TM803 Digital Fridge/Freezer/ In Out Thermometer Manual

Features:
1. Outer sensor high/low temperature alarm setting
2. Large display for room/outer sensor temperature
3. Maximum/Minimum temperature memory
4. Room/Outer sensor temperature switchable
5. ℃/℉ exchange
6. Foldaway stand
7. Magnetic attachment

Specifications:
Measurement range: ‐10 to +50℃ /14 to +122℉ (Room temperature)
‐50 to +70℃ /‐58 to +158℉ (Outer sensor temperature)
Accuracy: ±1℃/±1.8℉
Display resolution:0.1°
Battery:1.5 volt size AAA/ UM4 or equivalent x 1 piece(included)
Sampling rate:10seconds
Sensor cord length:3 meters

Operation Description:
1. Installation:
Power nn:Pull down the battery cover and pull out the insulation strip in the battery compartment.
Base unit setting:Wipe the desired installation area clean,then remove the protective paper from Velcro magic tape on
unit and press the unit firmly on the installation area.
Outer sensor setting:
a) Out door setting:Use the double side tape to stick the rectangular shape sensor holder on the desires installation
area;
b) Aquarium setting:Press the sensor suction cup firmly onto the glass inside the aquarlum tank with a distance of
about 100mm/4” under the water level.
2. ℃ / ℉ Select:
Press [℃ / ℉] button on the unit back side to select the temperature unit.
3. Roon/Ouer sensor temperature select:
Press [IN / OUT] button to selet room or outer sensor temperature.The IN symbol indicates that the reading is for room
temperature and the OUT symbol indicates that the reading is for outer sensor temperature.
4. Maximun & Minimum temperature memory display:
 Press [MAX/MIN] to display maximum temperature memory (MAX symbol will displayed).
 Press [MAX/MIN] again to display minimum temperature memory(MIN symbol will be displayed).
 Press [MAX/MIN] again to take instant temperature reading.
 Holding [MAX/MIN] one second to reset minimum and maximum temperature memory.
5. High/Low temperature alarm setting (for Outer Sensor only)
 Press & hold [ALARM SET] button then the HIGH/OUT icon will be flashing.
 Use [℃/℉] button to set the desires alarm high limit.
 Press [ALARM SET] button once more and the LOW/OUT icon will be flashing.
 Use [℃/℉] button to set the desired alarm low limit.
 Press [SET] again to finish the setting.
 During the limit setting,holding the [℃/℉] button will advance the value automatically.
 If the temperature value is out of the set limit then the alarm will sound.
 Press any button will stop the alarm sound.