Digital Energy Meter
Digital Energy Meter
CT-2M
For LT Application
Counter Display
Specifications
• Digital measurement.
• CT Operated energy meter.
• 3 Ph 4 wire LT Application.
• Flush mounting compact design (96x96mm).
• Potential free pulse output for external energy totalization.
Accuracy
• Accuracy class 1.0.
• Accuracy maintained even under wide voltage fluctuation.
from -40% to +20% of Reference Voltage.
• Accurate reading even under rapid current fluctuation.
• Accurate reading for balance as well as unbalance loads.
2
Technical Information of Panel Meters
CT-2M Meter
(1) -/5A
(2) For direct reading with external CTs
Range
50/5A 60/5A 75/5A 100/5A 125/5A 150/5A 200/5A
250/5A 300/5A 400/5A 500/5A 600/5A 800/5A
Conformity to
IS 13779
Standards
G
(-)
Note:
1) Our Pulse Output is Open Collector Type.
2) External Resistance is to be used between DC Supply point & 'S' of our pulse output.
3) For 24V DC use an external resistance of 6.4K W.
4) This external resistance value will vary depending upon the external voltage (5-24V) being given by the user.
3
Technical Specification of CT-2M
CT-2M Meter
96 x 96 x 86mm (L x W x H)
Dimensions (with connectors)
The panel Meter is installed on the cabinet’s front panel and shall be secured
firmly with cabinet using 4 transparent Clips
Use 0.5mm2 to 2.5mm2 Cable for Voltage terminal & 3mm2 to 6mm2 cable for
Current terminals
0 0 0 0 2 8 kWh
4
Three Phase kWh Panel Meters - LCD Display
CT-2E
3 Phase Panel Meter
LCD Display
CT-2EA
3 Phase Panel Meter
LCD Display
Technical Features
Functions
Measures Energy accurately even under adverse supply conditions.
Range
LT 3 Phase 4Wire suitable for:
(1) -/5A CT Secondary
(2) For direct reading with external CTs of 5A Secondary. The
primary is selectable from 5A to 6000A in steps of 5A
Conformity to Standards
IS 13779 / IEC - 61036
Specifications
• Digital measurement
• CT Operated energy meter
• 3 Ph 4 wire LT Application
• Flush mounting compact design (96x96mm)
• Potential free pulse output for external energy totalization.
• Conforms to IS-13779 / IEC-61036
5
Other Features Accuracy
• LCD type display. • Accuracy class 1.0
• Low power consumption less than 1 watt per phase. Saving of more • Accuracy maintained even under wide voltage fluctuation from
than 30% over conventional meters. -40% to +20% of Reference Voltage
• Direct reading CT operated meter. • Accurate reading even under rapid current fluctuation.
• Potential free pulse output for energy. • Accurate reading for balance as well as unbalance loads.
• Finger touch-proof terminals for CT & Voltage connections.
• RS 485 MODBUS available to connect up to 32 Nos. CT-2EA on one
communication port over a cable distance of 1000 meters on a network.
Totally 255 devices can be connected on a MODBUS network. Anti Tamper Features
1. Records energy accurately under the following.
Tamper conditions:
a) One or Two phases are removed. OR
Technical Specification of CT-2E & CT-2EA Meter b) Neutral is Removed. OR
c) Reverse current condition.
Operating Voltage 240V, -40% to + 20% Phase to Neutral 2. Indication on LCD in case of CT reverse connections.
Frequency Range 50 Hz ± 5%
Display 6 digit for -/5A meter and 6+1 digit for
direct measurement with a digit after
decimal point
Note:
1) Our Pulse Output is Open Collector Type.
2) External Resistance is to be used between DC Supply point & point 'S'
of our pulse output.
3) For 24V DC use an external resistance of 6.8KΩ .
4) This external resistance value will vary depending upon the external
voltage (5- 24V) being given by the user.
6
Front View of CT-2E Applications of CT-2 Series Meters
1. kWh Display • Air Conditioning and Refrigeration Panels.
2. CT Reverse Indication • Industrial Application.
3. Calibration LED : 15000 imp/kWh for -/5A • Electrical Panels - Industrial HT & LT Panels.
4. “D” key used for increment the value while setting password & CT • Motor Control Centers, Distribution Control & Relay
Ratio Panels.
5. “ ” to confirm the entered value & to move the digit right to left • Equipment Monitoring.
• Transmission and Distribution Panels.
• In control panel to control different electrical loads.
• Genset, Solar and UPS applications.
1 • Test Benches and laboratory equipment.
• Special OEM application.
2
4
5
3
2
7
Ordering Information
The panel Meter is installed on the cabinet’s front panel and shall be secured
firmly with cabinet using 4 transparent Clips
Use 0.5mm2 to 2.5mm2 Cable for Voltage terminal & 3mm2 to 6mm2 cable for
Current terminals
+0.8mm
92mm -0.0mm
Wiring Diagram for CT-2EA
N
+0.8mm
-0.0mm
240 V P
N
92mm
P1 P2
L1 S1 S2
P1 P2
86mm L2 S1 S2
P1 P2
L3 S1 S2
REAR VIEW
G Rx+ Rx-
CT-2EA P A
Utility On Hrs U RS 485
N X
96mm 3.0 8 kWh S1
L1 l1
CAL L2 S2
L3 S1
ac 3 Phase, 4Wire kWh Meter l2
N S2
S1
G Pulse l3
S2
S O/P
Scroll Scroll Prog
Up Down
96mm
Communication
LV Network
PC
DIRIS CG
RS 232
RS 485
HEPL/CT-2 Series/06-20
or
PLC
or
M Other Systems