Wheelock

2009/2010 Product Catalog


Fire & Security Notification Appliance and Devices
Explosion Proof & Hazardous Location Signals
Emergency Communication Systems and Accessories
Customer Service: (800) 631-2148, Option #2
Technical Support: (800) 631-2148, Option #3
Inside Sales/Marketing Support: (800) 631-2148, Option #4
Literature Request: (800) 631-2148, Option #7

About Cooper Notification


Cooper Notification, a solution platform of The Cooper Safety Division, is comprised of several businesses with decades
of experience and innovation in the development of high quality products and solutions. With the ever present need to
protect, alert and inform, Cooper Notification is focused on meeting the growing demand for personnel and property
safety. We are the source for notification solutions supporting Fire, Security, Hazardous area, Mass Notification, Voice
evacuation and Industrial Signaling applications and operating under the powerful global brands of Fulleon, MEDC, Roam
Secure, SAFEPATH, WAVES and Wheelock. For more information, visit the web site at www.coopernotification.com.
Table of Contents

Fire & Security Notification Appliances and Devices


4 Wheelock Exceder Strobes, Horns & Horn Strobes
6 Wheelock Horns and Horn Strobes
10 Wheelock Strobes, Chimes & Chime Strobes
11 Wheelock Bells
14 Wheelock Weatherproof Appliances and Mounting Accessories
18 Wheelock Speakers & Speaker Strobes
22 Wheelock Supervised Horns and Cluster Speakers
24 Wheelock Power Supplies and Sync Modules
26 Wheelock Pull Stations and Accessories
28 Wheelock Security Signaling Devices
32 Approvals Listings
34 Wheelock Mounting

Explosion Proof & Hazardous Location Signals


40 MEDC Strobes and Warning Lights
44 MEDC Horns, Speakers, Combo Units, Call Points
45 Wheelock Bells & Relays

Emergency Communication Systems


50 SAFEPATH System and Accessories
54 Wheelock Colored Lens Appliances for Mass Notification Signaling
TM

1 Model Number
Wall - 15/1575/30/75/95/110/135/185; Ceiling - 15/30/60/75/95/115/150/177
Horn Strobes
Industry’s lowest current draw with 12/24 VDC operation in one appliance HSR
HSW
Voltage test points for quick troubleshooting and easy spot checking - on wall
HSRC
models
HSWC
Prewire capability to check for wiring & ground faults prior to appliance installation Strobes
STR
5 Mounting Options - 1 gang, 2 gang, 4”sq., 3.5 octal, 4” octal box
STW
Contact cover provides protection from dirt, dust, paint and accidental damage, STRC
and allows for prewire testing and troubleshooting STWC Model Legend
Horns HN = Horn
HNR ST = Strobe
6.65 2.64 1.32

HNW HS = Horn Strobe


C = Ceiling Mount
HNRC
W = White
HNWC R = Red
STRC = Strobe, Red, Ceiling Mount
HSR = Horn Strobe, Red, Wall Mount
HSW = Horn Strobe, White, Wall Mount
*UMB Contact Cover

Voltage test points for quick 8 candela settings Common base for wall and ceiling with 5
troubleshooting and easy spot mounting options
checking (wall models only)

6.65 2.64 1.32

See approvals chart on page 32 for approvals by model.


4
Strobes, Horns and Horn Strobes

Exceder is also available with metallic face plate.


Silver Horn Strobe Silver Horn Silver Strobe
HSRS HNRS STRS
HSWS HNWS STWS
HSRCS HNRCS STRCS
HSWCS HNWCS STWCS

Horn Strobe Ratings per UL 1971 & UL 464 at 24 VDC


UL Max Current* at 99 dBA
24 VDC 12 VDC
Regulated Voltage
Model 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75
Range VDC
HS 8.0-33.0 0.082 0.095 0.102 0.148 0.176 0.197 0.242 0.282 0.125 0.159
HSC 8.0-33.0 0.082 0.102 0.141 0.148 0.176 0.197 0.242 0.282 0.125
UL Max Current* at 95 dBA
24 VDC 12 VDC
Regulated Voltage
Model 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75
Range VDC
HS 8.0-33.0 0.073 0.083 0.087 0.139 0.163 0.186 0.230 0.272 0.122 0.153
HSC 8.0-33.0 0.073 0.087 0.128 0.139 0.163 0.186 0.230 0.272 0.122
UL Max Current* at 90 dBA
24 VDC 12 VDC
Regulated Voltage
Model 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75
Range VDC
HS 8.0-33.0 0.065 0.075 0.084 0.136 0.157 0.184 0.226 0.267 0.120 0.148
HSC 8.0-33.0 0.065 0.084 0.120 0.136 0.157 0.184 0.226 0.267 0.120

Horn Ratings per UL 464


Regulated Voltage Exceder Cross Reference Chart is available on page 33.
Model 99 dB 95 dB 90 dB
Range VDC
HN 16-33.0 0.064 0.044 0.022
HNC 16-33.0 0.084 0.044 0.022
HN 8.0-17.5 0.047 0.026 0.017
HNC 8.0-17.5 0.047 0.026 0.017
1 2 3 4
1. Series ZNS & ZNH 2 3. Series AS & AH 2
• Easy snap on base • 2 wire applications
• 2 selectable dBA settings (90 and 95) • 3 selectable dBA settings (90, 95, 99)
• Designed to simplify installation and testing Order Codes/Model Numbers Note 3
Order Codes/Model Numbers Note 3 AS AH
ZNS ZNH 9024 AS-24MCW-FR 7892 AH-24-R
0304 ZNS-MCW-FR 0301 ZNH-W 9025 AS-24MCW-FW 7893 AH-24-W
0305 ZNS-MCW-FW 0300 ZNH-R 3162 AS-24MCC-FW
0311 ZNS-MCC-FW 3161 AS-24MCC-FR
0310 ZNS-MCC-FR

4. Series HS4 & HS 2


2. Series NS & NH 2 • 2-4 wire applications
• 3 selectable dBA settings (99, 95, 90)
• 2 wire applications
• 2 selectable dBA settings (90 and 95) Order Codes/Model Numbers 3
• Round models available HS4 HS
Order Codes/Model Numbers 3 3150 HS4-24MCW-FR 3152 HS-24-R
NS NH 3151 HS4-24MCW-FW 3153 HS-24-W
7806 NS-241575W-FR 7449 NH-12/24-R 3176 HS4-241575W-FR
3753 NS-24MCC-FW 7500 NH-12/24-W 6250 HS4-24MCC-FW
3754 NS-24MCC-FR
5. Series MT Multi-tones
General Features and Options: • 4 wire applications
Available Colors: Red or white • 8 selectable alerting sounds
• 2 selectable sound outputs
Mounting: Wall or Ceiling
Order Codes/Model Numbers 3
Standard Backboxes
MT
Strobe/Horn Synchronization 3301 MT-24MCW-FR 5023 MT-12/24-R
Multi-Candela or High Intensity Models 8422 MT-241575W-FR 5024 MT-12/24-W
Approvals Include : UL, ULC, FM, CSFM, MEA, BFP
Note 1 9747 MT-121575W-FW 6142 MT4-115-S
3305 MT-24MCW-FW 6223 MT4-115-R

Note 1: See approvals chart on page 32 for approvals by model. For mounting options, refer to pages 34-39.
6 Note 2: This series of products will be discontinued as of March 2010. For replacement list see page 33.
Note 3: Additional models are available. Contact customer service for more information.
Horns & Horn Strobes

5 6 7 8
6. Series AMT Multi-tones
• 2-8 wire applications
TM
• 3 distinct prioritized audible signals from 3 isolated
inputs
• Ideal for combination fire and burglary and
suppression systems
Order Codes/Model Numbers 3
AMT
9463 AMT-241575W-FR 5887 AMT-12/24-R
3300 AMT-24MCW-FR 7920 AMT-12/24-R-NYC
9466 AMT-241575W-FW 5893 AMT-12/24-W

7. Series MIZ Mini Horn


• High Sound output, low current draw
• Ideal for alarm signaling, in individual rooms,
apartment, hotels and offices

Order Codes/Model Numbers 3


MIZ
5
8485 MIZ-24S-R
8484 MIZ-24S-W

8. Series 31T VAC Horn


Horn Strobes Strobes Horn
• Ideal for high sound output applications
HSR STR HNR
• Low current draw
HSW STW HNW
Order Codes/Model Numbers 3
HSRC STRC HNRC
31T HSWC STWC HNWC
2805 31T-115-R
0521 31T-115-S
Horn Strobe Ratings per UL 1971 & UL 464 at 24 VDC
UL Max Current at 99 dBA
24 VDC 12 VDC
Regulated Voltage
Model(s) 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75
Range VDC

HS (Wall) 8.0-33.0 0.082 0.095 0.102 0.148 0.176 0.197 0.242 0.282 0.125 0.159
HSC (Ceiling) 8.0-33.0 0.082 0.108 0.108 0.156 0.185 0.210 0.245 0.282 0.127
AMT, MT, HS4 (Wall) 16.0-33.0 0.060 0.090 0.092 0.165 0.220 0.300 0.420
0.121
AS (Wall) 16.0-33.0 0.088 0.125 0.200 0.267 0.335 0.460
0.280#
AS (Ceiling) 16.0-33.0 0.095 0.138 0.221 0.285 0.355 0.480
UL Max Current at 95 dBA
24 VDC 12 VDC
Regulated Voltage
Model(s) 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75
Range VDC

HS 8.0-33.0 0.073 0.083 0.087 0.139 0.163 0.186 0.230 0.272 0.122 0.153
HSC 8.0-33.0 0.073 0.093 0.093 0.142 0.163 0.186 0.230 0.272 0.122
0.104
NS, ZNS (Wall) 16.0-33.0 0.074 0.107 0.184 0.244 0.350* 0.477*
0.220#
NS, ZNS (Ceiling) 16.0-33.0 0.082 0.124 0.209 0.275 0.350 0.477
0.107
AS (Wall) 16.0-33.0 0.074 0.110 0.190 0.253 0.340 0.465
0.240#
AS (Ceiling) 16.0-33.0 0.080 0.122 0.201 0.269 0.340 0.465
UL Max Current at 90 dBA
24 VDC 12 VDC
Regulated Voltage
Model(s) 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75
Range VDC

HS 8.0-33.0 0.065 0.075 0.084 0.136 0.157 0.184 0.226 0.267 0.120 0.148
HSC 8.0-33.0 0.065 0.084 0.084 0.136 0.157 0.184 0.226 0.267 0.120
0.096
ZNS, NS (Wall) 16.0-33.0 0.066 0.101 0.177 0.232 0.306* 0.429*
0.210#
NS, ZNS (Ceiling) 16.0-33.0 0.082 0.124 0.209 0.275 0.350 0.477
0.100
AS (Wall) 16.0-33.0 0.068 0.105 0.182 0.245 0.355 0.470
0.225#
AS (Ceiling) 16.0-33.0 0.074 0.113 0.198 0.263 0.355 0.470

*High Candela (135, 185) not an option for NS wall models Series 31T
#Current at 8-17.5 VDC for NS or AS Models UL Max. 115 VAC dBA @ 10 ft. 4.00 2.61
Current 0.160 87
UL Max Current - Audible
16.0-33.0 VDC 8.0-17.5 VDC
Model(s) (99) dBA (95) dBA (90) dBA (99) dBA (95) dBA (90) dBA

HS4 0.110 0.068 0.027 4.00

NS 0.044 0.018 0.021 0.012


AS 0.080 0.043 0.021 0.192 0.108 0.058
LONG

8
Specifications
Horns & Horn Strobes

Series MT Multi-tones dBA @ 10 ft. (UL dBA @ 10 ft. dBA @ 10 ft. (UL
Audible Ratings Reverberant) (anechoic) Reverberant)
8-17.5 and
UL Max. Current 16-33 VDC 8-17.5 VDC 120 VAC dBA 16-33 VDC 8-17.5 VDC 120 VAC
16-33 VDC
HI Out STD Out HI Out STD Out HI Out STD Out HI STD HI STD HI STD HI STD
Out Out Out Out Out Out Out Out
Horn 0.108 0.044 0.177 0.034 0.050 0.042
Horn 92 87 92 87 99 93 88 82
Bell 0.053 0.024 0.095 0.020 0.041 0.039
March Time Bell 86 80 86 80 92 87 82 75
0.104 0.087 0.142 0.034 0.050 0.040 March Time
Horn 89 84 89 84 99 93 85 79
Code-3 Horn 0.091 0.035 0.142 0.034 0.050 0.042 Horn
Code-3 Horn 88 83 88 83 99 93 85 75
Code-3 Tone 0.075 0.035 0.105 0.021 0.042 0.040
Code-3 Tone 85 80 85 80 95 90 79 75
Slow Whoop 0.098 0.037 0.142 0.035 0.050 0.042
Slow Whoop 90 85 90 85 99 94 88 82
Siren 0.104 0.036 0.152 0.030 0.045 0.041
Siren 89 84 89 84 98 93 85 82
Hi/Lo 0.057 0.025 0.114 0.026 0.042 0.039
Hi/Lo 86 81 86 81 93 88 82 79
Series AMT Multi-tones Series MIZ
Series AS/AH
16-33 VDC 8-17.5 VDC Reverberant dBA Per UL
Anechoic dBA @ 10 ft 464 @ 10 ft 
HI Out STD Out HI Out STD Out
Continuous Code 3 Continuous Code 3
Horn 0.108 0.043 0.210 0.058 24 VDC
Bell 0.057 0.026 0.117 0.031 87 87 83 78
March Time
0.108 0.035 0.210 0.059 UL Max. Current
Horn 2.75 1.28
Code-3 Horn 0.108 0.043 0.210 0.057 1.12 16-33 VDC 0.026


Code-3 Tone 0.060 0.030 0.168 0.052
Slow Whoop 0.112 0.044 0.182 0.056
Siren 0.102 0.038 0.177 0.055
Hi/Lo 0.064 0.030 0.131 0.028 4.50

1.68
Vibrating Chime 0.041 0.020 0.090 0.028

Series AMT/MT/HS 4.352 4.80


2.

