to rate of rise conditions of greater than 15°F (8.3°C)
per minute. The HM-HTSE-UL is a fixed, high-temperature detector
that activates at 190°F (88°C). These thermal detectors provide
Construction
addressable property protection for a variety of applications.
These detectors are constructed of off-white fire-
Comes with two LEDs on each sensor that provide a local, visible resistant plastic. The HM-FHSE-UL Series plug-in,
sensor indication. The remote LED annunciator capability intelligent thermal detectors are designed to commercial
is available using an optional accessory, the RA100Z. standards and come with an appealing design.

Installation Operation
The HM-FHSE-UL Series of plug-in, intelligent Each HM-FHSE-UL Series detector uses one of 159
thermal detectors use a detachable base to simplify or 59 (Model: STX, 98 devices)possible addresses on a
installation, service, and maintenance. Installation control panel SLC loop. It responds to regular polls from
instructions are shipped with each detector. the control panel and reports type and status. If it receives
a test command from the panel (or a local magnet test),
Mount base on an electrical backbox which is at least 1.5” (3.81 cm) the detector stimulates its electronics and reports an
deep. For a chart of compatible junction boxes, see DF-60059. alarm. The LEDs blink when polled and the detector
turns the LEDs on when commanded by the panel. The
Application HM-FHSE-UL Series offer features and performance
Use thermal detectors for protection of property. that represent the latest in thermal detector technology.

F E AT U R E S & B E N E F I T S
SLC Loops: Operation: Mechanicals:
• Two-wire SLC loop connection • Factory preset at 135°F (57°C) for • Sealed against back pressure
• Unit uses base for wiring the HM-FHSE-UL and HM-RHSE-UL; • SEMS screws for wiring of
190°F (88°C) for the HM-HTSE-UL the separate base
Addressing:
• Rate-of-rise triggers at 15°F (8.3°C) • Designed for direct-surface or
• Addressable by device
per minute for the H355R(A) electrical-box mounting
• Rotary, decimal addressing:
• 360-degree viewing angle of the • Plugs into separate base for ease
1- 159 for models SMX and STX
visual alarm indicators. LEDs of installation and maintenance
Architecture: blink red in Normal condition and
Other system features:
• Sleek, low-profile, stylish design steadily illuminate red in Alarm
• Remote test feature from the panel
• State-of-the-art thermistor • Visible LEDs blink every time
• Walk test with address display
technology for fast response the unit is addressed
• Low standby current
• Integral communications and built-
• 94-5V plastic flammability rating
in device-type identification
• Built-in tamper resistant feature Options:
• Built-in functional test switch • Flanged surface mounting kit
activated by external magnet
HM-FHSE-UL, HM-RHSE-UL, HM-HTSE-UL Technical Specifications

PARAMETER SPECIFICATION
Agency Listings and Approvals
Listing and approval below apply to the modules specified
• 2.1" (5.3 cm) high; base determines diameter
Size in this. In some cases, certain modules may not be
• B501: 4.1” (10.4 cm) diameter
listed by certain approval agencies, or listing may be
Shipping weight 4.8 oz. (137 g)
in process. Consult factory for latest listing status.
• HM-FHSE-UL, HM-RHSE-UL: –4°F to 100°F
Installation temperature (–20°C to 38°C) • UL Listed: S36217
• HM-HTSE-UL: –4°F to 150°F (–20°C to 66°C)

Humidity range 10% to 93% relative humidity (non-condensing) PRODUCT LINE INFORMATION

Voltage range 15 to 32 VDC peak Intelligent thermal sensor; 135° F (57° C); B501
HM-FHSE-UL
base included
300 μA @ 24 VDC (one communication every five
Standby current Same as HM-FHSE-UL with rate of rise feature; B501
seconds with LED blink enabled) HM-RHSE-UL
base included
LED current 6.5 mA @ 24 VDC Intelligent, fixed, high-temperature thermal detector;
HM-HTSE-UL
190° F (88° C); B501 base included
135°F (57°C) for the HM-FHSE-UL and HM-RHSE-
Fixed-temperature setpoint
UL; 190°F (88°C) for the HM-HTSE-UL

