Sdetail Div14 PDF
Sdetail Div14 PDF
DWG
COUNTERWEIGHTS
4'-0" 4'-0"
NOTES:
[1200mm] [1200mm]
5" [125 mm] 5" [125 mm]
1. COORDINATE WALL TYPE & FINISH WITH ARCHITECTURAL
.
DRAWINGS.
.
2 3/4" [70mm] 8'-2" MIN.
2 3/4" [70mm]
HOISTWAY 2. SEE STRUCTURAL DRAWINGS FOR ACTUAL SIZE & LOCATION
8'-8" CAR
[2600mm]
8'-8" CAR
3. SEE DETAIL 14 21 00-02 OR 14 21 00-08 FOR ENTRANCE
[2600mm]
12" MIN. 12" MIN. DETAILS.
[300mm] [300mm]
12"
PASSENGER
ROOF SLAB
[300mm] 6'-0" CAR
8'-6"MIN. HOISTWAY [1800mm] 7'-6" MIN.
MACHINE PLATFORM
[2550mm] [2250mm]
1'-6" MIN.
[450mm]
AS REQ'D.
PARTITION WALLS
6'-0" CAR
1'-6"
CMU OR METAL
[1800mm] MACHINE ROOM
LB. CAPACITY
STUDS.
OR PENTHOUSE
FLOOR
4000
PLAN "A" PLAN "B"
6 1/2"
NONE
[162mm]
5" [125mm]
SCALE :
4'-0" [62mm] .
STRUCTURAL SLAB
CONCRETE OR
[1200mm] A
CAR
20 GA. METAL TOP CAB
12" MIN.
DEFLECTOR FLOOR FLOOR
[300mm] ATTACHED AT
METAL SILL SLAB DEPRESSION
1'-6" MIN. TOP ONLY
A FOR METAL SILL 9
HOISTWAY
[55mm]
75
ELEVATOR
6 1/2" [240mm x 62mm]
TRAVEL
[162mm]
9'-10 1/2"
9'-5" CAR
[2825mm]
[3010mm]
HOISTWAY
8'-6" HOISTWAY
LOCATE SIDE
2 1/2" 5" [125mm]
COUNTERWEIGHTS
[62mm] STRUCTURAL SLAB
[2550mm] ON OUTSIDE WALLS,
.
CAR
NOT BETWEEN BOTTOM CAB
AS REQ'D.
ELEVATORS WHEN FLOOR FLOOR
6'-0" CAR HOISTWAY EXTERIOR
POSSIBLE.
[1800mm]
METAL SILL
PIT SLAB DEPRESSION
FOR METAL SILL 9
12"
[55mm]
1/2" x 2 1/2"
2 1/4"
5" [125mm]
PLAN "C"
OVERALL SILL
SD142100-02.DWG
GLIDE GROOVES
3/4" 3/16" 3/4" 1"
SIGHT GUARD METAL SILL
[19mm] [5mm] [19mm] [25mm]
1 1/2"
[25mm]
[38mm]
1" MIN.
