Ws 2 H 3 Manual
Ws 2 H 3 Manual
Table of Contents
Table 1
General Specifications and Pre-Installation Checklist
Minimum/Maximum Operating Pressures 20 psi (138 kPa) -125 psi (862 kPa)
Minimum/Maximum Operating 40°F (4°C) – 110°F (43°C)
Temperatures
Power Adapter: U.S. International
Supply Voltage 120V AC 230V AC
Supply Frequency 60 Hz 50 Hz
Output Voltage 20V or 24V AC see Table 2 20V or 24V AC
Output Current 800 mA 1000 mA
No user serviceable parts are on the PC board, the motor, or the Power adapter. The means of
disconnection from the main power supply is by unplugging the Power adapter from the wall.
WS2H Valve: 125 gpm (473 lpm, 28.4 m3/h) @ 15 psig (103 kPa) drop
Service flow rate
WS3 Valve: 250 gpm (946 lpm, 56.8 m3/h) @ 15 psig (103 kPa) drop
WS2H Valve: 125 gpm (473 lpm, 28.4 m3/h) @ 25 psig (172 kPa) drop
Backwash flow rate
WS3 Valve: 220 gpm (833 lpm, 50.0 m3/h) @ 25 psig (172 kPa) drop
WS2H Valve: 32.3
CV Service
WS3 Valve: 64.6
WS2H Valve: 25.0
CV Backwash
WS3 Valve: 44.0
Meter: WS2H Valve: Internal Meter WS3 Valve: Optional External
Accuracy +5% Meter
Flow Range 1.5 – 125 gpm (5.7 – 473 lpm) +5%
3.5 – 350 gpm (13.3 – 1325
lpm)
WS2H and WS3 Valves: Variable - Shipped from Factory with 2.2 gpm
Regenerant Refill Rate
(8.33 lpm)
Injectors WS2H & WS3 Valves: See Injector Graphs V3010-2A through 2H
Brine Line Adapters Included 1” Male NPT Elbow & ¾” x 1” Solvent Weld Elbow
WS2H Valve: 2” Female NPT or BSPT or 2.5” Groove Lock
Inlet, Outlet and Drain Line Openings
WS3 Valve: 3” Female NPT or BSPT, No Groove Lock
Distributor Tube Opening: Female NPT Inlet & Outlet Female BSPT Inlet & Outlet
WS2H Valve 2.375” OD (2.0” NPS) 63 mm OD
WS3 Valve 3.5” OD (3” NPS) 90 mm OD
Tank Connection:
WS2H Valve 4”-8UN, 6” Flange, Side Mount (2” Female NPT or BSPT or 2.5” Groove Lock)
WS3 Valve 6” Flange or Side Mount (3” Female NPT or BSPT)
WS2H Valve with Meter: 50 lbs (22.7 kg)
Shipping Weight
WS3 Valve: 57 lbs (25.9 kg) Meter Sold Separately
Nonvolatile EEPROM
PC Board Memory
(electrically erasable programmable read only memory)
Compatible with the following typical Sodium chloride, potassium chloride, potassium permanganate, sodium bisulfite,
concentrations of regenerants/chemicals chlorine and chloramines
WS2H and WS3 Drawings and Service Manual Page 5
Table 2
Software and Power Supply Compatibility
1
It is recommended to maintain one version throughout a system.
2
Replacement V3461 power supplies have screw terminals and are shipped less a cord. Use cord from existing power supply to
connect to the screw terminals.
3
V3461EU-01 and V3461UK-01 will not be available for sale until August 2010.
Page 6 WS2H and WS3 Drawings and Service Manual
Installation:
WS2H CONTROL VALVE TOP VIEW
BRINE/REFILL
INLET
DRAIN
INTERNAL OUTLET
FLOW METER
BRINE/REFILL
INLET DRAIN
OUTLET
WS2H and WS3 Drawings and Service Manual Page 7
Recommended distributor pipe height for top mounted WS3 Control valves is 2 ½” – 2 ¾” above the top of tank for fiberglass tanks.
Please verify distributor pipe and pilot o-ring engagement and make proper allowances for tank expansion.
Do not use Vaseline, oils, other hydrocarbon lubricants or spray silicone anywhere. A silicone lubricant may be used on black
o-rings but is not necessary.
HYDROCARBONS SUCH AS KEROSENE, BENZENE, GASOLINE, ETC., MAY DAMAGE PRODUCTS THAT
CONTAIN O-RINGS OR PLASTIC COMPONENTS. EXPOSURE TO SUCH HYDROCARBONS MAY CAUSE THE
PRODUCTS TO LEAK. DO NOT USE THE PRODUCT(S) CONTAINED IN THIS DOCUMENT ON WATER SUPPLIES
THAT CONTAIN HYDROCARBONS SUCH AS KEROSENE, BENZENE, GASOLINE, ETC.
THIS WATER METER SHOULD NOT BE USED AS THE PRIMARY MONITORING DEVICE FOR CRITICAL OR
HEALTH EFFECT APPLICATIONS
Do not use pipe dope or other sealants on threads. Teflon tape is recommended to be used on all threads.
Use of pipe dope may break down the plastics in the control valve.
When servicing the valve, water may leak from Disconnect from electrical power prior to
the valve. Water from the valve may create a slip servicing the valve.
hazard. Clean up water spills.
The valve will withstand transportation and storage temperatures of -13 ˚F (-25 ˚C) to 131 ˚F (55 ˚C) and for short periods up to 158
˚F (70 ˚C). If valve has been exposed to freezing conditions let valve warm up to room temperature before running water through it.
