S Series Multifunction DAQ - Up To 16-Bit, Up To 3 MS/s Per Channel, Up To 8 Analog Inputs
S Series Multifunction DAQ - Up To 16-Bit, Up To 3 MS/s Per Channel, Up To 8 Analog Inputs
Recommended NI Software
LabVIEW 7.x or higher LabWindows/CVI 7.x or higher Measurement Studio 7.x or higher Digital Waveform Editor SignalExpress 1.x or higher
Operating Systems
Windows 2000/NT/XP
Analog Inputs 8 4 8 4
Sampling Rate 500 kS/s per channel 500 kS/s per channel 3 MS/s per channel1 3 MS/s per channel1
Input Ranges 4 4 4 4
MS/s with NI-DAQmx; 3 MS/s with additional download. Special conditions apply.
constant, regardless of the number of active channels. S Series aggregate data throughput increases linearly with the number of active channels. Better Dynamic Specifications The analog input path on S Series devices is tuned for both accurate DC and dynamic measurements, compared to traditional multiplexed data acquisition devices that suffer from settling time and distortion error created by switching the input channel. Traditional multiplexed data acquisition devices are ideal for DC measurements, but are not the best solution for dynamic measurements. Many Input Ranges You can configure each analog input channel to use one of several voltage ranges. Make the most of your input resolution by selecting among the four voltage ranges offered by the NI 612x and 613x devices. Large Onboard Memory NI 6123 and NI 6133 devices feature a 16 or 32 MS onboard memory while the NI 6122 and NI 6132 devices feature a 16 MS memory. With deep onboard memory, capture highbandwidth signals over long periods of time, regardless of bus limitations.
Features
These devices fall under the NI S Series product family. The S stands for simultaneous sampling, as this is the most apparent benefit of the dedicated analog-to-digital (A/D) converter per channel architecture. However, the architecture has other less obvious but very important advantages. More Data Throughput The dedicated A/D converter per channel architecture provides a much higher aggregate sampling rate compared to traditional multiplexed data acquisition devices. Traditional multiplexed data acquisition devices share one A/D converter among multiple channels, keeping the aggregate data throughput
Signal Conditioning
With the release of NI-DAQmx 7.4 or later, all S Series devices are compatible with parallel mode SCXI modules.
Model SCXI-1520 SCXI-1125 SCXI-1141/2/3 Description Universal Strain Gage Input Isolation Amplifier 8-Pole Lowpass Filters Channels 8 8 8
SCXI is limited to 100 kS/s for 16-bit accuracy and 333 kS/s for 12-bit accuracy when used in multiplexed mode. However, in parallel mode, the sample rate is limited by the maximum scan rate of the data acquisition device. When SCXI is used in parallel mode with S Series, all channels are simultaneously sampled and the sample rate is limited by the S Series device, from 250 kS/s per channel to 10 MS/s per channel.
Ordering Information
PCI
NI PCI-6123 with 16 MS ........................................................................779409-01 32 MS ........................................................................779408-01 NI PCI-6122 ..................................................................779407-01 NI PCI-6133 with 16 MS ........................................................................779420-01 32 MS ........................................................................779421-01 NI PCI-6132 ..................................................................779422-01
PXI
NI PXI-6123 with 16 MS ........................................................................779181-01 32 MS ........................................................................779180-01 NI PXI-6122 ..................................................................779179-01 NI PXI-6133 with 16 MS ........................................................................778771-01 32 MS ........................................................................779129-01 NI PXI-6132 ..................................................................779127-01
Includes data acquisition driver software.
BUY NOW!
For complete product specifications, pricing, and accessory information, call (800) 813 3693 (U.S. only) or go to ni.com/dataacquisition.
DustMITE
PGIA AI 0 16-Bit ADC AI 0 Control
SCARAB
AI 2
ADC Data
Cal EEPROM
AI Control
I/O Connector
FPGA
STCA
DMA/IRQ
DMA/IRQ
PCI/PXI Bus
DAQSTC
Analog Output Timing/ Control
Bus Interface
AI 0 AI 1 + AI 1 GND AI 2 AI 3 + AI 3 GND AI 4 + AI 4 GND AI 5 - AI 6 + AI 6 GND AI 7 - NC NC NC P0.4 D GND P0.1 P0.6 D GND +5 V OUTPUT D GND D GND PFI 0/AI START TRIG
34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35
AI 0 + AI 0 GND AI 1 AI 2 + AI 2 GND AI 3 NC AI 4 AI 5 + AI 5 GND AI 6 - AI 7 + AI 7 GND NC NC D GND P0.0 P0.5 D GND P0.2 P0.7 P0.3 AI HOLD COMP EXTSTROBE* D GND PFI 2/AI CONV CLK* PFI 3/CTR 1 SOURCE PFI 4/CTR 1 GATE CTR 1 OUT D GND PFI 7/AI SAMP CLK PFI 8/CTR 0 SOURCE D GND D GND
Digital I/O
Channel Control 7
Protection
RTSI Connector
Buffer STC
Figure 2. PXI-6123 and PXI-6122 Block Diagram (channels 4-7 do not apply to NI 6122)
CAL Mux
Address/Data
DustMITE
PGIA AI 0 14-Bit ADC AI 0 Control
PFI 1/AI REF TRIG D GND +5 V OUTPUT D GND PFI 5 PFI 6 D GND PFI 9/CTR 0 GATE CTR 0 OUT FREQ OUT
SCARAB
AI 2
ADC Data
Cal EEPROM
AI Control
FPGA
STCA
I/O Connector
NC = No Connect NC on NI 6122
DMA/IRQ
DMA/IRQ
DAQSTC
Analog Output Timing/ Control
Bus Interface
Digital I/O
Channel Control 7
Protection
RTSI Connector
Buffer STC
Figure 3. PXI-6133 and PXI-6132 Block Diagram (channels 4-7 do not apply to NI 6132)
Digital I/O
Number of channels......................................... Compatibility .................................................... Power-on state ................................................. Input buffer....................................................... Output buffer .................................................... Transfer rate (1 word = 8 bits) ......................... 8 input/output TTL/CMOS Input (high-impedance) 2,044 B 2,044 B 10 Mwords/s
Analog
Input Characteristics
Number of channels NI 6123 ...................................................... NI 6122 ...................................................... NI 6133 ...................................................... NI 6132 ...................................................... ADC Resolution NI 6122, 6123 ............................................ NI 6132, 6133 ............................................ Sampling rate Maximum (NI 6133, 6132)......................... Maximum (NI 6123, NI 6122).................... Minimum.................................................... Input signal ranges (selectable by channel)....... Input coupling................................................... Input FIFO size NI 6123 ...................................................... NI 6122 ...................................................... NI 6133 ...................................................... NI 6132 ......................................................