Series NS Series Z
 

4.75 2.38
5.126 4.80



4.75

5.126
4.80
2.54
&)2% !,!2- $%6)#% $/ ./4 0!).4



  

5.13
2.17 4.80
&)2% !,!2- $%6)#% $/ ./4 0!).4



5.13

&)2% !,!2- $%6)#% $/ ./4 0!).4


Strobes, Chimes & Chime Strobes

1 2 3
1. Series RSS & RSSP Strobes 2. Series ZRS Strobes Note 2
• Provide wide range of intensities • Easy snap on base
• Strobe plates for retrofitting existing audible • Designed to simplify installation and testing
notification appliances to strobe applications
Order Codes/Model Numbers 3
Order Codes/Model Numbers 3
ZRS
RSS RSSP 4085 ZRS-MCW-FR
9400 RSS-24MCW-FR 9402 RSSP-24MCW-FR 0302 ZRS-MCW-FW
9401 RSS-24MCW-FW 3308 RSSPA-24MCC-NW 0309 ZRS-MCC-FW
3158 RSS-24MCC-FW Colored Lens 0308 ZRS-MCC-FR
3157 RSS-24MCC-FR 0202 RSSA-24MCC-NW
3160 RSS-24MCCR-FW 8179 RSSR-2475C-AAW
7471 RSS-241575W-FR 8196 RSSR-2475W-AAW
3. Series CH Chimes
7788 RSS-241575W-FW
• Ideal for hospital and institutional applications
• Single stroke or vibrating operation
• Replaceable grills

Order Codes/Model Numbers 3


CH70 CH90
9018 CH70-24MCW-FR 3168 CH90-24MCC-FW
General Features and Options:
9019 CH70-24MCW-FW 3167 CH90-24MCC-FR
Available colors: Red or white
7825 CH70-24-R 7828 CH90-24-W
Mounting: Wall or ceiling 7830 CH70-241575W-FR
Standard backboxes
Strobe/horn Synchronization
Multi-Candela or High Intensity models
Approvals include Note 1: UL, ULC, FM, CSFM, MEA, BFP
Wall intensities: 15, 30, 75, 110cd or 135/185cd
Ceiling Intensities: 15, 30, 75, 95cd or 115/177cd

Note 1: See approvals chart on page 32 for approvals by model. For mounting options, refer to pages 34-39.
10 Note 2: This series of products will be discontinued as of March 2010. For replacement list see page 33.
Note 3: Additional models are available. Contact customer service for more information.
Bells

4 5 6
4. Series MB Motor Bell 6. Series CVX/CSX Explosion Proof Bell
• Available in 6” & 10” • Listed for Service in Division 1
• Strobe synchronization with RSSP strobe plate applications
• Indoor or outdoor
• Colors: Red or Gray Order Codes/Model Numbers 3
• Mounting: Wall CSX CVX
3582 CSX10-24-R 0132 CVX10-115-S
0167 CSXG10-115-S
Order Codes/Model Numbers 3 3402 CSXG10-24-R
MB-G6 MB-G10
4884 MB-G6-6-R 3943 MB-G10-24-R
3941 MB-G6-24-R 3944 MB-G10-12-R
3942 MB-G6-12-R
4222 MB-G6-24-S TM

5. Series 43T Vibrating Bell


• Available in 6” & 10”
• Strobe synchronization with RSSP strobe plate
• Indoor or outdoor
• Colors: Red or Gray
• Mounting: Wall
Voltage test points for quick 8 candela settings Common base for wall and
troubleshooting and easy spot ceiling with 5 mounting
checking (wall models only) options

Order Codes/Model Numbers 3


Horn Strobes Strobes Horn
43T-G6 43T-G10
HSR STR HNR
1631 43T-G6-115-R 1651 43T-G10-115-R
HSW STW HNW
1630 43T-G6-115-S 3693 43T-G10-115-R HSRC STRC HNRC
1627 43T-G6-24-R 1647 43T-G10-24-R HSWC STWC HNWC
1626 43T-G6-24-S 3800 43T-G10-24-S
UL Max Current at 24 VDC

24 VDC 12 VDC
Regulated Voltage
Model(s) 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75
Range VDC

ST 8.0-33.0 0.082 0.095 0.102 0.148 0.176 0.197 0.242 0.282 0.125 0.159
RSS, RSSP, ZRS, CH
16.0-33.0 0.060 0.090 0.092 0.165 0.220 0.300 0.420
(Wall)
RSS, RSSP, ZRS, CH
16.0-33.0 0.065 0.105 0.189 0.249 0.300 0.420
(Ceiling)

UL Max. Current Audible


16-33 VDC VDC 0.022

Series RSS & RSSP 


Series ZRS

 


5.86 2.70

.56



2.58 10.76
&)2% !,!2- $%6)#% $/ ./4 0!).4

4.75

4.75
+

Series CH
5.24 5.24
2.68 2.68

5.13
WH E E L O C K

7.27
#
#

DIA
&

5.13

12
Specifications
Strobes, Chimes, Chime Strobes and Bells

MB Motor Bells 2.37

UL Max. 16-33 VDC 8-17.5


Wheelock Amber Lens
dBA @ 10 ft.
Current VDC VDC Strobes, Speaker Strobes and
10.0
0.040 0.090 92 DIA Weatherproof Appliances

43T Vibrating Bells

Input Current 16-33 VDC 115 VAC dBA @ 10 ft.


0.666 0.117 85
2.37

6.0
DIA

Series CVX/CSX 10.25

Input Current 115 VAC dBA @ 10 ft.


0.220 90

Input Current 16-33 VDC 115 VAC dBA @ 10 ft.


0.500 0.125 87

6.63 - Approvals include: UL 1638, UL


1971, UL 1480
ACCEPTED FOR USE
- UFC compliant
- Amber Lenses have been tested to
MODEL NO.
VOLTS
AMPS

meet UL 1971 light distribution


11.30 - Alert lettering with red text on white
base
- Field selectable candela settings of
15/30/75/110cd or 12/22/56/82cd
- 24VDC strobe models operate
from 16-33 VDC using filtered DC
or unfiltered FWR input voltage
- Weatherproof models
- Clear lenses also available
For more information on the colored
lens products see page 52
1 2 3 4
1. Series RSSWP Strobes 3. Series MTWP Multi-tone Strobes & MT Horn
• Provides wide range of intensities • 4 wire designs
• 8 selectable alerting sounds
Order Codes/Model Numbers 2
• 2 selectable sound outputs
Wall Ceiling
Order Codes/Model Numbers 2
9013 RSSWP-2475W-FR 4338 RSSWP-2475C-FR
Wall Ceiling
3034 RSSWP-2475W-FW 4446 RSSWP-2475C-FW
8420 MTWP-2475W-FR 4457 MTWP-2475C-FR
5161 RSSWP-24MCWH-FR 5167 RSSWP-24MCCH-FR
3112 MTWP-2475W-FW 4478 MTWP-2475C-FW
5165 RSSWP-24MCWH-FW 5187 RSSWP-24MCCH-FW
5132 MTWP-24MCWH-FR 5102 MTWP-24MCCH-FR
2. Series ASWP Audible Strobes & AH 5134 MTWP-24MCWH-FW 5122 MTWP-24MCCH-FW
Audible Horns Wall or Ceiling
• 2 wire applications 5023 MT-12/24-R
• 3 selectable dBA settings (90, 95, 99)
Order Codes/Model Numbers 2
4. Series ET70WP Speaker Strobes & ET Speaker
Wall Ceiling
• High efficiency sound output
9012 ASWP-2475W-FR 4251 ASWP-2475C-FR
• Field selectable input voltage (25/70VRMS)
5755 ASWP-2475W-FW 4502 ASWP-2475C-FW • Field selectable taps from 1/8 to 8 watts
5137 ASWP-24MCWH-FR 5149 ASWP-24MCCH-FR
Order Codes/Model Numbers 2
5140 ASWP-24MCWH-FW 5157 ASWP-24MCCH-FW
Wall Ceiling
Wall or Ceiling
9077 ET70WP-2475W-FR 4452 ET70WP-2475C-FR
7416 AH-24WP-R 7415 AH-12WP-R
3179 ET70WP-2475W-FW 4454 ET70WP-2475C-FW
4885 ET70WP-24MCWH-FR 4845 ET70WP-24MCCH-FR
General Features and Options:
4891 ET70WP-24MCWH-FW 4859 ET70WP-24MCCH-FW
Available Colors: Red or white
Wall or Ceiling
Mounting: Wall or ceiling
3135 ET-1010-W 3137 ET-1010-R
Double Entry Backbox for Simplified Installation
Weatherproof -40º to 150ºF
Approvals Include Note 1: UL Standards 1971, 1638,
464 and 1480, ULC, CSFM, MEA, FM and BFP

Note 1: See approvals chart on page 32 for approvals by model. For mounting options, refer to pages 34-39.
14 Note 2: Additional models are available. Contact customer service for more information.
Weatherproof Appliances and
Mounting Accessories

5 6
5. WFP and WFPA Plates 6. Backboxes for Weatherproof Appliances
• Allow for flush mounting of weatherproof products • Flush and Surface Mount
without an external back box • Mounting screw supplied
• Available in red or white
Order Codes/Model Numbers 2
Order Codes/Model Numbers 2
Backboxes
Flush Plates Gasket Kit 5046 IOB-R 9014 WPBB-R
5698 WFPA-R 4486 WP-KIT 1
5047 IOB-W 4692 WPBB-R
4701 WFPA-W 9751 WPSBB-R 2959 WBB-R
4696 WFP-R 3033 WPSBB-W 2960 WBB-W
4697 WFP-W
1
WP-KIT - Allows for surface mounting of a
weatherproof back box to a recessed electrical box.

Mounting Options: Backboxes, Plates, Gasket Kits


Surface Mount Flush
Exposed Conduit Concealed Conduit Mount
RSSWP Strobes WPSBB WPSBB + WP-KIT WFP
ET70WP Speaker Strobes IOB IOB + WP-KIT WFP
ASWP Horn Strobes WPBB WPBB + WP-KIT WFPA
AHWP Horns WBB - WFP
ET-1010 Speakers WBB - WFP
MTWP Multitone Strobes IOB IOB + WP-KIT WFP
Multitone IOB IOB + WP-KIT WFP
Specifications
Weatherproof Appliances

RSSWP & ASWP & ET70WP


Candela Ratings UL Max. Current MTWP/MT MT
(Audible) 16-33 VDC 8-17.5 VDC
UL 1638 UL 1638 RSS, ET70WP and ASWP
Series UL 1971 dBA HI STD HI STD
@ 77°F @ -40°F MTWP UL Max Current High Med Low
Horn 0.108 0.044 0.177 0.034
2475 30 180 115 0.138 0.168 0.155 0.150
135 135 65 0.300 0.355 0.340 0.335 Bell 0.053 0.024 0.095 0.020
MCWH March Time 0.104 0.038 0.142 0.034
185 185 90 0.420 0.480 0.465 0.460
115 115 50 0.300 0.355 0.340 0.335 Code 3 Horn 0.091 0.035 0.142 0.034
MCCH
177 177 75 0.420 0.480 0.465 0.460 Code 3 Tone 0.075 0.035 0.105 0.021
Slow Whoop 0.098 0.037 0.142 0.035
UL Max. Current AH UL Reverberant dBA @ 10 Feet Siren 0.104 0.036 0.152 0.030
16-33 VDC 8-17.5 VDC Hi/Lo 0.057 0.025 0.114 0.026
Model(s) 1/8 1/4 1/2 1 2 4 8
High (99) dBA 0.080 0.192
ET70WP 75 78 81 84 87 90 93
Med (95) dBA 0.043 0.108
Low (90) dBA 0.021 0.058

Series RSSWP Series AHWP Series ASWP




   



 CD
70



Series ET-1010 Series ET70WP Series MTWP

4.09
1.92 5.638


5.120 CD
70


4.29 75cd
WP

&)2% !,!2- $%6)#% $/ ./4 0!).4

5.120



FIRE ALARM DEVICE - DO NOT PAINT

4.29

16
MIN-T Tamper Switch Horns
The Wheelock MIN-T products provide you the opportunity to effectively alert individuals
with confidence. These horns and horn strobes are built with reliable and flexible
features to accommodate a multitude of applications.