Rate-of-rise detection Responds to greater than 15°F (8.3°C) per minute

ACCESSORIES

SMB600 Surface mounting kit

M02-04-00 Test magnet

M02-09-00 Test magnet with telescoping handle


Detector removal tool. Allows installation and/or
XR2B removal of detector heads from bases in high ceiling
applications
Extension pole for XR2B. Comes in three, 5-foot
XP-4
(1.524 m) sections
T55-127-010 Detector removal tool without pole

Honeywell Building Technologies ASEAN Honeywell Building Technologies META


Level 25, UOA Corp Tower B, Avenue 10 Emaar Business Park, Building 2, 2nd Floor
The Vertical, Bangsar South City Sheikh Zayed Road
59200, Kuala Lumpur, Malaysia P.O.Box 232362, Dubai, U.A.E.
Email: [email protected] Phone: +971 4 4505 847

Honeywell Building Technologies India


Unitech Trade Centre, 5th Floor
Sector – 43, Block C, Sushant Lok Phase – 1
Gurgaon – 122002, Haryana, India
Email: HoneywellSecurity&[email protected] HM-FHSE-UL, HM-RHSE-UL,
Toll Free: 1-800-103-0339 HM-HTSE-UL | Rev 01 | 07/19
www.honeywell.com © 2019 Honeywell International Inc.
Manual Call Point

HM-MCP-GLASS-UL
General
The HM-MCP-GLASS-ULis an addressable manual break glass call
point which, as a simple rotary decade, switch at the rear of the unit
for addressing.

A specialist test key may be inserted into the bottom of the unit to lower
the glass and release the micro-switch – enabling a complete
functionality test.

The HM-MCP-GLASS- UL call point is designed to provide a


manual alarm interface to Morley IAS’s fire alarm control panel.

Installation efficiency and compliance with the latest


standards are at the heart of the call point range.
HM-MCP-GLASS-UL

LED Status
The LED status is controlled by the fire panel and shows blinking RED
each time the device is polled, or continuous RED to indicate
fire detection.

Connection Details Dimensions

F E AT U R E S & B E N E F I T S

• Innovative “Plug and Play” installation concept


• Analogue addressable communications
• Integral LED
HM-MCP-GLASS-UL Technical Specifications

Mechnical Specifications
PARAMETER SPECIFICATION

• Semi-flush mounting: 89 x 93 x 27.5 (WxHxD)


Dimensions
• Surface mounting: 89 x 93 x 59.5 (WxHxD)

Weight 110g (3.8 oz.)

IP Rating IP24D

Operating Temperature 0°C to 49°C (32°F – 120°F)

Relative Humidity 10% - 93% non-condensing

Electrical Specifications
PARAMETER SPECIFICATION

Operating Voltage 15V to 32Vdc max

Current Consumption Quiescent (without isolator) 385μA Alarm Current: 7.8 mA

Optional Accessories
PART CODE DESCRIPTION

PS230 Pack of 10 resettable elements

MUS041W Manual call point back box

MUS156 Pack of 10 glass elements

SC070 Pack of 10 test keys

Agency Listings and Approvals


Listing and approval below apply to the modules specified in this. In some cases, certain modules may not be
listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status.

• UL Listed: S36215

Product Line Information


HM-MCP-GLASS-UL: Addressable break glass manual call point

Honeywell Building Technologies ASEAN Honeywell Building Technologies META


Level 25, UOA Corp Tower B, Avenue 10 Emaar Business Park, Building 2, 2nd Floor
The Vertical, Bangsar South City Sheikh Zayed Road
59200, Kuala Lumpur, Malaysia P.O.Box 232362, Dubai, U.A.E.
Email: [email protected] Phone: +971 4 4505 847

Honeywell Building Technologies India


Unitech Trade Centre, 5th Floor
Sector – 43, Block C, Sushant Lok Phase – 1
Gurgaon – 122002, Haryana, India
Email: HoneywellSecurity&[email protected]
Toll Free: 1-800-103-0339 HM-MCP-GLASS-UL | Rev 01 | 08/19
www.honeywell.com © 2019 Honeywell International Inc.
Photoelectric Detector

