Model UAP-2HS4PL4
Power supply 3~ 440V 60Hz Notes
(Control circuit) (U 220V 60Hz) *1. Cooling capacity is based on the following condition .
A Color of point 7.5 BG 7/2 A
Cooling capacity
Evaporator inlet air temp.: 27'C D.B. & 19.5'C W.B.
kW 10.6 *1
Condenser water I/ min 63 (Sea water) *2. Parenthesized figures show the weight of plenum chamber.
Head loss kPo 15
- Compressor
Model x No.
Hermetically sealed scroll
ZS21K4E-TFD x 1
-
1
Speed min- 3500
Motor output x poles kW X p 2.2 X 2
8 Starting manner Direct start 8
Condenser Water cooled shell & finned tube
Model x No. UWC-204 x 1
Tube Copper alloy low fin tube (C6B72T)
-
Evaporator Cross finned tube (Cu-tube, Al-fin)
Fan Multi blade fan
Model DBOA23-1B
Air flow rote m8/min 28.5
c External static press. kPa -
c
Motor output x poles kW X p 0.4 X 4
Drive Belt drive
- Air filter Polyvinyl chloride fiber (Washable)
I--
Refrigerant control Thermostatic expansion valve
Temperature control Thermostat
Capacity step % 10(}--0
D Protective devices Overcurrent relay, Reverse phase protection relay, D
Camp. motor protection thermostat,
Low pressure switch, High pressure switch, Fusible plug
Thermal & sound isolator Glass fiber
- Refrigerant R-404A
Charoe volume kg 2.5
Refrigeration oil EAL ARCTIC22CC
Charge volume R. 1.24
E Weight (Approx.) E
Machine weight kg 238+(10) *2
Operatino weioht kg 241+(10)
Spare parts See PA02H403
- Electric heater kW 6 IDIM. IN TITLE SCALE DATE
UAP-2HS4PL4 NON 04.06.26
I~KUJ t.L; II UN
SPECIFICATIONS
F & APPROVED ICHECKED 'DESIGNED T.No. F
·1:- E.Fujita 1 E.Fujita T.Kikugawa
12\
A\ 12.05.22 Small change on description. Y.C. A4
lf.SIZE
)~ jiJ ~ tt Jt ~ DWG No. t± ******
LC~A~R~EE~R~------~-----------L--,--------------.--------------.---~-------L-,------~US~H~IO~RE~IN~8~S~U~C~O~.~LT~D~.----~-,r-~P~A~0=2~A~4~0~5~-~R~1 ~
1 I 2 1 3 I 4 I 5 1 6 1 7 I 8
l 2 l 3 I 4 I 5 I 6
l 7 I 8
A
I
~-------
I
DBOA23-18
~
-& --~
---------,
4
p O kW
4
I
I
I
I
SYMBOL
@
EVAPORATOR
FAN
FAN MOTOR
NAME
D D
E E
1-'KUJt.CIIUN
NON 04 .06 .26
F
2 3 4 5 6 7 8
No. NAME t ~ i ~
"A" DETAIL "B" DETAIL CONDENS ER 25A SGP JIS 5K
1 WATER INLET
:UI!lf.¥/1;tJ!;j()..O FLANGE
INSTALLATION SPACE CONDENSER 25A SGP JIS 5K
A
2 WATER OUTLET :UI!lf.¥11;tJI;j(iliO FLANGE A
(NON SCALE)
UPPER DRAIN
4-<t> 15HOLES 3 OUTLET
.um.~::.-ilio 20A SGP {FPS3/4)
M12 ANCHOR BOLT LOWER DRAIN
4 OUTLET
Hm;:/iliD 20A SGP {FPS3/4)
EMERGENCY FREON ;r;~Jj;:fi~ili 15A SGP JIS 5K
5 GAS OUTLET ~~il~liW FLANGE
POWER SOURCE
6 WIRING INLET U:.!llll'A.D CABLE RUBBER CONNECTOR
MONITOR WIRING
7 OUTLET ~fsltm!ll111~11l'ilio ~ 45 KNOCKOUT
8 8 NAME PLATE ig ~ 8
,~E-1•--7'--"3'-"0_ _;r:.+i:L(
,
A NOTE: STANDARD MODEL IS
PIPED AT RIGHT SIDE
a: !t~Mt!U ~ J.Jv,
f * SHOWS THE CONDENSER * EfJJ\1iftUJ~)
WATER INLET/OUTLET 111li~l9i!Jl*)
I PIPED AT LEFT SIDE
I lll'-&i!il!3;Ji:;l.,
I PLENUM CHAMBER IS :/l;:tbil\/fjj'gjB~
: PACKED APART FROM
BlJ!Ill?!. ~ J.Jv,
c THE UNIT AT DELIVERY c
800
2-~ 15HOLES
FOR FIX
(M 12 BOLT)
AIR FILTER
SERVICE
SPACE
D D
lf)
;;
E E
0
n
8
7
4-~ 15HOLES
M12 ANCHOR BOLT
SCALE DATE
*"'~" . 1 : 20 13.06. 05 F
F ~+---~~---------------1
A A
...
- +
-~ 'r-
-ij --~~ ~ ·
I
B B
I
I
I 18 ELECTRIC HEATER t~t-J
- -
17 SIGHT GLASS illli!i~t
16 NAME PLATE ~l!i
15 HIGH PRESSURE SWITCH i/III/Jiiilr.t!Gi
c r1-4~R~EF~.~C~HA~R~G~E~P~OR~T-----+~~~~-~~~-D-----~c
3 EVAPORATOR i.~Gi
E E
2 CONDENSER lUliGi
I I 1 \ _l 1 COMPRESSOR II~I
No. NAME
- llJIM.IN SCALE DATE
TITLE UAP-2HS4Pl4/,UAP-2HF4Pl4
UAP-2HS2PL4/UAP-2HF2PL4
IPROJECTION ASSEMBLY DRAWING NON 04 .06 .26
~ ~rr~
F &. ~ APPROVED ~CHECKED 'DESIGNED T.No. F
&. £.Fujita J £.Fujita T.Kikugawa
IP.SIZE ******
& 08.05.09
CAREER
. . .IJT.K.
A4 ~~ ~~ ~ f* it ~ ~±
USHIO REINETSU CO. LTD.
DWG No.
PA028404-R1 ~
I I I
I 2 I 3 4 I 5 6 I 7 8
1 I 2 I 3 I 4 I 5 I 6 I 7 I 8
!!!
A
----- _ll UPYC-2~---------------------------------
1 1 1 A
AC440V 3!b OPERATION PANEL
50/60Hz R ST
0 0 0 TB1 HPS GL
SOURCE
-
f 660V/0.75 TR 250V/0.75
r--------,
I THR TFU
l.....a --.<1
1
I
L£J
[1E[] GG
TH 0
cs D
COS
r-
B
r::r
II)
L()
c-.i
L()
r::r
II)
c-.i
~F1-3A
----IZ!- F4- 3A
440 220
-{2}---~ z OCR1
.a .. a.
9596
0 '\§} '6' -
9596 ~,
C H C L B
~H tH
2.5sq rzrF5-3A
0 0 CONTROL PANEL
-
cs f-
J IJ (4 7 8
.
®'.
[ ] MCJ
cos 2
,.,.,c
u
::::!:c
N<
u
~(
~
u
::::!:c
(
(
RS T
I
22 ~ MC2
21!
STOP
FAN
HEAT/COOL:
COOL c HEAT ...,.8
s . • 0
c 1 6 5 1 3
ROR c
"!c ~ -
8. .. t.!Cl t.IC2
·~l~l
~
A2
5~ J 50< ~ J
•
-
0 13
14
I MC1 A2
MC3
A1 r--
~ oc~
r::r 0"
II)
L()
II)
L() 6 4 MC2
r- o --,
~
c-.i N 0
A1 OCR1
I I
I
D
r
I
r- ~- ----,
I
r
I
---- --
I
..., ICH
I
I
I
)~L
I
I • [J]
F2,F3 Fl F4F5
TBl D
. ·Bl··C3
L- 0 _J
~
I I I I L
I
lf~
I I ~2 I t1 7 H- TH I
. . .....
