PHYS3040 Laboratory Molecular Spectroscopy 2024v2
PHYS3040 Laboratory Molecular Spectroscopy 2024v2
PHYS3040 Laboratory Molecular Spectroscopy 2024v2
Molecular Spectroscopy
1 Introduction
Atomic spectroscopy is the study and use of of the unique frequency (or wavelength) profile of the electromagnetic
spectrum absorbed or emitted by a substance. You will be familiar with atomic spectroscopy from earlier study.
In this practical, we focus on molecular spectroscopy, which is substantially more complicated (and interesting!)
than the atomic case, due to the extra degrees of freedom. In particular, you will investigate diatomic iodine,
one of the simplest molecules able to exhibit phenomena unique to molecular spectroscopy.
Learning Goals
• Appreciate the different spectral features arising from electronic, rotational and vibrational degrees of
freedom.
• Relate observed patterns to the mathematical description and the relevant quantum numbers.
• Use derived model and experimental data to predict known quantities of diatomic iodine; the vibrational
frequency ωe and anharmonicity constant ωe xe .
• Demonstrate laboratory procedures, including the use of lab books and record keeping, proper and justified
procedure, and error control and propagation.
Session 1 Aims
By the end of session 1, you should have
• Collected broad spectrum results for both the green and orange wavelengths.
• Attempted to observe a double peak
• Completed the mathematical model and have this checked over by a tutor. Between sessions 1 and 2, you
should map your observed spectrum to the predicted. Session 2 should be largely devoted to attempting
to filling in any gaps.
If you are nearing the end of your first session an have not completed these steps, please contact a tutor.
2 Experiment
Equipment
This experiment consists of a vial containing a sample of diatomic iodine, a helium-neon laser used to excite the
sample, and an Andor Solis spectrometer to record the resulting emission spectra. You are tasked to control
the spectrometer and optimise the emission spectra for at least two excitation wavelengths.
1
The default set up (as demonstrated in the video on Blackboard) is to use a tunable laser, capable of emitting
light over a range a frequencies. Two excitation wavelengths most useful for inducing fluorescence in the iodine
are 543.003 nm (green) and 611.971nm (orange). The frequency is controlled by the knob on the back of the
laser (see Figure 1).
The alternative set-up uses different fixed-frequency lasers to excite at different wavelengths. Please consult
your tutor for how to swap between the different lasers.
Most of the controls you need are in the Andos Solis software program, installed in the laboratory computer.
Figure 2 shows what you should see when you open the screen.
The various software controls in Figure 2 are:
1. This leads to save and export options. You should export the collected data as an ASCII file, for later
import to e.g. MATLAB.
2. This button starts the acquisition of data, which will be displayed on the screen. The data will not be
saved or recorded automatically. You must start an acquisition, stop an acquisition (see 11) and then
export the data you wish to use.
3. This button starts a run of acquisition according to acquisition parameters, as set by 5. This acquisition
will stop automatically, but will still need to be exported or saved.
4. Stops the acquisition.
5. Acquisition set-up. You can then specify all the parameters which will be used when running acquisition
(see 3). In particular, you can define the vertical binning range. The vertical size of the CCD matrix of
the photo detector is 256 pixels. By default, the spectrum is obtained by adding the signal in in all pixels
in the vertical column. This increases the number of detected photons but reduces the spectral resolution
because the optical aberration in the system causes distortion and the entrance slit is not imaged properly.
6. Re-scale for fit vertically in the screen.
7. Start/stop auto-scaling.
8. Click to set the temperature of the spectroscopy detector (CCD). The recommended temperature is -70◦ C.
You will know when it has reached the set temperature once it is coloured blue, as indicated in this image.
Once it has stabilised you can start acquisition.
9. The grey bar indicates the observed spectral region, and can be shifted up and down in frequency by
clicking and dragging. The width of spectrum is set by the choice of grating (see 11).
10. The dots indicates the range of sensitivity of the CCD sensor.
11. Displays the grating choice. You can select a different one by clicking on the corresponding coloured bar.
The available gratings are numbered from 1 to 4 clockwise:
2
Figure 2: The Andor-Solis Software
3
Figure 3: To open the correct menu, choose the Spectography Setup option in the hardware menu, and then
make sure the settings match the picture above before clicking ’OK’
Figure 4: When correctly calibrated, the range of the grey bar will match the range displayed on the given
graph. This is important, as this represents how the exported data will be labelled.
For Investigation
We want to determine a model to predict the measured spectral lines, and then verify its ability to do so for a
simple diatomic gas, I2 . Consider the simple approximation of a diatomic molecule as two atoms connected by
a spring. The spectral lines of a molecule are must more complex than that of an atom due to the additional
degrees of freedom. Along with changes in atomic shell, diatomic molecules can also be subject to vibrations
and rotational energy changes. The total energy can thus be written:
which gives the total energy in terms of familiar electron excitation energy T (n), the vibrational energy G(v),
and the rotational energy F (J), labelled with their respective quantum numbers n, v, and J.
1. By modeling a diatomic molecule as two masses on a massless spring creating an anharmonic oscillator,
determine the energy levels dependant on quantum number v as
where ωe is the frequency in units of cm−1 , and xe is a constant related to the anharmonicity. Support
for this task and that below are given in these notes.
2. By modelling the diatomic molecule as a rigid rotator, determine the rotational energy levels in terms
of rotational quantum number J. You should include a second order approximation to account for any
4
Figure 5: To calibrate the display and export data, halt all acquisitions, then under the Calibrate menu, choose
the X-Calibration by Spectrograph, and choose confirm ’Calibrate’ on the resulting pop-up window.
stretching in the molecule. As above, divide by hc to give an expression for energy in units cm−1 :
5
Figure 6: Schematic diagram of molecular energy levels, showing vibrational and rotational structure.
Figure 7: Vibrational potential curves for different models: SHO (dashed line); actual potential curve (solid
line; drawn for the ground state of HCl); anharmonic oscillator (dotted line). (From Ref [1] p. 91)
The energy of a given rovibrational level is then the sum of its electronic, vibrational, and rotational components,
E = Eel + Eosc + Erot . We will examine each type of motion separately, before putting them together to obtain
the energy levels of a vibrating rotator.
where νosc is the vibrational frequency calculated classically and v can take integer values 0,1,2,.... It is clear
from eqn 5 that this model leads to equally spaced vibrational energy levels.
This model is unrealistic for large internuclear spacings. In a real molecule, in contrast, there is no restoring
6
force experienced once the atoms are infinitely separated, which implies that the potential curve should level
off as the internuclear spacing increases (see Fig 7).
A better approximation to the real potential curve is to treat the molecule as an anharmonic oscillator, basically
by adding a cubic term on to the potential energy expression, to obtain
2 3
V = a (r − re ) − b (r − re ) (6)
where r is the internuclear spacing, re is it’s equilibrium value, and β ≪ α. The corresponding energy levels
are given by
2
1 1
Evib (v) = hνosc v + − hνosc xe v + (7)
2 2
We divide through by hc to obtain what is known as the vibrational term value for a given vibrational energy
level 2
1 1
G (v) = ωe v + − ωe x e v + (8)
2 2
with ωe = νosc
c known as the vibrational frequency, and ωe xe known as the anharmonicity constant. Both ωe
and ωe xe have units of cm−1 ; as does therefore the term value G. (One of your main aims in this prac will be
to determine ωe and ωe xe for I2 .) From eqn 7 we see that the separation between the levels of an anharmonic
oscillator decreases as v increases.
Thermal distribution of vibrational levels Continuing to consider only vibrational levels of a molecule,
we now examine the probability that, at thermal equilibrium, a molecule will be in a particular vibrational
state. This comes to the same thing as asking about the number of molecules in each state when we observe a
large number of molecules (as is the case in many spectroscopy experiments).
We might expect molecules to tend to ‘fall to the bottom of the potential well’ (i.e. the bottom of the anharmonic
potential curve) and thus sit in the lowest vibrational state. Think of little beads in a bucket shaped like the
potential curve. At temperatures above absolute zero, however, the molecules will have some thermal energy;
this is equivalent to the beads ‘bouncing around’ inside the bucket and results in some beads being found higher
up in the bucket. In other words, above T = 0 K, some molecules will occupy higher vibrational states.
The probability of a molecule occupying a given state is governed by what is called the Boltzmann distribution.
(You will hear a lot more about this in your statistical
mechanics course. For more information, see Ref [3] p. 220-
227) Specifically, this probability goes as exp −E
kT where E is the energy of the level, k is Boltzmann’s constant,
and T is the temperature in K. Hence N , the number of molecules in a vibrational state with a vibrational
quantum number v decreases exponentially
Evib
N ∝ exp − (9)
kB T
This is also shown for I2 in Fig 8.
The influence of temperature on vibrational level populations means that we can extract temperature infor-
mation from vibrational spectra by examining the relative intensities of different emission lines. Spectroscopic
measurements are often used to measure temperature in inaccessible samples, like hot gases.
h2
Erot (J) = J (J + 1) (10)
8π 2 I
where I is the moment of intertia, and J can take integer values 0,1,2,.... The spacing between energy levels
described by eqn 6 increases quadratically with J. Dividing eqn 6 through by hc again gives us the corresponding
term value, designated F for rotational energy levels
h
F (J) = J (J + 1) = BJ (J + 1) (11)
8π 2 cI
7
Figure 8: Thermal distribution of vibrational levels according to the Boltzmann factor. (Here, vibrational
energies correspond to the ground state of I2 at T = 300 K. From Ref [1] p. 122.)
where B is the rotational constant and is inversely proportional to the moment of inertia.
We know, however, that our molecule is not a rigid rotator: rather than comprising two point atoms joined
by a massless rod, we have modelled it as two points joined by a massless spring. Our first refinement to
eqn 11 consists of adding in the possibility that the spring could stretch during rotation. Indeed, this is exactly
what will occur as a result of centrifugal forces as the rotation increases. By equating the centrifugal force
to the restoring force that will result from the small stretching, we can find the new equilibrium internuclear
distance, and thus derive a correction to eqn 11 (see Ref [1] p 104-105 for details). This takes the form of adding
higher-order terms, as we did with the vibrational energy levels. We obtain
2
F (J) = BJ (J + 1) − DJ 2 (J + 1) + . . . (12)
where D is another rotational constant and is small compared to B. D gives a measure of the influence of
centrifugal force on the molecular energy. In terms of the energy-level spacings, the quadratic correction of
eqn 12 is mainly significant at higher rotational energy levels (or larger values of J).
Finally, we have to consider the effect of simultaneous vibration and rotation on our model, which will essentially
manifest in the values of the rotational constants B and D. Recall that B is inversely related to the rotator’s
moment of inertia. As the molecule vibrates, B will therefore vary, because the molecule’s moment of inertia
depends on its internuclear spacing. To a first approximation, B then takes the form
1
Bv = Be − αe v + + ... (13)
2
where we have used the subscripts v and e to distinguish the vibrating (v) rotator from its rigid, or equilibrium
(e), counterpart. αe is a constant that is small compared to Be . (We won’t go any further into how to derive
eqn 13 as Ref [1] describes the calculations as “rather involved”.) A similar relation obtains for Dv , which then
also depends on vibrational number v.
Substituting these vibration-corrected constants into our rotational term value expression of eqn 12, we obtain
its final form of
2
F (J) = Bv J (J + 1) − Dv J 2 (J + 1) + . . . (14)
The full term value for a rovibrational energy level is simply the sum of electronic (Te ), vibrational, and
rotational term values, or
2
1 1 2
T = Te + ωe v + − ωe x e v + + Bv J (J + 1) − Dv J 2 (J + 1) (15)
2 2
where n is the electronic quantum number. Don’t forget that T has units of cm−1 .
