Explorer Plus

Electronic Volume Conversion Device

Electronic Volume Conversion Device Explorer Plus

Description
Explorer Plus is the new EVCD by Pietro Fiorentini SpA designed to optimize installation and maintenance, it meets the most recent regulations and maintains compatibility with existing Explorer Family product and accessories. Easy Installation: external sensors make installation easy and fast saving time and money. Reduced Maintenance: longer battery life and battery replacement optimization make maintenance activities less frequent and shorter. Backward compatibility with Explorer FT: save existing investments using same protocol and ancillary equipments of existing installations. Long Life Investment: MID (2004/22/CE) approval makes it ideal for long term investment. Ready to groove: large memory capability allow easy upgrade, also on installed device, in order to meet new regulations or new needs.

Designed On your Needs:

High value for money Excellent MTBF Extended battery life Easy installation MID approved for custody transfer application Five Years Warranty
Explorer Plus

TECHNICAL SPECIFICATIONS
Environmental Working Temperature Interface Dimension Mounting Pressure (external - 3m cable) Ranges Accuracy Temperature (PT1000 class A - 4 wires) Range Accuracy Overall Accuracy

Explorer Plus

-25C ~ +60C 2 x 16 Display ~ 4 keys 155 x 182 x 82 mm ~ IP65 (EN60529) Pole or Wall mounting in Hazardous area 3,5 ~ 10 bar (absolute) 0,25% @ reference conditions 30% ~ 100% FS -20C ~ +50C 0,3C @ 0C (@ reference conditions) 0,5% (0,35% typical) @ reference cond. 1% (0,70% typical) @ operating cond.

Digital Inputs/Outputs Counting Status Digital Outputs Communication Serial for ancillary equipment Optical Port Serial RS232 Protocols Power Supply Battery External Backup Battery Formulas Volume at base conditions Compressibility AGA 7 AGA-NX 19mod ISO 12213-3: 1997 (SGERG91) AGA 8 gross 1 and gross 2 Logging Data Logging Events and Alarms Approvals Atex MID 2004/22/CE IMQ 08 ATEX 030 CH-MI002-09001-00 1MB - up to 65535 records Period from 15 minutes up to 8 hours Average and Statistics strategies 10000 records Lithium 3,6V - 16Ah - size D battery life 7,5 years (EN12405) 20mA @ 5 ~ 6 VDC from ancillary device battery life 50 stand-by cycles Proprietary current loop for communication with ancillary equipments ZVEI (IEC1107) RS232 on DB9F (optional) Modbus SNAM UNI-TS 11291 LF - 3Hz with 50ms minimum pulse width 1 digital input for status monitoring 3 digital outputs for signal repetition

Pietro Fiorentini Solutions

Service

Gas meters

Metering systems

Pietro Fiorentini S.p.A. via E.Fermi 8/10 I-36057 Arcugnano (VI) Italy

Tel. +39 0444 968.511 Fax. +39 0444 960.468

The data are not binding. We reserve the right to make eventual changes without prior notice.

CT-s 554-E July 10

www.fiorentini.com