~
I I I ........_, ........_, I
IL. _ _ _ _ _ _JI IL... _ _ _ _ _ _ _ _ ...JI c I
- 1 •.----. ... r-----1
r-
EH1
6kW/7.9A
COMP. FAN
2.2kW/7.0A 0.4kW/1.0A
F3-3A
5 I
-1ZJ- ,g
I
E - - - BYYARD 1YPE SOURCE COMP. MAKER REFRIGERANT HEATER AIR DISTRIBUTION E
I
R2 ~.09.0
OCR1 OVERCURRENT RELAY(FAN) EH1 ELECTRIC HEATER
R1 ~.08.04 Notation changed. E.F. H.Y. E.S . OCR2 OVERCURRENT RELAY(COMP.) ROR REVERSE PHASE RELAY
P.SIZE
I-~ rf:J
'~ 111.
"" :t A.Z. DWG No. t! :rt fi
CAREER N'PR(Ml) ClEm CIWIC[J) MCJ MAGNETIC CONTACTOR(EH) A4 USHIO REINETSU CO.,LTD. PA02E4AH06-R2
c:n
1 I 2 I 3 I 4
I 5 I 6 I 7 8
6
PLAN RECORD
1. Jun. 05, 2013 DRAWN FOR THIS WORK.
S-847
" Zllflllm
tf!.Aim
I.Jm
:fflitlm
t'Hi 11~
Remarks
1-----+-1 S-847: A20287
APPROVED BY H. NISHI
······························································································································································· ............................................
CHECKED BY T. KIKUGAWA
CHARGED BY
1-----+-1 DWG. No.
A120287 02
I ALT. I REV. I CLAS~K DRAWN BY M. OKABE
-;! v
ii«Jifill
-:tttll
L
lef USHIO
-:t n T HEAD OFFICE TEL: +81-898-34-1230
1(? 1- T
.JIII:IBiffi
FAX: +81-898-34-1231
:!: illltlHiiiJi DEVELOPMENT & TEL: +81-898-34-1207
l§~ l:lHiiiJi
DESIGNING DIV. FAX: +81-898-34-1208
:~Oii I:IBI iiJi
~J± ll #1 KO 185, YATA, IMABARI-CITY, EHIME PREF., JAPAN
~J± ll #2
if.ljfj! IUI USHIO REINETSU CO., LTD.
~
7
A I B I c I D I E I F
PAGE
1
I 1
LIST OF SPARE PARTS SHIP NO.
30
FUSE IE ·I MF60
3
2
t. .l - J."
D 0~6.5 2 2 270641 3A,AC250V
(FUJI TANSHI)
3
~
S-N12
MAGNETIC (MSO-N12)
3 CONTACTOR 2 1 3102020N
AC200V, 1a 1 b
- f--
~ litt t~ ~~ ~ (MITSUBISHI)
~~
V BELT
4 4 1 1 280109 A-31 4
v "'"(Ji.J t--
-
5
PACKING
Jk ~IT!~ WI
)\ •:; .:f J
fi
.an
(]9] 1 1 100931
FOR
UWC-204HF
1---
5
6
PACKING
11 ~IT!~ ~
)\ •:; .:f J
fi
.an
n
ll_·_ _\\
\_J
0
N
N
"S
1 1 100932 FOR
UWC-204HR
5
- I• 50 •I !2.Q.j~ -
SACRIFICIAL
7 ANODE PLATE
m tt ~ foB
~an~}[]-~ Zn 2 2 300205
FOR
UWC-204
10 ·I IE
6 6
I• 75 •I !2.Q.j~
SACRIFICIAL
8 ANODE PLATE
m tt ~ foB
~+-$-+ ~]-[]-~ Zn 3 3 300206
FOR
UWC-204
-
1o ·I I· I-
PACKING
9 mtt~ ~
)\ •:; .:f J
m ~t (o) ~1 5 5 300214
FOR
UWC-204
7 7
- f--
8 .& ~==~~~~==~----~~~---4~-----L------~8
APPROVED !CHECKED DESIGNED T.No.
& £.Fujita 1 £.Fujita T.Kikugawa
~;.~~~--~~~~~~----~~
& 12.05.23 Material added. (Y.C.) A4 DWG No. ******
~~H /il ~ f! it ~ 1±
CAREER USHIO REINETSU CO. LTD . PA02H403-R 1
A I B I c I D I E I F
Operation Manual
~ fi
MODELS: UAP-1 ~7 (R404A)
UAPG-1 ~7 (R404A)
UAPG-W 1~7 (R404A)
UAPG-R 1 ~7 (R404A)
SJLJJX; 23 if. 1 A 19 s ~u
Contents Page
3
Confirmation regarding the installation work
3. 1!1! JJLI:. 0) 7± ~
Cautions for operation
Operation
11 _..___, 15
Maintenance
8. itt~~$1t'T
Trouble and countermeasures
Recommended oil 39
·~ 1YF
Name of parts
Vr<.Jvi' DX I±\ j ' 1) ) v ( ::1 LF :t b ~ )
V-belt Air discharge grille
7 7 './ m~i1J~
Lubricating port
Fan motor
77 '__;
Fan
Evaporator
Expansion valve
Air filter
JI1J~t
Pressure gouge
Operation panel
Compressor Condenser
~*&~ EE*&~tJ:. G ltl:l±l ~ ht:. ~71li~J±O)l{J-~jj 7-. ~l{J-~71< t;: ct 0 -cr~{~ ~it 0~:)(:~
Condenser ~C'T o
- 1-
life*# ~*i%i :a:-1±:1 t::. rWJ t!!;WjJ± 0)1~1~~9-lf'±, .:c 0) ~ ~ -c- f'±?fi-55%i r::i5TEn~lv -c- 'b ~ §
Expansion :a:-*t::. ~ t.t v\0) -c-, ~ 9=1f;:~Ife*# :a: 'b 5 ~t -c~EE L-, ?fi-55 L-~-tv 'f1S:7!! fE:EE 0)
valve ~9-l f;: L- ~To
Evaporates the low temperature and low pressure refrigerant which passes
through the expansion valve, taking heat from the room air drawn in from
the air suction grille.
7 7 /
Fan
Draws the room air into the air conditioner and discharges it into the room
after it was cooled by the evaporator.
m31:1. r:Prd-i :
Electric
Encases the magnetic switches, fuses, protection devices and operation
kit box
devices.
Air filter
Removes dust and dirt from the room air.
-2-
2. :tM1f~t~;:OO-t-01it~
Confirmation regarding the installation work
j:: t~,
::I /
*
£~if;v }- -c' f;: U!!J :G:: ~ .h --c v'j:: -9;6=-o T :r- '/ ~ l- --c <t'C. ~ v' o
Check whether the air conditioner is installed in such a place which bears the weight of the
air conditioner sufficiently and whether is firmly fixed to the floor with anchor bolts.
lb 1m~ f;: 'b 5~ U!!l f;: ::r. 7 :::z / ~ U!!1 :G:: T 6 t~ 'dJ f;: "'~ oo _l:_ :g1H;: U!!l :G:: t.& ~ iL ti 1 00 fi ~ L- --c :to 'J j:: T 0)
-c ~' f U!!l }:£ L- --c <t'C. ~ v\ 0
In order to fix the air conditioner firmly during pitching or rolling of a ship, be sure to use
the fixtures attached to the right and left sides of the upper rear of the air conditioner.
Check whether an independent power source is provided for the air conditioner.
fl;6=-0)'m~~-HC:f1fffl L---c:to~v'f;:f,t6
C:, 7''v~fJ~t .:z.~;(;6~-w:J.h6~.h;6~~ 'J j::To
Without a separate power source, the circuit breakers may be thrown or fuses blown.