The valve has been packaged to prevent damage from the effects of normal humidity, vibration and shock.
SITE REQUIREMENTS:
• The plug-in Power adapter is for dry locations only
• The tanks should be on a firm, level surface
• Electrical: Use an uninterrupted outlet installed within 15 feet (4.57 meters) of the water conditioner.
1. Locate the water conditioner so the distance between the drain and the water conditioner is as short as possible.
2. Regenerant tanks that must be refilled should be located where they are easily accessible. It is recommended a safety brine valve
be used.
3. Do not install any water conditioner with less than 10 feet of piping between its outlet and the inlet of a water heater.
4. Do not locate unit where it or its connections (including the drain and overflow lines) will ever be subjected to room temperatures
under 40° F (4° C).
6. INLET/OUTLET PLUMBING: Connect to a supply line downstream of outdoor spigots. Install inlet and
outlet shutoff valves for the control valve; see top view drawings for control valve inlet and outlet locations.
Installation of a three valve bypass is recommended. If using plastic fittings ground the water conditioner
per local electric codes. If an external water meter is used, install the water meter on the outlet side of the
control valve. It is recommended that the meter assembly be installed horizontally or in a downflow vertical
position to reduce turbine bearing wear. The turbine assembly may be orientated in any direction. Remove
the cover and drive bracket and thread the water meter cord through the hole in the back plate. Reinstall the
drive bracket. Weave the cord through the strain relief on the backplate and connect the end to the three prong
connector labeled FLOW on the printed circuit board. Re-install the cover.
7. Drain: Verify that the drain can handle the backwash rate of the water conditioner. Correctly size the drain
line and install an appropriately sized drain line flow control. For WS2H and WS3 valves a drain line flow
control are NOT supplied with a valve. For WS2H valves the drain outlet is 2” Female NPT or BSPT threads
or 2.5” groove lock connection. For WS3 valves the drain port is 3” Female NPT or BSPT, no groove lock
connection. If using copper, solder joints near the drain must be done prior to connecting the drain line flow
control fitting. Leave at least 6” (152.4 mm) between the drain line flow control fitting and solder joints to
prevent heat from damaging the flow control. Avoid elevating the drain line above the control valve where
possible. Discharge the drain line through an air gap to a receptacle in accordance with local plumbing codes.
IMPORTANT: Never insert a drain line directly into a drain, sewer line, or trap. Always allow an air
gap between the drain line and the receptacle to prevent back siphonage.
8. Regeneration: If the control valve is to be used to regenerate the water conditioner with brine (saturated
salt solution) or other regenerants. The WS2H and WS3 control valves regenerant port has a 1” 90° Male NPT
threaded outlet connection that swivels 360°. To ensure acceptable operation of the injectors use 1” pipe to
connect to the brine tank. Smaller drain line flow controls may result in the injector performance not matching
the injector graphs. Use an adequately size drain line flow control to ensure proper brine draw.
See Table 3 for injector order number and size for tank diameter. An overflow drain line from the regenerant
tank that discharges into an acceptable drain is recommended, as a regenerant overflow could damage
furnishings or the building structure. Connect a line to the overflow fitting on the regenerant tank. If an
overflow fitting is not already installed on the regenerant tank, install one. Do not elevate the overflow drain
line. Discharge the overflow drain line through an air gap to a receptacle in accordance with local plumbing
codes.
Table 3
WS2H and WS3 Valve Injector Order Information
Injector Order Number Typical Tank Diameter4
V3010-2A 18”
V3010-2B 21”
V3010-2C 24”
V3010-2D 30”
V3010-2E 36”
V3010-2F 42”
V3010-2G 48”
V3010-2H 63”
All injector graphs are at the end of this manual for total, slow rinse and draw flow rates.
4
Actual injector size used may vary depending on the design and application of the system. Injectors in table are sized for a typical
downflow softener using standard mesh synthetic cation exchange media regenerating with sodium chloride.
WS2H and WS3 Drawings and Service Manual Page 9
9. Power Adapter: If a Power Adapter is already connected to the control valve, plug the Power Adapter into
an uninterrupted outlet. If the Power Adapter cord has not yet been connected to the control valve, remove the
control valve cover and the drive bracket and thread Power Adapter cord through the hole in the back plate.
Reinstall the drive bracket. Weave the cord through the strain relief on the backplate and connect the end
to the four pin connector on the printed circuit board labeled POWER. Reinstall the cover. Plug the Power
Adapter into an uninterrupted outlet.
10. Program the control valve: It is very important to program the control valve for the type of system (e.g.
water softener of filter) and the end use application. Check the program used prior to testing the system.
