SPO 1400 Basic Commissioning and Basic Operation 5

The document discusses setting up performance data collection and analyzing performance data and optical measurements on an Ericsson SPO 1400 R4 network element. It describes collecting 15 minute and 24 hour performance data for TDM, OTN and Ethernet interfaces and analyzing the data, optical power measurements, and factors that can affect Ethernet performance data.

Uploaded by

farzad.aminzade
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
21 views5 pages

SPO 1400 Basic Commissioning and Basic Operation 5

The document discusses setting up performance data collection and analyzing performance data and optical measurements on an Ericsson SPO 1400 R4 network element. It describes collecting 15 minute and 24 hour performance data for TDM, OTN and Ethernet interfaces and analyzing the data, optical power measurements, and factors that can affect Ethernet performance data.

Uploaded by

farzad.aminzade
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

SPO 1400 R4 Commissioning and

Basic Operation

SPO 1400 R4 Commissioning


and Basic Operation
Monitoring

Chapter 5 - Objectives
› On completion of this chapter you will be able to:
– Set-up the performance data collection.
– Analyze the performance data and the optical measurement.

© Ericsson AB 2012 | Monitoring | LZU1088965 R1A | Figure 05-1

© Ericsson AB 2012 | Monitoring |


LZU1088965 R1A | Figure 05-X 1
SPO 1400 R4 Commissioning and
Basic Operation

PERFORMANCE DATA

Performance Data
› 15min and 24h
› For TDM and OTN:
– Always active
– Near and far end
› For Ethernet LAN Interfaces:
– Ingress Performances always active for Ethernet Services
– RMON
– MEF 15
– Ethernet Interface Group Counter
› OSPF statistics
› RSTP/MSTP statistics
› IGMP statistics
› MSP/SNCP and Redundancy statistics

© Ericsson AB 2012 | Monitoring | LZU1088965 R1A | Figure 05-3

© Ericsson AB 2012 | Monitoring |


LZU1088965 R1A | Figure 05-X 2
SPO 1400 R4 Commissioning and
Basic Operation

Collecting Performance Data


› For RMON:
– Enable for a LAN port (24h)
– Start history collection (15min)
– Optionally activate alarms for specific RMON events
› For MEF 15 and Ethernet Interface Group Counter:
– Enable for an Ethernet Interface
› Display current sample:
– Port->sdh-> rs or ms
– Port->OTU/ODU-> perfomence or counters links
– Network Monitor ->RMON->History Control-> click on link
– Network Monitor ->MEF15->Traffic PM-> click on link
– Network Monitor-> Ethernet Interface Group Counter-> click on link
– Ethernet Services -> Ingress PM Overview

© Ericsson AB 2012 | Monitoring | LZU1088965 R1A | Figure 05-4

Ethernet Performance Data Consideration


› Affected by:
– Cabling and BER
– Queuing and policing
– Network status

© Ericsson AB 2012 | Monitoring | LZU1088965 R1A | Figure 05-5

© Ericsson AB 2012 | Monitoring |


LZU1088965 R1A | Figure 05-X 3
SPO 1400 R4 Commissioning and
Basic Operation

OPTICAL MEASURES

Optical Measures
› For every port having an optical I/F:
– Received optical power.
› Values refreshed manually.

© Ericsson AB 2012 | Monitoring | LZU1088965 R1A | Figure 05-7

© Ericsson AB 2012 | Monitoring |


LZU1088965 R1A | Figure 05-X 4
SPO 1400 R4 Commissioning and
Basic Operation

© Ericsson AB 2012 | Monitoring | LZU1088965 R1A | Figure 05-8

© Ericsson AB 2012 | Monitoring |


LZU1088965 R1A | Figure 05-X 5