FSR 2225547 271220230833
FSR 2225547 271220230833
FSR 2225547 271220230833
CENTAR - 9251676
Date: 27 Dec 2023
Service Details
Class recommendations:
The ship/installation has been surveyed in accordance with the relevant Rules and Statutory Regulations and the items examined as indicated hereon were found
good unless otherwise indicated on any attached sheets. It is recommended that the class be maintained with new records of survey as shown subject to any
conditions imposed now or previously being dealt with as recommended.
2191028 International Certificate of Fitness for the Carriage of Dangerous Chemicals in Endorsed 30 Dec 2027
Bulk
2191028 Cargo Ship Safety Equipment Certificate (Harmonized) Endorsed 30 Dec 2027
2191028 Cargo Ship Safety Radio Certificate (Harmonized) Endorsed 30 Dec 2027
2224415 Cargo Ship Safety Construction Certificate (Harmonized) Endorsed 30 Dec 2027
2225547/02 Record of Construction and Equipment for Oil Tankers (Form B) Issued -
AI-S-013 ASBESTOS ONBOARD (AOB) - At Annual Surveys, Surveyor to confirm maintenance of Amended -
Asbestos Management Plan (AMP).
AI-S-018 NOT LATER THAN AT THE FIRST ANNUAL, INTERMEDIATE OR RENEWAL MARPOL AIR Closed -
SURVEY, WHICHEVER IS THE FIRST, ON OR AFTER 1 JANUARY 2023, THE SHIP'S
INTERNATIONAL ENERGY EFFICIENCY CERTIFICATE (FORM 1953), OR STATEMENT OF
COMPLIANCE (FORM 1952) ARE TO BE REISSUED AND ASSOCIATED RECORD OF
CONSTRUCTION (FORM 1951) IS TO BE UPDATED BY COMPLETING SECTIONS 5, 6 AND 9.
SEE MARPOL ANNEX VI AS AMENDED BY MEPC.328(76).
AI-S-019 NOT LATER THAN AT THE FIRST ANNUAL, INTERMEDIATE OR RENEWAL MARPOL AIR Closed -
SURVEY, WHICHEVER IS THE FIRST, ON OR AFTER 1 JANUARY 2023, A VERIFIED EEXI
TECHNICAL FILE IS TO BE CONFIRMED ONBOARD, WHERE APPLICABLE. SEE MARPOL
ANNEX VI AS AMENDED BY RES. MEPC.328(76), AND '2021 GUIDELINES ON SURVEY AND
CERTIFICATION OF EEXI' - RES. MEPC.334(76).
Narratives
AS ANNUAL
Annual Survey now satisfactorily carried out. Relevant checklist completed in all respects and retained into local file. Certificate of Class endorsed accordingly.
The affected below listed sections along with associated shell plate, deck plate, stiffeners were partially cropped and renewed as per the approved construction
drawings and dealt with as necessary by using certified steel plates, approved welding procedures, qualified welders and approved consumables.
Subsequent to repair, the new steel plantings and welding were visually examined, UT and Vacuum tested as applicable and considered satisfactory.
-Bulwark plate btw Fr.210 - Fr.220 Port Side together whit attached stiffeners and brackets,
-Forecastle Deck Plate Fr.209-Fr.216 Port Side together whit attached stiffeners and brackets,
Refer to HRPS1.
The vessel's management company and owner changed with following details;
Registered Owner:
Company ID: 6410987
Name: CENTAR SHIPPING LTD.
Address: TRUST COMPANY COMPLEX, AJELTAKE ROAD, AJELTAKE ISLAND, MAJURO, REPUBLIC OF THE MARSHALL ISLANDS, MH96960
Registered Manager:
Company ID: 6421346
Name: SREDISTE SHIPPING GEMI ISLETMECILIGI ANONIM SIRKETI
Address: BARBAROS MAH. SARKAC SOKAKAGAOGLU MY PRESTIGE NO:1/46ATASEHIR, ISTANBUL, TURKIYE
The Interim IHM certificate re-issued at this time due to vessel owner and management company change, the full term IHM certificate to be issued by Panama Flag.
