TB74 DipSetting Bengal BDT72-500 RS232 104U

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

TB74 Protocol for RS232 104U / Pulse

BDT7 Support bill 2、5、10、20、50、100、500 (Bengal)

DIP SW SETTING : 1
FUNCTION SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 SW9 SW10
★ 1 Pulse / BDT 1 OFF OFF OFF
2 Pulse / BDT 1 OFF OFF ON
3 Pulse / BDT 1 OFF ON OFF
4 Pulse / BDT 1 OFF ON ON
5 Pulse / BDT 1 ON OFF OFF
10 Pulse / BDT 1 ON OFF ON
20 Pulse / BDT 1 ON ON OFF
100 Pulse / BDT 1 ON ON ON
Lo=50ms
Fast Output Pulse ON
Hi=100ms
Lo=50ms
★ Slow Output Pulse OFF
Hi=300ms
Inhibit level Active Low ON
★ Inhibit level Active High OFF
★ Accept BDT 2 & 5 ON
Reject BDT 2 & 5 OFF
★ Accept BDT 10 & 20 ON
Reject BDT 10 & 20 OFF
★ Accept BDT 50 ON
Reject BDT 50 OFF
★ Accept BDT 100 ON
Reject BDT 100 OFF
★ Accept BDT 500 ON
Reject BDT 500 OFF
★ Default setting
Note: Please reset the bill acceptor after any changes on Dip switch.

DIP SW SETTING : 2
FUNCTION SW1 SW2 SW3 SW4
★ Pulse Normal High (NO) ON
Pulse Normal Low (NC) OFF
★ Pulse Protocol ON
RS232 Protocol OFF
Straight ON
★ Turn Over OFF
Reserved ON
★ Reserved OFF
★ Default setting
Note: Please reset the bill acceptor after any changes on Dip switch.

You might also like