Dpi 104 Is

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

GE

Sensing

Features Applications
• Intrinsically safe • Process monitoring and control

• ATEX, IECEx, cETL (Canada) • Test and calibration

• 0.05% full scale (FS) accuracy The DPI 104-IS is an intrinsically safe version of the
microprocessor-controlled DPI 104-digital pressure
• Pressure ranges to 20,000 psi (1400 bar) gauge. The DPI 104-IS matches advanced silicon sensor
technology with several convenient design features,
• Eleven selectable pressure units resulting in an accurate, versatile yet affordable digital
test gauge. Supplied as a stand-alone process indicator
or in a kit with the widely proven Druck hand pumps, the
• Large, easy-to-read display with five-digit resolution
DPI 104-IS provides a reliable and economic solution for
a wide range of pressure sensing applications.
• % pressure indication and additional bar graph for
quick visual reference

• Temperature compensated accuracy from


14°F to 122°F (-10°C to 50°C)

• Pressure switch test

• Minimum/maximum, tare and alarm function

• Stainless steel or Inconel pressure cavity for


aggressive media

DPI 104-IS
Druck Digital
Test Gauge
DPI 104-IS is a Druck product.
Druck has joined other GE
high-technology sensing
businesses under a new name_
GE Sensing.

g
GE
Sensing

DPI 104-IS
Specifications
Accuracy
0.05% FS including non-linearity, hysteresis, repeatability Display Update
and temperature effects from 14°F to 122°F Two times per second
(-10°C to 50°C)
Minimum/Maximum Values
Resolution The minimum and maximum pressure values can
Maximum five digits be displayed on the DPI 104-IS. This function can be
enabled/disabled and reset by the user.
Pressure Ranges
Range Resolution Maximum Working Switch Test
Pressure The DPI 104-IS features a switch test function that will
psi bar type psi mbar psi bar
capture and display the open and closed values from an
0-10** 0-0.7 G* 0.001 0.01 11.2 0.77 external pressure switch. Maximum switch impedance
0-30 0-2 G* or A 0.001 0.1 32 2.2 200 Ω.
0-100 0-7 G* or A 0.01 0.1 111.7 7.7
Alarm Output
0-300 0-20 G* or A 0.01 1 319 22 The alarm output consists of an open drain field effect
0-1000 0-70 G* or A 0.1 1 1117 77 transistor (maximum current 22 mA, maximum voltage
16.9 V).
0-3000 0-200 SG 0.1 10 3190 220

0-5000 0-350 SG 0.1 10 5583 385 Adjustable Mounting Positions


0-10,000 0-700 SG 1 10 11,165 770 For added convenience, the DPI 104-IS housing will
rotate 320° around the pressure fitting and the
0-15,000 0-1000 SG 1 100 15,950 1100
faceplate can be rotated in any orientation for optimum
0-20,000 0-1400 SG 1 100 22,330 1540 visibility.
*All gauge models will respond to negative pressures.
**0.15% FS for 10 psi (700 mbar) range.
Menu Lock
To guard against unauthorized menu access, the DPI
Burst Pressure 104-IS features a menu and tare lock function.
Burst pressure is 2x working pressure (exception,
20,000 psi [1400 bar]; burst pressure 29,000 psi RS232 Interface
[2000 bar]). Serial communications are provided to allow transfer of
data to a PC with the optional serial lead p/n IA4090-2-
Selectable Pressure Units V0 (safe area only). Using this link all menu commands
kPa, MPa, kg/cm2, psi, mbar, bar, inHg, inH2O, mH2O, and display data are available via an ASCII command set
mmH2O and mmHg or the optional SiCalPro software.

Display Network Capability


• Pressure reading: 5 digits with 0.5 in (12.7 mm) Up to 99 DPI 104 IS instruments can be connected
character height together in a daisy chain configured network (safe area
• Full scale indicator: 2.5 digits with 0.25 in (6.35 mm) only).
character height

Pressure Bar Graph


In addition to the numeric pressure indication, the
DPI 104-IS LCD display contains a circular twenty
segment bar graph to provide the user with a quick
visual estimation of pressure from 0 to 100% full scale
output. The bar graph increments represent 5% of the
user-selectable range.
GE
Sensing

DPI 104-IS Weight


13 oz (350 g) approximate

Mechanical Vibration
Specifications To Def Stan 66-31, 8.4 Cat III

Mechanical Shock
EN 60079-0:2006
Battery
The DPI 104-IS is supplied with a 9V alkaline battery, Electrical Environments
type MN1604. Battery life is approximately four • EMC: EN61326:1997 + A1:1998 + A2:2001 + A3:2003
months when used daily for one hour per day. • Electrical Safety: EN61010-1:2001
• Mechanical Safety Pressure Equipment
Pressure Port Directive_Class: Sound Engineering Practice (SEP)
• 1/4 NPT or BSP male for units to 10,000 psi (700 bar)
• 9/16 x 18 UNF male cone connection 15,000 psi Options
(1000 bar) and 20,000 psi (1400 bar) units

Enclosure A) DPI 104-IS external power supply unit with lead


• Case material: ABS/PC anti-static plastic sealed to (safe area only) p/n 191-350
Type 4/IP65 B) PC serial lead for connection to PC;
• Wetted parts: All stainless steel (316) or Inconel p/n IA-4090-2-V0. Requires option A (safe
welded pressure cavity for compatibility with area use only)
aggressive media D) SiCalPro software p/n 1S-SICAL-DPI104IS (includes
IA4090-2-V0 and 191-350)
European Compliance E) Mating plug for eight-pin socket for switch test and
CE marked alarm function (customers wishing to make their
own connections/leads) p/n 1S-04-0027
Intrinsically Safe Certification F) 9/16 x 18 UNF to 3/8 BSP adapter for connection to
• ATEX: II 1G, EEx ia IIC T4 PV 212 p/n 182-190
• IECEx: Zone 0, Ex ia IIC T4
• cETL (Canada): Ex ia IIC T4, Zone 0 *Note-external power can be used in hazardous
• Certification to ATEX, IECEx, CSA standards location with a certified zener barrier (not supplied
by GE Sensing)
SiCalPro Software
This software package allows the user to control the
DPI 104-IS remotely through a virtual instrument panel
on the computer screen. The calibration data can be
Ordering Information
logged, viewed and printed in graphical format or as a
calibration certificate (safe area only). Please state the following (where applicable):
1. Model DPI 104-IS
System Requirements 2. Pressure range, type (G, A or SG) and pressure
Minimum Intel® Pentium® with Windows® 95 or higher connections required
3. Options, if required. Please order as separate items.
4. Please specify Operation Manual language when
General ordering (options: English, Spanish, Portugese,
French, German or Italian.
Operating Temperature
14°F to 122°F (-10°C to 50°C)

Storage Temperature
-4°F to 158°F (-20°C to 70°C)

Dimensions
Diameter: 3.7 in (95 mm) excluding pressure fittings
Depth: 2.2 in (55 mm)
GE
Sensing

DPI 104-IS
Specifications
Pneumatic and Hydraulic Test Kits
The DPI 104-IS is included as a standard component in
these test and calibration kits:
Low pressure pneumatic test kit Pneumatic test kit
Low Pressure Pneumatic Test Kit
Includes DPI 104-IS; ranges to 30 psi (2 bar), PV 210
low pressure pneumatic test pump, hose, adaptors,
seal kit and case

Pneumatic Test Kit


Includes DPI 104-IS; ranges to 300 psi (20 bar), PV 211
pneumatic test pump, hose, adaptors, seal kit and
case

Hydraulic Test Kit


Includes DPI 104-IS; ranges to 15,000 psi (1000 bar),
PV 212 hydraulic test pump, hose, adaptors, seal kit
and case
Hydraulic test kit Pneumatic and hydraulic test kit
Pneumatic and Hydraulic Test Kit
Includes DPI 104-IS; ranges to 10,000 psi (700 bar),
PV 411A combined pneumatic and hydraulic test Test Kit Ordering Information
pump, hydraulic reservoir, hose, adaptors, seal kit and
Pump Model
case
PV210
PV211
PV212
Pressure Range Chart PV411
Code
104S (DPI 104-IS Gauge)
Code Pressure Range Pump options
Code Mode
04 10 psi (700 mbar) PV210
P Pneumatic
07 30 psi (2 bar) PV210
H Hydraulic
10 100 psi (7bar) PV211, PV411
HP Hydraulic/Pneumatic
13 300 psi (20 bar) PV211, PV411
Code Fittings
16 1000 psi (70 bar) PV212, PV411
1 BSP
18 3000 psi (200 bar) PV212, PV411
2 NPT
20 5000 psi (350 bar) PV212, PV411
Code Pressure Range
22 10,000 psi (700 bar) PV212, PV411
X See pressure range chart
23 15,000 psi 1000 bar) PV212
Code Type
G Gauge
A Absolute
SG Sealed Guage

PV211 -104S- P -2-13 G Typical Model Number

g
©2007 GE. All rights reserved.
920-406C_E
All specifications are subject to change for product improvement without notice. GE® is
a registered trademark of General Electric Co. Intel® and Pentium® are registered
trademarks of Intel Corporation. Windows® is a registered trademark of Microsoft
Corporation. Intel and Microsoft are not affiliated with GE, in the U.S. and other www.gesensing.com
countries. Other company or product names mentioned in this document may be
trademarks or registered trademarks of their respective companies, which are not
affiliated with GE.

You might also like