Universal transmitter

4114
– Input for RTD, TC, Ohm, potentiometer, mA and V
– 2-wire supply > 16 V
– FM-approved for installation in Div. 2
– Output for current and voltage
– Universal AC or DC supply

Advanced features
Applications
• Programmable by way of detachable display front (PR 4500
series), process calibration, signal simulation, password
protection, error diagnostics and help text available in several
languages.

Application
• Linearized, electronic temperature measurement with RTD or
TC sensor.
• Conversion of linear resistance variation to a standard analog
current / voltage signal, i.e. from solenoids and butterfly
valves or linear movements with attached potentiometer.
• Power supply and signal isolator for 2-wire transmitters.
• Process control with standard analog output.
• Galvanic separation of analog signals and measurement of
floating signals.
• The 4114 is designed according to strict safety requirements
and is therefore suitable for application in SIL 2 installations.
• Suitable for the use in systems up to Performance Level “d”
according to ISO-13849.

Technical characteristics
• When 4114 is used with the PR 4500 display series, all
operational parameters can be modified to suit any
application. As the 4114 is designed with electronic hardware
switches, it is not necessary to open the device for setting of
DIP-switches.
• A green / red front LED indicates normal operation and
malfunction.
• Continuous check of vital stored data for safety reasons.
• 3-port 2.3 kVAC galvanic isolation.

This page is automatically generated on the basis of information provided on www.prelectronics.com and affiliated websites. It is provided to you as a service and for information
purpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for which we disclaim any and all liability
Environmental Conditions Cold junction compensation
(CJC) via ext. sensor in
Operating temperature................................... -20°C to +60°C 5910............................................................... 20...28°C ≤ ±1°C, -20...20°C /
Storage temperature...................................... -20°C to +85°C 28...70°C ≤ 2°C
Calibration temperature................................. 20...28°C CJC via int. mounted sensor.......................... ±(2.0°C + 0.4°C * Δt)
Relative humidity............................................ < 95% RH (non-cond.) Sensor error detection................................... Yes
Protection degree........................................... IP20 Sensor error current: When
detecting / else............................................... Nom. 2 μA / 0 μA
Mechanical specifications Current input
Dimensions (HxWxD)..................................... 109 x 23.5 x 104 mm Measurement range....................................... 0...23 mA
Weight approx................................................ 155 g Programmable measurement ranges............ 0...20 and 4...20 mA
Weight incl. 4501 / 451x (approx.)................. 170 g / 185 g Input resistance.............................................. Nom. 20 Ω + PTC 50 Ω
Wire size........................................................ 0.13...2.08 mm2 AWG 26...14 Sensor error detection: Loop
stranded wire break 4...20 mA.............................................. Yes
Screw terminal torque.................................... 0.5 Nm
Vibration......................................................... IEC 60068-2-6 Voltage input
2...13.2 Hz...................................................... ±1 mm Measurement range....................................... 0...12 VDC
13.2...100 Hz.................................................. ±0.7 g Programmable measurement ranges............ 0/0.2...1, 0/1...5, 0/2...10 VDC
Input resistance.............................................. Nom. 10 MΩ
Common specifications
Supply
Output specifications
Supply voltage, universal............................... 21.6...253 VAC, 50...60 Hz or Current output
19.2...300 VDC Signal range................................................... 0...23 mA
Fuse............................................................... 400 mA SB / 250 VAC Programmable signal ranges......................... 0...20/4...20/20...0/20...4 mA
Max. required power...................................... ≤ 2.0 W Load (@ current output)................................. ≤ 800 Ω
Max. power dissipation.................................. ≤ 2.0 W Load stability.................................................. ≤ 0.01% of span / 100 Ω
Sensor error indication................................... 0 / 3.5 / 23 mA / none
Isolation voltage NAMUR NE43 Upscale/Downscale............... 23 mA / 3.5 mA
Isolation voltage, test / Output limitation, on 4...20
working........................................................... 2.3 kVAC / 250 VAC and 20...4 mA signals.................................... 3.8...20.5 mA
Output limitation, on 0...20
Response time and 20...0 mA signals.................................... 0...20.5 mA
Temperature input (0...90%, Current limit.................................................... ≤ 28 mA
100...10%)...................................................... ≤ 1 s
mA / V input (0...90%, 100...10%).................. ≤ 400 ms Voltage output
Signal range................................................... 0...10 VDC
Auxiliary supplies
Programmable signal ranges......................... 0/0.2...1; 0/1...5 ; 0/2...10;
2-w. supply (term. 44...43)............................. 25...16 VDC / 0...20 mA 1...0.2/0; 5...1/0; 10...2/0 V
Programming................................................. PR 4500 communication Load (@ voltage output)................................ ≥ 500 kΩ
interfaces
of span........................................................... = of the presently selected
Signal / noise ratio......................................... Min. 60 dB (0...100 kHz) range
Accuracy........................................................ Better than 0.1% of sel. range
EMC immunity influence................................ < ±0.5% of span
Extended EMC immunity: NAMUR
Observed authority requirements
NE21, A criterion, burst.................................. < ±1% of span EMC............................................................... 2014/30/EU & UK SI
2016/1091
Input specifications LVD................................................................ 2014/35/EU & UK SI
2016/1101
RTD input RoHS.............................................................. 2011/65/EU & UK SI
RTD type........................................................ Pt10/20/50/100/200/250; 2012/3032
Pt300/400/500/1000; EAC................................................................ TR-CU 020/2011
Ni50/100/120/1000; EAC LVD........................................................ TR-CU 004/2011
Cu10/20/50/100
Cable resistance per wire.............................. 50 Ω (max.)
Sensor current............................................... Nom. 0.2 mA
Approvals
Effect of sensor cable resistance c UL us, UL 508............................................. E231911
(3-/4-wire)....................................................... < 0.002 Ω / Ω FM.................................................................. 3025177
Sensor error detection................................... Yes DNV Marine.................................................... TAA0000101
Short circuit detection.................................... < 15 Ω EU RO MR Type Approval............................. MRA000000Z
SIL.................................................................. Hardware assessed for use in
Linear resistance input SIL applications
Linear resistance min....max.......................... 0 Ω...10000 Ω

Potentiometer input
Potentiometer min....max............................... 10 Ω...100 kΩ
4114-092822

TC input
Thermocouple type........................................ B, E, J, K, L, N, R, S, T, U,
W3, W5, LR