ML-655M Fail-Safe - Fail-Secure Reversible
ML-655M Fail-Safe - Fail-Secure Reversible
ML-655M
Robust, Convenient & Electromechanical
The ML-655M electric lock is a high performance lock designed for single action swing doors. Featuring
a double action latchbolt and left/right side adjustable deadlatch tip, the ML-655M allows deadlocking
automatically when the door is closed to be secured for ease of use and convenience. The ML-655M
can be controlled by card readers/keypads and connected to automatic swing door operators for an
integraed access control solution.
28 28
230
125
230
125
100
150
100
150
275
250
250
275
78
78
2 2
30 et 35 et
ks ks
Bac Bac
49 ML-655M-30 54 ML-655M-35
Installation Diagram
Mortise mount (Single swing)
The product is warranted against defects in material and workmanship while used in normal service for a period of
1 year from the date of sale to the original client. The GEM policy is one of continual development and improvement;
therefore GEM reserves the right to change specifications without notice.
Unit: mm
Specification Dimension
3 3
21 21
Operating Voltage: 12~24VDC/AC ±10%
Current Draw: 250mA/12VDC; 150mA/24VDC
28
Operating Temperature: 14°F to 120°F (-10°C~+49°C) 28
230
125
100
150
230
125
100
150
275
250
250
275
Lock bolt sensor switch output: SPDT, 3A/125VAC
78
78
Latch Throw:13mm
Solenoid testing: Tested to 250,000 cycles
Resistance against door being forced : 2 2
Lock Bolt
Nib
Strike Plate
Euro profile
key cylinder hole
Version Changeable:
Take out the Screw 1 , release screw 2 , move the
position and then tighten both screws.
1
“Fail-Safe” “Fail-Secure”
(Power to Lock) (Power to Open)
2
Caution:
Do not completely remove screw 2 (as marked in the figure)
as the interior solenoid might fall off.
Unit:mm
Door Loop
(Optional)
f
Do lea
or Ø5.2 or
F ram Do
e
Ø5.2
275
250
150
150
100
28 (C
t
ylin
kse 0) de
Bac 55M-3 5) rn
ot
25 L-6 5M-3 inc
M
30 ( (ML-65 lud
e
35 d)
Attention! Please ensure
that the direction of the
template is correct
1 2 3 4
ø5.2
f a f
af Le
a Le
Fra Le f or Do
or
me or Le
a
Do
Do or
Do
Alignment CL
310
275
t
kse M)
Bac L-310 M)
(M 5
30 (ML-31
35
5 6 7 8
a f Fra
Le f me
or a
Do Le
f or
ea Do
o rL
Do
Connect power cable to the lock and test Attach the cover plates for the cylinder lock
before screwing to the door leaf. Install the cylinder Fix the strike plate.
3-2
Copyright © All Rights Reserved. P-MU-ML-655 Published: 2020.12.09
Wiring Diagram
Red
Yellow
Green
Blue
Lock bolt sensor switch output: SPDT, 3A/125VAC
NOTE: The varistor (or diode) must be connected across the terminals as shown above. This protects the
electromechanical lock from spikes and surges.