20 GA. FASCIA
OVER
FACE OF WALL WALL VARIES STRUT PLATE CONT. HOISTWAY ACCESS 1/4" 3/8" FACE OF
SEE FINISH TRAVEL CONC. BELOW
[6mm] [10mm]
METAL SILL
NON-SLIP
[165mm]
3/16" [5mm] BENT RUBBER BUMPER
[165mm]
6 1/2"
6 1/2"
DOOR STOPS TOP
SILL
PLATE HEADER
[127mm]
5"
INDICATOR
SILL PL. WELDED
FIXTURE TO STRUT ANGLE
BOX 3/16" [5mm] HANGER
[6mm]
BENT PLATE
[6mm]
3"x3"x3/8" 3"x3"x3/8"
1/4"
HOUSING
WALL VARIES
C
1/4"
L
SEE PLANS
LINTEL
1 1/8" CLOSED STRUT ANGLE OPENING CLOSER ANGLE
ENDS METAL 20GA
[76x76x10mm] [76x76x10mm]
[248mm]
[29mm]
9 3/4"
HANGER
CAULK R
CONT. 1 1/4"x1 COVER AS 3/16" [5mm] PL. SILL CLIP
2" DOOR STOP AT
SOUND 1/4"x 3/16" REQUIRED HEATER BOLTED TO 1/ m] TOP & BOTTOM
3 9m
[8
DEADENING SECURED TO STRUT ANGLE METAL FRAME
[86mm]
3 3/8"
BENT PLATE
GROUT SOLID
1/4"
[6mm]
HEADER 4 ADJ. STRAP
[51mm]
DETAILS
OF PENDANT
2"
12 GA 5'-6"
WALL VARIES
1 1/4" 1/4" HEADER
SEE PLANS
[2134mm]
HEAD
[32mm] [6mm]
SCALE : NONE
7'-0"
A A
DOOR
[38mm]
1 1/2"
FACE OF LINTEL COPED
1/4" 1 1/4"
[6mm]
WALL AT EACH END
1/4"
FIN. FLOOR EMERGENCY RUBBER
[6mm] [32mm]
[1829mm]
[2134mm]
KEYWAYS ALL BUMPER CAULK
7'-0"
DOOR
2"x2"x1/8" SILL
6'-0"
LANDINGS DOOR
CLIP [51x51x3mm] NON-SLIP METAL SILL STOP
STRUT
ANGLE
3/8" [10mm]
[6mm]
[22mm]
[6mm]
7/8"±
[29mm]
1/4"
1 1/8"
1/4"
M.B. BASE 3/4" TRIM AT HEAD
JAMB
[19mm] 3/16" [5mm]
BRACKET BENT PLATE
[152mm]
FINISHED 1"
4'-0" LINTEL BELOW
FLOOR
[25mm] SECTION "A-A"
[1219mm]
6"
1/2" [14mm] PASS. ELEV.
M.B.
ELEVATION OF DOORS NOTES:
2 1/2" MIN.
[64mm]
2 3/4" [70mm]
3 1/2" [90mm]
3 1/2" [90mm]
4'-0" 4'-0" 2. SEE STRUCTURAL DRAWINGS FOR ACTUAL SIZE AND LOCATION OF COLUMNS,
[1200mm] [1200mm] BEAMS AND SLABS.
CENTER A CENTER A
OPENING OPENING
3. SEE 14 21 00-04.DWG FOR DETAILS OF HORIZONTAL SLIDING CENTER
DOORS DOORS
OPENING DOORS.
A A
FACE OF
4.
CONCRETE
8'-8" HOISTWAY CONCRETE MACHINE ROOM FLOOR(S) NOT TO BE POURED UNTIL MACHINES
9'-2" HOISTWAY ARE ON MACHINE BEAMS.
[2600mm]
[2750mm]
7'-6" [2250mm]
OUTSIDE WALL NOT ROOF SLAB
8'-6" CAR
BETWEEN ELEVATORS
MIN CLEAR
9'-1/2" CAR [2550mm]
WHEREVER POSSIBLE.
HEIGHT
[2712mm] COUNTERWEIGHT
MACHINE PLATFORM
ELEVATOR, SERVICE
AS REQ'D.
[450mm]
[1200mm]
1'-6"
CENTER
OPENING PARTITION WALL - MACHINE ROOM
AS REQUIRED
DOORS MASONRY OR METAL OR PENTHOUSE
NONE
DETAIL TITLE /
STUD FLOOR
SCALE :
CAR WITH FRONT AND REAR ENTRANCES 5"
NOTE: AVOID REAR ENTRANCE WHERE POSSIBLE.
[125
mm] 2 3/4" [70mm]
TOP CAR 3 1/2" [90mm]
FLOOR FIN. FLOOR
CONCRETE OR CAB
20 GA. METAL FLOOR
DEFLECTOR 75° SILL 1 1/4" [30mm] SLAB DEPRESSION FOR
ATTACHED AT FIN. FLR. 1 1/2" [37mm]
BOLTED METAL SILL 8" x 2 1/2"
.