HM-PSE-UL
General
The HM-PSE-UL addressable, low-profile plug-in photoelectric
detectors use a state-of-the-art photoelectric sensing chamber
with communications to provide open area protection – used
exclusively with Fire Alarm Control Panels (FACPs). Since these
detectors are addressable, they will help emergency personnel
quickly locate a fire during its early stages, saving precious rescue
time while also reducing property damage. It comes with two LEDs
on each sensor light to provide a local, visible sensor indication.

Applications
The HM-PSE-UL uses photoelectric detectors in life safety applications
to provide a broad range of fire-sensing features, especially where
smoldering fires are anticipated. Ionization detectors are often
better than photoelectric detectors at sensing fast, flaming fires. HM-PSE-UL

Construction
These detectors are constructed of off-white, fire resistant plastic.
Operation
HM-PSE-UL plug-in, low-profile smoke detectors are designed
HM-PSE-UL has a unique unipolar chamber that
to commercial standards and have an appealing design.
responds quickly and uniformly to a broad range of
smoke conditions. It can withstand wind gusts up to
Installation
4,000 feet-per-minute (20 m/sec.) without sending
HM-PSE-UL plug-in detectors use a detachable mounting
an alarm level signal. Because of its unipolar
base to simplify installation, service, and maintenance.
chamber, the HM-PSE-UL is approximately two
Mount base (all base types) on an electrical backbox which is at least 1.5” times more responsive than most photoelectric
(3.81 cm) deep. For a chart of compatible junction boxes, see DF-60059. sensor – offering enhanced stability.

F E AT U R E S & B E N E F I T S

SLC Loop: Operation: Other System Features:


• Two-wire SLC loop connection • Withstands air velocities up to • Fully coated circuit boards and
• Unit uses base for wiring 4,000 feet-per-minute (20 m/sec.) superior RF/transient pro-tection
without triggering a false alarm • 94-V0 plastic flammability rating
Addressing:
• Factory preset at 1.5% nominal sensitivity • Low standby current
• Addressable by device
for panel alarm threshold level
• Rotary, decimal addressing:
• Visible LED blinks when the unit is
1- 159 for models SMX and STX addressed (communicating with the fire
Architecture: panel) and latches on in Alarm mode
• Unique single-source, dual-chamber Mechanicals:
design to respond quickly and • Sealed against back pressure
dependably to a broad range of fires • Direct surface mounting or
• Sleek, low-profile desig. electrical box mounting
• Integral communications and • Mounts to: single-gang box, 3.5” (8.89
built-in type identification cm) or 4.0” (10.16 cm) octagonal box,
• Built-in tamper-resistant feature or 4.0” (10.16 cm) square electrical
• Removable cover and insect-resistant box (using a plaster ring — included)
screen for simple field cleaning
HM-PSE-UL Technical Specifications
SPECIFICATION
Voltage range 15 – 32 VDC (peak)
Standby current 300 μA @ 24 VDC
LED current 6.5 mA @ 24 VDC (latched “ON”)
Air velocity 4,000 ft./min. (20 m/sec.) maximum
• 2.1” (5.33 cm) high; base determines diameter
Size
• B501: 4.1” (10.4 cm) diameter
Weight 3.6 oz. (102 g)
Operating temperature range for HM-PSE-UL: 0°C to 49°C (32°F to 120°F)
Temperature 0°C – 49°C (32°F – 120°F)
Relative humidity 10% – 93%, non-condensing

ACCESSORIES

SMB600 Surface mounting kit

M02-04-00 Test magnet

M02-09-00 Test magnet with telescoping handle

XR2B Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applications

XP-4 Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections

T55-127-010 Detector removal tool without pole

Agency Listings and Approvals Product Line Information


Listing and approval below apply to the modules specified HM-PSE-UL: Addressable photoelectric detector; B501
in this. In some cases, certain modules may not be base included
listed by certain approval agencies, or listing may be in
process. Consult factory for latest listing status.

• UL Listed: S36216

Honeywell Building Technologies ASEAN Honeywell Building Technologies META


Level 25, UOA Corp Tower B, Avenue 10 Emaar Business Park, Building 2, 2nd Floor
The Vertical, Bangsar South City Sheikh Zayed Road
59200, Kuala Lumpur, Malaysia P.O.Box 232362, Dubai, U.A.E.
Email: [email protected] Phone: +971 4 4505 847

Honeywell Building Technologies India


Unitech Trade Centre, 5th Floor
Sector – 43, Block C, Sushant Lok Phase – 1
Gurgaon – 122002, Haryana, India
Email: HoneywellSecurity&[email protected]
Toll Free: 1-800-103-0339 HM-PSE-UL-DS | Rev 01 | 08/19
www.honeywell.com © 2019 Honeywell International Inc.
Multi-Sensing Detector

HM-PTSE-UL
General
The HM-PTSE-UL detector is an intelligent, addressable, multi-sensing,
low-profile detector designed for Fire Alarm Control Panels.

The detector uses a combination of photoelectric and thermal


sensing technologies to reduce to false alarms. Unlike traditional
intelligent detectors, it has a microprocessor that processes alarm
Product Photo on White Background
data. As a result, the detector adjusts its sensitivity automatically,
without operator intervention or control panel programming.

Areas where the detector is especially useful include office complexes,


schools, college campuses, manufacturing, and industrial facilities,
HM-PTSE-UL
and anywhere else where the use of a particular area may change.
The detector automatically adjusts its sensitivity to the environment.
NOTE: Avoid installing these detectors in locations that
are susceptible to rapid and high temperature changes.
An example of an incorrect application would be near
Installation or in line with the output of a self-contained heater.

The HM-PTSE-UL plug-in detector uses a separate base to


simplify installation, service, and maintenance. A special tool
allows maintenance personnel to plug-in and remove detectors
without using a ladder. Suitable mounting base boxes include:

• 4.0” (10.16 cm) square box


• 3.5” (8.89 cm) or 4.0” (10.16 cm) octagonal box
• Single-gang box (except relay or isolator base)

F E AT U R E S & B E N E F I T S

• Automatically adjusts sensitivity • Addressing: • Constructed of off-white,


levels without operator -- Addressable by device fire-resistant plastic, designed
intervention or programming -- Rotary, decimal addressing: to commercial standards, and
• Sensitivity increases with heat 1- 159 for models SMX and STX offers an attractive appearance
• Microprocessor-based, combination • SEMS screws for wiring of
• Addresses can be viewed and changed
photo and thermal technology the separate base
without electronic programmers
• Addressable-analog communication • Several base options, including
• Dual bi-color LED design
relay, isolator, and sounder
• Sleek, low-profile design provides 360° viewing angle
• Built-in functional test switch
• Two-wire SLC connection • LEDs lock red when in alarm.
activated by external magnet
• Built-in, tamper-resistant feature
• Listed to UL 268
HM-PTSE-UL Technical Specifications

TECHNICAL SPECIFICATIONS ELECTRICAL SPECIFICATIONS

Parameter Specification Parameter Specification


Sensitivity Voltage range 15 – 32 volts DC peak
1, 2, and 4%/ft with classic CLIP systems
fixed-sensitivity levels
Standby current
300 A
• 2.0” (53 cm) height, base determines daimete (max. avg.)
Size
• B501: 4.1” (10.4 cm) diameter
50 ohms maximum; varies according to control panel
Loop resistance
Shipping weight 5.2 oz (147g) used. Refer to panel installation manuals
Operating temperature 0°C to 38°C (32°F to 100°F) LED current (max.) 6.5 mA @ 24 VDC (“ON”)
0 – 4000 ft./min. (1219.2 m/min.), suitable for
UL-Listed velocity range
installation in ducts
Relative humidity 10% – 93% non-condensing
Thermal sensing rating fixed-temperature setpoint 135°F (57°C)