Installation Summary
Installation Date: ___________________________________________
Installation Location: _______________________________________
Installer(s): _______________________________________________
Phone Number: ____________________________________________
Application Type: (Softener) _______ Other: ____________________
Misc:
Service Flow Rates: min. _________ max. ___________
Tank Size: Diameter _________ Height: ______________
Resin or Media Volume: ___________________________
Resin or Media Type: _____________________________
Capacity: _______________________________________
Salt or Fill Setting per Regeneration: _________________
Brine Tank Size: _________________________________
SERVICE
Raw Water
Inlet
BACKWASH
Raw/Hard Water is bypassed
during regeneration Backwash water
to drain
Raw Water
Inlet
WS2H and WS3 Drawings and Service Manual Page 11
DRAW
Raw/Hard Water is bypassed
Regenerant water
during regeneration
to drain
Raw Water
Inlet Regenerant
solution being
drawn in
Injector feed
water from Raw
Water Inlet
supply
SLOW RINSE
Raw/Hard Water is bypassed
during regeneration Slow Rinse water
to drain
Raw Water
Inlet
Injector feed
water from
raw water inlet
supply
Page 12 WS2H and WS3 Drawings and Service Manual
RINSE
Raw Water
Treated Water Outlet Inlet
BACKWASH
Backwash Water
to Drain Raw Water
Raw/Hard Water is bypassed
Inlet
during regeneration
Page 14 WS2H and WS3 Drawings and Service Manual
DRAW
Backwash Water
to Drain Raw Water
Raw/Hard Water is bypassed
Inlet
during regeneration
Regenerant
solution being
drawn in
Injector feed
water from Raw
Water Inlet
supply
SLOW RINSE
Injector feed
water from Raw
Water Inlet
supply
WS2H and WS3 Drawings and Service Manual Page 15
RINSE
Rinse Water to
Drain Raw Water
Raw/Hard Water is bypassed
Inlet
during regeneration
Treated water
from Refill Tube
1a
5
1
7 9
8
10
6
WS2H and WS3 Drawings and Service Manual Page 17
WS2H Drive Cap Assembly, Downflow Piston, Regenerant Piston, Spacer Stack Assembly,
Drive Back Plate, Main Body and Meter
Drawing No. Order No. Description Quantity
WS2H/3 SCREW BTNSKT HD SS3/8-16X2-1/4
1 V3275 4
(7/32” hex allen wrench required)
2 V3291 WS2H/3 WASHER SS 3/8 4
3 V3225 WS2H/3 BACK PLATE 1
4 V3066 WS2H DRIVE ASY 1
5 V3289 O-RING 344 1
6 V3204-01 WS2H PISTON 1
7 V3238-01*** WS2H/3 BRINE PISTON 1
8 V3065 WS2H STACK ASY 1
V3468 WS2H/3 PLUG 1/4 HEX NPT (included when ordering V3201-03)
Not Shown 2
V3465 WS2H/3 PLUG 1/4 HEX BSPT (included when ordering V3201BSPT-03)
V3201-03 WS2H BODY W/V3468 PLUG
9 1
V3201BSPT-03 WS2H BSPT BODY W/V3465 PLUG
10 V3632* WS1.5/2/3 METER RETAINING CLIP 1
11 V3003-02 WS1.5/2H METER COMMERCIAL ASY 1
12 V3118-03 WS1.5/2 TURBINE ASY 1
13 V3105 O-RING 215 1
14 V3501 WS1.5/2 TURBINE CLIP 1
15 V3279 O-RING 346 1
V3280 O-RING 332 FOR VALVE BODIES WITH NPT THREADS
16 1
V3452 O-RING 230 FOR VALVE BODIES WITH BSPT THREADS
17 V3054** WS2H 4 IN BASE CLAMP ASY 1
18 V3276 WS2H/3 BOLT HEX SS 5/16-18X1-3/4 1
19 V3269 WS2H/3 NUT 5/16-18 SS HEX 1
Not Shown D1300-01 TOP BAFFLE DFSR CLACK 2/63MM 1
* In 2008 a modification was made to Meter Housings to use V3632 WS1.5/2/3 Meter Retaining Clip. Do not use V3632 on old style housings which have holes through the castings to
accept the U-shaped V3223 WS2 Meter Clip.
**V3054 WS2 4 IN BASE CLAMP ASY includes a V3276 WS2 BOLT HEX SS 5/16-18X1-3/4 and V3269 WS2 NUT 5/16-18 SS HEX.
***V3238-01 Brine Piston is used for Backwash Only valves.
THIS WATER METER SHOULD NOT BE USED AS THE PRIMARY MONITORING DEVICE FOR CRITICAL OR HEALTH EFFECT APPLICATIONS.
10
B or indent 12
indicates BSPT 11
13 14
N or no mark
Typical meter retaining clip installation.
Ensure clip is fully engaged in groove indicates NPT 9
and tabs positioned in slot as shown.
3
8
4 5
6 7
1
2
15
16
18
17
19
Install D1300-01 upper diffuser (not shown) when using the 4” Quick Dissconnect (V3064)
Page 18 WS2H and WS3 Drawings and Service Manual
WS3 Drive Cap Assembly, Downflow Piston, Regenerant Piston, Spacer Stack Assembly,
Drive Back Plate and Main Body
Drawing No. Order No. Description Quantity
WS2H/3 SCREW BTNSKT HD SS3/8-16X2
1 V3275 4
(7/32” hex allen wrench required)
2 V3291 WS2H/3 WASHER SS 3/8 4
3 V3225 WS2H/3 BACK PLATE 1
4 V3093 WS3 DRIVE ASY 1
5 V3289 O-RING 344 1
6 V3666-01 WS3 PISTON 1
7 V3238-01** WS2H/3 BRINE PISTON 1
8 V3092 WS3 STACK ASY 1
V3468 WS2H/3 PLUG 1/4 HEX NPT (included when ordering V3667-03)
Not Shown 2
V3465 WS2H/3 PLUG 1/4 HEX BSPT (included when ordering V3667BSPT-03)
V3667-03 WS3 BODY W/V3468 PLUG
9 1
V3667BSPT-03 WS3 BSPT BODY W/V3465 PLUG
10 V3763 O-RING 361 1
11 V3762 O-RING 341 FOR VALVE BODIES WITH NPT OR BSPT THREADS 1
12 V3091* WS3 BASE CLAMP ASY 1
13 V3276 WS2H/3 BOLT HEX SS 5/16-18X1-3/4 1
14 V3269 WS2H/3 NUT 5/16-18 SS HEX 1
Not Shown V3672 TOP BAFFLE DFSR CLACK 3/90MM 1
*V3091 WS3 BASE CLAMP ASY includes a V3276 WS2H/3 BOLT HEX SS 5/16-18X1-3/4 and V3269 WS2H/3 NUT 5/16-18 SS HEX.