ELEVATOR
TRAVEL
[450mm]
[125 METAL SILL
1'-6"
mm] 2 3/4" [70mm]
FACE OF BOTTOM
30° .
WALL
30°
FLOOR
3 1/2" [90mm]
FIN. FLOOR
.
20 GA. CAR
6" [150mm] HOISTWAY EXTERIOR DUST COVER CAB
20 GA. FLOOR
DUST COVER BOLTED
TO WALL
1 1/4" [30mm]
1 1/2" [37mm] SLAB DEPRESSION
AS REQ'D. PIT
METAL SILL
TOP DEFLECTOR
TOP FLOOR-DUST BOTTOM FLOOR-
PROJECTING BEAM
COVER AT HEAD TOE GUARD AT SILL SECTION "A-A"
IN HOISTWAY
OVERALL SILL
14 GA. FASCIA
SD142100-04.DWG
ACCESS KEY SWITCH AND BOX TOP &
PLATE CONT.
BOTTOM FLOOR LANDINGS NON-SLIP METAL SILL
TO SILL ABOVE
WALL VARIES STRUT SIGHT GUARDS 1"
METAL SILL
1 1/2"
[25mm]
[38mm]
FACE OF WALL
1" MIN.
OVER
SEE FINISH
SEE PLANS 2 HR. ANGLE 1" 1/4" 3/4" TRAVEL
[105mm]
4 1/4"±
[127mm]
SILL
3"x3"x3/8"
5"
STRUT ANGLE
1/4"
FIXTURE [76x76x10mm]
BOX
METAL 20GA RUBBER BUMPER C
[15mm]
[6mm] L FACE OF
[6mm]
WALL VARIES
1/2"
CLOSED
1/4"
SEE PLANS
HANGER COVER DOOR STOPS OPENING CONC. BELOW
ENDS AS REQUIRED
[250mm]
[29mm] CONT. 1 1/4"x1 1/4"x3/16"
2"
9 3/4"
SOUND
3/16" [5mm] ANCHORS EA. SIDE 3/16" [5mm] PLATE
1/ m]
SECURED TO BENT PLATE
DEADENING HEADER BOLTED TO
BENT PLATE
HEADER [32x32x5mm] 3 9m
LINTEL 2"x2"x12 GA METAL FRAME [8 STRUCT ANGLE
[51x51mm] CLIP
[86mm]
3 3/8"
1/4"
[6mm]
DEADENING
[22mm]
JAMBS AT SILL.
4 1/2"± 4 1/2"±
7/8"±
4'-0"
FACE OF WALL SEE
[114mm] [1219mm] [114mm]
FINISH SCHEDULE CLEAR OPENING
[29mm]
[51mm]
CENTERLINE
1/4"
1 1/8"
2"
DETAILS
OF PENDANT HANGER COVER PLAN
2"
30°
SIGHT GUARD
[152mm]
WALL
12 GA
[1676mm]
[457mm]
METAL 3
FRAME HEADER DUST COVER
HEAD [6mm] [19mm]
18"
BOLTED TO
1 1/4" 1/4" A A
[2134mm]
WALL
[32mm] [6mm]
7'-0"
SCALE : NONE
HANGER
DOOR EMERGENCY
STRUT HOUSING
[1829mm]
[2134mm]
ANGLE KEYWAYS ALL
7'-0"
6'-0"
FIN. FLOOR LANDINGS HEAD SECTION TOP LANDING BOTTOM TOE GUARD
OPENING BELOW
1/4"
CAST
M.B. 4" MIN. [102mm]
[150mm]
FINISHED BEARING FOR LINTEL FIN. JAMB BELOW
JAMB 4'-0"
FLOOR
BRACKET
[1219mm]
6"
WALL VARIES
SEE PLANS
BASE PASS. ELEV.
[38mm]
SCREW 12" ELEVATION OF DOORS
1 1/2"
FACE OF LINTEL COPED
[6mm]
WALL AT EACH END
[300mm] O.C.
1/4"
2 1/2" MIN.
CAULK
[64mm]
[22mm]
[6mm]
7/8"±
[29mm]
1 1/8"
1/4"
E.B. 1. HEAD AND JAMBS OF FINISHED FRAME 3/4" TRIM AT HEAD
14 GA. FASCIA
SHALL BE SECURED TOGETHER WITH
[19mm] 3/16" [5mm]
1" MIN. PLATE
CONTINUOUS WELD. BENT PLATE
1"
LINTEL BELOW
[25mm]
8" 1 1/2" 2. ALL METAL GAGES AND FINISHES OF [25mm]
FRAME AND DOORS AS SPECIFIED.
[203mm] [38mm] SECTION "A-A"
SILL
OVERHEAD MACHINES
VERTICAL DIMENSIONS
HOISTWAYS
300 (1.5) GEARED 18'-0" [5450mm] 7'-0" [2100mm]
NONE
500 (2.5) GEARLESS 25'-3" [7675mm] 6'-3" [1875mm] 10'-0" [3000mm]
SCALE :
700 (3.5) GEARLESS 28'-0" [8500mm] 6'-3" [1875mm] 12'-6" [3800mm]
NOTES:
PASSENGER/SERVICE ELEVATORS
100 (0.5) GEARED 17'-0" [5150mm] 5'-6" [1650mm]
150 (0.8) GEARED 17'-6" [5300mm] 5'-6" [1650mm]
VERTICAL DIMENSIONS
200 (1.0) GEARED 17'-6" [5300mm] 5'-8" [1700mm]
NONE
400 (2.0) GEARLESS 24'-3" [7375mm] 5'-3" [1575mm] 8'-8" [2600mm]
450 (2.3) GEARLESS 24'-3" [7375mm] 6'-3" [1875mm] 8'-8" [2600mm]
SCALE :
500 (2.5) GEARLESS 24'-6" [7450mm] 6'-3" [1875mm] 9'-6" [2850mm]
600 (3.0) GEARLESS 25'-8" [7800mm] 6'-3" [1875mm] 10'-2" [3100mm]
700 (3.5) GEARLESS 26'-10" [8150mm] 6'-3" [1875mm] 11'-2" [3400mm]
NOTES:
[30480mm] OR MORE.
1'-6" MIN. NOTE: SEE STRUCTURAL DWGS. FOR
1'-6" MIN.
VARIATIONS FROM THIS DIMENSION
[450mm]
REQ'D.
"B" PLATFORM "B" PLATFORM
AS
"F" CLEAR HOISTWAY "C" INSIDE CAR "C" INSIDE CAR
"D" MIN. CLEAR HOISTWAY PARTITION WALLS-
"F" CLEAR
"E" INSIDE CAR
HOISTWAY
STUD.
"G" PLATFORM
"G" PLATFORM
AS REQUIRED
4" EDGE OF
[305mm]
12" MIN.
METAL SILL
[100 mm]
FACE OF
CONCRETE
ELEVATOR
2 3/4" [70mm] 5" [125mm]
3 1/2" [90mm]
NONE
TOP FLOOR
SCALE :
3500 LB. CAP. 4000 LB. CAP.
30°
[1580 KG] [1814 KG] SLAB DEPRESSION
ELEVATOR TRAVEL
20 GA. METAL RUNNING CLEAR
A 9'-10" [3000mm] 10'-0" [3050mm] FOR METAL SILL 8'
DEFLECTOR
1 1/4" [30mm] x 2 1/2" MIN.
ATTACHED AT
B 7'-10" [2350mm] 8'-0" [2400mm]
TOP ONLY SILL PROJECTION
5" [2440mm x 62mm]
C 7'-6" [2250mm] 7'-8" [2300mm] 1 1/2" [37mm] [125mm]
D 20'-0" [6000mm] 20'-4" [6200 mm] 3 1/2" [90mm]
HOISTWAY EXTERIOR
METAL SILL
E 4'-10 3/4" [1470mm] 5'-3 3/4" [1595mm] 2 3/4" [70mm] FIN. FLOOR
F 7'-5 3/4" [2245mm] 7'-10 3/4" [2405mm] PLATFORM
TOP DEFLECTOR FOR
G 5'-9" [1725mm] 6'-2" [1850mm] PROJECTING BEAM IN BOTTOM FLOOR
WITH SPEED
NOTES:
RUNNING CLEAR
1. COORDINATE WALL TYPE AND FINISH.
1 1/4" [30mm] SLAB DEPRESSION
SILL PROJECTION
2. COORDINATE ACTUAL SIZE AND LOCATION OF COLUMNS, BEAMS AND SLAB WITH STRUCTURAL.
1 1/2" [37mm]
3. SEE DRAWING NO. 14210-04.DWG FOR ENTRANCE DETAILS.
4. CONCRETE FLOOR(S) NOT TO BE POURED UNTIL MACHINES ARE IN PLACE. PIT FLOOR
5. MACHINE ROOM - APPROXIMATELY 225 SQ. FT. (21 SQ. M) PER MACHINE.
SECTION "A - A"
6. MACHINE BEAMS SHALL BE FLUSH OR BELOW MACHINE.
8'-8" [2642mm] OVER SILL
SD142100-08.DWG
19 GA. FASCIA ACCESS KEY SWITCH AND BOX TOP &
PLATE w/ BOTTOM FLOOR LANDINGS NON-SLIP METAL
STIFFENERS; THRESHOLD SIGHT GUARDS FACE OF
METAL GUIDE GROOVE
1 1/2"
[25mm]
[38mm]
CONT. TO SILL
1" MIN.
2 LAYERS STRUT CONC.
THRESHOLD 1" 1/4" 3/4"
[127mm]
[6mm]
[13mm]
1/4"
1/2"
BENT PLATE HOUSING
[76x76x10mm]
[19mm]
WALL VARIES
ENDS 2"x2"x12 GA
3/4"
SEE PLANS
METAL 19GA OPENING
[5mm]
1 1/8" CAULK
CLIP
HANGER COVER [51x51mm] CLIP NEOPRENE 4" CHANNEL
AS REQUIRED ANGLES WELDED TO
[104mm]
[248mm]
[29mm] ANGLES 3 ASTRAGALS
9 3/4"
3/16" [5mm] JAMBS AT SILL. 1/ 4-Z ANCHORS (5.4#) SUB
BENT PLATE
CONT. 1 1/4"x1 1/4"x3/16" [8 2" FRAME
SECURED TO BENT PLATE 9m R EA. SIDE
LINTEL m]
HEADER [32x32x5mm] METAL FRAME
[86mm]
3 3/8"
SOUND
GROUT SOLID
1/4"
[6mm]
DEADENING CAULK
FINISH WALL 19GA. CONC. SHIELD
FACE OF WALL SEE
LINE 4 1/2"± 4'-0" 4 1/2"± FOR GYP WALLBOARD
FINISH SCHEDULE
[113mm] [1219mm] [113mm] (TYP.)
CENTERLINE HANGER COVER CLEAR OPENING
1/4"
12 GA OF PENDANT
DETAILS
5'-6"
[6mm] METAL BOLT PLAN
[1676mm] BOLTED TO
30°
FASCIA PL.