-3-
s. ~J=tLcO)tt~
Cautions for operation
-~~rpO)t£~
Cautions for operation
·~~~w6b -c, ~v~~~oo~~T Q ~ ~ f;: l:t, ~,--r 3 :5t Yl:::to~~i? <t2: ~ "'o
Once the air conditioner is stopped, wait three minutes before restarting it.
3 :5t Yr*J f;:~~~ 00~~ L ~ T ~, ~;fflXf;:jltOiiJ~ir-iJ:dJ, t: .::z. ~ ;(~/- v~ ;tJ iJ~-;D.tLQ ;:_ ~ iJ~
(b'J~To
If the air conditioner is restarted before a lapse of three minutes, it may be overloaded
and a fuse blown or circuit breaker thrown.
•rliil.}jtWiiJ~YY" <
:3: l'i~-:::> IJ 1*1'1= L, :lCf;:mT~il-l'i, ~,f 3 JtJ;I.l:::to~~i? t2: ~ v'o <
Turn the thermostat knob slowly, and wait at least three minutes before returning it to
its original position.
• ::c 7 7-{ Jv -7 l'i~, fl& IJ fi It -c ~~ L '"( <t2: ~ v'o ::c 7 7-{ Jv -7 l'i 2 i!m F~, f;:- )jt l'i~jffl- L -c
<t2: ~ v \0
Be sure to attach the air filter before operation. Clean the air filter once every two weeks.
::c 7 7-1 ;v-7 ~ .Anttv'-c'~~ L ~ T ~, ~t15Z}J5li1:iJ~tt <tt IJ, ~11JXO)itc~f0) 'b ~ f;:tt IJ ~
To
If the air filter is not replaced, dust will gather on the air conditioner and operation will
become erratic.
- 4-
•ll&J6~~v ;v~~l±l~·-v ;vO)§fJf:::.~f~!jo/):a:W[tr>ttv'--c:'< t-!.~v'o
~:UJXf;::.~:@iJ~iJ:>iJ:> VJ, ~~fO))]j{iZ9 ~ ft VJ ~To
Do not place any obstacle in front of the air suction grille or air discharge grille, because
the air conditioner may be overloaded, which may also cause trouble with it.
·~7~~~-, ~~~-,~~~~~~O)~-tt~~~-:a:~~~O)X7~~0)~<--c:'~ffl
Lftv'--c:'< t-!.~v'o 51.1<To~.hi1~£b VJ ~To
Do not use inflammable sprays such as hair spray, lacquer, paint, etc, near the air
conditioner in operation because of danger of fire.
<
L -c v 't~ t-!. t~ ~ f;::_
e•~;R:® f;::_ ~ffl
For comfortable operation
ewmf&O)~~Noo
Restart after power failure
-5-
4. ~fiJJt:t
Operation
·~fp$0)~~
Name of control panel switches
rm!±!±tJJ.-{yf-
~~~A { ':1 f-
High-press COOL/HEAT
RESET SWITCH Pilot lamps change-over switch
0 0
~ USHIO
HPS
0 0
RUN
HEAT
0 0
Operation switch
Electric heater step
change-over switch
·~fp$0)11J~
Operation switch
l1! J!ii .A -1 '/ =r : IOFFJ IFANJ IHEAT/COOLJ O).A-1 -;;"T~@JT~, l1!J!iiw.LI:, *Jj.J1!
Operation switch J!ii, lfj- ml1!J!iiil~ --c- ~'iTo 'it:. e ~~~I& IJ fi It 6 ~ a~m~Jiiiil~ "C' ~'iTo
'furn the knob for OFF, FAN and HEAT/COOL and all functions will
stop, the fan will start, or cooling will start. If a heater is mounted,
heating is possible.
- 6-
7_ffil_ J3r ifflJ w ~ :
Thermostat
Turn it toward right when cooling is not enough and turn it toward left
when it is too cool.
WARM COLD
THERMOSTAT
*- 1F 1:T
Pilot lamp
Lights up during operation.
- 7-
-~~!$100-
Preparation for operation
Do not turn off the power switch during the operation season except when the air
conditioner is stopped for a long time, because it is necessary to energize the crankcase
heater for smooth starting.
@f%!117kffl #iJ~ ~It \-cIt \-c, x. 7 :::1 /f~FJT;ij:'O)Jk:l,:iJ~Jmlk ~ tL -cIt\ 0::. ~ ~1it~
L -c t~ ~It \o <
Check whether the water regulating valves are fully opened and condenser water is
supplied sufficiently to the air conditioner.
Of%!117k ~imlk L f.t.lt \ --c-JJ;fi-9 0 ~, 3C~~~ (!WiJ±J±jJ ~ M$:) iJ~{jfjlt \ -c~;fflXiJ~* 11: L~
To
If the air conditioner is operated without condenser water supply, the high pressure
switch (safety device) will function and stop the air conditioner.
<%!117k7kii
Condenser water flow rate:
-8-
~ f'F jJ ¥:t
Operation
•~m~~Cl) ~tPt~
Cooling
CD IFANJ ~~ '/-? ~ ~..g-:b--lt-c <t-c. ~ 1t\o
Turn the knob to "FAN".
O:l!J!I.~~~OO~fl~*To ;:_Cl)~IRUNJ 7/:t'il ~ ,~:J:T~*T o
The fan will begin to run and the pilot lamp for "RUN" will
light up.
O~~,m-I;[)~.A-{ -:;=Til~ ICOOLJ l~ft-0-cv\.:S ;:_~~lit~~
-c <t-c. ~ 1t \0
CONTROL SWITCH
Check that the COOL/HEAT change-over switch has been
set to "COOL".
eJOL
FAN O~m~~~OO~fl ~*To
OFF • H~T
Turn the knob to "HEAT/COOL", and cooling will start.
CONTROL SWITCH
WARM COLD
THERMOSTAT
• f$.11:. C7) ~ iP k
Stopping
I OFF J ~~ '/ -y ~ ~..g-:b--lt-c <t-c. ~ 1t \o IRUNJ 7 /7"il~WL:t.:c 7
:::z /il~f$.11:. ~*To ( ;:_ Cl)~, ~ 7 /~ Jr~ .A l:: ~ !?l~imm ~*To)
Turn the knob to "OFF", and the pilot lamp for "RUN" will go
off and the air conditioner will stop. (At this time, the
crankcase heater is energized.)
CONTROL SWITCH
- 9-
el!l.r-RJwaJ~O) L-iJo.f-:__ - - - - -!f 7 H~~~0)~1Hil!?i:l±l 7'' !J ;v:a:waJW L- -c t-.:. 2:: v\0 <
Adjustment of air flow In case the conditioner is ducted, adjust the air discharge
grill provided in the room.
• ~ J!1.:a: J::jj rRJ, T jj rRJ, M jj rR1 f;: rR1 ~t f-:__ v\ ~ ~ l'i, ~ l±l 7'' !J ;v
:a: 1 ttf-') }!1. :a: l±l '--' f-:__ v\ jj rRJ f;: rRJ ~t -c <t-.:. 2:: v\0
~J!I.I'i~~ l::r-RJ ~ f;:I!Ji:t±:lT J: 5 f;:T 0 ~, ~m5Z::h=*7J~lb7J~ VJ ~To
[email protected].~ 7)~ ~" \ t-:__ 60, ~ td'il!I.:S:7J~illl::kt~ t-:__ 60 r;: !Qk.AJ±JJ 7)~ 1:: sc.f~ :a:~*- 0 ~ ~ r'i, l!l.
:S::a:~ 0 ""(~JE{~ r-..waJ~T 0 £,~7)~ (b VJ ~To
When suction pressure exceeds the above range due to the high temperature of suction
air or excessive air flow, it is necessary to reduce air flow by adjusting damper.