**V3238-01 Brine Piston is used for Backwash Only valves.
B Indicates BSPT
9 N Indicates NPT
3
8
4 5
6 7
1
2
10
11 12
14 13
Install V3672 upper diffuser (not shown) when using the 6” Flange Base (V3090)
WS2H and WS3 Drawings and Service Manual Page 19
V3095 WS3 Meter NPT MxF Assembly and V3095BSPT-15 WS3 Meter BSPT MxF Assembly
V3095-15 WS3 Meter ASY NPT MxF 15FT and V3095BSPT-15 WS3 Meter ASY BSPT MxF 15FT
6
1
2
Installation
Installation of the V3075 WS3 Meter NPT Assembly can be accomplished with 3” NPT pipe. For V3075BSPT WS3 Meter BSPT Assembly use 3”
BSPT pipe. It is recommended that the meter assembly be installed horizontally or in a downflow vertical position to reduce turbine bearing wear.
WHEN INSTALLING THE METER, MAKE SURE THE ARROW ON THE METER BODY IS GOING THE SAME DIRECTION AS
THE WATER FLOW. THE METER CAN BE INSTALLED IN HORIZONTAL OR “UPFLOW” VERTICAL APPLICATIONS.
THIS WATER METER SHOULD NOT BE USED AS THE PRIMARY MONITORING DEVICE FOR CRITICAL OR HEALTH EFFECT
APPLICATIONS.
OPERATING PRESSURES: 20 PSI MINIMUM / 125 PSI MAXIMUM
OPERATING TEMPERATURES: 40°F MINIMUM / 110°F MAXIMUM
The 22 gauge wire crimp terminals are Molex Series 41572 or 40445. The housing connector is Molex Series 2695 White Housing, P/N 22-01-3037.
The housing connector diagram shows the proper installation of the RED,
WHITE and BLACK wires for CLACK CORPORATION CONTROL VALVES. RED AND WHITE LEADS
NOT INSERTED IN HOUSING
When connecting to other manufacturers control valves please contact your
original equipment manufacturer for proper wiring instructions.
Wiring:
• The meter must be supplied with a DC voltage between 4 and 24 volts
• The RED wire is positive WHITE
RED
• The BLACK wire is negative BLACK
• The WHITE wire is the meter output
Calibration:
BLACK
• For WS2H valves select 8 pulses if valve software records in gallons and 2.1 if valve software
records in liters.
• The calibration factor for the WS3 Meter Assembly is 8 pulses per gallon when used on V3221 WIRE
HARNESS CLACK
applications other than WS2H valves.
CORPORATION
• The meter flow range is 3.5-350 gpm + 5% (output signal 0.46 Hz to 46.6 Hz). NOTE: Not all flow VALVES ONLY
monitors will register accurately at either the low or high flow range of this meter. Contact your
flow monitor manufacturer for limitations.
• Pressure drop at 350 gpm is 7.3 PSI
Page 20 WS2H and WS3 Drawings and Service Manual
Backwash Only
*V3236-04 WS2H INJECTOR TUBE ASY A
thru H contains a V3285 O-RING 213 and a
V3286 O-RING 216.
15
14
**V3670-01 WS3 INJECTOR TUBE
DOWNFLOW ASY contains a V3285
V3499 Cap Proper RFC orientation 13 O-RING 213, V3286 O-RING 216 and a
installed from directs refill water flow 12 V3163 O-RING 019.
factory. towards the washer face
with radius and text. WATER 11 ***Any V3162-XXX flow control may be
FLOW used. V3237-01 WS2H SOFTFILL TUBE
10 8 ASY contains a V3155 O-RING 112, V3287
7 O-RING 110 and a V3288 O-RING 206.
9
***V3236-01. Could be used
“as is” with A-C injectors. ****V3010-2A through V3010-2G injectors
Diffuser is snipped off if using 5 contain a V3283 O-RING 117 and a V3284
D through G injectors. Order O-RING 114. V3010-2H injectors use a
V3236-04 if using H injector.
3
V3283 O-RING 117 and D1263 O-RING
116.
V3064 WS2H/2QC 4 INCH BASE ASY (For use on WS2H or WS2QC only)
V3055 WS2H/2QC 6 INCH FLANGE BASE ASY or V3090 WS3 6 INCH FLANGE BASE ASY
Drawing Quantity
1 Order No. Description
No. V3055 V3090
1 V3444 WS2H SCREW HEXCAP 5/16-18X2 SS 12 12
2
2 V3293 WS2H WASHER SS 5/16 FLAT 24 24
6
3 V3445 WS2H WASHER SPLIT LOCK 5/16 SS 12 12
3 4 V3447 WS2H NUT HEX 5/16-8 FULL SS 12 12
4 5 COR60FL O RING 6 FLANGE ADAPTER 1 1
5 V3261-01 WS2H FLANGE BASE 1
6
V3671-01 WS3 FLANGE BASE 1
When using a side mount base with 2H or 2QC BSPT valves replace
distributor pilot o-ring V3452 O-RING 230 with V3280 O-RING
332. See exploded view of 2H or 2QC valve for specific location of
2 distributor pilot o-ring.
Page 22 WS2H and WS3 Drawings and Service Manual
DRAWING ORDER
DESCRIPTION QTY
NUMBER NUMBER
1 V3983 WS2 DLFC ADAPTER 1
2 H4615 CLIP RETAINING 474/WS1 1
V3162-007 WS1 DLFC 0.7 gpm for 3/4
V3162-010 WS1 DLFC 1.0 gpm for 3/4
V3162-013 WS1 DLFC 1.3 gpm for 3/4
V3162-017 WS1 DLFC 1.7 gpm for 3/4
ONE
V3162-022 WS1 DLFC 2.2 gpm for 3/4 DLFC
V3162-027 WS1 DLFC 2.7 gpm for 3/4 MUST BE
3 V3162-032 WS1 DLFC 3.2 gpm for 3/4 USED IF
V3162-042 WS1 DLFC 4.2 gpm for 3/4 ¾”
V3162-053 WS1 DLFC 5.3 gpm for 3/4 FITTING
IS USED.
V3162-065 WS1 DLFC 6.5 gpm for 3/4
V3162-075 WS1 DLFC 7.5 gpm for 3/4
V3162-090 WS1 DLFC 9.0 gpm for 3/4
V3162-100 WS1 DLFC 10 gpm for 3/4
4 V3159-01 WS1 DLFC RETAINER ASY 1
5 V3163 O-RING 019 1
WS1 DRN ELBOW 3/4 MALE
6 V3158-03 1
NO HOLE
This assembly is shipped without drain line flow control (DLFC) – install DLFC
before using. Use a minimum drain line size of ¾”.
Apply
Teflon Tape
6
Water flow 4
$SSO\
7HÀRQ7DSH
:DWHUÀRZ 7
6
3URSHU'/)&RULHQWDWLRQ
GLUHFWVZDWHUÀRZWRZDUG
4
WKHZDVKHUIDFHZLWK
URXQGHGHGJH
/XEULFDWHRULQJVZLWK 5
VLOLFRQH
2UGHU'/)&VHSDUDWHO\
2
3 8
$SSO\ 9
7HÀRQ
7DSH
Page 24 WS2H and WS3 Drawings and Service Manual
V3079 WS DLFC ASY 125 MNPT/15 FNPT, V3079BSPT WS DLFC ASY 125 MNPT/15 FBSPT,
V3080 WS DLFC ASY 15 MNPT/15 FNPT and V3080BSPT WS DLFC ASY 15 MNPT/15 FBSPT
Drawing Quantity
Order No. Description
No. V3079 V3079BSPT V3080 V3080BSPT
1 V3081 WS15 RETAINER DLFC ASY 1 1 1 1
V3645 WS15 DLFC FLANGE OUTLET FNPT 1 1
2
V3645BSPT WS15 DLFC FLANGE OUTLET FBSPT 1 1
3 V3646 WS15 DLFC FLANGE INLET MNPT 1 1
4 V3388 WS125 DLFC FLANGE INLET MNPT 1 1
5 V3652 BOLT HEXHD S/S HCS 5/16-18x3/4 4 4 4 4
6 V3441 O-RING 226 1 1 1 1
V3162-007 WS1 DLFC 0.7 gpm for 3/4
V3162-010 WS1 DLFC 1.0 gpm for 3/4
V3162-013 WS1 DLFC 1.3 gpm for 3/4
V3162-017 WS1 DLFC 1.7 gpm for 3/4
V3162-022 WS1 DLFC 2.2 gpm for 3/4
V3162-027 WS1 DLFC 2.7 gpm for 3/4
V3162-032 WS1 DLFC 3.2 gpm for 3/4
V3162-042 WS1 DLFC 4.2 gpm for 3/4
V3162-053 WS1 DLFC 5.3 gpm for 3/4
V3162-065 WS1 DLFC 6.5 gpm for 3/4 Install at least one V3190-XXX in center hole.
Not Shown V3162-075 WS1 DLFC 7.5 gpm for 3/4 Knock out plugs allow installation of up to 6 more
V3162-090 WS1 DLFC 9.0 gpm for 3/4 of V3162-XXX.
V3162-100 WS1 DLFC 10.0 gpm for 3/4
V3190-090 WS1 DLFC 09.0 gpm for 1
V3190-100 WS1 DLFC 10.0 gpm for 1
V3190-110 WS1 DLFC 11.0 gpm for 1
V3190-130 WS1 DLFC 13.0 gpm for 1
V3190-150 WS1 DLFC 15.0 gpm for 1
V3190-170 WS1 DLFC 17.0 gpm for 1
V3190-200 WS1 DLFC 20.0 gpm for 1
V3190-250 WS1 DLFC 25.0 gpm for 1
Assemblies are shipped without drain line flow control (DLFC). Assembly instructions:
1. Determine the desired flow rate. Select one V3190-XXX for the center hole and a combination of V3162-XXX to arrive at the desired flow rate.
At least one V3190-XXX must be used and up to six of the V3162-XXX may be used.
2. Using a drill or punch remove the desired knockout(s) in V3081.
3. Smooth holes.
4. Install appropriate size(s) of drain line flow control washers. Play close attention to proper DLFC orientation.
5. Fit V3441 o-ring onto V3081 Retainer DLFC Asy and assemble. Properly orientate the V3081 in direction of flow.
6. Inlet threads for 1.25” female are NPT. Inlet threads for 1.5” male are NPT. Outlet threads for 1.5” are either female NPT or BSPT. 1.5” female outlet
is stamped with N or B to indicate NPT or BSPT.