2 Prioritized Inputs (32 Tones Available) Tamper Contacts


Low Current Draw Indoor/Outdoor (NEMA 4, IP66)
12 V Audible: 2-19mA
12 V Audible Strobe: 354-393mA Wide Voltage Range (9 to 60 VDC)
24V Audible: 6-33mA Wide Temperature Range (-13°F to 158°F)
24V Audible Strobe: 100-112mA

www.coopernotification.com For additional information on the MIN-T, see page 28.

All Cooper logos are valuable trademarks of Cooper Industries in the U.S. and other countries. You are not permitted to use Cooper trademarks without the prior written consent of Cooper Industries.
1 2 3
1. Series E50 & E60 2. Series E70 & E90
• High efficiency sound output • High efficiency sound output
• Field selectable input voltage (25/70 VRMS) • Field selectable input voltage (25/70 VRMS)
• Field selectable taps from 1/8 to 2 watts • Field selectable taps from 1/8 to 2 watts
• Snap-on Grills
Order Codes/Model Numbers Note 2
• No extension ring required
Wall Ceiling
Order Codes/Model Numbers Note 2
9022 E70-24MCW-FR 3166 E90-24MCC-FW
Wall Ceiling
9023 E70-24MCW-FW 3165 E90-24MCC-FR
0226 E50-24MCW-FR 3747 E60-24MCC-FW
7871 E70-241575W-FR 7869 E90-W
0227 E50-24MCW-FW 3748 E60-24MCC-FR
7866 E70-R 0213 E90A-24MCC-NW
0225 E50-241575W-FW 3745 E60-W
6397 E50-24MCW-ALW 3749 E60-24MCCH-FW

3. Series ET70 & ET90


• High efficiency sound output
• Field selectable input voltage (25/70 VRMS)
• Field selectable taps from 1/8 to 8 watts
Order Codes/Model Numbers Note 2
General Features and Options:
Wall Ceiling
Available Colors: Red, white or nickel
9020 ET70-24MCW-FR 3164 ET90-24MCC-FW
Mounting: Wall or ceiling 9021 ET70-24MCW-FW 3473 ET90-24MCCH-FW
Standard Backboxes 7844 ET70-W 7846 ET90-W
Strobe/Horn Synchronization 7840 ET70-R
Multi-Candela or High Intensity Models
Replaceable Grills
Approvals Include Note 1: UL, ULC, FM, CSFM, MEA, BFP
Wall Intensities: 15, 30, 75, 110cd or 135/185cd
Ceiling Intensities: 15, 30, 75, 95cd or 115/177cd

Note 1: See approvals chart on page 32 for approvals by model. For mounting options, refer to pages 34-39.
18 Note 2: Additional models are available. Contact customer service for more information.
Speakers & Speaker Strobes

4 5 6
4. Series ET-1010 & ET80 6. Series SA-S
• Provide full range of rugged, high performance • Supervised Self Amplified Speakers &
combinations Speaker Strobes
• Vandal resistant • Ideal for Sensitive Compartmented
• Sealed back box Information Facilities (SCIF) room
applications
Order Codes/Model Numbers Note 2
Wall Wall or Ceiling Order Codes/Model Numbers Note 2
3476 ET80-24MCW-FR 3135 ET-1010-R Wall Ceiling
3477 ET80-24MCW-FW 3137 ET-1010-W 1006 SA-S70-24MCW-FR 1005 SA-S90-24MCC-FW
1003 SA-S70-W 1001 SA-S90-W

5. Series S
• 8” Ceiling speakers & speaker strobes
• UL Listed under Standard 1480
• Metal Grill
• 8” and 4” tile bridge available Wheelock Amber Lens
• 8” speaker backbox available Strobes, Speaker Strobes
Order Codes/Model Numbers Note 2 and Weatherproof
Ceiling
Appliances
0054 S8-24MCC-FW
0052 S8-70/25
3314 CBB-8
3573 SBB-8

For more information on the


colored lens products see
page 52
Specifications
Speakers & Speaker Strobes

UL Max Current at 24 VDC


24 VDC
Regulated Voltage
Model(s) 15 15/75 30 60 75 95 110 115 135 150 177 185
Range VDC

E50, E70, ET70, ET80, SA 16.0-33.0 0.060 0.090 0.092 0.165 0.220 0.300 0.420

E60, E90, ET90, S8 16.0-33.0 0.065 0.105 0.189 0.249 0.300 0.420

UL Reverberant dBA @ 10 Feet SA-S UL Reverberant dBA @ 10 Feet


Sound SA-S90
Model(s) 1/8 1/4 1/2 1 2 4 8 SA-S90-24MCC SA-S90-24MCCH
Level SA-S70
E50, E60, E70, E90 Speaker 77 81 83 86 89 6 84 84 82
E50, E60, E70, E90 Speaker Strobe 76 80 82 85 88 5 82 81 81
4 77 77 76
ET70, ET90, S8 Speaker 75 78 81 84 87 90 93 3 75 74 74
ET70, ET90, S8 Speaker Strobe 75 78 81 84 87 90 93 2 71 71 70
1 69 68 68
ET-1010 77 80 83 86 87 92 94

ET80 78 81 84 87 90 92 94
ET-1080 78 81 84 87 90 93 96 Series ET80 & ET-1010
  

Series E50 & E60 Series E70 & E90, ET70 & 1.92
4.09

  ET90 & SA 5.24


2.68 

 ,/.' "2!.#( .* ).#

4.29 4.09
1.92


WH E E L O C K

7.27
#


#

   DIA


&

4.29

5.24 4.29
2.68
,

Series S8


 4.29


5.13



5.13



20
Wheelock

3”

Extra Module Space


Reduce Installation Time & Cost

Distinguishable LED’s
Reduce Diagnostic Time & Cost

Available Expansion Board


Increase NAC Outputs

It’s more than just providing POWER, it’s


about lowering total cost of ownership.
Today you demand products that offer savings.
That’s why we developed a power supply that lowers installation and total cost of
ownership. The distinguishable ground fault LED’s on Wheelock Power Supplies pinpoint
the problem circuits without having to remove all of the field wiring from the panel. This
reduces diagnostic time and increases your labor savings.

For more information on the PS-6 and PS-8, see page 25.
1 2 3 4
1. Series STH-15S 3. Series STH Weatherproof Cluster
• 15 watt high efficiency compression driver • Deliver up to 125 dB @ 30 watts, 1 meter
• Superior intelligibility and dispersion • Strobe has 100cd at 60 double flashes per
• Weather & vandal resistant minute
• 25/70/100V transformer • Prefabricated to a 13.5” x 10.5” x 6.25”
• 5 mfd capacitor for line supervision • UL Standard 1638
• Adapter plate for mounting to 4” square box Order Codes/Model Numbers
(SHMP)
Cluster with MAX Strobe
• Approvals: UL Standard 1480, CSFM
9762 STH-4M30WC
Order Codes/Model Numbers
Horn Adapter Plate 4. STH Cluster Speakers with RSS Strobe(s)
7937 STH-15-S 8154 SHMP-R
• High intensity visual alerting, selectable 115/177cd
7938 STH-15-SR • Available with one or three strobes
• Deliver up to 102 dB @ 15 watts @ 10 ft per horn
• Prefabricated to a 10” x 10” x 6”
• UL Standard 1480 (horns), UL 1971 (RSS Strobes), UL
2. STH Cluster Speakers with MAX Strobe
Standard 1638 (Colored lens strobes)
• Deliver up to 102 dB @ 15 watts @ 10 ft per
horn Order Codes/Model Numbers
• Strobe has 100cd at 60 double flashes per
Cluster with RSS Strobe Cluster with 3 RSS Strobes
minute
• Prefabricated to a 10” x 10” x 6” 3089 STH-4R24MCCH-NR 3810 STH-4R24MCCH110R-NR
0239 STH-4R24MCCH-NW 3827 STH-4R24MCCH110B-NR
Order Codes/Model Numbers 3144 STH-3R24MCCH-NR 3826 STH-4R24MCCH110G-NR
Cluster with MAX Strobe Cluster 0238 STH-3R24MCCH-NW 3829 STH-4R24MCCH110A-NR
8157 STH-4MS-R 8186 STH-4R 3146 STH-2R24MCCH-NR
8156 STH-3MS-R 9753 STH-3R 3227 STH-90-4R24MCCH-NR
8155 STH-2MS-R 9752 STH-2R
0101 STH-2G

22
Supervised Horns & Cluster Speakers

4.28  315!2%  315!2%


 315!2%  315!2%

8.13
4.28

UL Max. Current 115cd 177cd


24 VDC 0.300 0.420
7.90
).#

,/.' "2!.#( .*

70.7 Volts 25 Volts 100 Volts


Impedance
Setting dB@ dB@ dB@
(Ohms) Watts Watts Watts

10 ft 10 ft 10 ft
1 5,000 0.9W 93 n/a n/a 2.0W 93
,/.' "2!.#( .*

).#

 2 2,500 1.8W 96 n/a n/a 4.0W 96


3 1,300 3.8W 96 0.48W 90 7.5W 99
).#

,/.' "2!.#( .*

 4 666 7.5W 99 0.94W 90 15.0W 102


5 333 15.0W 102 1.8W 93 n/a n/a
6 89 n/a n/a 7.5W 99 n/a n/a
).#
,/.' "2!.#( .*
7 45 n/a n/a 15.0W 102 n/a n/a

21.0 General Features and Options:

7.17 DIA
Designed for high ambient noise environments
Omnidirectional horn
High intelligibility voice production
High intensity visual alerting
21.0 4.92
Wall or ceiling mount
1 Sync Capability (With SM, DSM, PS-6 & PS-8)
Model Audible Strobe Model Audible Strobe
1. Series SM & DSM AH-12 Yes - HS-24 Yes -
• Provide the ability to synchronize AH-24 Yes - HS4-241575W Yes Yes
strobe flashes and the code 3 temporal AH-12WP Yes - HS4-24MCW Yes Yes
AH-24WP Yes - HS4-24MCWH Yes Yes
evacuation alarms from Wheelock
AMT-241575W No Yes MIZ-24S Yes -
appliances
AMT-241575W-FR-NYC No Yes MT-121575W No Yes
• Provide ability to silence the audible AMT-24MCW No Yes MT-241575W No Yes
alarm while maintaining the strobe AS-241575W Yes Yes MT-24MCW No Yes
flashes over a single pair of wires AS-24MCC Yes Yes MTWP-2475W No Yes
• Low operating current AS-24MCCH Yes Yes NH-12/24 Yes -
• 3 ampere per circuit at 12 or 24 VDC AS-24MCW Yes Yes NH-12/24R Yes -
• Approvals: UL, ULC, FM, CSFM, MEA, AS-24MCWH Yes Yes NS-121575W Yes Yes
ASWP-2475W Yes Yes NS-241575W Yes Yes
BFP
CH70-241575W No Yes NS-24MCW Yes Yes
Order Codes/Model Numbers CH7024MCW No Yes NS-24MCC Yes Yes
CH7024MCWH No Yes NS-24MCCH Yes Yes
6369 SM-12/24-R CH90-24MCC No Yes RSS-241575W - Yes
6374 DSM-12/24-R CH90-24MCCH No Yes RSS-121575W - Yes
E50-24MCW - Yes RSS-24MCC - Yes
E50-25MCWH - Yes RSS-24MCCH - Yes
E50-241575W - Yes RSS-24MCCHR - Yes
E60-24MCC - Yes RSS-24MCCR - Yes
E60-24MCCH - Yes RSS-24MCW - Yes
E70-241575W - Yes RSS-24MCWH - Yes
UL Max. Current 1575cd
E70-24MCW - Yes RSSP-121575W - Yes
16-33 VDC 8-17.5 VDC E70-24MCWH - Yes RSSP-241575W - Yes
SM-12/24 0.038 0.023 E90-24MCC - Yes RSSP-24MCW - Yes
DSM-12/24 0.045 0.026 E90-24MCCH - Yes RSSP-24MCWH - Yes
ET70-241575W - Yes RSSWP-2475W - Yes
ET70-24MCW - Yes S8-24MCC - Yes
1.34
ET70-24MCWH - Yes S8-24MCCH - Yes
4.97
ET70WP-2475W - Yes SA-S70-24MCW - Yes
THIS DEVICE COMPLIES WITH PART 15 OF THE
FCC RULES. 0PERATION IS SUBJECT TO THE
FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY
ET80-241575W - Yes SA-S90-24MCC - Yes
NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS

ET80-24MCW - Yes
DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED,
INCLUDING INTERFERENCE THAT MAY CAUSE

SA-S90-24MCW - Yes
UNDESIRED OPERATION.