-10-
s. :t3-=¥-.An
Maintenance
@~c:f:l (J) * ::z !J ~I& I?~~, v\-J 'b ~ :h,v \ft~J!l.~* I? l±lTf;: ~ f;::_, ::c 7 7 -1 ;v7' iJ~l& I? fi~t
Gn-cv\~To ::.n~:ff</i5c0-cto~~TC:, ::c77--fJv7'(J)§iJ~-J~I?, J!l.:liii~~&L-, ~
mflliJJ ii~fftTT Q C: C: 'b f;::_, ~!IJ:H~oo f;::_~iJ~-J ~, ::c 7 ::z /iJ~i!tc~fT Q ~nil~ ib I? ~To
The air filter attached to remove dust and dirt from the air and distribute cool, clean air. If
the air filter is left unclean for a long time, it will be clogged and air flow through it will be
reduced, cooling/heating efficiency impaired, the evaporator surface frosted, and cause
trouble with the air conditioner.
®P&~~f!) ;viJ~~ ~ ~ T C:, ::c 7 7-1 ;v7' iJ~]\.0 -cv\ Q (J)tJ~ ~;t ~To
The air filter can be seen when the grille is opened.
- u-
@I& I) l±l LJ::.x 7 7-1 ;v7' l'i, if\ :::z V ~i'blt\, 1'f1flkiHb.0 ~m--c'1)t0
-c <t~ ~ l,t\0
Dust the air filter and wash it with clean cold or warm water.
._,,*~]
[ '-!.:t:l~
050°Cf,/.J::JJ).:t3m--c'1)tbt~ It\ -c' < t~ ~It \o
Ox 7 7-1 Jv7' f'i:k-c'ib~ G f~lt\'"(' < t~ ~ lt\o ~;t 0 =. ~ iJ~ ib IJ ~To
Ox 7 7 -1 ;v 7' l'ifi:~F~,, @::tH3 :7t f~ ib -c f~lt \ -c' < t~ ~ 1t \o *i!tr =. ~ iJ~ ib IJ ~To
o~ < f~I1Jn(l)o~'"\~ =.6-c'.::'f!efflf~t~0~il'f:tmtw(l)tJiliJ3E~~< L-c< t~~"\0
[Cautions]
ODo not wash the air filter in water that is over 50°C.
ODo not expose the air filter to fire, or it may catch fire.
ODo not expose the air filter to direct sunlight for long time, or it may shrink.
OClean the air filter more frequently when the air is very dirty.
-~~O)j'f1ftffl-
Cleaning the exterior of the air conditioner
-rz:" \t::.
~ -li:'t::.
** G tJ:." \:ffl -c'~ < Ptv \ -c < t~ ~ "\0 -t- n. -c' t 11Jni!~ I&n t~" \ ~ ~ f:t,
G iJ:. 1t \:ffl -c'=lit 1t \ -c < t~ ~ 1t \0
*tJ:. r:p ·~1)t1f!J ~?i
Lightly wipe the exterior of the air conditioner with dry, soft cloth.
If it is very dirty, use a soft cloth soaked in water or neutral detergent.
._,,*~]
[ ' - t..::t:j~
O@:ft€7k~iJ:.~t-crf1ftffl- Lf~lt\-c' < t~ ~ lt\o
050°Cf,/.J::O).:t3m-~f!effl Lf~lt\-c' < t~ ~ lt\o ~~~~-{SO)~h,iJ~ ib IJ ~To
o 7J '/ v /, .--.:::/::/, ~ /7-~, ~ 7J=f-:¥5Jt~ ~'-c'=litlt \t::. IJ, rnJliO)r~~~£B1f!Jt~ ~, ~tJ:.~t
t::. IJ L t~ It\ -c' <t~ ~It \o
[Cautions]
ODo not pour water directly on the air conditioner to clean it.
ODo not wash the air conditioner with water over 50°C, or it may be deformed or
discolored.
ODo not use gasoline, benzine, thinner, polishing, compound, etc, when cleaning the air
conditioner or spray liquid insecticide over it.
-12-
e F v:.o"/(J)~Nff
Cleaning the drain pan
UN#ff:1J¥~J
F v / /" /(J) tl:Hl 1\f;:, * !J ::z ~=L~ iJ~--=>~ 0:::. ~ iJ~ ~ ~ ~ T(J)-c', F v //"/:to J: LJ F v
* v
/ tl:l ~::J f= 1-1~ L -c"' o ::z "'o
~ ::t 3: :a: I&~ ~ ~, Ib-n t;::ffi -c-ta:", -c <t-!. t3
[ Cleaning method ]
Remove dust and dirt from the drain pan and its outlet and then wipe them with a wet
cloth.
- 13-
·{~*i~(J);fQ-=f-}\.tJ.,
Maintenance for condenser
Extract all water from the lowest position of the piping system.
In addition, open the upper and lower cock of condenser and
let water flow out.
L- -c t-c. t3v \0
@h:tl(J)~ :a: f'if' <
Remove the right and left-end cover.
As shown in the figure, brush off each cooling tube from left to
right alternately with a brush.
-14-
•*~F~9~fi :a:w ll: -t .:S ~~
Maintenance before prolonged idle period
D-* S f;i ~- *M~fi :a: ~ -c, ri'Jfffl :a: J: <ij!t:ijk ~ -r <t~ "6 v \ 0
Operate the fan only for half a day to dry out the inside.
-'t (/) ;t ;t f;: ~ -r :to~ ;t -t ~, ~~(/) s f;:7J<tJ~itlffi ~ -r, ijc~ il~~~-t ;s ::. ~ il~ ~ ~ ;t To
- 15 -
6. JEWL~~
Regular inspection points
It is desired to inspect the air conditioner regularly to prevent trouble and maintain it fully to
make it exhibit the best efficiency rather than servicing it after trouble occurred.
The simple regular inspection will be described below.
@~9J O)iF :::r !J ~I& 1J ~~, ~~~ ~ .hv\f,tff'iM~* 1J lliTf;: 66, .:c 7 7 -1 ;v7' iJ~l& 1J fi~t G.h
-cv\~ T o -:..n~* <$5ctii L ~ T.!:: *
:::r !J -r:x. 7 7-1 ;v7' 0) § iJ~-J~ IJ, M:S:iJ~~:PT ~.!:: .!::
'b ~~, ff'i mfitgtJ iJ~r-l i? -c ~~TO) -r:, J: <flfti L -c <t-c: ~ 1t \0
fl!tif'i.:c 7 7 -1 ;v 7' ~~ Lll< -r: ~:!:*~?)tv \1-i.!:: Ltd~, b .!:: Jm IJ .:c 7 :::r / 1~!1:£ 66 -c <t-c: ~It \o
The air filter is attached to remove dust and dirt from the air and discharge clean and cool
air. If the air filter is left unclean, it is clogged, air flow is reduced and cooling/heating
capacity impaired.
Remove the air filter, and wash away dust and dirt from it with water, and return it to its
original position.
e:EIPj'd~0)3t~ C#illl<ff'i*IJO)~)
Replacing the anti-corrosive galvanized piece (Sea water)
f!.1i~JfEllii'dt&
Anti-corrosive Anti-corrosive
galvanized plate galvanized plate
)~·~ ~:,;
Packing
II
Cover
-16 -
eFAN ~~~t0)7'£llJ3
Lubrication to the fan bearing
~
MI¥J 1;: B:l!E L- -c <t~ ~ v\0
For smooth fan rotation, lubricate the fan bearing
regularly.
)iJ!IlD /
Lubricating
port
. 2 7J j] 1;: - tt
cy~ :::z- /fts6'"J~, r:- v ::7 -1 /0) ~ ~ 1;: 'b a:M L- -c <t~ ~ "\ 0 )
• · 17 ;v/~.::. 7 ::7'' !J ~.A 3J ( "S/ ::c.Jv::fil!E (:!*) ~~)
®7 7 / O)Jli <1;: 118" t:• /~ ::7'' !J -.A.:::. v 7" ;viJ~ ~ ;:t ~ -t 0) -c-, ~-=:. iJ:. G B:l!E L- -c <t~ ~ v \0
The 118" pin type grease nipple can be seen near the fan.
Supply the grease from it.
® ::7'- v ~ .A 3'E :l:ii ::a l:t, ::7'- v ~.A t~~ ~ ~ -t ~ r~, n:. G:P L- 1:±:1 0 w.tt 1;: L- -c <t~ ~ " \0
Supply the grease until it comes out of the gap of the bearing a little.