2
B indictates BSPT
N indicates NPT
6
Washer
h Flo
w
of
Radius cti
on
re
Di 1
4
3 DLFC not supplied.
At least one V3190-XXX
must be installed in
center hole.
V3051 WS2 DLFC ASY NPT and V3051BSPT WS2 DLFC ASY BSPT
Drawing No. Order No. Description Quantity
1 V3052 WS2 DLFC Retainer ASY 1
V3245 WS2 DLFC FLANGE INLET NPT
2 1
V3245BSPT WS2 DLFC FLANGE INLET BSPT
V3246 WS2 DLFC FLANGE OUTLET NPT
3 1
V3246BSPT WS2 DLFC FLANGE OUTLET BSPT
4 V3273 BOLT HEX HD S/S HCS 3/8-16X3/4 4
5 V3278 O-ring 338 1
V3162-007 WS1 DLFC 0.7 gpm for 3/4
V3162-010 WS1 DLFC 1.0 gpm for 3/4
V3162-013 WS1 DLFC 1.3 gpm for 3/4
V3162-017 WS1 DLFC 1.7 gpm for 3/4
V3162-022 WS1 DLFC 2.2 gpm for 3/4
V3162-027 WS1 DLFC 2.7 gpm for ¾ Install One or
V3162-032 WS1 DLFC 3.2 f gpm or 3/4 More DLFC’s.
V3162-042 WS1 DLFC 4.2 gpm for 3/4 Up to 5 of
V3162-053 WS1 DLFC 5.3 gpm for 3/4 the V3162-
V3162-065 WS1 DLFC 6.5 gpm for 3/4 XXX may be
installed in the
Not Shown V3162-075 WS1 DLFC 7.5 gpm for 3/4
small holes.
V3162-090 WS1 DLFC 9.0 gpm for 3/4
V3162-100 WS1 DLFC 10.0 gpm for 3/4 Up to 4 of
V3190-090 WS1 DLFC 9.0 gpm for 1 the V3190-
XXX may be
V3190-100 WS1 DLFC 10.0 gpm for 1 installed in the
V3190-110 WS1 DLFC 11.0 gpm for 1 large holes.
V3190-130 WS1 DLFC 13.0 gpm for 1
V3190-150 WS1 DLFC 15.0 gpm for 1
V3190-170 WS1 DLFC 17.0 gpm for 1
V3190-200 WS1 DLFC 20.0 gpm for 1
V3190-250 WS1 DLFC 25.0 gpm for 1
Assemblies are shipped without drain line flow control (DLFC). Assembly instructions:
1. Determine the desired flowrate. Select a combination of V3162-XXX’s and V3190-XXX’s to arrive at the desired flow rate. Up to five of the
smaller V3162-XXX’s may be used. Up to four of the larger V3190-XXX’s may be used.
2. Using a drill or punch remove the desired knockout(s) in V3052.
3. Smooth hole(s).
4. Install appropriate size(s) of drain line flow control washers. Pay close attention to proper DLFC orientation.
5. Assemble. Properly orientate the V3052 in the direction of flow. 4
6. Inlet and outlet threads are 2”. Couplings for iron pipe may also be used.
3
e
B indictates BSPT w 4 5
N indicates NPT 1
2 1
Washer
Radius
Direction
Of Flow
Direction
Of Flow
Page 26 WS2H and WS3 Drawings and Service Manual
V3764 WS3 DLFC NPT ASY or V3764BSPT WS3 DLFC BSPT ASY
Drawing
Order No. Description Quantity
No.
V3190-090 WS1 DLFC 9.0 gpm for 1 Install One or More DLFC washers.
V3190-100 WS1 DLFC 10.0 gpm for 1 DLFC washers must be purchased separately.
V3190-110 WS1 DLFC 11.0 gpm for 1 When using one retainer and one o-ring up to
V3190-130 WS1 DLFC 13.0 gpm for 1 5 DLFC washers can be used for flow rates from
1 9 gpm up to 125 gpm.
V3190-150 WS1 DLFC 15.0 gpm for 1
V3190-170 WS1 DLFC 17.0 gpm for 1 When using two retainers and two o-rings, 5 DLFC
washers are used in one of the retainers and up to 4 more
V3190-200 WS1 DLFC 20.0 gpm for 1
DLFC washers can be used in the other retainer for flow
V3190-250 WS1 DLFC 25.0 gpm for 1 rates from 9 gpm up to 225 gpm.
V3765-01 WS3 DLFC HOUSING NPT
2 1
V3765BSPT-01 WS3 DLFC HOUSING BSPT
3 V3766 WS3 DLFC RETAINER 1 or 2
4 V3767 WS3 DLFC RETAINER COVER 1
5 V3768 WS3 DLFC RETAINER RING 1
6 V3769 O-RING 336 1 or 2
6
Larger hole for DLFC installation
1
2
4
6
1 V3768 retainer ring position
if one V3766 is used.
B indicates BSPT
N indicates NPT
Assemblies are shipped without drain line flow control (DLFC) washers.
Assembly instructions:
1. Determine the desired flow rate. Select a combination of V3190-XXX’s to arrive at the desired flow rate.
2. Using a drill or punch remove the desired knockout(s) in V3766. Each V3766 retainer contains two types of knock
outs. The larger knockouts are removed to install a DLFC. If two V3766 retainers are needed remove the smaller
diameter knockout that lines up with the DLFC installed in the other retainer. One or two V3766 retainers may be
used. When using one V3766 retainer V3190-XXX must be installed in the center hole. When using two V3766
retainers a V3190-XXX must be installed in the center hole of one of the retainers and the center hole on the other
retainer must remain open.