12.5
8 4 8 4 16 bits, 1 in 65,536 14 bits, 1 in 16,384 3.0 MS/s per channel1 500 kS/s per channel No minimum 10, 5, 2.5, 1.25 V DC 16 or 32 MS 16 MS 16 or 32 MS 16 MS
Timing I/O
Number of channels......................................... Resolution Counter/timers........................................... Frequency scaler........................................ Compatibility .................................................... Base clocks available Counter/timers........................................... Frequency scaler........................................ Max source frequency...................................... 2 up/down counter/timers, 1 frequency scaler 24 bits 4 bits TTL/CMOS 20 MHz, 100 kHz 10 MHz, 100 kHz 20 MHz
Triggers
Analog Trigger
Source............................................................... Level ................................................................. Slope................................................................. Resolution......................................................... Hysteresis......................................................... All analog input channels Full-scale Positive or negative (software selectable) 8 bits, 1 in 256 Programmable
MS/s with NI-DAQmx; 3 MS/s with additional download. Special conditions apply.
Calibration
Calibration interval........................................... 2 years
Digital Trigger
Compatibility .................................................... TTL Response .......................................................... Rising or falling edge
For detailed specifications, please refer to the NI 612x and NI 613x specifications document.
The SH68-68-EP is a shielded 68-conductor cable terminated with two 68-pin female 0.050 series D-type connectors. It features individually shielded analog twisted pairs for reduced cross-talk with high-speed devices. 1 m ....................................................................................................................184749-01 2 m ....................................................................................................................184749-02
The TB-2705 is a screw terminal block for your PXI DAQ devices. It latches to the front of your PXI modules with locking screws and provides strain relief and easy access to your analog, digital, trigger, and counter/timer signals through screw terminals. TB-2705 ............................................................................................................778241-01 Dimensions 8.43 by 10.41 by 2.03 cm (3.32 by 4.1 by 0.8 in.)
The SCB-68 is a shielded I/O connector block for rugged, very-low-noise signal termination for connecting 68-pin DAQ devices. Silk-screened component locations provide an easy addition of simple signal-conditioning circuitry for your analog input channels. It also includes a general-purpose breadboard area as well as an IC temperature sensor for cold-junction compensation in temperature measurements. SCB-68 ..............................................................................................................776844-01 Dimensions 19.5 by 15.2 by 4.5 cm (7.7 by 6.0 by 1.8 in.)
The CB-68 and CB-68LP are low-cost termination accessories with 68 screw terminals for easy connector of field I/O signals to 68-pin DAQ devices. The connector blocks include standoffs for use on a desktop or for mounting in a custom panel. The CB-68LP has a vertical-mounted 68-pin connector. The CB-68LPR has a right-angle mounted connector, and it is used with the CA-1000. CB-68LP ............................................................................................................777145-01 Dimensions 14.35 by 10.74 cm (5.65 by 4.23 in.) CB-68LPR ........................................................................................................777145-02 Dimensions 7.62 by 16.19 cm (3.00 by 6.36 in.)
SERVICE NEEDS
Hardware Services
NI Factory Installation Services
NI Factory Installation Services (FIS) is the fastest and easiest way to use your PXI or PXI/SCXI combination systems right out of the box. Trained NI technicians install the software and hardware and configure the system to your specifications. NI extends the standard warranty by one year on hardware components (controllers, chassis, modules) purchased with FIS. To use FIS, simply configure your system online with ni.com/pxiadvisor.
Professional Services
Our Professional Services Team is comprised of NI applications engineers, NI Consulting Services, and a worldwide National Instruments Alliance Partner program of more than 600 independent consultants and integrators. Services range from start-up assistance to turnkey system integration. Visit ni.com/alliance.
Calibration Services
NI recognizes the need to maintain properly calibrated devices for high-accuracy measurements. We provide manual calibration procedures, services to recalibrate your products, and automated calibration software specifically designed for use by metrology laboratories. Visit ni.com/calibration.
OEM Support
We offer design-in consulting and product integration assistance if you want to use our products for OEM applications. For information about special pricing and services for OEM customers, visit ni.com/oem.
NI provides complete repair services for our products. Express repair and advance replacement services are also available. We offer extended warranties to help you meet project life-cycle requirements. Visit ni.com/services.