[Caution]
Note that water and dust are not intermixed in the grease while supplying.
-17-
e7 7 /~;v t- O)~fJiml~
Adjusting fan belt tension
-7- Y / ::1'Mt.& ~ l:tf--t ~, 7 7 /~;v t- iJ\ ~ ;t ~To .:. O)~;v t- ~ ~ 0) ct 5 l~t~--c':Jfl3 ;t -c,
~ 5mm t~:btfO)iJ\@~--c'To t L-.:.tL£J,___Cf=:btf~~~~~'i, iml~L--c< tc~v\o
When the front panel of the casing is removed, the fan belts can be seen. V belt tension is
correct if the V belt slack is about 5 mm when pressed lightly with a finger as shown in the
figure.
CtmJ~h"rtJ
~ 0) ct 5 ~~ iml~-T::; t- ~ L- 6b -c, 5(1=1J 0):/J r-PJ~
CITI~~-ITI~~6~,~N!--ffil-~IJ~To
[Adjusting method]
Tighten the adjusting nut, and move the motor
to the direction pointed by the arrow mark.
The belt is this tightened.
-18-
emYJ.*&c(J)i:tlrrff
Additional tightening of the electric system
J±1JimM~P'J$(l))!#ff-=f
Terminals inside the pressure switch
~ <l::.::kmVftil~mtn0$01:t3'E0,~~ L
m~#lmM~~P'J(7)1f.)!ffij-=t- -c <t2:. ~ v'o
Each terminal in the magnetic switch box
In particular, inspect the parts which
are subject to big current.
milffil'tlffi-=t-
Power source terminal
e1t$~N~(J)~0~(J)~~.itlM.ff~~~
Inspection of each bolt loosing, additional tightening and inspection for gas leakage
-19-
·~fi~flj:O)~~
Recording operation conditions
•m•a.~~lkm~. ~~m~~~~fi~#~~&L*~o
-:. nl:t~f-'HI~~~:fi?~lta-:. 0 f;::)~-fi-, W-129 0)~1¥] 0)~~~~ tt IJ *~a
Record operation conditions such as power source voltage, condenser water temperature
and room temperature.
Such records will help to find cause of trouble in the future.
Inspect the following points and record them so that the air conditioner can be operated
effectively for a long time.
Time of Actual
Inspection items Inspection points Judging standards
inspection state
Power source Check with Within ± 10% of
voltage a voltage meter rating voltage
v
Leaving condenser Check with oc
~ Around 30"-'43°C
.....0 water temperature a thermometer
~
C,)
Q.l Difference between
0..
00 entering and leaving Check with Temperature difference
..~. . "C
condenser water a thermometer from 3"'"'4°C
........:>.. .
Clj
temp
t=l Check with oc
Room temperature 15.5"'25"CW.B
a thermometer
Vibration and Check with Abnormal vibration
operation noise eye and ear and operation noise
-20-
·-/~ffff~OOMB~t~~ff~~~-
Inspection of High/Low pressure switch for pressure setting
-~ffff~OOMfi~ rmfffJtiJ · . · -c ff ~
ffH~fJ 1k .:a:- 11: &1J ~~-0~P'l f;:~-'5::. ~
~ }Efl[ OFF ~ff~ .:a:-,¢.\ lH- .:a:- J! f.t_ iJ~ G 7 :r. ~
.fffjtlj +o.1MPa
~ .T-'5o -!7
~fffjtlj +0.03MPa
J#: 1ttff fjtlj • . -~~fii±IP#.:a:-L.&'J
~ -c
ff~ lH- .:a:--J! f.t. iJ~ G
7-:r.~-!7
Time of
Inspection items Inspection points Judging standards
inspection
1=1 Inspect the dual High pressure side · ·Stop . Within allowable
0
......
..., pressure switch for condenser water and check it, tolerance .
0
Cl)
0..
OFF pressure looking at the pressure gauge.
rn High pressure side
1=1
...... setting.
.......
Low pressure side · · · Close the +0.1MPa
~
;::; condenser outlet valve and Low pressure side
1=1
1=1 check it, looking at the pressure +o.03MPa
~ gauge.
-21-
7. {~;EjEc7)£*f'F~
Basic work for repair
- jJ .A{~j~Q$ -
(R22 Cl)]f.f.::~fflT 0 o R404A C7):m1Him-T:~t~~fl:~~ffl L, --c <t2:. ~ v'o)
Handling of Gas-leak detector
(The following is applicable for only R22, in case of R404A, use with electrical gas detector.)
.:r:. 7 ::z /C7)J'%9jt*~iP G J'%9jtiJ~~n 0::. ~ iJ~ iVJ IJ ;t To ::. Cl):m~f'i ::tJ .A ~~fl:f.:: J:: IJ ~n1!im~
WliJ"' --c {~;@ L, ft ft ;h., f'f ft I) ;t 1±-lv
0
O~nf'i rff,X i¥J -z:' iVJ 0 :m~tJ~ iVJ 1J , ;t t;::!J&Jt)( ~ n --c iJ:. G~iS C7)~1ti1~ jijJ::. 0 ;t -z:' f'ibfiJ:.tt iJ~
GfF.f rff, C7) -r n ;0~ £VJ 0 t;:: 66, 1E 0 fF.f rff, ~ ;0:. ft --c rr 0 --c <t-c:. ~ " ,
0
)<~ ~te 5 t;:: &'))<~~~ 5 ~;(1.,;0~ iVJ 0 (7)--z:'J&tlkv' f.:: f'i3t0it~ l, "C <t2:. ~ v'o
Take a sufficient time for checking, because gas sometimes leaks intermittently and it
takes a little time to change the frame color after sucking the leaking refrigerant.
Carefully handle the gas-leak detector not to get burnt, because fire is used in it.
[J&f&:17¥:tJ
Handling method
-22-
(8) ~ ~iJ~ ~ <t~ 0 t~ G~~ L- --c <tC. ~ v' o
When the flame ring is heated red, try to detect gas leakage.
O~~JXJ,t1£:ttm-9Q o
Watch flame
(Flame reaction)
&caution
Store the refrigerant to condenser by pumping down, due to prevent the emission of
refrigerants into the atmosphere during maintenance, overhauling or repair work.
In case of the pumping down is impossible, consult with your dealer for repairs, whether to
use the recovery equipment.
- 23-
- Jlt:@~~ · 1fHt3t~ -
Vacuum drying and refrigerant charge
<
:r:. 7 ::::r / r*l (J) ~~Jt il~ ts. ts. 0 tc ~ ~ ~, .IE ~ ts.v \ ~ ~ , ~ t~ f'± ~ ~ ts. ~,, il~ r~.A L- -c" \ .:s m~ f'± ?X
(J)=- ~ r::a:~ L- -c-=~~1!k · ~~Jt3'Ejj;:a:-1-r0 -c t~ ~ < l,t\0
If no refrigerant remains in the air condenser, it becomes short or air is intermixed into the
refrigeration circuit, evacuate the circuit and recharge the refrigerant.
R404AO)~.g-
-----
f- ----- ----- -:: : ,
ln case of R404A
/ft~;Ky,..;:
~g
Pipe
I II
Refrigerant
cylinder
1 ~k~ I
;cond enselr
1
1
~~ ;f, './ J" '--------c-~........____~ -1)0~
!t:&~
Vacuum pump ~~"
Weighing machine To power source
/ft~;j-;'y,..;:
Refrigerant
cylinder
Joint for
(R-22) refrigerant charge
~m "
To power source
!t~~
~gg;f,y)
Weighing machine
Vacuum pump
-24-
[£,~ f,t. IJ't.~]
Tools to be required
~tl.t, iF/-r<, -@~/7", M~#CV2L 7v7T/' ~, ~~(6.4CuT)
Refrigerant cylinder, Vacuum pump, Stop valve (V 2), Flare nut, Copper tube (6.4CuT).
c~wJJr~J
Operation method
CD~YJt:T ~ ~:; ffl~-¥0) 7 v7-T /' ~:a: t'if L --c <tC. '6v'o
Remove the flare nut from the pipe joint for refrigerant charge.