3. Smooth hole(s).
4. Install appropriate size(s) of drain line flow control washers. Pay close attention to proper DLFC orientation.
5. Assemble. Each V3766 retainer must have a V3769 o-ring installed. One each of the V3767 retainer cover and V3768
retainer ring must be used whether one or two V3766 retainers are used. The positioning of the V3768 retainer ring
varies depending on the number of V3766 retainer(s) used. Properly orientate the V3766(s) in the direction of flow.
6. Properly orientate the complete assembly in the direction of flow. Inlet and outlet threads are 3”.
WS2H and WS3 Drawings and Service Manual Page 27
V3063 MOTOR ALTERNATING VLV 2 NPT and V3063BSPT MOTOR ALTERNATING VLV 2 BSPT
1 •Operating Pressures:
20 PSI Minimum / 125 PSI Maximum
•Operating Temperatures:
40°F Minimum / 110°F Maximum
7 6
9
Page 28 WS2H and WS3 Drawings and Service Manual
1
•Operating Pressures:
20 PSI Minimum / 125 PSI Maximum
•Operating Temperatures:
40°F Minimum / 110°F Maximum
2
9 Piston Orientation 2
No Hard Water Bypass Valve
Configurations.
Piston Orientation 1
10 Motorized Alternating Valve
and No Hard Water Bypass
Valve Configurations.
11
WS2H and WS3 Drawings and Service Manual Page 29
•Operating Pressures:
2
20 PSI Minimum / 125 PSI Maximum
•Operating Temperatures:
3 40°F Minimum / 110°F Maximum
9 Piston Orientation
10
11
Page 30 WS2H and WS3 Drawings and Service Manual
•Operating Pressures:
20 PSI Minimum / 125 PSI Maximum
•Operating Temperatures:
1 40°F Minimum / 110°F Maximum
Piston Orientation 2
No Hard Water Bypass Valve
Configurations.
9
Piston Orientation 1
Motorized Alternating Valve
and No Hard Water Bypass
10 Valve Configurations.
11
WS2H and WS3 Drawings and Service Manual Page 31
2 •Operating Pressures:
20 PSI Minimum / 125 PSI Maximum
3 •Operating Temperatures:
40°F Minimum / 110°F Maximum
4
9
Piston Orientation
10
11
Page 32 WS2H and WS3 Drawings and Service Manual
V3060 WS2H BYPASS AUTO NPT, V3060BSPT WS2H BYPASS AUTO BSPT,
V3061BSPT WS2H BYPASS MANUAL BSPT and V3061 WS2H BYPASS MANUAL NPT
Quantity
Drawing No. Order No. Description
V3060 V3061
1 V3056 WS1.5&2ALT/2BYPASS AUTO CVRASY 1 N/A
2 V3476 WS MOTOR ASY 8 FT 1 N/A
3 V3272 WS2H SCREW 8X1 SS HEX SELF TAP 3 N/A
4 V3262-01 WS1.5&2ALT/2BY REDUCGEARCVRASY 1 N/A
5 V3110-01 WS1 DRIVE GEAR PLAIN 3 N/A
6 V3264 WS2H BYPASS REDUCTION GEAR AXLE 3 N/A
7 V3292 WS2H SCREW BSHD SS 1/4-20X1-1/2 8 8
8 V3059 WS1.5&2ALT/2BYPAS AUTODRIVEASY 1 N/A
9 V3268 WS2H BYPASS COVER DOME MANUAL 1 2
10 V3058 WS2H BYPASS MANUAL DRIVE ASY 1 2
V3057 WS2H BYPASS BODY ASY NPT
11 1 1
V3057BSPT WS2H BYPASS BODY ASY BSPT
Not Shown V3053 WS2H 2-1/2 GROOVELOCK CLAMP ASY 2 2
10
11
B indictates BSPT
N indicates NPT
WS2H and WS3 Drawings and Service Manual Page 33
5
2
Page 34 WS2H and WS3 Drawings and Service Manual
Possible Errors
Code Description
1001 No Encoder Pulses
1002 Unexpected Stall, Main Drive
1003 Run Time To Long, Main Drive
14001 Message Queue Full
15003 Run Time To Long, Bypass Drive
15010 Run Time To Short, Bypass Drive Could Not Drive Offline
15011 Run Time To Short, Bypass Drive Could Not Drive Online
16001 Communication Lost With Unit 2
16002 Communication Lost With Unit 3
16003 Communication Lost With Unit 4
16004 Regen List Full
17000 Run Time To Long, Separate Source Drive
17002 Run Time To Short, Separate Source Drive
18000 Reset Performed
18001 Power Loss
18002 Power Restored
WS2H and WS3 Drawings and Service Manual Page 35
a. Improper refill setting or refill fill a. Check refill setting and check refill
flow control is not sized properly flow control for proper refill rate.
b. Improper program settings b. Check program setting to make sure
9. Control valve uses too much they are specific to the water quality
regenerant and application needs
c. Control valve regenerates c. Check for leaking fixtures that may
frequently be exhausting capacity or system is
undersized
WS2H and WS3 Drawings and Service Manual Page 37
14. Motor drives intermittently a. Low power a. See Table 2 Software and Power Supply
during regeneration. Compatibility
Page 38 WS2H and WS3 Drawings and Service Manual
a. Foreign material is lodged in control a. Open up control valve and pull out
valve piston assembly and seal/ stack
assembly for inspection. Press NEXT
and REGEN buttons for about 3
seconds to resynchronize software with
piston position.
b. Mechanical binding b. Check piston and seal/ stack assembly,
check reduction gears, check drive
bracket and main drive gear interface.
