AAA App Notes
AAA App Notes
AAA App Notes
5m
2.5m
Detection limit 2.5 pmol (S/N=2, Asp)
Analyzer
Column Size: 4.6 mm ID × 60 mm ※ PC Installation
600 mm
Resin: Hitachi custom ion exchange resin LA8080 main unit site (Table) or
PC Rack
Pump Flow rate setting: 0.001 – 1.000 mL/min
Discharge pressure: 0 – 34 MPa
Gradient elution method with 6 solutions
Autosampler Injection method: Direct injection method
Sample vial capacity: 1,500 µL
No. of vials accommodated: 120
(with optional cooling unit installed: 100)
≥ 1,000 mm
Sample injection volume: 0.5 – 100 µL
Column oven System: Peltier
Temperature setting: 20 - 90 ˚C (in 1 ˚C steps)
Reaction unit System: Electronic heating
Temperature setting: 50 - 140 ˚C (in 1 ˚C steps)
Detector Spectrophotometer: Aberration-corrected
concave diffraction grating
Wavelength: 570 nm, 440 nm
※ Standard column
*This logo is the trademark of Hitachi High-Technologies Corporation throughout the world.
CAUTION: For correct operation, follow the instruction manual when using the instrument.
Specifications in this catalog are subject to change with or without notice, as Hitachi High-Tech Science Corporation continues to develop the latest
technologies and products for its customers.
NOTICE: The system is For Research Use Only, and is not intended for any animal or human therapeutic or diagnostic use.
These data are an example of measurement; the individual values cannot be guaranteed.
www.hitachi-hightech.com/global/hhs/
Head Office
24-14, Nishi-Shimbashi 1-chome, Minato-ku, Tokyo 105-0003, Japan
Feel of the “Ease of use” stability cultivated over many years. The product was realized from users’ perspectives with the aims to provide a better usability for
beginner operators and a more comfortable operating environment.
With consideration for the work Space-saving compact Use of highly reliable and
and motions of operators based design (System setup area stable post-column nihydrin
on the ergonomic concept. was reduced by about 30 %). method.
Designed with consideration for the operational Compact design with the unchanged reliability and stability The analysis methods are compatible with ones of conventional
perspectives, daily work, and motions of users. of the dedicated system. models, L-8800 and L-8900.
■ Consideration for operability and safety ■ Space-saving Design ■ Reliability and stability cultivated over many years
While retaining the conventional front access design, By optimizing the locations of the flow channel system and As the analysis methods are inherited from conventional
the height of the reagent setup unit was adjusted for main unit internal module, the compact (system setup area models, the basic analytical conditions, columns (packing
better accessibility. It is devised to ensure the smooth reduced by about 30 %) system was realized. materials), and reagents that have been in use can be used
operation of daily tasks such as reagent replacement without making any changes.
and sample setup and maintenance, and the work Internal structure
performed in a half-sitting position has been minimized Reagent box
■ Post-column ninhydrin derivatization method
(The front door is also removable). Detector
By using the ninhydrin reagent which gives a characteristic
Nitrogen gas color reaction with amino acids, highly selective analysis
control unit
without the interference by contaminants (components other
than amino acids) in samples can be achieved.
Reliability and stability of Hitachi amino acid analyzer Reaction unit
55 years since the product launch. After achieving high speed, Flow line diagram
high resolution, and computerization, AminoSAAYA was born.
Column oven
Autosampler
Ninhydrin
reagent
Model L-8900
Easy operation was Pump
achieved
Select and use the analysis column (column, analysis conditions) depending on the purpose.
Either the "Standard analysis method" or "Physiological fluid analysis method" can be selected depending
on the analyte in the sample, analysis time, resolution, etc.
たん白質加水分解物分析法
Protein (標準分析法)
hydrolyzate analysis method (standardと生体液分析法
analysis method) and physiological fluid analysis method Analysis Examples by Various Analysis Methods
■ Protein hydrolyzate analysis method (30 min) ■ High resolution standard analysis method (80 min)
Protein hydrolyzate analysis method (standard analysis method) Analysis of amino acids as
Nutrients Analyte: amino acids of protein hydrolyzate Analyte: amino acids of protein hydrolyzate
nutrients in food products
Analysis for constituent amino acids of protein
(approx. 20 components)
Response (mv)
Response (mv)
Analysis of nutritional values of
Fertilizer
amino acids contained in
Pretreatment feedstuff
(extraction, fertilizers or fodders
Protein hydrolyzation) Constituent amino Amino acid measurements
acids of protein of composition and amount
Analysis of medicinal amino acids used Retention Time (min) Retention Time (min)
Response (mv)
Response (mv)
etc. deproteination) of amount
Analysis Column and Analysis Time Retention Time (min) Retention Time (min)
* STANDARD ANALYSIS COLUMN (Part No. 855-4506) * HIGH RESOLUTION PH TWIN COLUMN (Part No. 855-4360)
Based on the amino acids (amino acids as analytes) contained in samples, analysis time, and resolution, select the analysis
The performic acid oxidation allows the analysis of CySO3H By using the twin-column, high-resolution analysis is available
method (PH or PF) and analysis column from those listed below. (cysteic acid) and MetSON (methionine sulfone). relatively fast.
855-4506 STANDARD ANALYSIS COLUMN #2622, 4.6 mm × 60 mm 30 ■ Physiological fluid analysis method (110 min) ■ High-speed physiological fluid analysis
Analyte: Free amino acids method (60 min) Analyte: Free amino acids
855-4360 HIGH RESOLUTION PH TWIN COLUMN #2622, 4.6 mm × (40+40) mm 45
Response (mv)
Response (mv)
Part No. Product Name Remarks Time (min)
855-4507 PHYSIOLOGICAL ANALYSIS COLUMN #2622, 4.6 mm × 60 mm 110 Retention Time (min) Retention Time (min)
855-4420 HIGH RESOLUTION PF TWIN COLUMN #2622, 4.6 mm × (40+40) mm 125 * PHYSIOLOGICAL ANALYSIS COLUMN (Part No. 855-4507) * HIGH SPEED PF TWIN COLUMN (Part No. 855-4600)
42 components including the protein-constituting amino acids By reducing the pressure loss of each column to about a half, the
Note) Ammonia filtering column is neccesary for the usage.
can be simultaneously analyzed. Suitable for the analysis of free twin-column enable the high-speed analysis.
* The most suited combinations for general-purpose analysis are PH method + STANDARD ANALYSIS COLUMN and PF method + amino acids (amino acids found in physiological samples).
PHYSIOLOGICAL ANALYSIS COLUMN.
Simple operation by various special screens Operational friendliness
たん白質加水分解物分析法
Sample (標準分析法)
information entry and と生体液分析法
method selection Data Analysis screen
Status
Screen for automatic reagent amount calculation function User-friendly instrument status screen