0% found this document useful (0 votes)
27 views16 pages

SPO 1400 Basic Commissioning and Basic Operation 2

The document provides instructions for configuring an SPO 1400 network element using a commissioning wizard. It describes steps for basic setup including network information, user management, port configuration, synchronization settings, and communication parameters.

Uploaded by

farzad.aminzade
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
27 views16 pages

SPO 1400 Basic Commissioning and Basic Operation 2

The document provides instructions for configuring an SPO 1400 network element using a commissioning wizard. It describes steps for basic setup including network information, user management, port configuration, synchronization settings, and communication parameters.

Uploaded by

farzad.aminzade
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 16

SPO 1400 R4 Commissioning and

Basic Operation

SPO 1400 R4
Commissioning and Basic
Operation
Basic System Set-up

Chapter 2 - Objectives
› On completion of this chapter you will be able to:
– Configure SPO 1400 using the Commissioning Wizard
– Configure and analyze the communication parameters.
– Configure the unit’s parameters.
– Configure the ports’ parameters.
– Configure TDM Synchronization.

© Ericsson AB 2012 | Basic System Set-up | LZU1088965 R1A | Figure 02-1

© Ericsson AB 2012 | Basic System


Set-up | LZU1088965 R1A | Figure
02-X 1
SPO 1400 R4 Commissioning and
Basic Operation

COMMISSIONING WIZARD

Starting the Commissioning Wizard


› Connect PC to LCT connector on active SC.
› Start the LCT and login.
› From Bridge select proper bridge type (customer or
provider) and save.
› Select Equipment - Commissioning Wizard
› In each Commissioning Wizard step, click on refresh
before moving to next step.

© Ericsson AB 2012 | Basic System Set-up | LZU1088965 R1A | Figure 02-3

© Ericsson AB 2012 | Basic System


Set-up | LZU1088965 R1A | Figure
02-X 2
SPO 1400 R4 Commissioning and
Basic Operation

Basic Set-up
› Enter Network Element additional information
› If required, add users

© Ericsson AB 2012 | Basic System Set-up | LZU1088965 R1A | Figure 02-4

Time Set-up
› Define NE date and time:
– Synchronize to Workstation Time
– Synchronize to Time Protocol Server

© Ericsson AB 2012 | Basic System Set-up | LZU1088965 R1A | Figure 02-5

© Ericsson AB 2012 | Basic System


Set-up | LZU1088965 R1A | Figure
02-X 3
SPO 1400 R4 Commissioning and
Basic Operation

Shelf Configuration
› For every installed module define:
– Module mode
– Protection (if available/requested)
– Additional information

© Ericsson AB 2012 | Basic System Set-up | LZU1088965 R1A | Figure 02-6

Port Modes and Interface Modules


› Port properties for different port types:
– Administrative Status
– Capability (L1, L2, MPLS-TP) for Ethernet
– Rate for SDH
› Expected and installed interface type

© Ericsson AB 2012 | Basic System Set-up | LZU1088965 R1A | Figure 02-7

© Ericsson AB 2012 | Basic System


Set-up | LZU1088965 R1A | Figure
02-X 4
SPO 1400 R4 Commissioning and
Basic Operation

SDH Synchronization
› Synchronization sources for T0 and T4

© Ericsson AB 2012 | Basic System Set-up | LZU1088965 R1A | Figure 02-8

Alarm Configuration
› Alarm reporting options
› Configure cause, severity and persistency
› Thresholds for Degrade and Pointer Justification
› Alarms suppression criteria

© Ericsson AB 2012 | Basic System Set-up | LZU1088965 R1A | Figure 02-9

© Ericsson AB 2012 | Basic System


Set-up | LZU1088965 R1A | Figure
02-X 5
SPO 1400 R4 Commissioning and
Basic Operation

Users and Security


Equipment – NE User Management
Management Tree -> device -> users management

› Optional Radius server for authentication.