ET80-24MCWH - Yes ST - Yes


ET90-24MCW - Yes ZNS-MCC - Yes
4.97
ET90-24MCWH - Yes ZNS-MCW - Yes
ET90-24MCC - Yes ZRS-MCC - Yes
ET90-24MCCH - Yes
ZRS-MCW - Yes
HN Yes -
HS Yes Yes

24
Sync Modules and Power Supplies

2
2. Series PS-6 and PS-8 Power Supplies
• 24 VDC, filtered and regulated, supervised
remote power supply/battery charger
• Used for supervision and expanded power
driving capability for Fire Alarm Notification
Appliance Circuits
• PS-6 provides 6 amps of power distributed
across 4 outputs
• PS-8 provides 8 Amps across 4 outputs
• Distinguishable ground fault LED’s
• True Input to Output Mapping

Model Numbers
PS-6 6 Amp Power Supply
PS-8 8 Amp Power Supply
PS-6-EXP 6 Amp Power Supply with preinstalled expansion module
PS-8-EXP 8 Amp Power Supply with preinstalled expansion module
PS-EXP Expansion Module for use with PS-6 & PS-8 Amp Power Supplies;
4 Class B or 2 Class A Expansion Modules
PS-EXP-RETRO Retrofit Upgrade Kit #
#Contact Technical Support for additional information on upgrade options

Output NAC Circuit Output Voltage/Current


Four (4) Class “B” or 24 VDC @ 3 amps per circuit
Two (2) Class “A” or 24 VDC @ 3 amps per circuit
One (1) Class “A” and Two(2) Class “B” or 24 VDC @ 3 amps per circuit (Class “A”
Four (4) Class “A” (optional PS-4CA module) 24 VDC @ 3 amps per circuit (Class “A”
Standby Current 0.080 Amps
Alarm Current 0.240 Amps
Total NAC Current 8 Amps Max.

Standby Alarm Output Aux Output


Standby Batteries
Time Total Amps/Minutes CP Mode MP Mode
24 VDC/12AH 24 Hours 8 Amps/15 Minutes 200 mA 3.5A during
(uses two 12 VDC batteries in series) 60 Hours 8 Amps/15 Minutes 60 mA nonalarm
MPS Pull Stations and Enclosures

1 2
1. Series MPS Pull Stations 2. Enclosures
• High quality, die-cast metal for lasting • Designed for use with Wheelock UL
performance, Red enamel finish approved appliances
• Single gang back box • Vandal resistant; NEMA-4 Rated
• Wall mount • Easy Installation and access
• Single or dual action • Provides protection from incidental contact
• Key Reset with equipment, fall dirt, falling liquid,
• Terminal strip connections splashes, rain
• Explosion proof model available • UV stabilized against discoloration
• Approvals: UL, FM, CSFM, MEA
Order Codes/Model Numbers
Order Codes/Model Numbers 8151 EWR
SPST Backboxes 8150 EWP
8400 MPS-100 8404 MPS-ISB 8152 EN4
8401 MPS-200 8405 MPS-WP
Explosion Proof Breakrods
8403 MPS-400X 8406

BACKBOX, REF
COVER REMOVED FOR CLARITY
7.5

9.5

ENCLOSURE DIM: 9.5"H x 7.5"W x 7.5"D APPROX.

26
Replacement Grills and Covers

3
Description Order Code Used On Color Lettering
ECHG50-R 0135 E50 Red -
ECHG50-W 0136 E50 White -
ECHGS50-FR 0137 E50 w/Strobe Red FIRE
ECHGS50-FW 0138 E50 w/Strobe White FIRE
ECHSG60-FW 4491 E60 w/Strobe White FIRE
ECHSG60-FR 4490 E60 w/Strobe Red FIRE
ECHG60-W 4489 E60 White -
ECHG60-R 4488 E60 Red -
ECHG70-N 3221 E70, ET70, CH70 Nickel Plate -
ECHG70-R 9058 E70, ET70, CH70 Red -
ECHG70-W 9059 E70, ET70, CH70 White -
ECHSG70-FN 3224 E70, ET70, CH70 w/Strobe Nickel Plate FIRE
ECHSG70W-FR 9060 E70, ET70, CH70 w/Strobe Red FIRE
ECHSG70W-FW 9061 E70, ET70, CH70 w/Strobe White FIRE
ECHG90-N 3222 E90, ET90, CH90 Nickel Plate -
ECHG90-R 9062 E90, ET90, CH90 Red -
ECHG90-W 9063 E90, ET90, CH90 White -
ECHSG90-N 3223 E90, ET90, CH90 w/Strobe Nickel Plate -
ECHSG90-R 9064 E90, ET90, CH90 w/Strobe Red -
ECHSG90-W 9065 E90, ET90, CH90 w/Strobe White -
NSP-R 9054 NS Red -
NSPW-FR 9055 NS Red FIRE
NSP-W 9056 NS White -
NSPW-FW 9057 NS White FIRE
RSSCP-R 9050 RSS Red -
RSSCPW-FR 9051 RSS Red FIRE
RSSCP-W 9052 RSS White -
RSSCPW-R 9053 RSS White FIRE
RSSRP-R 4492 RSSR Red -
RSSRP-FR 4493 RSSR Red FIRE
RSSRP-W 4494 RSSR White -
RSSRP-FW 4495 RSSR White FIRE
1 2 3
1. Series MIN-T 2. Series FLS Audible Strobe
• Rugged alarm designed for indoor/outdoor • High sound output with volume control
environments Tamper contacts • Designed for security and process alarm applications
• Low current draw • 24 VDC
• Audible 7 to 56 mA • Automatic synchronization
• Audible/Strobe 100 to 393 mA • Choice of lens and alarm color combinations
• Up to 113 dB output • Indoor
• Horn & Horn Strobe Models • Base compatible with the Series ROS and CLR
• 32 tones, dip switch selectable
• 2 prioritized inputs for tones Order Codes/Model Numbers
• 9 to 60 VDC 4069 FLS-A-DC
• -13 to 158 F (-25°c ~ +70°C)
4070 FLS-B-DC
• NEMA 4 (IP 66)

Order Codes/Model Numbers


9087 MIN-T
9068 MIN-TA 3. Series SLS Strobe
9086 MIN-TB
• Ideal for a wide range of applications
9069 MIN-TR • Wide operating voltage up to 60 VDC
• Current surge suppression
• Automatic synchronization
• High efficiency
• Constant base performance over voltage range
For devices that include colored lenses: • Strobe can be locked onto base
A = Amber • Weatherproof when used with the deep base
(Series DB)
B = Blue
R = Red Order Codes/Model Numbers
4089 SLS-B-DC
4088 SLS-R-DC

Additional models are available. Contact customer service for more information.
28
Security Signaling Devices

4 5 6
4. Series SQA Multi-tone Alarm 6. Series DB Deep Base
• Efficient base alarm that offers ultra-low power • Locking capability
operation • Weatherproof
• Low current consumption
• Blank cover for use as a stand alone alarm • FR ABS material
• Reduced installation costs • Used with Series ROS, FLS, SLS

Order Codes/Model Numbers Order Codes/Model Numbers


4067 SQA-DC 4090 Deep Base
4091 Deep Base + Mains Module

Color: Off White


Cable Entries: (2) 1⁄2” knock-
outs
5. Series ROS Multi-tone Alarm
• Ideal for security, general signaling and process
alarm applications
• High sound output
• 32 tones user selectable
• Low current consumption
• Automatic synchronization
• Volume Control
• Indoor/Outdoor (with deep base)
• Two stage alarm, (1 programmable, 1 fixed)

Order Codes/Model Numbers


4064 ROS-DC
Specifications
Security Signaling Devices

MIN-T Series SQA Multi-tone Alarm


2 Prioritized Inputs (32 Tones Available) Nominal Voltage: 9-30 VDC
Low Current Draw Current Consumption
12 V Audible: 2-19mA (tone dependant): Between 5.5 - 15mA
12 V Audible Strobe: 354-393mA Sound Output
24V Audible: 6-33mA (tone dependant): Between 83dB - 97dB
24V Audible Strobe: 100-112mA Alarm Tones: 4
IP Rating: IPZ1C
Series SLS Strobe Color: Off White
Voltage: 10-60 VDC Approvals: UCST/ULSZ (file S7361)
Current: Maximum 220mA at 24VDC Operating Temperature: 14º to 131º F (-10º to 55º C)
(includes current surge suppression)
Volume Control: High/Low settings
Light Source: Xenon
Monitoring Mode: Polarized Diode
Light Output: 15 CD (based on red lens)
IP Rating: IP65 when used with deep
base
Color: Off White
Flash Rate: 1 Hz (60/min)
Synchronization: 1ms over 30 min
Anti-tamper
(where fitted): Normally closed contacts.
Contacts open when strobe
removed from base
Operating Temperature: 13º to 158º F (-25º to 70º C)
Volume Control: 0 to -20dB
Series ROS Multi-tone Alarm
Nominal Voltage: 9-28 VDC
Series FLS
Nominal Voltage: 18-30VDC Current Consumption
(tone dependant): Maximum 33mA @ 24 VDC
Current Consumption
(tone dependant): 68mA (average) Sound Output
(tone dependant): Between 88dB - 111dB
Sound Output
(tone dependant): 101dB Alarm Tones: 32
Alarm Tones: 2 IP Rating: IP65 with deep base, IP54 with shallow base
IP Rating: IP65 w/ deep base, IP 54 with shallow base Color: Off White
Color: Off White
Mounting: Wall
Flash Rate: 1 Hz (60 per min)
Operating Temperature: 13º to 158º F (-25º to 70º C)
Strobe Type: U-Tube
Volume Control: 0 to -20dB
Operating Temperature: 14º to 131º F (-10º to 55º C)
Volume Control: 0 to -20dB
Monitoring Mode: Polarized Diode

30
UL Listed Explosion Proof & Hazardous Location
Horns, Speakers and Strobes Suitable for Fire
Alarm Applications

See pages 40-46 for additional information.

