128 FB
128 FB
NEW
VISTA-128FBP/V128FBP-24
Designed to integrate seamlessly with CCTV, access
FEATURES:
• Eight hardwired zones standard, expandable • False alarm prevention features to
to 120 addressable points/zones help reduce false alarms
or 128 wireless points/zones • Two on-board notification (bell)
circuits delivering 2.3 amp @ UL approved
• Can control eight separate areas independently for ANSI/SIA
(8 partitions) 12V or 3.4 amp @ 24V CP-01-2000
4208U 4193SN
5192 Eight-Zone Serial Interface 5192 4208SNF
Series Smoke Expansion Module Series Smoke Eight-Zone
Detectors Module V-PLEX Detectors Expansion
Loop Module
5881 With 2 Class A
Wireless Zones
Receiver ECP
6160CR
Red Alpha
Console VistaView-100
CCTV
Switcher
VistaKey V-Plex
Access Control
Module
Notification Appliances
Vista-128FBP 4204 NAC (Bell)
Relay Circuit 4204CF
Module
Symp
Eight Class B Hardware Zones
Serial Printer
4100SM
Printer
Interface
Module
RS232
Notification Appliances
6220S Printer
7720ULF Long
Range Radio 7835CF Cellular
Radio
Applications Main Dialer:
The VISTA-128FBP control is well suited for a variety of • Line seize: Double Pole
applications as an integrated fire and burglary control. A • Ringer equiv.: 0.7B
diverse line of ADEMCO initiating devices supports this • Formats: ADEMCO Low Speed, ADEMCO 4+2 Express,
extremely powerful control. Some of the applications ADEMCO High Speed, ADEMCO Contact ID, Sescoa and
supported are: medical and professional buildings, churches Radionics
or synagogues, office buildings, schools, strip malls, larger • Dual phone line capability (using 5140DLM module)
residences and factory or warehouse environments.
Cabinet dimensions:
• 18”H X 14.5”W X 4.3”D
Installation
The VISTA-128FBP alarm system has been designed to Environmental:
mount both quickly and easily. It meets all applicable • Storage temp: -10°C to 70°C
requirements for UL commercial fire and burglary installations. • Operating temp: 0°C to 50°C
• Humidity: 85% RH
Specifications • EMI: Meets or exceeds the following requirements:
Electrical: – FCC Part 15, Class B Device
• Primary power: 18VAC @ 72VA ADEMCO No. 1451 – FCC Part 68
• Control panel quiescent current draw: 350mA – IEC EMC Directive
• Backup battery:
– 12VDC, 12AH min to 34.4AH max Agency Listings
– Lead acid battery (gel type) Burglary:
• Alarm power: 12VDC, 1.7A max for each notification (bell) • UL609 Grade A Local Mercantile Premises and
circuit output Total 2.3amps @ 12V Mercantile Safe and Vault
• Aux. standby pwr: 12VDC, 1A max • UL611/1610 Grades A, AA, Central Station
• Total power: 2.3A at 12VDC, 3.4A at 24VDC from all • UL365 Grades A, AA Police Connect
sources Fire:
• Standby time: 24 hours with 1A standby load using • UL864/NFPA72 Local, Central Station and Remote
34.4AH battery Station
• Fusing: Battery input, aux. and notification (bell) circuit • Factory Mutual (pending)
outputs are protected using PTC circuit protectors. All • California State Fire Marshal
outputs are power limited. • MEA (pending)
• Optional 24-volt power supply, PS 24 Supplies two 24 • UL985
VFW, 1.7A full wave rectified, unfiltered outputs.