© Ericsson AB 2012 | Basic System Set-up | LZU1088965 R1A | Figure 02-10

COMMUNICATION
PARAMETERS

© Ericsson AB 2012 | Basic System


Set-up | LZU1088965 R1A | Figure
02-X 6
SPO 1400 R4 Commissioning and
Basic Operation

Protocols Summary

SPO 1400 Management

IP (ROUTING) GRE CLNP (ROUTING)

VLAN PPP PPP LAPD LAPD

LAN
CLI MNGT LCT DCC GCC DCC MCC MNGT GCC DCC
WAN
SDH SDH
DCC XC OTN OTN

© Ericsson AB 2012 | Basic System Set-up | LZU1088965 R1A | Figure 02-12

Management Interfaces
SC Management
› Management Ports MGT
RID
› LAN ports CT
LCT

› WAN Ports
SM DCC
STM-N
› DCC channels SDH
STM-N
› GCC channels
› Local Craft Terminal Ports SM
LAN
Mapper Ethernet ETH
WAN

SM
GCC
› Node is identified by RID OTN OTUx

OTS_DCC
PAU OSC
OMS_DCC

© Ericsson AB 2012 | Basic System Set-up | LZU1088965 R1A | Figure 02-13

© Ericsson AB 2012 | Basic System


Set-up | LZU1088965 R1A | Figure
02-X 7
SPO 1400 R4 Commissioning and
Basic Operation

Router ID
Router ID <ip_address>

Management Tree -> IP

yes
NM

no
MGT
CT
OSPF SPO 1400
Router ID

Router ID
Eth
I/F Mngt VLAN

SDH LCT
CT CT
DCC
IP over OSI SPO 1400 SPO 1400
Router ID Router ID

Verify DCN

© Ericsson AB 2012 | Basic System Set-up | LZU1088965 R1A | Figure 02-14

Management and LCT Port


Router ID

Management Tree -> DCN -> Management Ports

yes
NM

DCN
no NMS
<ip_address>
MGT
MGT
OSPF LCT SPO 1400
CT

Eth
I/F Mngt VLAN

SDH
DCC
IP over OSI SPO 1400 SPO 1400

Verify DCN

© Ericsson AB 2012 | Basic System Set-up | LZU1088965 R1A | Figure 02-15

© Ericsson AB 2012 | Basic System


Set-up | LZU1088965 R1A | Figure
02-X 8
SPO 1400 R4 Commissioning and
Basic Operation

OSPF
Router ID

Management Tree -> IP -> OSPF

yes
NM

no
MGT 0.0.0.1

OSPF Area 0.0.0.1


OSPF SPO 1400
OSPF Interface
OSPF

Eth
I/F Mngt VLAN

SDH
DCC OSPF
IP over OSI SPO 1400 SPO 1400
OSPF

Verify DCN

© Ericsson AB 2012 | Basic System Set-up | LZU1088965 R1A | Figure 02-16

Management VLAN
Router ID

Management Tree -> DCN -> Management VLAN -> Configure VLAN
Management Tree -> IP -> OSPF -> OSPF Interface
yes
NM

no
MGT

OSPF SPO 1400


PNP PNP

Eth L2 Ethernet
I/F Mngt VLAN
PNP

SDH VLAN ID 4093


<ip_address> PNP PNP PNP PNP
DCC
IP over OSI SPO 1400 SPO 1400

Verify DCN

© Ericsson AB 2012 | Basic System Set-up | LZU1088965 R1A | Figure 02-17

© Ericsson AB 2012 | Basic System


Set-up | LZU1088965 R1A | Figure
02-X 9
SPO 1400 R4 Commissioning and
Basic Operation

DCC IP over OSI


Router ID

Management Tree -> DCN -> Management DCC


Management Tree -> IP -> OSPF -> OSPF Interface
yes
NM

no
MGT

OSPF SPO 1400


STM STM

Eth
I/F Mngt VLAN

SDH
STM STM STM STM
DCC
Mode IP SPO 1400 SPO 1400
IP over OSI
<ip_address>

Verify DCN

© Ericsson AB 2012 | Basic System Set-up | LZU1088965 R1A | Figure 02-18

Verify Configuration
Router ID

Management Tree -> IP -> Ping


Management Tree -> IP -> Routing Table
yes Management Tree -> IP -> OSPF -> Link State Database
NM
Management Tree -> IP -> OSPF -> Neighbor

no
MGT

OSPF SPO 1400


RID 2
RID 1
RID 3
Pi
ng
Eth
I/F Mngt VLAN

SDH
DCC
IP over OSI RID 1 SPO 1400 RID 1 SPO 1400
RID 3 RID 2
RID 2 RID 3

Ping
Verify DCN
Routing Tables
© Ericsson AB 2012 | Basic System Set-up | LZU1088965 R1A | Figure 02-19

© Ericsson AB 2012 | Basic System


Set-up | LZU1088965 R1A | Figure
02-X 10
SPO 1400 R4 Commissioning and
Basic Operation

SERVICE MODULES
CONFIGURATION

Service Modules Configuration


› Management Tree – shelf
› If required set Expected Mode and wait for module
configuration:

› Verify Installed Module and Expected Mode


› For every slot verify Service State and Alarm Reporting

© Ericsson AB 2012 | Basic System Set-up | LZU1088965 R1A | Figure 02-21

© Ericsson AB 2012 | Basic System


Set-up | LZU1088965 R1A | Figure
02-X 11
SPO 1400 R4 Commissioning and
Basic Operation

PORT CONFIGURATION

Port Configuration
› Management Tree – Shelf – slot:x
› For every port listed in the tree:
– SDH Rate
– OTN Configuration
– Port Interface
– Administrative Status
– L1/L2/MPLS-TP capability for LAN and WAN
– Port TPID Settings
– Egress Port shaping for LAN/WAN
– Concatenation for WAN ports
– Provider Bridge Port Type (L2 only)

© Ericsson AB 2012 | Basic System Set-up | LZU1088965 R1A | Figure 02-23

© Ericsson AB 2012 | Basic System


Set-up | LZU1088965 R1A | Figure
02-X 12
SPO 1400 R4 Commissioning and
Basic Operation

L1 Port Configuration
› Any Ethernet port can be configured as:
– L1
– L1 VLAN-MUX
SPO 1400
SM

CVID 1 SM
L1
CVID 1 SVID 1
L1 VLAN-MUX
CVID 2 CVID 2 SVID 1
L1

© Ericsson AB 2012 | Basic System Set-up | LZU1088965 R1A | Figure 02-24

Provider Bridge Port Type (L2)

SPO 1400
SM
CEP
SM
CVID
CEP CVID SVID
PNP
CVID SVID
CNP
CVID SVID
DSLAM CNP

CEP = Customer Edge Port


CNP = Customer Network Port
PNP = Provider Network Port
© Ericsson AB 2012 | Basic System Set-up | LZU1088965 R1A | Figure 02-25

© Ericsson AB 2012 | Basic System


Set-up | LZU1088965 R1A | Figure
02-X 13
SPO 1400 R4 Commissioning and
Basic Operation

WAN Ports Configuration


› Management Tree – Shelf – slot:x – wanx.y
› Configure parameters like LAN port
› Select vcgroup:x.y
› Choose concatenation level and LCAS

Cross-connected WAN port

Configured WAN port

© Ericsson AB 2012 | Basic System Set-up | LZU1088965 R1A | Figure 02-26

MPLS-TP Port Configuration


› For each MPLS-TP Interface set peer port MAC address

SPO 1400 SPO 1400

MPLS-TP MPLS-TP

© Ericsson AB 2012 | Basic System Set-up | LZU1088965 R1A | Figure 02-27

© Ericsson AB 2012 | Basic System


Set-up | LZU1088965 R1A | Figure
02-X 14
SPO 1400 R4 Commissioning and
Basic Operation

OTN Configuration
Shelf-> Slot:x

Right Click
Port x.y
Switch to OTN Port

ODU settings
OTN:x.y SPO 1400
OUT setting
STM OTN

OTNPort
SDH or Ethernet port configuration
x.y

STM STM STM OTN


SPO 1400 SPO 1400

© Ericsson AB 2012 | Basic System Set-up | LZU1088965 R1A | Figure 02-28

CONFIGURE TDM
SYNCHRONIZATION

© Ericsson AB 2012 | Basic System


Set-up | LZU1088965 R1A | Figure
02-X 15
SPO 1400 R4 Commissioning and
Basic Operation

TDM Synchronization
Device -> Synchronization

T0 Synch
Add Source(s)
Source

E1
SPO 1400
STM STM

STM STM STM STM


SPO 1400 SPO 1400

© Ericsson AB 2012 | Basic System Set-up | LZU1088965 R1A | Figure 02-30

© Ericsson AB 2012 | Basic System Set-up | LZU1088965 R1A | Figure 02-31

© Ericsson AB 2012 | Basic System


Set-up | LZU1088965 R1A | Figure
02-X 16