www.coopernotification.com
Agency Approvals
Agency Approvals* Agency Approvals* Agency Approvals*
Model Model Model
UL MEA CSFM FM BFP UL MEA CSFM FM BFP UL MEA CSFM FM BFP
31T-115R X X X X X E70-24MCWH-FN X X X X * MB-G10-12-R X X X X X
31T-115-R-ULC/CSA X X X X X E70-24MCWH-FR X X X X * MB-G10-24-R X X X X X
43T-G6-24-R X X X X X E70-24MCWH-FW X X X X * MIZ-24S-R X X X X *
43T-G6-115-R X X X X X E70-N X X X X X MIZ-24S-W X X X X *
43T-G10-24-R X X X X X E70-R X X X X X MT-12/24 X X X X X
43T-G10-115-R X X X X X E90-24MCC-FN X X X X * MT-121575W-FR X X X X *
AH-12-R X X X X X E90-24MCC-FW X X X X * MT-241575W-FR X X X X *
AH-12WP-R X X X X E90-24MCCH-FN X X X X * MT-24MCW-FR X * X * *
AH-24-R X X X X X E90-24MCCH-FW X X X X * MT-24MCW-FW X * X * *
AH-24WP-R X X X X E90-N X X X X X MT4-115-R X X X X X
AMT-12/24-R X X X X X E90-W X X X X X MT4-115-WH-VFR X X X X X
AMT-12/24-R-NYC X X X X X ET-1010-R X X X X X MTWP-2475W-FR X X X X *
AMT-241575W-FR X X X X * ET-1010-W X X X X X MT4-115-R X X X X X
AMT-241575W-FW X X X X * ET-1080-R X X X X X MT4-115-WH-VFR X X X X X
AMT-241575W-FR-NYC X X X X * ET70-241575W-FN X X X X X MTWP-2475W-FR X X X X *
AMT-24MCW-FR X * X * * ET70-241575W-FR X X X X X NH-12/24-R X X X X X
* NH-12/24R-R X * * * *
AMT-24MCW-FW X X * * ET70-24MCW-FN X X X X X
AS-241575W-FR X X X X X ET70-24MCW-FR X X X X X NH-12/24R-W X * * * *
AS-121575W-FR X X X X ET70-24MCW-FW X X X X X NS-121575W-FR X X X X X
AS-24MCC-FR X X X * * ET70WP-2475W-FR X X X * * NS-241575W-FR X X X X X
AS-24MCC-FW X X X * * ET70-24MCWH-FN X X X X * NS-24MCC-FR X * * * *
AS-24MCCH-FW X X X * * ET70-24MCWH-FR X X X X * NS-24MCC-FW X * * * *
AS-24MCW-FR X X X X X ET70-24MCWH-FW X X X X * NS-24MCCH-FR X * * * *
AS-24MCW-FW X X X X X ET70-N X X X X X NS-24MCCH-FW X * * * *
AS-24MCWH-FR X X X * * ET70-R X X X X X NS-24MCW-FR X X X X X
AS-24MCWH-FW X X X * * ET80-241575W-FR X X X X * NS-24MCW-FW X X X X X
ASWP-2475W-FR X X X X X ET80-241575W-FW X X X X * PS-6 X * X X *
CH70-241575-FR X X X X X ET80-24MCW-FR X X X X * PS-8 X * X X *
CH70-24MCW-FR X X X X X ET80-24MCW-FW X X X X * RSS-121575W-FR X X X X X
CH70-24MCW-FW X X X X X ET80-24MCWH-FR X X X X * RSS-241575W-FR X X X X X
CH70-24MCWH-FR X X X X * ET80-24MCWH-FW X X X X * RSS-24MCC-FW X X X X *
CH70-24MCWH-FW X X X X * ET90-24MCC-FN X X X X * RSS-24MCCH-FW X X X * *
CH70-24-R X X X X X ET90-24MCC-FW X X X X * RSS-24MCCHR-FW X X X * *
CH90-24MCC-FW X X X X * ET90-24MCCH-FN X X X X * RSS-24MCCR-FW X X X * *
CH90-24MCCH-FW X X X X * ET90-24MCCH-FW X X X X * RSS-24MCW-FR X X X X X
CH90-24-W X X X X X ET90-N X X X X X RSS-24MCWH-FR X X X * *
CSX10-115-R X X X X X ET90-W X X X X X RSSP-121575W-FR X X X X X
CSX10-24-R X X X X X HNR X * X * * RSSP-241585W-FR X X X X X
CVX10-115-R X X X X X HNW X * X * * RSSP-24MCW-FR X X X X X
E50-R X * X X * HNRC X * X * * RSSP-24MCWH-FR X X X * *
E50-W X * X X * HNWC X * X * * RSSWP-2475W-FR X X X X *
E50-241575W-FR X * X X * HS-24-R X X X X * SM-12/24-R X X X X X
E50-241575W-FW X * X X * HS-24-W X X X X * STR X * X * *
E50-24MCW-FR X * X X * HS4-241575W-FR X X X X * STW X * X * *
E50-24MCW-FW X * X X * HS4-241575W-FW X X X X * STRC X * X * *
E50-24MCWH-FR X * X X * HS4-24MCW-FR X X X X * STWC X * X * *
E50-24MCWH-FW X * X X * HS4-24MCW-FW X X X X * ZNH X * X * *
E60-R X * X X * HS4-24MCWH-FR X X X * * ZNS-MCC X * X * *
E60-W X * X X * HS4-24MCWH-FW X X X * * ZNS-MCCH X * X * *
E60-24MCC-FR X * X X * HSR X * X * * ZNS-MCW X * X * *
E60-24MCC-FW X * X X * HSW X * X * * ZNS-MCWH X * X * *
E60-24MCCH-FR X * X X * HSRC X * X * * ZRS-MCC X * X * *
E60-24MCCH-FW X * X X * HSWC X * X * * ZRS-MCCH X * X * *
E70-241575W-FR X X X X X MB-G6-12-R X X X X X ZRS-MCW X * X * *
E70-241575W-FN X X X X X MB-G6-24-R X X X X X ZRS-MCWH X * X * *
E70-24MCW-FN X X X X X
E70-24MCW-FR X X X X X
E70-24MCW-FW X X X X X
*Please Note: BFP and MEA approvals
are no longer required on fire appliances

32
Wheelock ExcederTM Cross Reference
The enhanced features of the new Wheelock Exceder appliances offer you
Horn Strobes, the benefits of multiple legacy models all in one.
Strobes, & Horns
The AH/AS, NH/NS, and Z Series of products will be discontinued as of
March 31, 2010.

Over 80% Reduction in SKUs* – 64 to 12


TM

Horn Strobes
New Models HSR HSW HSRC HSWC
Description Red, Wall White, Wall Red, Ceiling White, Ceiling
AS-24MCW-FR AS-24MCW-FW AS-24MCC-FR AS-24MCC-FW
AS-24MCWH-FR AS-24MCWH-FW AS-24MCCH-FR AS-24MCCH-FW
AS-241575W-FR AS-241575W-FW NS-24MCC-FR NS-24MCC-FW
AS-121575W-FR AS-121575W-FW NS-24MCCH-FR NS-24MCCH-FW
Legacy NS-24MCW-FR NS-24MCW-FW ZNS-MCC-FR ZNS-MCC-FW
ZNS-MCW-FR ZNS-MCW-FW ZNS-MCCH-FR ZNS-MCCH-FW
ZNS-MCWH-FR ZNS-MCWH-FW
NS-241575W-FR NS-241575W-FW
NS-121575W-FR NS-121575W-FW

Strobes
New Models STR STW STRC STWC
Description Red, Wall White, Wall Red, Ceiling White, Ceiling
RSS-24MCW-FR** RSS-24MCW-FW** RSS-24MCC-FR** RSS-24MCC-FW**
RSS-241575W-FR** RSS-241575W-FW** RSS-24MCCR-FR** RSS-24MCCR-FW**
RSS-24MCWH-FR** RSS-24MCWH-FW** RSS-24MCCH-FR** RSS-24MCCH-FW**
Legacy
RSS-121575W-FR RSS-121575W-FW RSS-24MCCHR-FR RSS-24MCCHR-FW
ZRS-MCW-FR ZRS-MCW-FW ZRS-MCC-FR ZRS-MCC-FW
** Not Included in
ZRS-MCWH-FR ZRS-MCWH-FW ZRS-MCCH-FR ZRS-MCCH-FW Discontinuation Plan

Horns
New Models HNR HNW HNRC HNWC
Description Red, Wall White, Wall Red, Ceiling White, Ceiling
ZNH-R ZNH-W NH-12/24R-R NH-12/24R-W
NH-12/24-R NH-12/24-W
Legacy
AH-12-R AH-12-W
*Includes both red & white for all appliances. Does
AH-24-R AH-24-W not include special lettering or colored lens models

Cooper Notification, backed by $6.5 billion global manufacturer Cooper Industries, Ltd. with
facilities in 23 countries, provides premier safety and mass notification solutions worldwide
through our local delivery and service MNS Channel Partner program.

Notification
Series Wall or Ceiling Mounting Options
Exceder Wall B, D, E, F
Exceder Ceiling B, D, E, F
Z Wall B, D, E, F, FF
Z Ceiling B, D, E, F, FF
NH/NS Wall B, D, E, F, G, H, J, N, O, P, R, X
NS Ceiling D, E
AH/AS Wall B, D, E, F, G, H, J, N, O, P, R, X
AS Ceiling B, D, E, F, G, H, J, N, O, P, R, X
HS/HS4 Wall or Ceiling D, E, F, L, M, O, P, R
MT Wall D, E, F, J, L, M, N, O, P, R
MT4 Wall or Ceiling D, E, J, K, N, O, R
AMT Wall or Ceiling D, E, F, L, M, O, P, R
MIZ Wall B
31T Wall D, E, J, K, N, O, R
RSS Wall B, D, E, F, G, H, J, N, O, P, R, X
RSSP Wall D, E, Z
RSS Ceiling B, D, E, F, G, H, J, N, O, P, R, X
CH70 Wall L, O, P, Q, R, U, Y
CH90 Ceiling Q, U, V
MB Wall D, E, J, K, N, O, P, R, S
43T Wall D, E, J, K, N, O, P, R, S
E50 Wall E, Q, U, BB
E60 Ceiling Q, U, V
E50* Wall E, O, P, Q, R, U, Y, AA
E60* Ceiling Q, U
E70 Wall L, O, P, Q, R, U, Y
E90 Ceiling Q, U, V
ET70 Wall L, O, P, Q, R, U, Y
ET80 Wall O, P, Q, R, Y
ET-1010 Wall or Ceiling K, N, O
ET-1080 Wall or Ceiling O, P, Q, Y
SA-S70 Wall L, O, P, Q, R, U, Y
SA-S90 Ceiling Q, U, V
SM/DSM Wall W
ET90 Ceiling Q, U, V
*Speaker Only Models

34
Mounting
(b) single-gang, flush (d) 4” square, flush

1-1½” Deep
3 1/2” Deep for MIZ and
conduit installations

MAXIMUM NUMBER OF CONDUCTORS


AWG. #18 AWG. #16 AWG. #14 AWG. #12
4 4 4 4

(e) 4” square, deep, flush (f) double-gang, flush

2-1/8” Deep

MAXIMUM NUMBER OF CONDUCTORS


AWG. #18 AWG. #16 AWG. #14 AWG. #12 MAXIMUM NUMBER OF CONDUCTORS

8 8 8 8 AWG. #18 AWG. #16 AWG. #14 AWG. #12


4 4 4 4

(g) Double-gang, surface (H) NATP (Order Codes: Red 8440, White 8441)

D W

5.25”

Wire Mold or equal


Thickness: 13/64” 5.25”
MAXIMUM NUMBER OF CONDUCTORS
AWG. #18 AWG. #16 AWG. #14 AWG. #12
4 4 4 4

(j) bb backbox (order codes: Red 2830, Gray 2349)


Standard steel backbox with knockouts for interior sur-
face mounting, concealed conduit mounting or semi-flush
(i) wpbb (order code: 9014) applications. It is painted to match the signal.
4 1-1/2
1-11/16 3-3/8

5 21/32
3-3/8 #8-32 TAP
MAXIMUM NUMBER OF CONDUCTORS 3-3/8 4
(2) HOLES
AWG. #18 AWG. #16 AWG. #14 AWG. #12 TOP

8 8 8 8

PROVIDED WITH KNOCKOUTS


FOR ½” & ¾” CONDUIT
2 19/32

MAXIMUM NUMBER OF CONDUCTORS


5 3/16 AWG. #18 AWG. #16 AWG. #14 AWG. #12
4 4 4 4
(k) wbb weather resistant backbox (l) isp2 surface adapter (order codes: Red 3194,
(order codes: Red 2959, White 2411) White 3195)
5-1/4” SQ.
Sturdy die cast housing, threaded conduit hole and knockout
for outdoor applications. It is painted to match the signal.
5”
4-1/8” 2”
TAPPED 3-3/8”
FOR ½”
CONDUIT
0-1/4”
¼” DIA. 3 45/64 4 5/32
(2) HOLES 3/8” 4-1/8”

2-1/16” 29/32

½” KNOCKOUT MAXIMUM NUMBER OF CONDUCTORS 4 5/32


AWG. #18 AWG. #16 AWG. #14 AWG. #12
4 4 4 4 1 3/16

(m) iob backbox (Order Codes: Red 5046, White 5047) (N) dbb backbox (Order code: 2955)
KNOCKOUTS FOR ½” CON- Standard steel backbox provided with knockouts for interior
DUIT (TOP, BOTTOM) surface mounting, concealed conduit mounting or semi-flush
applications. It is painted to match the signal.
4
3-3/8 2-3/16
2-5/8

5-21/32 #8-32 TAP


5-1/4 SQ. 3-3/8 4
3-3/8 SQ. (2) HOLES
TOP

PROVIDED WITH KNOCKOUTS


FOR ½” & ¾” CONDUIT
2-5/8 MAXIMUM NUMBER OF CONDUCTORS
MAXIMUM NUMBER OF CONDUCTORS
AWG. #18 AWG. #16 AWG. #14 AWG. #12
AWG. #18 AWG. #16 AWG. #14 AWG. #12
8 8 8 8
8 8 8 8

(o) rp-R retrofit plate (order code: 5042) (p) sbb backbox (order codes: Red 3204, White 3193)
For surface mounting speakers, chimes, and electronic
5-7/8 13/32 5-9/16 3-9/16
3-3/8

3-3/8 3-13/16 5-1/2 3-3/8


8

3-3/8 ¾” KNOCKOUTS ½” KNOCKOUTS


(EACH SIDE) (EACH SIDE)