Connect a pipe to the joint for refrigerant charge, open the stop valve V 1 and let the
refrigerant enter into the unit.
(Up to approx 0.2MPa)
@~~iJ~f,t. ltnr'i V 2:a:rm lt"C, •@~/7":a:~ilii L, ~r*J :a:-~@1;: L --c <t:. '61t'o
~?2: ~ / 20°CJ;i.J:. 0)~-fr l'i, ~ / 7" J:: 1J iJI:YJ: il~ t±:l f,t. <f,t.-:> "C iJ:. G
7" O)~ljii cp, JeJ lmt!fr.l3l iJ~
lll#F~'~9f£13l~*Y6!EiliiL --c <tC. '6v'o
m!mr!ll3l il~ 2oocJ;I. r 0)~-frr:t, 5°c ril~ -o .::- ~ 1=, 3o ?tJJ"ffi: L --c <t:. '6 1t 'o
If nothing wrong is found, open V 2 and operate the vacuum pump.
If ambient temperature is over 20°C during vacuum operation, operate the vacuum pump
for another hour after exhausting no air.
In case, ambient temperature is under 20°C, extend the vacuum operation by 30 minutes
for every drop of 5°C.
@~.A~il~ -0.098MPa f;:f,t_-:> "Cv' 9;:. ~:a:~~ L, M~# V 2:a: M 1..: --c <tC. '6v'o
Confirm that suction pressure gauge reading is - 0.098MPa, and close the stop valve V 2.
-25 -
®M~#V1 (tf-/A:fi~O)bO)) .a:-mHt-c f%tzj;.a:- 0.2MPa ~~~EEL-cfflf}i.A~~.a:-1'J--:::>
-c <t-c. ~ v\ 0
Cautions
~t!t*~.P f~7k7tiJ'>.A G fJ:v' J:: 5 f~t±/i L -c <t-c. ~ v'o ~~fO))Jjt!EJ t~tJ: IJ ~To
Be careful not to get water into the refrigeration circuit, or it may cause trouble.
- 26-
- ~~#0)~!&: -
Adjustment of expansion valve
~5ft# l:i Im I;: :to v \ -c 7E:5timl~ ~ tL -c v\ Q k ?h, J.;. t-2: VJ I;: iml~T .:0 ::. ~ l:ill!i ~t -c <t-2: ~ v\o ~tr
:a:-1~-riml~T Q m..g-1:1, £, TfEfJ~t:a:- ~ -ciE-mtt~~~;: tt .:0 J: 5 U3~ L. -c <t-2: ~ v\0 tt :to, iml~
(J) ~ l:t &:> G iJ:. t: ?h JEa,~ ~if~ L. -c :to v\ -c <t-2: ~ v\0
tt:to, iml~tl t:l:ttci;:@Jif"l'ff%tzl(J)?51E:I:il~~1JO L. ~To !Ife5ft# !31*0)/F~..g-J: VJ, ~71ffi.~(J)J& VJ
11 ~t:l*~ n~/F ~ --c: &:> Q m..g-tJ~ &:> Q k ?JJt:E~ L- -c <t-2: ~ " \ 0
The expansion valve has been adjusted at the factory, so avoid adjusting it unnecessarily.
However, if necessary, adjust it correctly, referring to the pressure gauge. Confirm the
starting point before adjustment.
Counterclockwise rotation of the adjusting screw increases refrigerant flow. Note that trouble
with expansion valve is in most cases due to wrong installation of the feeler tube rather than
expansion valve.
mmooM~O)J&flkv\
Handling of magnetic switch
If the contact of the magnetic switch is burnt excessively, replace it. Do not polish the
contact points with sandpaper or file, or the capacity of the magnetic switch is reduced.
Additionally tighten the screws for magnetic switch to prevent inferior contact or
over-heating.
-27-
:$"$:0)
:jj\i]L • "$: "$:$1iim JJj( IE! ~WJ-O)~fJ~ 1tll; til
"'
........
~7/7'/J~
,~n-r-0
ib~m=:~
OOM
(b)~::z-1 Jv-
- =:
$ (C) J±*&~ffl (a)-~ f::f'J:U ;J. jf~f~"""(~:jj\~ ~~~T0
'-" ~Wo]A:0 ,:_ ~ ~~J: ~
~JIY'.JT0miltcb0
(D)Eaf~ (a)-~ f::f'J:~-1 ,:_ O)miJ, ~'IJ~ JBit~~~T0
5ft0
(E)7Uw.1T~ T1JC.O))Jj{IEJf~J: ~ ti€ ~.ffit~ ~l!l~-c t@J ~T0
,~'IJ~ ON fUt Gftv' GT', rU~~
(a) :A-1 -y"f-0)- ~Tti.,f'i@J 0
(b) ~.ffil_~jJ:Afi,{lt
-28-
.UlO)
:!*i5L • Uc ttc~iim
(F)m%.@Jn
W-
(a) JBiM@JnO)
~ ~lt/TO)~flJi
7.A?'C',~~0
7lb
~~~fn-t:o
it
-t-<·11:::~0
rMl*-0
"' 1t ~- .:tn~nf;::.---::>
LJJDA-J
ifliff{llj{'Pt!J "'
(c) ~*!17k7Uil~rfll v'-c~~t;::.-c:O
~/7'0)J±jJtJ~ffi;lt \
"' ~/7'0)@J4iitJ~~f.t.
~-O)~tJ~ ;b 0 f;::_ ~
tttt-t:o
(d) ~~~?&tim~# A\~0 JE;ij!O):!*J!!H;::OO <
0)00JJr/F~
(B).7k~~ (a) ~SWtJ~¥1Jn-c ;:_ 0) :m-il 1:1:1 r::l 7k 71Jil. f7 ~~.t. ~-c-~sw
2
v'0 l:tf.lfv 'il\ HrU !l'Jl'm~~-90
~ (b)/'!y"""/:7''/F~ fj:rf;j It \ ~~tu'!y"""/::1'
m f;::J:0~7k* l:t~-90
)): nO), ~~;::J:
0 ~ -c1:t1t '1]-t.t.v'
2. 1. 2 (A) iimmmcmm (a)wm/F~ mmcHc-mmcfiil ~ JE;ij!O):!*mi;::M~~
[EEJJDA-J
*l*'af'Pt!J
77/
~
0 J:VIRJtr:fflmlb~
~~"'-0
~:(10)tif;::--:>lt''""(
~~t;::.-c-0
2. 1. 2 Jj.!O)}Jji:~f;::_J:
I? EEJJ 00 M~il~fm
T"'-~m, ~f;::J:
I? 1m ~t.t.v ,::_ e: 1;:::
J:0~tlb0t;::.~
S::JJOOM~t,~~O)
::.e:
-29-
•
$$:0)
$: itl:~!lm JJj( [?,;] WimO)~fi~ JL1 Ui
:I*BL
2 2. 1 2. 1. 3 (A) itl:~""Z:I:tt~ (a)~ ::r-77 .-{Jv?t:a:-.~~ ::r.. 7 7 -1 ;v?t l:tfff:Jm
~J.W~~ ~- O)Imi:rl'l'lil~
~T~t~v \il~ffi~
3 To
{# (b) 7v-T .A'¥P.kl±! .~~0 1nTo
m JJ11iJ, ~-7 t- 0)
)1; {1l:~/F&
(c) ~!Jtof;:.J:: ~ $1
fi
7.1~:1$)-I;:~Jj)¥ l-
T
t~v\
0
(B)~ (a)-/FN Off7-~hO)~i;- 0~/FNI:t~~
7)~
(b) ~llltfaiff 7.~ l:t~~$Ar=l~ To <t~t~t.-, ib
f# . (c)~71Iltfaif*fiJ/FN Tf;:*ii.J~-J < ~ ~ -~:t~J! L-
;t Oi*fii/FNO)~i;- t~v\.:. c)
7)~ l:t!J ~y ]-:'/'\"/''"? OI&N~tl:tfnTo
~ -f;:.J::oEE*Til~ 0$:~0)~1:t~~T
v\ •'lifi.l~!§o~it 0
i.l~ibo
-30-
**(1)
~ • * t.&lf$:1iim
(D)~OOf*
®:
(a) ~ll<:fi/FJE,
ll9 ~ltlf(l)~fm
f.l'JEEilt~~~;:f.li v \
~ &I
3. 1 3. 1. 1 ~~- ~cit, #,
3 7 7 '/' !Bfa#l J!l.:fiiJ:~:iE 71<71M~~v \ *'/1'~~-''5
;tt:~ilii
L. "{" 1t \ -c."ib'5 (b) ~7J<tf(l)/'5h
141-
'5
m 3. 1. 2 (A) j!jf( If$: -c." IJ: tt (a) 7 7 '/0)@]~ ,~~'5 fn-t'5
]): J!l.:fi/FJE 1_,\ ;0~~
T (l)**~llm~
(c) ,Y (/ !-- !/'/ /~-
'5
iJ",. (1)00J3r/FJE
141- (B)@~ (a) /F .5!. ';t tc IJ:~ ,~~'5 f~JE, :10 J: v~~~J:
;t ~<
;0~ (C) 7 7 '/-';v (a) -';v !-- (l)r.1J'5:J.;- ,~~'5 *11--9'5
1-- i::J:'5.A !J -y-:/'
~
1_,\ (D) .:c. 7 7 -{ ;v (a)* ::z !) (1)--J';t I) R.i:~'5 m~-r-'5
'7
4. 1 4. 1. 1 (A) 77'/ (a) o-'?(l)d R.i:~'5 f~';tt;:JJ:~~-9'5
141- ;t '5 iJ ~' /Fit.i 77'/~00 (b) i¥1b';t tciJ:~~t ~~~J:l& I) ~<
t:: kftti. OJ {if- (l)tJ'Hj
iJ",.£b'5 (c) P-'?I&#~tt:•'
.A(l)r,<JJ'5:J.;-
(d)~
-31-
.?teO)
:!*&.
4. 1
• ?tc
4. 1. 3
?tc$!im
(A)~f#'JI¥.!~
)Jj(
(a)~~/F.&
[;§
}~~Q
~~O)~fJ~
f~,
jL1 flt
mtw ~ t;::J:tx
~;t;o;O~, ~·~ 1t~m (b)~.~/F.& ~
'tftl~~iif. OJ (c)~,L~f;:::-lf"
A~
(d)WL-~7'/.A-1
4 -y'f", -ro.>ftl1.A
-{-y'f-~0)~
~~
::t:r. /F .&f;:::J: Q/<;7'
1=1
y~
O)~f~ I)
(h) if~~c1f"'O)
OJ
5. 1 (A)~7Mc1f (a) ~ft/F.&;tt~f'j: '~~Q -6b;tt~f'j:{~
~"'-7l<ZJ~~ (B)7J<~~ ~ JtWff6b;tt~fv~v~
:n-o (b) 7J<t±1.A r::l :; -y 'T /~-~
-y)--O)~ft/FJE
(c)/~-y~/~·CDMl
5
71<
m
(c) Fv/~c1f (a)~ Fv/~c1f ~c1f0)~~~ flftffl, {~;ttd'i{~
~
0)/F.& JE lE
.h (h)~rkJ Fv//~ ~71<1JI=71<1f ~ ' )" JtWff6b;tt~f'j:/~-y~
-32-
8. Trouble and countermeasures
State of Position Cause of Points of
Trouble Countermeasures
trouble of trouble trouble diagnosis
1.1 1.1.1 (A) Not due to (a) Electric Measure electricity <)Repair devices in
Both fan and Green pilot trouble interruption. with a tester. switch board.
compressor lamp does with air (b)Wrong wiring in If another electric <)Replace fuse.
do not not light up. conditioner. power source. device is used from <>Correct wiring.
operate when (c) Power fuse is the same power
operational blown off. source, operateitto
switch is (Fuse in switch at see whether
turned. hand is blown electricity is
off) supplied.
(d)Single phasing.
(B)Electric (a) Fuse is blown off Check continuity Replace fuse and
__..... circuit. and bad contact. with a tester. correct wiring.
en
-~ (C) Operational (a)Trouble or bad Check continuity Repair or replace
~ switch. contact. with a tester. them.
-~ (D)Over- (a) Contact points Check continuity Repair or replace
~
Q)
current are left open due with a tester. them.
.:5 relay. to trouble.
~ (E) Pressure
~
"§ switch.
~ (F) Compressor
.8 thermostat.
~
'"C 1.1.2 (A)Magnetic (a) Bad contact. Check continuity Repair or replace
] Green pilot switch for (b)Magnetic coil with a tester. them.
s
......... lamplight fan motor. failure .
'"C
Q)
up.
@
1.2 1.2.1 (A) Not due to (a)Thermostat Turn thermostat
'-€!
Q)
0. Fan is Green pilot trouble. setting is at dial toward
8 operative, but lamplight "WARM" . "COOL".
-~
bl:l compressor up. (b)Since suction air Warm feeler part of
;§
inoperative.
8
,....;
temperature is
too low to turn
thermostat by
griping it.
on thermostat.
(B)Magnetic (a) Bad contact. Check continuity Replace it.
switch for (b)Magnetic coil with a tester.
compressor failure.
motor.
(C) Compressor (a)Trouble or Check insulation Replace
motor. burning. state with a megger. compressor.
(D)Compressor (a)Trouble or In this case, Replace
burning. compressor is compressor.
humming.
- 33 -
State of Position Cause of Points of
Trouble Countermeasures
trouble of trouble trouble diagnosis
1.2 1.2.1 (E)Thermostat Contact points are Compressor does not Replareit.
Fan is Green pilot not turned on due to. operate when feeler
operative, but lamp light (a) 'Ihmble with tube is warmed.
compressor up. switch. But it operates when
inoperative. (b) Gas leakage thermostat is
from feeler tube. short-circuited.
(F) Electric (a) But contact, Check continuity Correct wiring.
circuit. disconnection or with a tester.
single phasing of In case of single
compressor phasing, motor is
circuit. humming.
2.1 2.1.1 (A) Not due to (a) Condenser water Check piping, Open valve if they
Both fan and Green pilot trouble is not supplied. valves and pump. are closed, take
compressor lamp goes with air (b)Condenser water neressary
are operative off. conditioner. is short. countermeasures if
but stop soon. (c)Condenser water piping is wrong.
High
temperature is Check whether
pressure
high. pump pressure IS
switch has
low or pump
functioned.
rotates reversely.
(d) Insufficient Inspect valve Open them
opening of stop openmg. correctly.
valves in
d refrigeration
§ system.
UJ
.8'
UJ
(B) Water (a)Cooling tubes In this case leaving Clean cooling
~ cooled are stained with water temperature tubes with a
..c
"'d. condenser. dust. is low, but brush.
Q)
- 34-
State of Position Cause of Points of
Trouble Countermeasures
trouble of trouble trouble diagnosis
2.1 2.1.2 (A) Over- (a) Bad adjustment. Measure current Adjust it correctly.
Both fan and Green pilot current with an ammeter.
compressor lamp goes relay.
are operative off.
(B)Compressor (a)Current is Check compressor, Find cause of
but stop (Over-
and fan excessive. fan, compressor trouble and take
soon. current
motor. motor and fan necessary
relay has
motor. countermeasures.
functioned)
Check pressure
switch as well,
because the trouble
may sometimes be
caused by
malfunction of
pressure switch as
stated in 2.1.1
2.1.3 (A)Nodueto (a) Obstacles. Check air filter. Clean air filter.
Green pilot trouble. (b)Opening degree Check stop valves Open stop valves
d lamp goes of stop valves on on refrigeration on refrigeration
~ off. refrigeration system for opening system correctly.
en
<Low system is degree.
$'en
pressure insufficient.
~
,..c switch has (B)Filter for (b) Filter is clogged. When air Replace filter.
..a functioned)
Q)
refrigerant. conditioner is
@
operated with
'-8
Q)
contact points oflow
p.
....,
8 pressure switch are
-~ short-circuited,
bJ)
Jl temperature
8c-;i
difference before
and behind filter
becomes excessive.
(C) Expansion (c)Trouble. Replace it.
valve. (d)Gas leaks from
feeler tube.
- 35 -
State of Position Cause of Points of
Trouble Countermeasures
trouble of trouble trouble diagnosis
3.1 3.1.1 (A) Not due to (a) Cooling load is Check if heat source Take necessary
Both fan and Airflow trouble. excessive. is added, numbers countermeasures.
compressor rate is of occupants
are correct. increase or windows
operative. or doors are left
open.
(b)Air discharge Inspect. Rectify.
directions of
plenum chamber
are wrong, or
position of
ducting is wrong.
(c)Cool air cannot
be discharged
evenly by
~ obstacles.
-~ (B)Expansion (a) Bad adjustment. O ln case gas leaks, O lf expansion
.~s
valve . (b)Gas leaks from evaporator inlet valve is-wrongly
feeler tube. piping is frosted. adjusted, adjust
-~
(c) Feeler tube is O ln case feeler tube it, but do not
~
Q) wrongly held. is wrongly held, adjust it
·o
!£lQ) compressor unnecessarily.
sometimes gives OCorrect
~ out abnormal attachment of
§
~
noise due to liquid feeler tube.
,..c
"d. hammer. O Replace feeler
~ tube if it is out of
order.
'il
Q)
0.. (C) Refrigerant (a) Insufficient Evaporator inlet O Additionally
-~
b.O refrigerant piping is frosted. charge
jJ charge. refrigerant.
c§ (In such a degree (Find leaking
~Xi
that low points and
pressure switch repair them)
has not
functioned)
(]))Condenser (a) Condenser High pressure is Check condenser,
and its water flow rate abnormally high. piping, valves, and
related is insufficient pump.
parts. and water
temperature is
high.
(b)Cooling tubes
are stained.
- 36 -
State of Position Cause of Points of
Trouble Countermeasures
trouble of trouble trouble diagnosis
3.1 3.1.2 (A) Not due to (a)Fanruns Check. Rectify if
~
·~ Both fan Airflow trouble. reversely. necessary.
~ and rate is (b) Blades of air
.s
.~
compressor insufficient. discharge grille
are are very tight.
~ operative. (c)Opening degree
·~
!;:1 of duct damper
Q)
bll is insufficient.
;.§ (B)Air passage. (a)Air passage is Check. Rectify if neressary
§
wrong or foreign and remove
~
,.a objects exist. foreign objects.
•t::f
Q)
- 37 -
State of Position Cause of Points of
Trouble Countermeasures
trouble of trouble trouble diagnosis
4.1 4.1.2 (B)Flexible (a)Flexible tube Check flexible tube. Replace flexible
Cooling is Refrigerant tube failure. tube.
sufficient, but system.
uncomfortable 4.1.3 (A) Magnetic (a) Bad contact of Inspect magnetic Repair, clean or
vibration and Electric switch. each part. switch. replace magnetic
noise take devices. (b) Bad contact switch.
place. points.
(c) Rust, dust or
g
·_p foreign object in
~ steel core
~ connecting part.
'1::$
§ (d) Bad contact or
-~ rattling of
push- button
Cd
~ switches and
8 other switches.
~ 4.1.4 (A) Not due to (a) Bad installation. Inspect installation. Rectify
-~- Others trouble. installation.
8
§ (B) Fan motor (a) Bad installation. Inspect fan motor Rectify fan motor
·_p
base. base. base.
~
e (C)Screws (a)Set screws on
external plates
Check screws. Repair them.
Notes: The trouble and countermeasures stated above only for cooling for heating are included.
- 38 -
Recommended oil
A) In the case of SEMI-HERMETIC 1YPE COMPRESSOR
~
MAKE R22 HFC134a or R404A
CD The control panel may be fitted on the side wall instead of inside.
® In the case of the thermostat fitted on the side wall, keep the temperature setting at 20 deg. C
both in cooling and heating mode.
@ In the case of the by-pass valve fitted on the hot gas line, don't change the valve openness.
-39-
Caution for Refrigerant Gas Handling
(1) Regulation
Refrigerant such as R404A and R-22 should be handled in accordance with
"Regulation of High pressure Gas". Refer to "Regulation of High pressure Gas"
that contains some standards so as to avoid accident.
(3) Storage
The refrigerant is not inflammable gas, but a vessel should be stored in well
ventilated and shade place same as other high-pressure gas.
(4) Ventilation
There is a tendency that the refrigerant gas gathers on the floor because it is
heavier than air. Oxygen deficiency may occur inside a room where is filled
with the refrigerant. A fire may cause a pungent smell and corrosive gas if you
make a fire inside the room where is filled with the refrigerant.
(5) Hygiene
Pay attention not to touch directly to skin, eye and mouth.
FIRST AID
-In case of eye
Wash your face with water more than 15 minutes and avoid eye rubbed.
- In case of skin
When the refrigerant is released to atmosphere, its evaporation causes
temperature drop instantaneously. Therefore if skin touches directly the
refrigerant in liquid phase, skin may be frostbitten . If frostbitten is serious,
consult a specialist promptly.
it~lO)JDlf&(, \_tO);±~
(1) 5:!:11
R-404A, &U:R-22~0))t;,ifi .. ~it:ffA.cL ""C .. ~J±:ffA.i*;~);!O)~ffl~~lt*9 o
t:t-=>-c~ilmwH::~J±:ffA.i*:~5:!~~~m!<t::~L ,0
;:0)):!;11f::fi~l±:ffA.f::J::~~W~R1J.It9 ~~1:: .. ~'~~~~~)EcY)""C~LJ*9 o
(2) ~iiO)JNLJtJkL'
(3) Jtril
)t;.l:ffA.fi .. iiJ~tt'1:fj:~LJ*i!/vt:J<, -~O)~J±:ffA.fii.I~JfTjl(::~f::-::>""Cfi ..
)IJjLO) &L 'it'Fam~~lv'1:(t::~L 'o
*t:: .. i!il±~iif::fi .. 3t~~~at:J<~~a~n -cL '-c .. -;E;.:Jul[ .. 1±:1J J;..tJ:.f::tJ:~c:ffA.t:J<
P.IW9 ~;:ct:J<~LJ*90)'1:, ~;I~<t::~L 'o
(5) i*iltfti~J:.O);I~
• 13 f::A -=>t::c~
·15~ra,J;..tJ:.7J<'1:~DRL .. ;:9-:Jf::LJ*ftt::~~'1:~~t::rti!tlt~;:co
·•c11-t:J<U.cL 'flt:fi .. jWL 'mi97J<~c'1:~DRL -c<t::~L 'o
·•r,~f::9<•imfli&L -c~~~~~t~o
;:(J)J::?~$at~i!tlt~t::cY)f::i*:atDRM~i:J'It~;:ct:J<~,~'1:9 o
• ~fiJJlJI"(J)Mn
;t;,t~Rli*~nB'1:::k~tflf:::/&l:ti9 ~c .. iA~f::J::LJfA~~;gJ.iilf'"F~E;:L*9 o
Rli*t:J<JJlJitJ:cf::Mn.Qc .. ~·~~;:9;:ct:J<~LJ*9 0
;(-]J-:g tt~~*Pj
lit7cOO~~it~U ?t7.=.-.I.~;j"...·;~?.A?"1J-.ANo .3
::J.A-=t:o-;m~rt~u
::J.A-=t?t -1'-Tx·.:~?.A.A-J\-No .3
JX B ~ B :o- I-t--Jv=¥-~it~U
1) ')'.=.·;~?No.3
I?'.J~-=t-t: JviffW~U
..::L.=. v·.:~? .ANo.3
(ESSO/MOBIL/-tt::t-..5Jv)