The report marked for vetting in order to remove the only "+" notation from descriptive note SHIPRIGHT (IHM-EU+) and class certificate has been re-issued without
"+" at this time.
Additionally, full term IHM certificate to be issued by Panama without annual endorsement (Renewal IHM survey cycle should remain on the class status)
Safety Radio Periodical survey was completed satisfactorily. The GMDSS survey check list, inspection reports of AIS & SSAS, EPIRB and Radar Transponders filled by
approved service supplier were reviewed, endorsed and left onboard.
Upon owner request modification has been carried out. PV Breaker line has been extended 200 mm, therefore pressure has been increase form 2100 Pa to 2300 Pa.
Upon owner's request STS and SMPEP has been re-approved by LR and related section of the From B has been amended and IOPP Certificate & Form B have been
re-issued.
The vessel's EEXI Technical File has been examined and related Actionable items (EEX & ETI) closed by the attending surveyor on 10 July 2023 with MAST Report No.
2206689
VOC manual detail at the IAPP Records has been amended and IAPP Certificate and its Supplement have been re-issued.
BWM Annual Survey has been carried out satisfactorily and Panama Flag issued related BWM certificate 1st annual section has been endorsed accordingly on behalf
of the Flag Administration.
The report was marked for vetting due to vessel current flag is PANAMA and IHM certificate issued by flag administration (without annual endorsement) therefore
IHM annual survey cycle is not applicable and which has to be removed from the class status (Renewal IHM survey should remain)
At the owner's request, thorough examination and annual tests of the below listed cranes were carried out satisfactorily at this time.
- One (1) Provision Crane, located on 2nd House Deck starboard side at Frame No.58 & SWL 1.5 MT
- One (1) Engine Room Overhead Crane, located above Main Engine & SWL 3.0 MT
- One (1) Monorail Trolley Crane, located on Main Deck port side at Frame No.54 & SWL 3.0 MT
CoC-H-001
UPON COMPLETION OF INTERNAL AND EXTERNAL EXAMINATION OF THE PORT SIDE FORECASTLE DECK AND FORE BULLWARK FOLLOWING WERE NOTED AND
CONTINUED SATISFACTORY REMAIN EFFICIENT IN MEAN TIME AND NO FURTHER ACTION CONSIDERED NECESSARY AT THIS TIME;
1. FORWARD SHELL PLATING IN WAY OF PORT SIDE FORE BULLWARK BETWEEN FR NO. 210- 219 PORT SIDE APPROXIMATELY 12000X750X10.5 mm.
2. FORE BULLWARK BETWEEN FR NO. 210-219 PORT SIDE 2 PIECES APPROXIMATELY 12000 mm 200 HP
3. FORE BULLWARK FR NO. 211 AND 216 WEB FRAMES ON PORT SIDE.
4. FORECASTLE DECK PLATE BETWEEN FR. NO 210-219 PORT SIDE 2170X2950X14mm, 1000X950X14 mm, 1050X700X14 mm PLATES.
5. BOSUN STORE PORT SIDE BETWEEN FR. 211-216 5 PIECES 160X 700 mm LONGITUDINAL STIFFENERS.
6. BOSUN STORE PORT SIDE FR NO.211 AND 216 2 PIECES 350X400X10 mm BRACKEST.
Attending surveyors
Ozgur Gundemli
Lloyd's Register Group Limited, its subsidiaries and affiliates and their respective officers, employees or agents are, individually and collectively, referred to in this clause as ‘Lloyd's Register’. Lloyd's Register assumes
no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a
contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.
Lloyd's Register - Final Survey Report 4
CENTAR - 9251676 Report number: 2225547, Version: 1
Date: 27 Dec 2023
Appendix 1 - Tasks
Table of contents: