Wiiboox Reeyee User Manual
Wiiboox Reeyee User Manual
Reeyee
Desktop 3D Scanner
User Manual
Catalog
1
1
2
Device List
Scanner Head 1
Turntable 1
Scanner Stand 1
Scanner Bracket 1
Calibration Board 1
Power Adapter 1
Power Cord 1
USB Cable 1
USB Cable 1
Quick Guide 1
3
Specification Parameter
Specification Parameter
Model EinScan-SE
Single Scan
Accuracy
Accuracy: 0.1mm
Suitable
290—480mm
distance
Maximum
200mm*200mm*200mm 700mm*700mm*700mm
scan volume
Minimum scan
30mm*30mm*30mm 30mm*30mm*30mm
volume
Outdoor
No (affected by strong light)
Operation
Special Scan For transparent, reflective and dark object, please spray powder first
Object before scanning
Printable Data
Yes
Output
4
System Requirement
RAM >8G
CPU i5 or higher
5
2
6
Hardware Installation
Scanner Set-up
Step 1. Place the scanner head onto the bracket.
7
Hardware Installation
3) Plug power cord into outlet and the back of scanner;Plug USB cable into back of
scanner and computer USB port;Plug USB cable into back of scanner, and turntable
Scanner Turn-on/off
Hold on the touch switch for about one second to turn the scanner on;
Double-click on the touch switch and stay for one second each time to turn the scanner off.
8
Software Installation
Software Installation
Double click
installation package,
Follow the
instructions as the
window pops up.
Users can either
choose the default installation path or click the Browse button to select the installation path.
Default installation is suggested.
When the acquired activated file window pop-ups, you can choose multiple device types,
then click “Next”.
Please confirm there is only one device connected. Choose the mode to get activated file:
Online activation and local activation ( click ). After activating a device, you can unplug the
device and plug in other device to continue activating. When finishing click “Next”.
When installation is finished, there will be a shortcut of the software on the desktop.
In the next step, we need to check whether the camera driver installation is successful, right
click “Computer”, choose “Computer Management”-“Device Management”-“Imaging devices” to
check if the camera display normally.
Note:You should One-click on the touch switch to turn the scanner on.
Software Uninstall
Open the start menu, choose Shining3d----Click
“Uninstall or Modify Einscan”, as shown below.
9
3
Auto Scan.
10
Scan Preparation
Mode selection
(1) Auto Scan: This mode is recommended for objects within the size of 200*200*200mm.
(2) Fixed Scan: This mode is recommended for objects over the size of 200*200*200mm, as well
as a comparative stable environment (without obvious vibration) are required.
Special objects
Before scan objects in transparent, semi-transparent or black shall spray on the surface.
11
First Scan
Close Help Mode for Beginner by clicking the top right corner . To
open Help Mode for Beginner, go to Menu -> User Setting ->Help Mode for Beginner
When a warning of license file doesn’t match the scanner pops up when entering scanning mode,
the license file can be acquired by clicking “ Activate”
Operation Procedure
12
Operation Procedure
13
Drop down Menu
1.3.1. TeamViewer
By clicking TeamViewer, you can go to the TeamViewer interface directly without installation.
1.3.2. Feedback
If you have any questions, or suggestions, please share with us by clicking “Feedback”. Leave
your email in “ My E-mail”
14
Drop down Menu
Debug window
Tick the checkbox to open debug window; if you want to close it, unselect it.
Help Mode for Beginner is the default selection, which is to guide the new users make a scan
completely step by step. Close Help Mode for Beginner by clicking the top right corner
. To open Help Mode for Beginner, go to Menu -> User Setting ->Help
Mode for Beginner
To help us improve the quality and user experience of Einscan, we hope to be allowed to
collect usage information to Einscan Team. This information will not identify you and does not
include your project data. By default, this checkbox is selected, and we strongly recommend you
to select it.
System setting (brightness, turntable steps), calibration data will restore to the factory
default settings. Language will be changed into English as default. Factory Default will require
software restart.
15
4
16
Calibration
Click ‘Calibrate’ to enter the interface of calibrate. The first time choose the device type and
click “Next”, it will enter the calibration interface automatically.
Calibrating your scanner is important in order to get accurate scan results. The
following describes the three steps required to successfully calibrate your scanner.
Follow the software operation guide, adjust the distance between the projector and
17
Calibration
calibration board, and the cross from scanner should target at the calibration board n clearly.
Place the calibration support and board in the center of the turntable as shown in Figure A.
Check that the calibration board is located at the center of the turntable with the Figure A
pattern facing the scanner and click “Snap”. Do not interfere or touch the calibration board during
the calibration sequence.
Don’t move the support. Only rotate the calibration board.
After the 1st calibration sequence, the turntable will stop and the display will show what is in
FigureB. Being careful not to move the support, remove the calibration board, rotate it 90°
counterclockwise and place the board back onto the support as shown in Fig. B.
18
Calibration
Upon completion of the 3rd calibration sequence, the software will automatically calculate
and archive the current conditions. This calculation may take several seconds but once complete,
you are ready to start automatic turntable scanning.
When calibration is finished, the software will close the calibration window automatically
and enter the scan mode selection page.
If the calibration fails, please try to re-calibrate following the instructions above. If
calibration fails again, please contact your local support representative.
19
Calibration Precautions
You must finish all the calibration steps according to the instruction when you calibrate at
the first time.
Situations as below need do calibration again:
① When the scanner is used for the first time or after long time without using.
② When there is strong vibration during the transportation.
③ When alignment mistake or failure frequent appear during the scanning.
④ When scanning data is incomplete and quality is much worse during the
scanning.
20
5
21
Help Mode for Beginner
Help Mode for Beginner is the default selection, which is to guide the new users make a scan
completely step by step. Close Help Mode for Beginner by clicking the top right corner
. To open Help Mode for Beginner, go to Menu -> User Setting ->Help
Mode for Beginner
Under the Help Mode for Beginner, following the guidance step by step, you will finish a scan
following: New Project -> Texture/Non-texture ->adjust brightness -> start scanning -> Edit ->
->Continue Scan/Mesh -> Mesh type: Watertight/ Un-watertight -> Post Processing -> Save data
22
Auto Scan
Enter the interface of New Project and Open Project, the default project save location is the
desktop, then it will remember where the user last created a new project. Click “New Project”,
enter the project name, then click ‘Save’ to enter the interface of Non-texture Scan and Texture
Scan selection.
Adjust Brightness
Adjust the distance between the
object and device (suitable working
distance is 290 ~ 480mm), until the cross is
clearly to be seen on the object.
Most users will find that the automatic
settings work just fine but for more complex
objects or lighting conditions, you can
manually adjust scanner settings.
Choose your desired brightness setting
if the object is over or under exposed. Click
“Apply” to confirm, or click ” Cancel ” to not save.
23
Work distance:Adjust the distance between the object and device (suitable working distance is
290 ~ 480mm), until the cross is clearly to be seen on the object.
Adjust Brightness
Click the bottom on the right toolbar to open the adjust brightness window. Click the
button again, and the camera viewport will be hidden. This function is the same as the adjust
brightness when new a project.
Turntable Steps
Before scanning, you can set the scan times
per round under turntable scan. The default setting is 8 times.
HDR
Enable HDR brightness can scan bright and dark objects. The same function
as Adjust brightness “Bright&Dark”.
Start Scan
Click the button to start scanning. After the turntable has rotated one circle,you can
change turntable steps and align mode.
You can edit the current part data after each scan. You can do the below edition if the data has
excess parts.
SHIFT+Left mouse:Select excess parts, the selected section is displayed in red, as shown below.
24
Auto Scan
Undo
You can only undo the last deleted data.
Show/Hide Stripes
Click the button to switch the texture display and hide. Non-texture scan,
there is no such button.
Click to save data and exit the single-piece edition; Click , delete the current
scan data.
After end the single-piece edit, the right toolbar will display, and now can edit the whole scan
data. The specific operation is the same as the single-piece edit.
Manual Align
If automatic alignment failed during scanning, you can use
manual align. Click the button to open Manual Align view port on the
left side of the software. Keep SHIFT down, and click left mouse button
to select at least 3 non-collinear corresponding points in the 3D preview
windows for Manual align, As shown on the right.
25
Auto Scan
not enough overlapping region for registration, click the button to delete current data and then
change the position of the scanner or the object to scan again.
When auto scan mode is scanning, you can click the button to stop the current scan. The
current data will be deleted directly.
Pause
Click the button, scanning will pause; Click again to resume scanning.
Mesh
When the scan is completed, click the botton, proceed to post-processing. You will see
two modes after clicking the button: Watertight and Unwatertight. Watertight usually slower
than unwatertigt. Texture scan mode will take more time compared to Non-Texture scan mode.
Watertight
Closed model can be printed directly. After choose this mode, you should select
the object details.
Select High for objects with fine texture, select Med or Low for objects in smooth
surface or with less detail. The time for data processing is in relation to the detail setting. The
higher the level of details is, the longer time the processing takes. It may keep for a long time in
95%, please be patient.
Unwatertight
Unclosed model. The following picture is the watertight and unwatertight model.
Watertight Unwatertight
26
Auto Scan
Data simplification
After simplification, the polygon numbers, size and surface detail of data will be reduced
accordingly. Check the simplify check box and set the ratio, the default is 100%.
The comparison of detail between before simplification and after simplification (at 30% simplify
proportion).
27
Auto Scan
Fill holes
The default does not check the mark point and fill hole, check the fill hole you need set
perimeter, choose 10-100mm perimeter to fill the hole, less than the perimeter of the hole will
be filled.
After Before
Note:
1. If the edge of the hole is not smooth may cause the effect is not good, not
recommended to fill hole.
2. Hole-filling: choose 10-100mm perimeter to fill the hole;
Smooth
The data to denoise processing, improve data quality, the figure before and after smoothing:
28
Auto Scan
Sharpen
Improve the overall clarity of the data, the figure below before and after sharpening:
Scale
Scaling the volume of scanning data, while the quantity of triangular faces and size of data will
not be changed.
Scaling result as reference: From left to right shows double size, original size and half size
respectively.
29
Auto Scan
Note:
Sketchfab Normal account can only upload data maximum 50M, while Professional
account can share maximum 200M, and set model as private.
Project
You can new or open projects. The default project location is the desktop, then it will
remember where the user last created a new project.
Note:
The projects created by auto scan and fixed scan can be reciprocally imported.
After importing the project, direct access to scan, choose the scan mode based on
whether the imported project is texture.
Back to home
If you want to change the scan modes, click the button to go back to the homepage to
select the scan mode.
30
Auto Scan
Click this button to get the operation manual and notes in more detail under the current
step.
The following picture shows the help information of new project.
Einscan software can be a 3d viewer for ASC, OBJ, STL format file. Drag the 3d model to
Einscan software under scanning mode interface.
31
Auto Scan
Click on the 3d viewer window will close the model view. The scanning window will
be not affected.
32
6
33
Fixed Scan
Choose the Fixed Scan mode, as shown below, enter the scan interface, refer to Auto Scan to
new project ,the select texture and adjust brightness.
34
Fixed Scan
Adjust the distance between the object and device (290 ~ 480mm), adjust brightness, refer to
Auto Scan.
Click to start scanning. When the scan is completed, change the position of object or
scanner for next scan. Make sure the overlap area of currently scan area and the last scanned
data is more than 1/3. Then click scan button, the data will automatically align, until the whole
scanning completed.
Edit, manual align, delete current data, mesh, save data and share refer to Auto Scan.
35
7
36
FAQ
2. Under auto scan mode, if the turntable is not moving, but with a humming sound, how to
solve?
Solution:Disconnect power line and connect again in few seconds.
37