The SharpFlow is a static meter electromagnetic type, battery powered with 15 years life time.
Available from D25 up to DN300, the electronic register is available in compact or remote version.
Its IP68 design allows installation in places where flooding can occur, or completely buried
underground. The SharpFlow is designed for custody transfer according to European Directive MI-
001.The measuring accuracy reflects the most recent specifications of the ISO/EN, MI-001 and OIML
standards.
SharpFlow measuring tube has a FEATURES AnD BEnEFITS Bulk water / revenue metering
smooth shape. This unique design, » Unique flow sensor design for limited To ensure water bills are fair, and to
consisting of a rectangular cross section; pressure loss reduce the need for verification, usage
optimized stainless steel electrodes must be measured cost effectively and
» Battery lifetime up to 15 years
and a homogeneous magnetic field, accurately.
forms the basis for a flow-optimizing » IP 68, Maintenance-free
With high turndown ratio, energy-saving
cross section, and thereby provides » High accuracy, repeatability
low pressure drop, and certification to
reliable measurements that are largely » Compatible with AMR boards global revenue standards, the SharpFlow
independent of the flow profile. The
» MID MI-001 & OIML R49 certifications measures flow with consistently high
measuring chamber is made of Rilsan®
» Available from D25 up to DN300 accuracy over a wide range of flow rates.
and is resistant to corrosion, aging
Irrigation
and abrasion. As a result, SharpFlow
Distribution and abstraction Where irrigation systems are used in crop
is compatible with drinking water and
complies with all regulations for water, Flow can be measured in both directions production, SharpFlow ensures water
waste water industries. with the same degree of accuracy. wastage is kept to a minimum and that
Furthermore, reliable and repeatable farmers get a fair deal.
measurements of low flow at night aid in The SharpFlow has no moving parts and
early leakage detection. is not prone to wear and tear in the usual
way. It is resistant to solids and debris in
the water supply.
- IP 68 Converter
- Battery Lifetime
- MID Approuved
IP 68 convector output
Rectangular cross section connection to AMR
- Calculations on flow profile behaviour systems
demonstrate: SharpFlow has a - WaterMind
superior uniform flow profile, also with - EverBlu
disturbances - AnyQuest
- No internal moving parts
- Smooth liner
- Insensitive to water quality & impurities
(sand, minerals, iron, etc)
- Not sensitive to spinning or jetting
- No possible blocking of meter
- No filters / strainers required
Rilsan coating
- Durable and maintenance-free
- High chemical & corrosion resistance
- High abrasion resistance
- Temperature range: -5 to 70°C
- Flexible and tough
- Smooth and pore-free minerals
prevented from sticking
- Free of solvents
- Widely accepted by W&WW industry
- Green (100% based on renewable
resources)
ACCURACY / PERFORMAnCE
Y [%] 1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0 1 2 3 4 5 6 7 8 9 10 11 12 X [m/s]
Industrial use
Residential
Water intake
Pumping station
Sedimentation
Coagulation
Measuring system compatible with Itron AMR solutions
Measuring principle Faraday’s law of induction
Application range Electrically conductive fluids
Measured value
Primary measured value Flow velocity
Secondary measured value Volume flow
Measurements
Measuring units Volume flow
Standard: m3
Optional: US Gallons
Flow rate
Standard: m3/ hr
Optional: USGPM
Measurement frequency Standard: 15s (1 measurement per 15 seconds)
WaterMind
Optional: 1s, 10s, 20s
Empty pipe detection Optional: Display shows – EP – in case of empty pipe detection
Secondary measured value Volume flow
Measuring accuracy
Reference conditions Flow condition: similar to EN290104
Medium: water
Electrical conductivity: > 300 μS/cm
Temperature: 20 0C / 68 0F
Operating pressure / 14.5 psig
Maximum measuring error Down to 0,2% of the measured value ± 0.5 mm/s
Repeatability DN 25…300: ±0.1% (v > 0.5 m/s / 1.5 ft/s)
Calibration / Verification Standard: Each meter is calibrated before leaving the factory.
Optional: Verification to Measurement Instrument Directive (MID),
Annex MI-001
Temperature
Process temperature Refer to the technical datasheet of SharpFlow
Ambient temperature -40 …. to +65 0C / -40 …. to +149 0F
Ambient temperatures below - 25 0C / -13 0F may affect the
readability of the display.
It is recommended to protect the converter from external heat AnyQuest / EverBlu Pulse Enhanced
sources such as direct sunlight because high temperatures reduce
the lifecycle of all electronic components.
Storage temperature 50 …. to +70 0C / -58 …. to +158 0F
Pressure
Medium Refer to the technical datasheet of SharpFlow
Chemical properties
Phyisical conditions Water: Drinking water, raw water, irrigation water
Electrical conductivity ≥20 μS/cm
Other conditions
Protection category C (compact version) in plastic housing: IP68 (NEMA 4X/6P)
C (compact version) in aluminium housing: IP66/67 (NEMA 4/4X/6)
F (remote version) in aluminium housing: IP66/67 (NEMA 4/4X/6)
F (remote version) IP68 (NEMA 4X/6P) flow sensor (remote
electronic converter)
EverBlu Collector
Our company is the world’s leading provider of smart metering, data collection and utility software systems, with over
8,000 utilities worldwide relying on our technology to optimize the delivery and use of energy and water.
To realize your smarter energy and water future, start here: www.itron.com
While Itron strives to make the content of its marketing materials as timely and accurate as possible, Itron makes no claims, promises, or guarantees about the accuracy, completeness,
or adequacy of, and expressly disclaims liability for errors and omissions in, such materials. No warranty of any kind, implied, expressed, or statutory, including but not limited to
the warranties of non-infringement of third party rights, title, merchantability, and fitness for a particular purpose, is given with respect to the content of these marketing materials.
© Copyright 2011, Itron. All rights reserved. WA-0085.1-EN-10.11