ACCESSORIES

SMB600 Surface mounting kit


M02-04-00 Test magnet
M02-09-00 Test magnet with telescoping handle
XR2B Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applications
T55-127-010 Detector removal tool without pole
XP-4 Extension pole for XR2B. Comes in three 5-foot (1.524m) sections

Agency Listings and Approvals Product Line Information


Listing and approval below apply to the modules specified HM-PTSE-UL: Low-profile, intelligent, multi-sensor detector
in this. In some cases, certain modules may not be
listed by certain approval agencies, or listing may be
in process. Consult factory for latest listing status.

• UL Listed: S36216

Honeywell Building Technologies ASEAN Honeywell Building Technologies META


Level 25, UOA Corp Tower B, Avenue 10 Emaar Business Park, Building 2, 2nd Floor
The Vertical, Bangsar South City Sheikh Zayed Road
59200, Kuala Lumpur, Malaysia P.O.Box 232362, Dubai, U.A.E.
Email: [email protected] Phone: +971 4 4505 847

Honeywell Building Technologies India


Unitech Trade Centre, 5th Floor
Sector – 43, Block C, Sushant Lok Phase – 1
Gurgaon – 122002, Haryana, India
Email: HoneywellSecurity&[email protected]
Toll Free: 1-800-103-0339 HM-PTSE-UL | Rev 01 | 08/19
www.honeywell.com © 2019 Honeywell International Inc.
Annunciator

315-040
LED Driver Module

General
The 315-040 is an LED driver module that can be used in a wide
variety of applications including as an interface with the Fire Alarm
Control Panel (FACP) to drive most customized graphic annunciators.
It comes in a plastic enclosure that may be mounted inside a custom
annunciator or accessory cabinet and can drive up to 40 LEDs.

The 315-040 and the FACP communicate over a two-


wire serial interface employing the RS485 Repeater-Bus
communication format. An additional two wires are used for
24-volt DC power. A single four-conductor unshielded cable
may be used for both power and data communications.

Up to eight RS485 Repeater-Bus devices may be


connected to the RS485 Repeater-Bus of each FACP.

K E Y F E AT U R E S
• 315-040 connects to the Repeater- • Compatible with Honeywell Morley • Up to eight Repeater-Bus
Bus terminal on the FACP and STX and SMX fire panel models devices may be connected to the
requires minimal programming Repeater-Bus of each FACP
• Can be remotely located up to 6,000
• Each 315-040 module feet (1,829 m) from the panel
drives up to 40 LEDs
• May be powered by 24 VDC from
• Programmable to indicate the host FACP or by remote power
activity for points or zones supply (requires 24 VDC)
315-040 Technical Specifications
Maximum Repeater-Bus Voltage 24 VDC

Maximum Current Alarm: 200 mA, Standby: 35 mA, Each LED: 10mA

Maximum wiring distance from FACP 6000 ft. (1829 m.)

Ambient Temperature 32ºF to 120ºF (0ºC to 49ºC)

Relative Humidity 93% ± 2% RH (non-condensing) at 32ºC ± 2ºC (90ºF ± 3ºF)

For use indoors in a dry location

Connections to FACP power-limited and supervised

External measurements 6.00” (15.2 cm.) high x 7.76” (19.7 cm.) wide x 1.46” (3.7 cm.) deep

Agency Listings and Approvals


The listings and approvals below apply to the 315-040. In some cases,
certain modules may not be listed by certain approval agencies, or listing
may be in process. Consult factory for latest listing status.
• UL Listed: S36108

The Repeater-Bus:
• Powering the devices on the repeater-bus from auxilIary power supply
Repeater-bus devices can be powered by an auxiliary power supply when
available panel power is exceeded. See facp manual for information.

• Repeater-Bus device addressing


Each Repeater-Bus device requires a unique address (ID number) in order to
communicate with the facp. A maximum of eight devices can be connected to the
FACP Repeater-Bus communication circuit. See the facp manual for more information.