Press NEXT and REGEN buttons
for about 3 seconds to resynchronize
16. Err – 1002 = Control valve software with piston position. Check
motor ran too short and was that pinion is not pressed up tight
unable to find the next cycle c. Main drive gear too tight against motor
position and stalled c. Loosen main drive gear. Press NEXT
and REGEN buttons for about 3
seconds to resynchronize software with
piston position. Verify free motion
by rotating main drive gear by hand,
driving piston in and out
d. Improper voltage being delivered to d. Verify that proper voltage is being
PC Board supplied. Press NEXT and REGEN
buttons for about 3 seconds to
resynchronize software with piston
position.
WS2H and WS3 Drawings and Service Manual Page 39
a. Master PC Board did not receive a a. Press NEXT and REGEN buttons
18. Err - 14001 = Message response from slave units. for about 3 seconds to resynchronize
queue full software with piston position.
a. Control valve programmed for “ON a. Press NEXT and REGEN buttons
SEP In” with out having a MAV for for about 3 seconds to resynchronize
separate source attached software with piston position. Re-
program valve to proper setting
b. MAV for separate source motor b. Remove power and check connection
wire not connected to System Board on MAV for separate source motor wire
or poor connection to System Board two pin connection
labeled AUX DRIVE. Make sure wires
in connector are inserted securely
23. Err – 17000 = MAV for
and no wires are broken. Clean pins
Separate Source valve motor
on System Board by plugging and
ran too long while trying to find
unplugging the connector a few times
proper park position
to remove excess protective coating.
Press NEXT and REGEN buttons
for about 3 seconds to resynchronize
software with piston position.
c. MAV for separate source motor not c. Properly insert motor into casing, do
fully engaged with reduction gears not force into casing. Press NEXT and
REGEN buttons for about 3 seconds
to resynchronize software with piston
position.
Page 42 WS2H and WS3 Drawings and Service Manual
Total
5
Total
3
3
2 Slow Rinse
2
Draw Draw
1
1
0
0 20 40 60 80 100 120
20 40 60 80 100 120
Pressure (psi)
Pressure (psi)
6
Total
10
5
Flow Rate (gpm)
Total
3 6
Slow Rinse
Draw
2
4
Draw
1
2
0
20 40 60 80 100 120
0
Pressure (psi) 20 40 60 80 100 120
Pressure (psi)
14 16
12 14
Total Total
Flow Rate (gpm)
10 12
8 10
Slow Rinse Slow Rinse
6 8
Draw
4 6 Draw
4
2
2
0
20 40 60 80 100 120
0
Pressure (psi) 20 40 60 80 100 120
Pressure (psi)
Order No. V3010-2G Order No. V3010-2H
US Units US Units
24
44
22
40
Total
20
Total 36
18
32
16
Flow Rate (gpm)
28
14
Slow Rinse
Slow Rinse 24
12
20
10
Draw
16
8
Draw
12
6
8
4
2 4
0 0
20 40 60 80 100 120
20 40 60 80 100 120
14 18
Total
Total
12
15
9
6
Draw Draw
6
4
2 3
0
0
100 200 300 400 500 600 700 800 900
100 200 300 400 500 600 700 800 900
Pressure (kPa)
Pressure (kPa)
Total
30
Flow Rate (lpm)
18
20
12
9 15
Draw
Draw
6 10
3 5
0 0
100 200 300 400 500 600 700 800 900 100 200 300 400 500 600 700 800 900
Pressure (kPa) Pressure (kPa)
50 60
Total Total
50
40
Flow Rate (lpm)
40
30 Slow Rinse
Slow Rinse
30
20
Draw Draw
20
10
10
0 0
100 200 300 400 500 600 700 800 900 100 200 300 400 500 600 700 800 900
80 Total
Total 140
70
120
60
Flow Rate (lpm)
100
50 Slow Rinse
Slow Rinse
80
40
60 Draw
30 Draw
40
20
10 20
0 0
100 200 300 400 500 600 700 800 900 100 200 300 400 500 600 700 800 900
Revision History:
7/14/2015
PAGE 27:
5 V3110-01 WS1 DRIVE REDUCING GEAR PLAIN 3
PAGE 28:
5 V3110-01 WS1 DRIVE REDUCING GEAR PLAIN 3
PAGE 29:
5 V3110-01 WS1 DRIVE REDUCING GEAR PLAIN 3
PAGE 30:
5 V3110-01 WS1 DRIVE REDUCING GEAR PLAIN 3
PAGE 31:
5 V3110-01 WS1 DRIVE REDUCING GEAR PLAIN 3
PAGE 32:
5 V3110-01 WS1 DRIVE REDUCING GEAR PLAIN 3
9/18/2015
PAGE 19:
WHEN INSTALLING THE METER, MAKE SURE THE ARROW ON THE METER BODY IS GOING THE SAME DIRECTION AS THE WATER
FLOW. THE METER CAN BE INSTALLED IN HORIZONTAL OR “UPFLOW” VERTICAL APPLICATIONS.
9/13/2016
PAGE 18:
WS2H/3 SCREW BTNSKT HD SS3/8-16X2
1 V3275 4
(7/32” hex allen wrench required)
Page 48 WS2H and WS3 Drawings and Service Manual