[152mm]
WALL
WITH STIFFNERS
WALL
[32mm] [5mm]
7'-0"
SCALE : NONE
HANGER
DOOR
HOUSING
STRUT EMERGENCY
[1829mm]
[2134mm]
KEYWAYS ALL HEAD SECTION TOP LANDING
ANGLE
7'-0"
REMOVABLE GUIDES
6'-0"
FIN. FLOOR LANDINGS
TYPICAL NARROW
SILL CLIP
2"x2"x1/8" 2 LAYERS 5/8" ANCHOR LINTEL TO CHANNEL
NON-SLIP SILL
[51x51x3mm] RUBBER
[13mm] GYP. WITH 2" [51mm] CLIP ANGLE
AS APPROVED
BUMPER
EXTRUDED OR BD. EA. SIDE
3/8" [10mm] DOOR FIN. JAMB BELOW
[5mm]
[6mm]
1/4"
M.B. CAST
STOP
JAMB
[152mm]
BRACKET FINISHED
4'-0"
FLOOR
[1219mm]
6"
BASE
OVAL HEAD MACH. PASS. ELEV.
SCREW 12"
[305mm] O.C. ELEVATION OF DOORS
2 1/2" MIN.
[64mm]
1/2" [14mm]
GROUT
SOLID
5 PR. SILL
BRACKETS OR
M.B. NOTES:
3/8" [10mm]
FIVE Z BARS
M.B. 1. HEAD AND JAMBS OF FINISHED FRAME
SHALL BE SECURED TOGETHER WITH
3/8" [10mm] CONTINUOUS WELD. 3/16" [5mm]
E.B. BENT PL. LINTEL
TRIM @ HEAD
1" MIN. [25mm] 14 GA. FASCIA 2. ALL METAL GAGES AND FINISHES OF
1'-0" 1 1/2"
3. SUB FRAME TO BE SUPPLIED AND SET
[305mm] [38mm] BY ELEVATOR CONTRACTOR. PLAN SECTION @ HEAD
SILL
14'-0" [4250mm]
5" MAX.
[125mm]
INSIDE CAR
WELL CASING
MIN. CLEAR
PIPE SLEEVE THRU
2 1/2" [65mm]
WALL TO BE FILLED SEE DETAIL
FIRE STOPPED 8'-8" [2600mm] 6 1/2"
PLATFORM
CMU OR METAL STUD [162mm]
COORDINATE WITH METAL SILL
MACHINE ROOM MIN. 9'-3" [2775mm]
ARCHITECTURAL 1 1/4"
CEILING HT. 8'-0" CLEAR HOISTWAY
"A" [30mm]
[2400mm]
CAR
2 1/4" EDGE OF
[56mm] METAL SILL GROUT
ELEVATOR
SOLID
1 1/4"
FACE OF
5" [125mm] [30mm]
PLAN SECTION
36'-0" [10950mm]
CONCRETE
"A"
ELEVATOR TRAVEL
4'-0" SLAB DEPRESSION
[275mm] [62mm] FOR METAL SILL 9
"D" CLEAR OPENING
5" MAX. 1/2" x 2 1/2"
[1200mm]
2 1/2" [65mm]
[125mm]
NONE
[240mm x 65mm]
7'-11" MIN.
PLAN OF ELEVATOR AT BOTTOM FLOOR
6 1/2"
[2415mm]
HOISTWAY WIDTH DIMS. ON PLAN [162mm]
SCALE :
METAL SILL
AS REQUIRED
PIT DEPTH
1 1/4"
WEATHERPROOF [30mm] SLAB DEPRESSION
COMPOUND 2 1/2" 5" MAX. [125mm]
PLUNGER
[62mm]
HOISTWAY
CYLINDER MEMBRANE W.P. ON
MEMBRANE W.P.
EXISTING BUILDING
ON EXISTING
STEEL CASING MIN.
MEMBRANE W.P. ON BUILDING
THICKNESS, .375" [10mm] NEW CONSTRUCTION FIN. PIT FLOOR MEMBRANE W.P. ON
FILL SPACE BETWEEN NEW CONSTRUCTION
2'-0" MIN.
[610mm]
6" CONCRETE
SECTION "A - A"
[150mm]
DETAIL OF WELL CASING AND PLUNGER ASSEMBLY