For more information


www.morley-ias.co.uk

Honeywell Building Technologies ASEAN Honeywell Building Technologies META


Level 25, UOA Corp Tower B, Avenue 10 Emaar Business Park, Building 2, 2nd Floor
The Vertical, Bangsar South City Sheikh Zayed Road
59200, Kuala Lumpur, Malaysia P.O.Box 232362, Dubai, U.A.E.
Email: [email protected] Phone: +971 4 4505 847

Honeywell Building Technologies India


Unitech Trade Centre, 5th Floor
Sector – 43, Block C, Sushant Lok Phase – 1
Gurgaon – 122002, Haryana, India
Email: HoneywellSecurity&[email protected]
Toll Free: 1-800-103-0339 LED Driver Module | Rev 01 | 08/19
www.honeywell.com © 2019 Honeywell International Inc.
dn-60245:A

ExitPoint™
Directional Sounder
with Voice Messaging
Audio/Visual Devices

General
The ExitPoint™ Directional Sounder has an integral audio ampli-
fier that produces a pulsating sound consisting of broadband
low, mid, and high range sounds. The broadband noise makes it
possible to determine the location of the sound. There are four
pulse patterns that can be used to create an egress pathway out
of a building and to mark perimeter exits. In addition to the
broadband noise, the sounder is capable of playing an alert
message in the form of a recorded voice message or other audi-
ble signals. These messages will instruct the occupants of what
action to take as they approach the directional sounder, and will
allow them to react quickly and confidently when the sounder is
activated. Fifteen different language combinations are available
to instruct occupants that they are nearing an exit, a stairway up,
a stairway down, or an area of refuge. The directional sounder
also incorporates an optional disable feature for use in conjunc-
tion with a control module or heat sensor.
The directional sounder features a number of field selectable
7044pho1.jpg
power settings including high, medium-high, medium-low, and
low. Installation ease and pleasing aesthetics are achieved by a
low profile compact design, and by the ability to flush mount in a
4” x 4” x 2¼” back-box.
ExitPoint directional sounders, fitted in addition to normal build-
ing evacuation sounders, draw people to evacuation routes in
both good and poor visibility. The directional sounder can be
Additional Tone Selection
used in a wide range of building applications. Trials consistently
Switch Switch
have shown an improvement of up to 75 percent in evacuation Position 5 Position 6 Sound Output
times in smoke and up to 35 percent without smoke. The 2007 Setting Setting
Edition of NFPA 72 now provides installation and maintenance
guidelines on directional sounders. On On Area of Refuge
On Off Upstairs
Features Off On Downstairs
• Listed to UL 464 (indoor applications only) Off Off Exit Here
• Five field-selectable power settings
• Four field-selectable routing evacuation patterns Enable/Disable Selection
• Constructed to be effective in unfamiliar surroundings or
poor visibility Switch
• Designed to work in open areas, corridors, or stairs
Position 4 Terminals 3 & 4 Sound Output
Setting
• Fifteen different language selections available
On Open Disabled
• Reduces evacuation times by as much as 75 percent
On Closed Enabled
• Optional disable feature for use in conjunction with a control
module or heat sensor Off Open Enabled
• Low profile, compact design Off Closed Disabled

Specifications Power Setting Guide


ELECTRICAL SPECIFICATIONS DIP Switch DIP Switch DIP Switch
Voltage Input: Regulated 24 Volts Power
Position 1 Position 2 Position 3 Setting
Operating Voltage Range: 16 to 33 Volts Setting Setting Setting
Operating Temperature: 32°F to 120°F (0°C to 49°C) Off Off Off High
On Off Off Med-High
Power Setting: High, medium-high, medium, medium-low, low
Off On Off Med
MECHANICAL SPECIFICATIONS Off Off On Med-Low
Input Terminals: 12-24 AWG On On On Low
Speaker Size: 4” (101 mm)
Grille Size: 4 7/8” (127 mm)