Manual Pull Stations
5140MPS - 1*
5140MPS - 2*
4190SN
4193SN V-Plex Two-Zone
Serial Interface Expander 4293SN 4944SN
Module V-Plex Adapter Tamper Switch*
Addressable
Recessed Mount Flow Switch*
5881 Contact
Wireless Receiver Low Temp Switch*
Bus (Max Two)
4297
Isolation/
5808LST Extender Module
6139R Smoke
32 Character Detectors 5890
Red-Alpha Wireless PIR
Keypad
4209U
Group Zoning
Module
4204CF
Supervised 5816
NAC Door/Window 5808LST
Module Miniature Smoke 4190SN
Transmitter Detectors Supports Up To 16 V-Plex
Conventional 2-Wire Two-Zone
phony Notification Smoke Detectors expander
Appliance
PassPoint
VGM (PTVGM)
Vista
Gateway
Supports Up To 64 Module
Conventional 2-Wire
Smoke Detectors
Vista-128FBP Vista-128FBP
6160CR
Red Alpha 4297
Console VistaView-100 Isolation/
CCTV 5808LST Extender Module
Switcher 6139R Smoke
32 Character Detectors 5890
VistaKey V-Plex Red-Alpha Wireless PIR
Access Control Keypad
Module 4209U
Group Zoning
Module
4204CF
Notification Appliances
Vista-128FBP 4204 NAC (Bell) Supervised 5816
Relay Circuit 4204CF NAC Door/Window 5808LST
Module Module Miniature Smoke 4190SN
Transmitter Detectors Supports Up To 16 V-Plex
Conventional 2-Wire Two-Zone
Symphony Notification Smoke Detectors expander
Eight Class B Hardware Zones Appliance
Serial Printer
VGM (PTVGM)
4100SM Vista
Printer Gateway
Interface Module
Module Supports Up To 64
Conventional 2-Wire
RS232 Smoke Detectors
Notification Appliances
6220S Printer
7720ULF Long
Range Radio 7835CF Cellular
Radio Panel Linking Panel Linking
Module Module
VISTA-128FBP/V128FBP-24
SPECIFICATIONS:
Compatible Devices V-Plex Glassbreak Detectors:
See ADEMCO Group control accessories • 9500SN
compatibility chart for complete list VISTA interactive phone module
Auxiliary Devices • 4286 Voice Module
• 6160CR – Red Alpha Keypad Optional 24V Power Supply
• 6139R – Red Alpha Keypad/Annunciator • PS24 – 24V power supply – 3.4A
• FSA-8 & FSA-24 annunciator modules
Long Range Radio:
• 4204 – Relay Module, four form C contacts
• Long Range Radio 7720ULF-XX, 7835C,
• 4204CF – Two supervised output circuits
7835CF, 7845C
• 5881 Series – RF receiver supporting 5800
wireless detectors Upgraded software:
• 6220S – System printer used with 4100SM • Upgraded Compass Downloader Windows
serial module compatible
Two-wire smoke detectors Wireless Devices:
conventional: • 5804BDV – Bi-directional with voice
• 2100 Series Photoelectric • 5804BD – Bi-directional Key
• 2400 Series Photoelectric • 5804Watch – Wireless Key & sports
• 1100 Series Ionization watch combined
Commercial Four-wire smoke detectors
• 5816 – Door/Window Transmitter
• 5804 – Wireless key
Fire/Burg/CCTV conventional:
• 2112/24 Series Photoelectric
• 5827BD – Bi-directional Keypad
• 5890 – PIR
and Access • 1412 Series Ionization
• 5849 – Glassbreak Detector
Horn/Strobes: • 5819 – Shock Sensor
Control • System Sensor Notification Appliances
Commercial Wireless Devices:
Manual Pull Stations:
Platform • 5140MPS-1
• 5808LST – Wireless Smoke Detector
• 5809 – Wireless Heat Detector
• 5140MPS-2 • 5817CB – Wireless Commercial Transmitter
V-Plex (addressable) Devices: • 5869 – Hold-Up Transmitter
• 4208U Loop Expansion Module • 5881ENHC – Commercial Fire/Burg
-– eight zones Receiver
• 4101SN Single Relay/Zone Module Access Control:
• 4208SNF Class A/B Expander Module • VistaKey V-Plex (addressable)
• 4209U Group Zoning Module Access Control
-– two/four zones • VistaKey-SK Starter Kit
• 4190SN Remote Point Module • VistaKey-EX Expansion Kit
-– two zones • VGM Vista Gateway Module to PassPoint
• 4193SN Two Zone Serial Interface Module Access Control (Northern Computers)
• 4293SN One Zone Serial Interface Module CCTV
• 4297 Isolation/Extender Module – VistaView-100 CCTV Switcher or Module
V-Plex (addressable) Smoke Detectors: Internet Access:
• 5192SD • 4192SD • 4192CP • Graphical user interface with internet
• 5192SDT • 4192SDT • 4192CPM capability
• 4192SDTM • Internet Remote Control-Networking
V-Plex Passive Infrared Detectors: Module
• 998MX • Internet Alarm Communicator (7845i)
• 4275EX-SN Paging:
165 Eileen Way, Syosset, NY 11791 • 4278EX-SN • VA8201 AlphaNumeric Pager
Copyright ©2002 Pittway Corporation V-Plex (addressable) Contacts:
• 4939SN-WH
ADEMCO is an ISO9001 Registered
Company • 4944SN-WH
• 4959SN
ORDERING:
Part No. Description
VISTA-128FBP Commercial Fire and Partitioned Burglary Alarm Platform 12V Model
V128FBP-24 Commercial Fire and Partitioned Burglary Alarm Platform 24V Model
L/V128FBP/D 9/02