MAXIMUM NUMBER OF CONDUCTORS


AWG. #18 AWG. #16 AWG. #14 AWG. #12
3-13/16
8 8 8 8

(Q) 4” square deep w/ extension ring, flush (R) sfp semi-flush plate (order codes: Red 2957,
White 2958)
Stamped aluminum surface wall plate which mounts behind the
basic unit and serves to cover recessed backboxes in semi-flush
mounting applications. It is painted to match the signal.
6 5/16
See Note 6 2-1/8” DEEP 3-3/8

EXT. RING 1-1/2” 2-1/8”


DEPTH
AWG. #18 8 8
#8-32 6
AWG. #16 8 8
TAP (2) 3-3/8
AWG. #14 8 8
HOLES
1-1/2” DEEP
36
Mounting
(s) ap adapter plate (order code: 2961) (T) wPSBB (Order Codes: KNOCKOUTS FOR
½” CONDUIT (TOP,
Stamped aluminum adapter plate designed for applications Red 9751, White 3033) BOTTOM)
where semi-flush installations cannot be used. The plate can
be mounted to standard octagon or round backboxes single
or double gang boxes or plaster rings. The
backbox and 6
basic unit are 5/16 5 21/32
then fastened 3-3/8 3-3/8
to the plate. TOP
This type
mounting is
referred #8-32
to as a TAP (4)
concealed HOLES 3-3/8 6 2 19/32
conduit
installation.
It is painted
to match 5 3/16
the signal.
MAXIMUM NUMBER OF CONDUCTORS
AWG. #18 AWG. #16 AWG. #14 AWG. #12
8 8 8 8

(U) 5” Square backbox w/ extension ring, (v) ssb-4 ceiling support bridge (order code: 3380)
flush (bo) 5” Provisions for (4) J-nuts #8-32 ib 3-3/8” square
Material: Steel

5” 2 - 7/8”
5”
6-1/2”

Rhandl Industries
or equal 5”
23-3/4”

(w) 411/16” square, deep surface (b0) (x) shbb square, surface backbox (order
codes: Red 7254, White 7255)

11/16
1-9/16

1/2
5
3-3/8

3-3/8
MAXIMUM NUMBER OF CONDUCTORS 5
AWG. #18 AWG. #16 AWG. #14 AWG. #12
10 10 10 10

(y) ser-R SQUARE SEMI-FLUSH EXTENSION RING (z) sbl-2 backbox (order codes: Red 6988,
(Order Codes: Red 3045, White 3049) White 6989)
1 11/16 6 7/64
11-16 3-3/8
1-9/16"

5"
3-3/8
3-3/8"

10 15/16

3-3/8" 5"
(AA) E50SB (Order Codes: Red 0230, White 0231) (EE) E60 Extension Ring (Order Code: Red 3578,
White 3757)

(BB) E50SSB (order Codes: Red 0232, White 0233)


(FF) ZBB (Order Codes: Red 6063, White 6037)

(CC) ssb-8 8” ceiling support bridge (order


code: 3573) (GG) WFP Plate (Order Codes: Red 4696, White 4697)
23.750 TY P 
10.000

7.956

1 .0 0 0 T Y P

1 0 .0 0 0 7 .9 5 6 8 .5 0 0 1 4 .4 6 3
 

8.500

(DD) CBb-8 8” ceiling Speaker Backbox (hh) WFPA Plate (Order Codes: Red 4696, White 4697)
(order code: 3314)  


12-5/16
9-3/4

4-1/16


11-1/4

Backbox dimensions for mps


38 4-3/4” H x 3-1/4” W x 2-1/4” D
Mounting

NFPA-72 Section 4-4.4 “Wall Mounted Appliances shall be mounted such that the entire lens is not less than 80” (2.03m) and
not greater than 96” (2.30m).”
“Exception: Appliances installed in sleeping areas shall comply with 4-4.4.3.” Not included in this document.

ADA 4.28.3 (6) states that “strobes shall be 80” from the finished floor or 6” from the ceiling”.
Series RSSP Series Z and Series MT and
Series AS/AH Flush and Surface Series NS RSS AMT Multitone Exceder
Audible Strobe Horn Strobe
Retrofit Plate Strobe Strobe
Backbox Mounting Options* 80 IN 6 IN 80 IN 6 IN 80 IN 6 IN 80 IN 6 IN 80 IN 6 IN 80 IN 6 IN
(B) 1-Gang x 2” Deep - Flush (BO) 77 ½ 8 ½” 78 3/8” 7 5/8” 79 1/8” 6 7/8” 78 ½ 7½
(D) 4” x 4” x 1.5” Deep - Flush (BO) 77” 9” 83 15/16” 77 7/8” 8 1/8” 78 5/8” 7 3/8” 79 15/16” 6 1/16” 78 8
(E) 4” x 4” x 2.125” Deep - Flush (BO) 77” 9” 83 /16”
15
77 /8”
7
8 /8”
1
78 /8”
5
7 /8”
3
79 /16”
15
6 /16”
1
78 8
(F) 2-Gang x 3.5” Deep - Flush (BO) 77 ½” 8 ½” 78 3/8” 7 5/8” 79 1/8” 6 7/8” 80 9/16” 5 7/16” 78 ½ 7½
(G) 2-Gang x 1.75” Deep - Surface (BO) 77 ½” 8 ½” 78 3/8” 7 5/8” 79 1/8” 6 7/8” 80 9/16” 5 7/16” 78 ½ 7½
(M) IOB Surface & Weatherproof (WSI) 79 3/8” 6 5/8”
(P) SBB Surface (WSI) 79 1/4” 6 3/4”
(Q) 4” x 4” x 2.125” Box w/ 1.5” Extension
Ring - Flush (BO)
(U) 5” Square Backbox w/ Extension Ring, 69 ½” 8 ½” 83 7/16” 77 3/8” 7 5/8” 78 1/8” 6 7/8” 79 7/16” 5 9/16”
Flush (BO)
(X) SHBB (WSI) Shallow Surface 76 ½” 9 ½” 77 3/8” 8 5/8” 78 1/8” 7 7/8”
(Y) 4” x 4” x 1.5” Box w/ 1.5” Extension Ring
Plate (BO)
(Z) SBL-2 Surface (WSI) 78”
(FF) ZBB 78 1/8” 7 7/8”

Series SA-70S
Series CH70 Series ET80 Series E70 Series ET70 Self Amplified
Chime Strobe Speaker Strobe Speaker Strobe Speaker Strobe Speaker Strobe
Backbox Mounting Options* 80 IN 6 IN 80 IN 6 IN 80 IN 6 IN 80 IN 6 IN 80 IN 6 IN
(P) SBB Surface (WSI) 77 ¾ 8 ¼” 79 3/16” 6 13/16” 77 ¾” 8 ¼” 77 ¾” 8 ¼” 79 3/16” 6 13/16”
(Q) 4” x 4” x 2.125” Box w/ 1.5” Extension 77 ½” 7 ½” 80 6” 78 ½” 7 ½” 78 ½” 7 ½” 80” 6”
Ring - Flush (BO)
(U) 5” Square Backbox w/ Extension Ring - 78” 7” 79 ½ 5 ½” 78” 7” 78” 7” 79 ½” 5 ½”
Flush (BO)
(X) SHBB (WSI) Shallow Surface
(Y) 4” x 4” x 1.5” Box w/ 1.5” Extension Ring 78 ½” 7 ½” 80” 6”
Plate - Flush (BO)

* Measured from Bottom of Backbox


NOTES:
(BO) = By Others
(WSI) = Wheelock Product
MOUNTING NOTES
Caution: The mounting options figures show the maximum number of field wires (conductors) that can enter the backbox used with each mounting
option. If these limits are exceeded, there may be insufficient space in the backbox to accommodate the field wires and stresses from the wires could
damage the product. Although the limits shown for each mounting option comply with the National Electrical code (NEC), Wheelock recommends use
of the largest backbox option and the use of approved stranded field wires whenever possible, to provide additional wiring room for easy installation
and minimum stress on the product from wiring.
Caution: Check that the installed product will have sufficient clearance and wiring room prior to installing backboxes and conduit, especially if sheathed
multiconductor cable or 3/4” conduit fittings are used.
1. Mounting hardware for each mounting option is supplied.
2. Conduit entrances to the backbox should be selected to provide sufficient wiring clearance for the installed product. When extension rings are
required, conduit should enter through the backbox, not the extension ring. Use Steel City #53151 (1-12” deep) or #53171 (2-1/8” deep) extension rings
(as noted in the mounting options) or equal with the same cut-out area.
3. When terminating field wires, do not use more lead length than required. Excess lead length could result in insufficient wiring space for the
appliance.
4. Use care and proper techniques to position the field wires in the backbox so that they use minimum space and produce minimum stress on the
product. This is especially important for stiff, heavy gauge wires and wires with thick insulation or sheathing.
5. Do not pass additional wires (used for other than the appliance) through the backbox “unless the backbox is of a sufficient size to permit additional
wiring as described in NEC 314.16 (B)”. Such additional wires could result in insufficient wiring space for the appliance.
1 2 3
1. Series SM87 2. Series XB11 3. Series XB16
• Ideal for harsh environmental • Certified Strobes, ideal for use • Listed Strobes, ideal for
conditions, on shore or off in potentially explosive gas use in potentially explosive
shore and dust atmospheres atmospheres/harsh
• Red finish • Red or black finish environments
• NEMA 4x & 6, IP66 & 67 • NEMA 4x & 6, IP66 & 67 • Red or black finish
• Certified temperature: -67°F • Certified temperature: -67°F to • NEMA 4x & 6, IP66 & 67
to 158°F 158°F • Certified temperature: -67°F
• 4 wire monitored connection • 4 wire monitored connection to 158°F
• 24 & 48 VDC • 24 VDC and 110 & 120 VAC • 4 wire monitored connection
• 110, 120, 240 & 254 VAC • Output 29 candela • 24 & 48 VDC and 110, 120,
• Approvals: UL, cUL for Class • Approvals: UL, cUL for Class I, 230, 240 & 254 VAC
I, Div 1, Groups C & D, CSA Div 2, Groups C & D • 285 candela
Certified • Approvals: UL*, cUL for
Class I, Div 2, Groups A, B,
C&D
• UL 1971 version available

Order Codes/Model Numbers Order Codes/Model Numbers Order Codes/Model Numbers


109200-002 SM87 BAUL024CN4L- 109201-002 XB11UL02406CNBNNNR 109202-001 XB16UL02460RYNN
4RNNR 109201-001 XB11UL02406RNBNNNR 109202-002* XB16US02460CYNR
109200-001 SM87HXBAUL024RN4L- 109201-004 XB11G02406CYBNNNR
4RNNR

*UL Listed Explosion Proof


& Hazardous Location
Signals for Fire Alarm
Applications
Horns: UL 464
Strobes: UL 1971
Speakers: UL 1480

Additional models are available. Contact customer service for more information.
40
Explosion Proof & Hazardous
Location Strobes & Warning Lights

4 5 6
4. Series XB15 5. Series XB12 6. Series XB4
• Certified Strobes, ideal for • Certified Strobes, ideal for • Ideal for use in potentially
use in potentially explosive use in potentially explosive explosive atmospheres and
atmospheres/harsh atmospheres/harsh harsh environments
environments environments • Red finish
• Red or black finish • Red or black finish • NEMA 4x & 6, IP66 & 67
• NEMA 4x & 6, IP66 & 67 • NEMA 4x & 6, IP66 & 67 • Certified temperature: -67°F to
• Certified temperature: -67°F • Certified temperature: -67°F 158°F
to 158°F to 158°F • 4 wire monitored connection
• 4 wire monitored connection • 4 wire monitored connection • 24 & 48 VDC and 110 & 240
• 24 & 48 VDC and 110, 120, • 24 & 48 VDC and 110 & 240 VAC
230, 240 & 254 VAC VAC • 355 candela
• 330 candela • 355 candela • Approvals: UL, cUL for Class I,
• Approvals: UL, cUL for Class • Approvals: UL, cUL for Class Div 1, Groups C & D
I, Div 2, Groups A, B, C & D I, Div 2, Groups C & D

Order Codes/Model Numbers Order Codes/Model Numbers Order Codes/Model Numbers


109203-013 XB15DM02406RWBNR 109204-001 XB12UL02406CN- 109205-001 XB4ULB8D2E3E-
109203-004 XB15UL02406AWBNR BNNNR 06ANRN1R