dn-60245:A • 12/10/08 — Page 1 of 2


Current Draw Measurements and Sound Output Guide
Max DC
DIP Switch Power Operating Audibility Audibility
Speed (dBA) (dBA)
Selection Setting Current Note 1 Note 2
(mA RMS)
Fast (Exit) 10 High 185 84 75
Fast (Exit) 10 Med-High 131 81 72
Fast (Exit) 10 Med 78 78 69
Fast (Exit) 10 Med-Low 76 75 66
Fast (Exit) 10 Low 64 72 63
Med-Fast 9 High 170 83 74
Med-Fast 9 Med-High 124 80 71
Med-Fast 9 Med 75 77 68
Med-Fast 9 Med-Low 73 74 65
Med-Fast 9 Low 62 71 62
Med-Slow 8 High 135 82 73
Med-Slow 8 Med-High 104 79 70
Med-Slow 8 Med 67 76 67
Med-Slow 8 Med-Low 65 73 64
Med-Slow 8 Low 57 70 61
Slow 7 High 120 82 72
Slow 7 Med-High 92 79 69
Slow 7 Med 62 76 66
Slow 7 Med-Low 61 73 63
Slow 7 Low 54 70 60
Note 1: Sound output measured in anechoic room at 10 feet.
Note 2: Sound output measured in a reverberant room at 10 feet.

Language/Audible Tone Selection Guide


Rotary Switch Selection Tone/Language
0 Audible tone/sweep 8 Mandarin
1 English 9 English/Cantonese
2 Spanish 10 English/Mandarin
3 French 11 Cantonese/Mandarin
4 English/Spanish 12 English/Korean
5 English/French 13 English/Portuguese
6 Korean 14 English/Russian
7 Cantonese 15 English/Polish

Agency Listings and Approvals Ordering Information


Consult product manual for lists of compatible UL-Listed PF24V ExitPoint Directional Sounder with Voice
devices. In some cases, certain modules may not be listed by Messaging
certain approval agencies, or listing may be in process. Con-
BBS-SP201W Surface mount backbox skirt for PF24V
sult factory for latest listing status.
• UL Listed: S4011
• FM Approved
• CSFM: 7135-1653:175
• MEA Approved: 492-04-E Vol. 2

ExitPoint™is a trademark of Honeywell International Inc.


©2008 by Honeywell International Inc. All rights reserved. Unauthorized use
of this document is strictly prohibited.

This document is not intended to be used for installation purposes.


We try to keep our product information up-to-date and accurate.
We cannot cover all specific applications or anticipate all requirements.
All specifications are subject to change without notice.
Made in the U.S. A.
For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118.
www.notifier.com

Page 2 of 2 — dn-60245:A • 12/10/08


Annunciator

315-080
80-Character Serial LCD Annunciator

General
The 315-080 annunciator is a compact, backlit, 80-character LCD fire
annunciator that mimics the Fire Alarm Control Panel (FACP) display.
It provides system status indicators for AC Power, Alarm, Trouble,
Supervisory, and Alarm Silenced conditions. The 315-080 and the FACP
communicate over a two-wire serial interface employing the Repeater-Bus
communication format. Connected devices are powered, via two additional
wires, by either the host FACP or a remote UL-listed, filtered power supply.

The 315-080 displays English-language text of system point


informa-tion including device type, zone, independent point alarm,
trouble or supervisory status, as well as any custom alpha labels
programmed into the control panel. It includes control switches
for remote control of critical system functions. (A keyswitch
prevents unauthorized operation of the control switches.)

Up to eight 315-080 repeaters may be connected to the


Repeater-Bus of each FACP. No programming is required,
which saves time during system commissioning.