8
3.2.3 Thermal distribution of rotational levels
Just like for the vibrational states, the Boltzmann factor also regulates the thermal distribution of molecules
in rotational states. However, we must also take into account that each rotational level is actually (2J + 1)
degenerate. In other words, there are actually multiple levels (to the number of (2J + 1)) with rotational
quantum number J, so all with the same rotational energy. (These levels split in the presence of an external
magnetic field, however, an effect known as Zeeman splitting.) This multiplicity of levels means we have to
multiply the Boltzmann factor by the number of levels (2J + 1) in order to obtain the distribution of molecules
in those states. You can think that more levels means there is a greater probability of a molecule being in that
state. The consequence for the thermal distribution is that it no longer declines exponentially with energy as
for the vibrational levels. Therefore there is a peak of population at some J, depending on the temperature
and the value of the rotational constants.
3.3.1 Nomenclature
By convention, we designate the upper rovibrational level in any transition by quantum numbers v ′ and J ′ ,
while the lower state is designated v ′′ and J ′′ . Therefore a given vibrational transition is written v ′ –v ′′ (eg.
26–0). This form does not change regardless of whether the transition involves absorption or emission.
As for the rotational part of transitions, we denote transitions with ∆J = −1 by the letter R, while transitions
with ∆J = +1 are termed the P branch. The difference in J is calculated here relative to the lower state.
Thus a transition denoted R(5) will have J ′ = 6 and J ′′ = 5, while P(5) will have J ′ = 4 and J ′′ = 5. This is
illustrated schematically in Fig 9.
9
Figure 9: Schematic illustration of molecular transition nomenclature. (Based on Ref [2] Fig. 13.36)
4 Tables
Note that in the tables (overpage), the electronic and vibrational terms are already combined into the value Ev ,
with Ev = Telec + G (v) − G (0). Tables 1 and 2 are also provided on Blackboard as Excel spreadsheets (only
v ≤ 28 for Table 1) to simplify importation into Matlab; just open the files with the uiimport command.
References
[1] Herzberg, G., Molecular Spectra and Molecular Structure. 2nd ed. Vol. 1: Spectra of Diatomic Molecules.
1950: Van Nostrand. [QC451.H463 v.1]
[2] Atkins, P. and J. de Paula, Atkins’ Physical Chemistry 2006: Oxford University Press. [QD453.A88]
[3] Schroeder, D. V., An Introduction to Thermal Physics. 2000, San Francisco: Addison Wesley Longman.
[QC311.15 .S32]
[4] Williamson, J. C., Molecular Iodine Fluorescence Spectra Generated with Helium-Neon Lasers for Spectrom-
eter Calibration. Applied Spectroscopy, 2010. 64(12): p. 1419-1422.
[5] Gerstenkorn, S. and P. Luc, Description of the Absorption Spectrum of Iodine Recorded by Means of Fourier-
Transform Spectroscopy – The (B-X) System. Journal de Physique, 1985. 46(6): p. 867-881.
[6] Lerner, J. M. and A. Thevenon, The Optics of Spectroscopy: A Tutorial. Horiba Scientific. [accessed 4 March
2014]; Available from: http://www.horiba.com/us/en/scientific/products/optics-tutorial/
[7] Paschotta, R., Spectrometers. Encyclopedia of Laser Physics and Technology [accessed 4 March 2014]; Avail-
able from: http://www.rp-photonics.com/spectrometers.html.
[8] Kramida, A., Ralchenko, Yu., Reader, J., and NIST ASD Team, NIST Atomic Spectra Database (ver. 5.1)
2013, Gaithersburg, MD: National Institute of Standards and Technology. [accessed 9 March 2014]; Available
from: http://physics.nist.gov/asd
10
Table 1: Energies and rotational constants of the B-state in I2 . Note that Ev = Telec + G (v) − G (0). All values
in cm−1 . (Taken from Ref [5] Table V.)
11
Table 2: Energies and rotational constants of the X-state in I2 . Note that Ev = Telec + G (v) − G (0). All values
in cm−1 . (Taken from Ref [5] Table V.)
12