109203-007 XB15UW02406CNPNR 109204-002 XB12UL02406RN- 109205-002 XB4ULB8D2E3E-


BNNNR 06ANCN1R
Series SM87 Series XB12
DC AC 50/60 Hz DC AC 50/60 Hz
Voltage 24 48 110 120 220 240 254 Voltage 24 110 240
Peak Current XB12 Tube Energy
320 170 250 275 120 135 150 21 21 21
Consumption (mA) (Joules)
Effective Intensity 29 29 32 39 32 39 44 Peak Current
1400 350 185
Consumption (mA)
Tube Energy 5 5 6 7 6 7 8
Effective Intensity 355 355 355

Series XB11 Series XB4


DC AC 50/60 Hz
DC AC 50/60 Hz
Voltage 24 110 240
Voltage 24 110 240
XB11 Tube Energy
5 5 5 XB4 Tube Energy
(Joules) 21 21 21
(Joules)
Peak Current
320 100 60 Peak Current
Consumption (mA) 1400 350 185
Consumption (mA)
Effective Intensity 29 29 29
Effective Intensity 355 355 355

Series XB16 Series SM87


DC AC 50/60 Hz
Voltage 24 48 110 120 220 240 254
XB16 Tube Energy
10 10 10 10 10 10 10
(Joules)
Current (mA) 890 300 380 380 220 220 180
Effective candela (cd): 285 at 60 f.p.m.
UL 1971 on axis output: 15 cd
Multiplying factor for Red Blue Amber Green Yellow
colored lenses: 0.15 0.12 0.51 0.49 0.86

Series XB15
DC AC 50/60 Hz
Voltage 24 48 110 120 220 240 254
XB15 Tube Energy
15 15 15 15 15 15 15
(Joules)
Current 780 670 400 400 200 200 170
Effective candlepower (cd): 330 (Effective candlepower is the intensity that
would appear to an observer if the light was burning steadily)
Multiplying factor for Red Blue Amber Green Yellow
colored lenses: 0.15 0.12 0.51 0.49 0.86

42
Specifications
Explosion Proof & Hazardous
Location Strobes & Warning Lights

Series XB11 Series XB12

Series XB16

Series XB4

Series XB15
Explosion Proof & Hazardous
Location Horns, Speakers & Combo Unit

1 1. Series DB1 Horn


2 33. Series DB4 Speaker
4
• Light weight, flameproof horn • Suitable for use in all gas groups including hydrogen
• NEMA 4x, IP66 • NEMA 4x & 6, IP66 & 67
• Up to 103dBA output @ 10 ft. • 109dBA output at 25 watts @ 10 feet
• Certified temperature: -13°F to 158°F • Certified temperature: -67°F to 158°F
• 27 output tones, user selectable • 8, 15 and 25 watt versions
• Approvals: UL, cUL for Class I, Div 1, Groups C • Approvals: UL, cUL for Class I, Div 2, Groups A, B,
& D, NFPA 72 Compliant C&D
Order Codes/Model Numbers Order Codes/Model Numbers
109206-001* DB1PULA024D1D2NNNR 109208-001* DB425ULXN2CRZ
109206-002* DB1HPULA024D1D2NNNR
109208-002* DB415ULXN2CRZ
109206-003* DB1HPULA024D1D2NNNG
109208-003 DB48ULXN2CRZ
109206-004* DB1PULA024D3D2NNNR

2. Series DB3 Horn 4. Combo Units (Audio/Visual)


• Light weight all Glass Reinforced Polyester (GRP) • Mounted on sturdy, drilled, painted stainless plate
• High ingress protection • Single input operates both horn and strobe
• NEMA 4x & &, IP66 & 67 • IP 66 & 67
• Up to 108dBA output @ 10 ft. • Strobe available as Xenon, filament, fluorescent or
• Certified temperature: -67°F to 158°F LED
• 27 output tones, user selectable • Horn: Up to 115dBA output at 1 meter
• Approvals: UL, cUL for Class I, Div 2, Groups A, B, C & D
Order Codes/Model Numbers
Order Codes/Model Numbers
109209-001 XB11/DB425 ULX(70)CLR/RED
109207-001 DB3UL048N2CNRZ
109207-002 DB3DG048N1BNR 109209-002 XB11/DB3 UL24 CLEAR RED

*UL Listed Explosion Proof


& Hazardous Location
Signals for Fire Alarm
Applications
Horns: UL 464
Strobes: UL 1971
Speakers: UL 1480

Additional models are available. Contact customer service for more information.
44
Explosion Proof & Hazardous
Call Points, Bells, & Relays

5
5. Series PB & PG Call Points
6 7
7. CVX/CSX Explosion Proof Bells
8
• NEMA 4x & 6, IP66 & 67 • Listed for Service in Division 1 applications
• Up to 103dBA output @ 10 ft. • 10” Size
• Certified temperature: -13°F to 131°F • Indoor and outdoor models
• In line and end of line resistors fitted • 24 VDC and 115 VAC models
• Retained stainless steel cover screws • Single stroke and vibrating
• Approvals: UL, for Class I, Div 2, Groups A, B, C & D, • Approvals: UL, CSFM, MEA, CSA
Class 1, Zone 2 and Class II, Div 2, Groups F&G, CSA
Order Codes/Model Numbers
Order Codes/Model Numbers 0167 CSXG10-115-S
109210-002 PBEG5B0DSN7R 3402 CSXG10-24-R
109210-010 PBUL5C4DSD7R 0134 CVXG10-115-S

8. Series XRT Relay


6. Series SM87 PBL Call Point
• Easy to install and maintain • Precision built of extremely rugged
• NEMA 4x & 6, IP66 & 67, NFPA 72 Compliant materials for long, trouble free life in
• Certified temperature: -67°F to 158°F hazardous locations
• Marine grade alloy • Low voltage AC or DC
• Robust yet lightweight • Switch 115 and 220 volts AC at 60Hz or
• UL Listed, CSA Certified, Class I, Div 1, Group C 115 volts DC with contact arrangement
& D, Class I, Zone 1 • Single-pole, normally open, double A
Order Codes/Model Numbers • FCC registered
109211-002 SM87PBLAUL3T3B3NNR Order Codes/Model Numbers
0221 XRT-T-40
Series DB1 Horn Series DB3 Horn
DB1(P)=93±3dB(A) (86±3dB(A) for 12V DB1). Sound Output: DB3 105 ±3dBA typical at 10 feet (tone dependent)
Max Sound Levels: DB1H(P)=100 ± 3dB(A) @ 10 feet
Note: Sound level is dependent upon the tone selection. Weight: 13.2 lb.
DB1P 7.7lb./3.5 Kg approx. Voltage: Up to 48 VDC, Up to 254 VAC
Weight:
DB1HP 12.3lb./5.6 Kg approx. Volume control:
Certified Temperature: –13°F to +158°F (–25°C to +70°C) Nominal Output
Input Current (mA)
(dBA)*
Ingress Protection: NEMA 4x, IP66 83 50
Tone Selection: 27 Tones 95 100
1 Alt Tones 800/970 Hz at 1/4 sec. 15 554 Hz for 0.1S/440 Hz for 0.1S 98 150
2 Sweeping 800/970 Hz at 7 Hz 16 Int 660 Hz 150 mS on 150 mS off 101 200
3 Sweeping 800/970 Hz at 1 Hz 17 Int 660 Hz 1.8 sec. on 1.8 sec. off 102 250
4 Continuous at 2850 Hz 18 Int 660 Hz 6.5 sec. on 13 sec. off 104 300
105 350
5 Sweeping 2400-2850 Hz at 7 Hz 19 Continuous 660 Hz Output measured with 24V input voltage. Tone set to 970 Hz
6 Sweeping 2400-2850 Hz at 1 Hz 20 Alt 554/440 Hz at 1 Hz continuous
7 Slow Whoop 21 Int 660 Hz at 7/8 Hz
Current Consumptions:
8 Sweep 1200-500 Hz at 1 Hz 22 Int 2850 Hz 150 mS on 100 mS off
9 Alt Tones 2400/2850 Hz at 2 Hz 23 Sweep 800-970 Hz at 50 Hz V I
10 Int Tones of 970 Hz at 1 Hz 24 Sweep 2400-2850 Hz at 50 Hz 12 VDC 760 mA
11 Alt Tones 800/970 Hz at 7/8 Hz 25 3x970 Hz pulses 0.5 off, 1.5 off 24 VDC 380 mA
12 Int Tone at 2850 Hz at 1 Hz 26 3x2850z pulses 0.5 on/0.5 off, 1.5 off 48 VDC 190 mA
110 VAC 135 mA
13 970 Hz at 1/4 sec. on 1 sec. off 27 Int 3100 Hz 0.3 sec. on 0.7 sec. off
120 VAC 124 mA
14 Continuous at 970 Hz
220 VAC 68 mA
Labels: Duty and Tag labels optional 230 VAC 65 mA
Entries: Up to 3 x 1/2” or 3/4” NPT 240 VAC 62 mA
254 VAC 59 mA
Terminals: Suitable to accept up to 12AWG conductor size

Series PB & PG Call Points Series SM87 PBL Call Point


Ingress Protection: NEMA 4x & 6, IP66 & 67.
Ingress Protection: NEMA 4x & 6, IP66 & 67.
Terminals: 6 x 14 AWG standard (BGUL), 7 or 9 x 14 AWG standard.
Switch Rating (1 or 2 changeover switches fitted): Max Terminals: Will accept up to 14AWG cable
Rating 240VAC, 3A. Switch Rating: 2 amp, 2 pole c/o, wired to terminals
Cable Entries: Up to 4 entries 1⁄2” NPT. Cable Entries: Up to 4 entries 1⁄2” or 3/4” NPT.
Weight: 2.6 lb/1.2kg (Varies with model & entries). Weight: 5.5 lb/2.5kg (Varies with model & entries).
Material: Glass reinforced polyester. Material: LM25 TF Marine Grade Alloy
Finish: Red epoxy painted finish as standard or to Customer’s Finish: Red epoxy painted finish as standard or to
specification. Customer’s specification.
Resistors: Various configurations available on versions up to 24V, Resistors: 470R minimum.
470R minimum.
Optional Indicator: A red high intensity LED can be fitted for alarm
LED Indication: A high intensity red LED can be fitted as an optional extra indication
to indicate operation on versions up to 24V.
Labelling: BG Glass label – reads either Certified Temperature: -67°F to 158°F

(1) Fire Break glass – press here.


(2) Break glass – press here.
(3) Worded to Client’s requirements.
CVX/CSX Bells
PB & BG Duty label – worded to Client’s requirements. Riveted on. Input Current 115 VAC dBA @ 10 ft.
PB & BG Tag label – worded to Client’s requirements. Screwed on. 0.220 90

Input Current 24 VDC 115 VAC dBA @ 10 ft.


0.500 0.125 87

46
Specifications
Explosion Proof & Hazardous Location
Horns, Speakers, Call Points , & Relays

Series SM87 PBL Call Point Series DB3 Horn

Series PB & PG Call Points Series DB1 Horn CVX/CSX Bells


10.25

6.63

ACCEPTED FOR USE


MODEL NO.
VOLTS
AMPS

11.30

Combo Unit
IP Fact Sheet

What are IP ratings? Is it truly an international standard?


IP is an abbreviation for Ingress Protection. It is Most countries outside Europe or North America use the
a standard for electrical enclosures. The ratings IEC Standards as a basis for their own national standards.
refer to the equipments ability to allow solids and The Russian Federation certifies equipment to GOST ‘R’
liquids into its enclosure. The IEC (International standards, these closely follow CENELEC practice.
Electrotechnical Commission) defines these un-
There is a scheme in place which will when fully adopted
der standard 60529.
allow for internationally recognized certification to become
The ratings are always displayed as two numbers. a reality, this is the IEC EX SCHEME. This uses the
The first number refers to the protection against IEC standards and IEC recognized test and certification
solids and the second number is protection bodies to issue mutually recognized test reports and
against liquids. certificates. The scheme is in its infancy and its level of
success cannot yet be measured.

How does this differ from NEMA ratings?


NEMA (National Electrical Manufacturers
Association) also considers other items such
as corrosions, rust and construction details.
Because of this, it is possible to say a NEMA
Type is similar to an IP rating, but the inverse North American practice is to use NEMA
is not possible. It is not possible to state an standards to describe ingress protection:
IP rating is similar to a NEMA Type.
NEMA 3 is similar to IP 54
NEMA 4 is similar to IP 55
What do the numbers represent? NEMA 4x is similar to IP 56
2 digits are used to denote NEMA 6 is similar to IP 67
the level of ingress protection
that a piece of apparatus
enjoys:
IP

Solids Liquids
0 No protection 0 No protection
Protected against solid objects up to 50mm,
1 1 Protected against vertically falling drops of water
e.g. hands
Protected against solid objects up to 12mm, Protected against water spray up to 15 degrees
2 2
e.g. fingers from vertical
Protected against solid objects up to 2.5mm, Protected against water spray up to 60 degrees
3 3
e.g. tools from vertical
Protected against solid objects up to 1mm, Protected against water sprays from all
4 4
e.g. wires directions
Protected against dust. (No harmful
5 5 Protected against water jets from all directions
deposits)
Protected against strong water jets from all
6 Totally protected against dust 6
directions
Protected against immersion between 15cm and
7
1m in depth
Protected against long immersion under
8
pressure

48

Hazardous Environmental Classification









 
 
 
















  
  
 















 
  
  
 


1
1. SAFEPATH Voice Evacuation System
2 2. SAFEPATH Audio Splitter
• Supervised Emergency Voice Evacuation, • Enables a single supervised speaker audio output
Paging, Messaging and Background music to drive up to two Class A or 4 Class B supervised
system speaker audio outputs
• Can be fully integrated with the WAVES MNS
system for wide area indoor/outdoor alerting Model Order Code Description
• 8 standard messages Supervised 2-Zone Class A or 4-Zone
• Live Microphone override SP4Z-
9900 Class B Speaker Audio Splitter for the
A/B
• Real-time monitoring and reporting of all system SP40S, SP40/2 or Audio Boosters
components Mounting Bracket for the SP4Z-A/B
SP-
• Approvals: UL Standard 864, 9th edition, UL MB4Z
9907 is required when used with the Audio
Standard 1711, CSFM, MEA, FCC Part 15 Boosters

Model Order
Description
Number Code
 
Single channel system with 40 watts of supervised audio
power and 2 amps of supervised 24 VDC synchronized
SP40S 9929
strobe power and 8 standard messages. (batteries not in-
cluded, 2 required) Red Enclosure
SP40S-B 9935 Same as above but with Black Enclosure 0/7%2 /.
3934%-
42/5",%
!#
42/5",%
!,!2-
!#4)6%
342/"%
!#4)6%

-%33!'%3

BAT-1212 7390 12 volt, 12-ampere hour battery



SP40S-PMK 9936 SP40S 8 Message Programmed Message Kit
42/5",%
3),%.#%

2%#/2$

AM-SP40S-SMK 9937 SP40S After Market 8 Message Standard Message Kit

AM-SP40S-PMK 9938 SP40S After Market 8 Message Programmed Message Kit


3 50 % 2 6) 3 % $ ! 5 $) / &! # ) , ) 4 9 % 1 5 ) 0 - % . 4

AM-SP40S-NBT 9939 SP40S After Market Narrow Band Signal Tone Kit
C.O. Port Adapter for the SP40S - Recommended 24 VDC
SP-COA 9908
Power Supply is Wheelock RPS-2406 (Order Code 3770)

50
Indoor Communications Systems and
Accessories

3
3. SAFEPATH Audio Boosters
4 4. SAFEPATH Addressable Paging Splitter &
• Designed to provide for additional supervised audio Telephone Zone Controller
power for live voice, pre-recorded messages or • Designed for the ability to access individual
background music or multiple speaker zones throughout the
• Available in 320, 160 and 80 watt versions SP40S system via telephone
Model
Order
Description
• Custom user programmable
Code
Model Order Code Description
320 Watt Supervised Audio Power Booster (Four
SPB-320 9918 SP4Z-APS 9920 Addressable Paging Splitter
80 watt circuits)
320 Watt Supervised Audio Power Booster (Four SP4-TZC 9921 Telephone Zone Controller
SPB-320-B 5591
80 watt circuits)
SP4-TZC Programming
160 Watt Supervised Audio Power Booster (Two TZC-USB 9923
SPB-160 8989 Cable
80 watt circuits), red enclosure
160 Watt Supervised Audio Power Booster (Two Speaker Splitter Mounting
SPB-160-B 9930
80 watt circuits), black enclosure SPMB4Z 9907 Bracket for SPB-320, SPB-
160 or SPB-80/4
80 Watt Supervised Audio Power Booster with
SPB-80/4 8988 4 Amps of Supervised and Synchronized Strobe
Power (Two 2 Amp circuits), red enclosure
80 Watt Supervised Audio Power Booster with
SPB-80/4-B 9931 4 Amps of Supervised and Synchronized Strobe
Power (Two 2 Amp circuits), black enclosure
Applications:
SPB-80/4 and SPB-160 SPB-320 Mass Notification
Dimensions: 21”H x 16” W x 6” D Dimensions: 36”H x 24” W x 6” D Emergency Notification
Weight: 36 lbs. (without batteries) Weight: 80 lbs. (without batteries) Voice Evacuation
   
Indoor Warning
Natural Disaster Alerting/Relief
Industrial Disaster/Alerting/Relief
General Paging
Background Music


1 2 3
1. SAFEPATH Volume Control 2. SAFEPATH Remote Microphone
• Allows manual volume setting for • Provides for an additional microphone in a remote location
telephone paging and background • Can be mounted up to 2,000 feet away from the SP40S
music for a specific speaker or • Supervised hand held push to talk microphone
speaker zone
Model Order Code Description
Model Order Code Description Remote Microphone for use with the SP40S,
SPRM 8996 SP40/2, SPB-320, SPB-160, SPB-80/4 or
Supervised Volume Control SP4-RMX, red plate
SP-SVC 9926 for use with the SAFEPATH
system General Paging Microphone for use with the
SPRM-GP 9927
SPB-320, SPB-160, or SPB-80/4, black plate

3. SAFEPATH Remote Microphone Expansion Module


53
V O LU ME
4
5
6
• Expands one remote microphone from the SP40S to
3

2
7

8
three remote microphones
118
1
0 10
9
• Can accept a line level input coupled with a contact
63 closure for broadcasting of other information
• OSHA 1910.165, ADA, and UFC compliant
118
Model Order Code Description

Remote Microphone
SP4-RMX 9919
Expansion Module

Emergency Mass Notification Appliance (EMNA)


A combination speaker strobe and strobe appliance for visual and voice
alerting in Emergency Communication applications.
• Mass Notification Systems
• Hazard warning/alerting
• Security alert indication
• Personnel alerting Contact customer service for more information

52
SAFEPATH Accessories

4
4. SAFEPATH Local Operator Console
5 6
6. Series NPS Push Stations
• Designed for indoor use with the SAFEPATH • Designed for manual activation of SAFEPATH
panels for mass notification applications voice evacuation systems
• Contains SAFEPATH SPRM remote microphone • Available in five colors: Blue, green, red, white,
and push-on/push-off buttons or yellow
• Can be mounted up to 2,000 feet away from the • Polycarbonate faceplate
SAFEPATH panel • ADA Compliant
Model Num-
• Mounts to single gang electrical box
Order Code Description
ber
Order
Surface Mount Local Operator Model Number Color Description
SP4-LOC-SB 4120 Code
Console
NPS-R 9767 Red
Flush Mount Local Operator
SP4-LOC-FB 4121 NPS-G 9768 Green
Console Push Station for
NPS-Y 9769 Yellow manual message
HVAC Emergency Shutoff activation
SP4-LOC-KIT 4122 NPS-W 9770 White
Switch Kit
NPS-B 9771 Blue
Push Station Normally
5. SAFEPATH LEMD Display NPS-NO 0523
Open Contact
• Illuminated text sign designed to comply with Push Station Normally
NPS-NC 0524
requirements for mass notification systems Closed Contact
• Ideal for over the door of egress stairwells or
other locations
• Two messages: Announcement or evacuate
• Steady or flashing message
• Meets IP 65 rating, sealed against dust and
protected from water splashes Mounting Hole Caps (2)
1/2" Knockout (3)

Model Number Order Code Description D6 D5 D4


J4
D3
IN OUT

D2

LEMD 5528 LED Emergency Message Display Front Cover


D2

IN OUT
D3
J4
D4 D5 D6

Releases
LED Emergency Message Display
LEMD-M 6334 • UL Listed under Standard 48
• UFC Compliant 4-021-01 ANNOUNCEMENT Circuit Board and
Backplane removal
Screws (2)
Dimensions: EVACUATE
6 1/2”H x 14 1/2 W” x 2” D (LEMD)
8”H x 14 1/2 W” x 2” D (LEMD-M)
Alert Lettering Appliances
Strobes, Horn Strobes, Speaker Strobes and Multi-Tone Horns

The Wheelock appliances with ALERT


lettering are designed for notifying
employees or personnel in military,
government and industrial applications.
They are ideal to comply with the UFC
(Unified Facilities Criteria) for Mass
Notification systems and for emergency,
warning or trouble notification in many
industrial operations.

Lens Base Lettering Agency


Wall Models Part Number Candela
Color Color1 Color2 Approval3
E70-24MCW-ALW 114124 Multi-15,30,75,110 clear White Red UL 1480, 1971, FM
E70A-24MCW-ALW 117203 Multi-11,22,56,82 Amber White Red UL 1480, 1638, FM
ET70A-24MCW-ALW 116277 Multi-11,22,56,82 Amber White Red UL 1480, 1638, FM
ET90A-24MCC-ALW 110277 Multi-11,22,56,82 Amber White Red UL 1480, 1638, FM

RSSA-24MCW-ALW 124019 Multi-11,22,56,82 Amber White Black UL 1638, FM


RSSA-24MCW-ALW 128013 Multi-11,22,56,82 Amber White Red UL 1638, FM
RSSPA-24MCW-ALW 106093 Multi-11,22,56,82 Amber White Red UL 1638, FM

Ceiling Models
E90-24MCC-ALW 114189 Multi-15,30,75,97 clear White Red UL 1480, 1971, FM
E90A-24MCC-ALW 115900 Multi-11,22,56,71 Amber White Black UL 1480, 1638, FM Note 1: Models available with red
RSS-24MCC-ALW 124004 Multi-15,30,75,95 clear White Black UL 1480, 1971, FM base, may be subject to minimum
quantity order.
Weatherproof Models Note 2: Models available with no let-
ET70WPA-2475W-ALW 110275 56 Amber White Red UL 1480, 1638, FM tering, may be subject to minimum
RSSWPA-2475C-ALW 124800 56 Amber White Red UL 1638, FM quantity order.
RSSWPA-2475W-ALW 125214 56 Amber White Red UL 1638, FM Note 3: UL 1638 models tested to
UL 1971 standards.

Also Available - Colored Lens Strobe Appliances


Strobes, Horn Strobes, Speaker Strobes and Multi-Tone Horns
• Approvals include: UL 1638
• Amber Lenses have been tested to meet UL 1971 light distribution
• Choice of strobe lens colors – amber, blue, red (some models or by special order)
• Field selectable candela settings of 15/30/75/95cd or high intensity models with 115/177cd settings
• Indoor 24VDC models with UL “Regulated Voltage” at 16-33 VDC using filtered DC or unfiltered FWR
input voltage
• Weatherproof strobe notification appliances 12 VDC
• Multitone appliance
• Strobes can be synchronized with Wheelock’s SM or DSM sync modules or power supplies
• Combination speaker/strobes available for voice messages with visual alerting
• Mount to standard electrical boxes
• High quality designs from the leader in fire notification alarms

Contact Customer Service for ordering information

54
Additional Products Available
For more details contact your sales or customer service representative

Series UTA Telephone Alerts Series TB TelBells

Loud, attention getting electronic ringers Designed for use as telephone ringers

Designed for use in noisy locations or wide area coverage Aluminum bell housing

Color: Gray Shell Size: 6”

Four selectable sound patterns: Horn, Bell, Vibrating Integral RFI suppression
Chime, Single Chime
Screw terminal connections and RJ-11 plug
Tamper resistant volume control
Approvals: UL Listed, DOC
Dip switch selectable
Tamper resistant volume control
Low current draw and REN
Weatherproof backbox for indoor/outdoor mounting
Approvals: UL Standard 1950, CSA, IC, DOC

Series PS Telestrobes Series CH Chimes and Series WR Warble

Designed for alerting the hearing impaired in high High quality, compact signaling devices
ambient noise environments, quiet hospital zones,
libraries and broadcast studios Easily connect to phone systems

High intensity flashing light Enables loud telephone alerts in noisy environments

Single line phones Color: Gray

RJ-11C modular plug-in connection Connects with standard RJ-11C phone jack

Long life, low power consumption Adjustable tone and volume

Easily mount to interior surfaces Indoor use, surface mountable

Approvals: UL Standard 1459, CSA Analog, AC and DC models

UL 1459 Listed, FCC part 68 approved and DOC


certified
Headquarter Location FL Location VA Location
273 Branchport Ave. 7565 Commerce Ct. 4401 Wilson Blvd., Ste. 220
Long Branch, NJ 07740 Sarasota, FL 34243 Arlington, VA 22203
P: 800-631-2148 P: 941-487-2300 P: 877-459-7726
F: 732-222-8707 F: 941-487-2389 F:703-294-6560
F&S Catalog 11/09

Cooper Notification is