Controls and Indicators


• AC Power
• Alarm
• Supervisory
• Alarm Silenced
• Trouble

K E Y F E AT U R E S
• Listed to UL Standard 864, 9th Edition • Enclosure supervised for tamper • Surface mount directly to wall or to
single, double, or 4” square electrical box
• Backlit 80-character LCD display • System status LEDs for AC Power,
(20 characters x 4 lines) Alarm, Trouble, Supervisory, • Semi-flush mount to single, double,
and Alarm Silence or 4” square electrical box. Use ANN-
• Mimics all display information
SB80KIT for angled view mounting
from the host panel • Local sounder can be enabled
or disabled at the FACP • Can be remotely located up to 6,000
• Control switches for System
feet (1,800 m) from the panel
Acknowledge, Signal Silence, and Reset • 315-080 connects to the Repeater-
Bus terminal on the FACP and requires • Backlight turns off during AC loss to
• Control switches can be independently
minimal panel programming conserve battery power but will turn
enabled or disabled at the FACP
back on if an alarm condition occurs
• Displays device type identifiers,
• Keyswitch enables/disables
individual point alarm, • May be powered by 24 VDC from
control switches and mechanically
trouble, supervisory, zone, the host FACP or by remote power
locks annunciator enclosure
and custom alpha labels supply (requires 24 VDC)
• Keyswitch can be enabled
• Time and date display field • Up to eight 315-080 repeaters can be
or disabled at the FACP
connected on the RS485 Repeater-Bus
315-080 Technical Specifications
Operating voltage range 18 VDC to 28 VDC

Current consumption @ 24 VDC nominal (filtered and non resettable): 40 mA maximum

Ambient temperature 32°F to 120°F (0°C to 49°C)

Relative humidity 93% ± 2% RH (non-condensing) at 32°C ± 2°C (90°F ± 3°F)

Dimention 5.375” (13.65 cm.) high x 6.875” (17.46 cm.) wide x 1.375” (3.49 cm.) deep

For use Indoors in a dry location

Connections All connections are power-limited and supervised

The Repeater-Bus: • Wire Requirements: Power Circuit


• Powering the devices on the Repeater- -- 14 to 18 AWG (0.75 - 2.08 mm2) wire for 24
Bus from auxiliary power supply VDC power circuit is acceptable. Power wire
The Repeater-Bus can be powered by an auxiliary power distance limitation is set by 1.2 volt maximum
supply when the maximum number of Repeater-Bus line drop form source to end of circuit.
devices exceeds the Repeater-Bus power requirements. -- All connections are power-limited and supervised.
See the FACP manual for more information. -- A maximum of eight 315-080 repeater
modules may be connected to this circuit.
• Repeater-Bus Device Addressing
Each Repeater-Bus device requires a unique address
(ID Number) in order to communicate with the Agency Listings and Approvals
FACP. A maximum of 8 devices can be connected The listings and approvals below apply to the 315-
to the FACP Repeater-Bus communication circuit. 040. In some cases, certain modules may not be listed
See the FACP manual for more information. by certain approval agen-cies, or listing may be in
process. Consult factory for latest listing status.
• Wire Requirements: Communications Circuit
The 315-080 connects to the FACP Repeater-Bus • UL Listed: S36108
communications cir-cuit. To determine the type of
wire and the maximum wiring distance that can be Ordering Options
used with FACP Repeater-Bus accessory modules, it • 315-080: Red 80 character LCD Annunciator
is necessary to calculate the total worst case current
draw for all modules on a single 4-conductor bus. The
total worst case current draw is calculated by adding
the individual worst case currents for each module.
NOTE: For total worst case current draw on a single
Repeater-Bus refer to appropriate FACP manual.

For more information


www.morley-ias.co.uk

Honeywell Building Technologies ASEAN Honeywell Building Technologies META


Level 25, UOA Corp Tower B, Avenue 10 Emaar Business Park, Building 2, 2nd Floor
The Vertical, Bangsar South City Sheikh Zayed Road
59200, Kuala Lumpur, Malaysia P.O.Box 232362, Dubai, U.A.E.
Email: [email protected] Phone: +971 4 4505 847

Honeywell Building Technologies India


Unitech Trade Centre, 5th Floor
Sector – 43, Block C, Sushant Lok Phase – 1
Gurgaon – 122002, Haryana, India
Email: HoneywellSecurity&[email protected]
Toll Free: 1-800-103-0339 Serial LCD Annunciator DS | Rev 01 | 08/19
www.honeywell.com © 2019 Honeywell International Inc.

You might also like