Date Printed: 7-Nov-23
PROJECT : PROPOSED 4-UNIT RESIDENTIAL APARTMENT
BERNABE III – BINARITAN MORONG, BATAAN
OWNER : MRS. JULIETA C. FLOJO
SUBJECT : SPECIFICATIONS
GENERAL NOTES
1. The Specifications is a summary of the proposed materials and finishes for the project, and shall be used
in conjunction with plans, details, schedules. For all materials and finishes, the specification governs. When
there is any discrepancy, notify the Designer.
2. For Doors and Windows, the Schedule of Doors and Windows governs.
3. Refer to plans, elevations, sections, and details for dimensions, layouts, sizes, and locations.
4. Colors, textures, styles shall be approved and agreed upon by the Designer and Owner.
I. SCHEDULE OF FINISHES
COD FLOOR FINISHES
E01 Front Steps - Finished Concrete
02 Living Area, Dining Area, and 600mm x 600mm glazed ceramic tiles
Kitchen -
03 All Toilet and Baths - 300mm x 300mm unglazed ceramic tiles
04 Laundry Area - Finished Concrete
05 All Bedrooms - 600mm x 600mm glazed ceramic tiles
WALL FINISHES
01 Exterior Walls - Plain cement in paint finish; use Boysen or
Davies Paint
03 Interior Walls - Smooth plain cement plaster in semi-gloss
paint finish; use Boysen or Davies Paint
04 Toilet and Baths - 300mm x 300mm glazed ceramic wall tiles or
approved equivalent, floor up to 1.2m.
- Smooth plain cement plaster in semi-gloss
paint finish; from 1.2m up to ceiling.
CEILING
01 All Rooms - Gypsum board ceiling on metal furring in flat
paint finish use Boysen or Davies Paint
- Moisture Resistant (MR) gypsum board on metal
02 All Toilet and Baths furring in flat paint finish use Boysen or
Davies Paint
KITCHEN, LAUNDRY, AND BATHROOM COUNTER FINISHES
01 Kitchen base cabinet. - 18mm thk. Marine plywood carcass in duco paint
finish
Kitchen Cabinet Doors and Drawer - 18mm thk. Marine plywood in duco paint finish
02 with concealed hinges and metal drawer guide and
Faces
stainless steel handle
Specifications PROPOSED 4-UNIT RESIDENTIAL Page 1 of 3
APARTMENT
Date Printed: 7-Nov-23
II. MATERIAL SPECIFICATION
CONCRETING WORKS
Footing, Wall Footing, Columns, - Minimum compressive strength of 3000 psi at 28 days
Floor Slab, Beams, Stair using washed sand and crushed rock
REINFORCING STEEL WORKS
Footing, Wall Footing, Columns, - Structural grade 33 deformed bar for 20mm diameter
Beams, and Slab and smaller
MASONRY & PLASTERING WORKS
- Standard 150mm thk. for int
- Mix using Portland cement and washed sand Class B
Concrete Hollow Blocks & Plastering
mixture
STEEL WORKS
Rafters & Nailers - Refer to structural design
CARPENTRY AND MILLWORKS
Fascia Board - 200mm x 18mm thk fascia board, use "Hardisenepa" or
approved equivalent
Door Jambs - from 50mm x 150mm k.d. solid wood in
Tanguile
mahogany stained finish
ROOFING WORKS
Roofing materials & other roof - Pre-painted Long Span Rib-type roofing
accessories
- Pre-painted Pre-bent Fascia Cover w/ Moulding
WATERPROOFING WORKS
Toilet & Bath - Use Davies Superdry Waterproofing or approved
equivalent
DOORS
See door schedule
WINDOWS
See window schedule
PLUMBING FIXTURES AND ACCESSORIES
Sanitary Lines/ Drainage Lines - Use Neltex brand PVC pipes and fittings or approved
equivalent
Water Lines - Use Unitec brand PPR pipes and fittings or approved
equivalent
Lavatories - Use Pozzi Brand or approved equivalent
Water Closet - Use Pozzi Brand or approved equivalent
Faucets - Use Pozzi Brand or approved equivalent
Shower - Use exposed mixing shower set w/ overhead shower,
telephone & hand shower and wall bibb tap
Kitchen Sink - Use stainless steel single bowl sink
Floor Drains - Use 4"x4" stainless steel
Specifications PROPOSED 4-UNIT RESIDENTIAL Page 2 of 3
APARTMENT
Date Printed: 7-Nov-23
ELECTRICAL FIXTURES AND DEVICES
Rigid Steel Conduits (RSC) - Use Meyer or approved equivalent
Electrical Conduits - Use Emerald brand or approved equivalent
Panel Board - Use Flush mounted
Circuit Breaker - Use General Electric bolt on type
Wires and Cables
- THHN
Utility and Junction Boxes - Ga.16 x 50mm x 100mm & 100mm x 100mm in dimension
Specialty and Convinces Outlet - Use Panasonic wide series
Wall Switches and Plates - Use Panasonic wide series
Lighting Fixtures
- Pinlight
- Downlight - Use LitesPlus brand or approved equivalent
Prepared By:
Jasper Ryan S. Gonzales, RCE
Civil Engineer
Specifications PROPOSED 4-UNIT RESIDENTIAL Page 3 of 3
APARTMENT
Date Printed: 1-Aug-21