Cytometry
Cytometry
From Wikipedia, the free encyclopedia Jump to: navigation, search This article needs additional citations for verification. Please help improve this article by adding citations to reliable sources. Unsourced material may be challenged and removed. (May 2009)
Analysis of a marine sample of photosynthetic picoplankton by flow cytometry showing three different populations (Prochlorococcus, Synechococcus, and picoeukaryotes) Flow cytometry (abbreviated: FCM) is a technique for counting and examining microscopic particles, such as cells and chromosomes, by suspending them in a stream of fluid and passing them by an electronic detection apparatus. It allows simultaneous multiparametric analysis of the physical and/or chemical characteristics of up to thousands of particles per second. Flow cytometry is routinely used in the diagnosis of health disorders, especially blood cancers, but has many other applications in both research and clinical practice. A common variation is to physically sort particles based on their properties, so as to purify populations of interest.
Contents
1 History o 1.1 Name of the technology 2 Principle 3 Flow cytometers 4 Data analysis o 4.1 Gating o 4.2 Computational analysis 5 Fluorescence-activated cell sorting 6 Labels o 6.1 Fluorescent labels
6.2 Quantum dots 6.3 Isotope labeling 7 Measurable parameters 8 Applications 9 See also 10 Bibliography 11 References 12 External links
o o
[edit] History
The first impedance-based flow cytometry device, using the Coulter principle, was disclosed in U.S. Patent 2,656,508, issued in 1953, to Wallace H. Coulter. Mack Fulwyler was the inventor of the forerunner to today's flow cytometers - particularly the cell sorter.[1] Fulwyler developed this in 1965 with his publication in Science.[2] The first fluorescence-based flow cytometry device (ICP 11) was developed in 1968 by Wolfgang Ghde from the University of Mnster [3] and first commercialized in 1968/69 by German developer and manufacturer Partec through Phywe AG in Gttingen. At that time, absorption methods were still widely favored by other scientists over fluorescence methods.[4] Soon after, flow cytometry instruments were developed, including the Cytofluorograph (1971) from Bio/Physics Systems Inc. (later: Ortho Diagnostics), the PAS 8000 (1973) from Partec, the first FACS instrument from Becton Dickinson (1974), the ICP 22 (1975) from Partec/Phywe and the Epics from Coulter (1977/78).
[edit] Principle
A beam of light (usually laser light) of a single wavelength is directed onto a hydrodynamically-focused stream of liquid. A number of detectors are aimed at the point where the stream passes through the light beam: one in line with the light beam (Forward Scatter or FSC) and several perpendicular to it (Side Scatter or SSC) and one or more fluorescent detectors. Each suspended particle from 0.2 to 150 micrometers passing through the beam scatters the ray, and fluorescent chemicals found in the particle or attached to the particle may be excited into emitting light at a longer wavelength than the light source. This combination of scattered and fluorescent light is picked up by the detectors, and, by analysing fluctuations in brightness at each detector (one for each fluorescent emission peak), it is then possible to derive various types of information about the physical and chemical structure of each individual particle. FSC correlates with the cell volume and SSC depends on the inner complexity of the particle (i.e., shape of the nucleus, the amount and type of cytoplasmic granules or the membrane roughness). This is because the light is scattered off of the internal components of the cell. Some flow cytometers on the market have eliminated the need for
fluorescence and use only light scatter for measurement. Other flow cytometers form images of each cell's fluorescence, scattered light, and transmitted light.
a flow cell - liquid stream (sheath fluid), which carries and aligns the cells so that they pass single file through the light beam for sensing a measuring system - commonly used are measurement of impedance (or conductivity) and optical systems - lamps (mercury, xenon); high-power water-cooled lasers (argon, krypton, dye laser); low-power air-cooled lasers (argon (488 nm), redHeNe (633 nm), green-HeNe, HeCd (UV)); diode lasers (blue, green, red, violet) resulting in light signals a detector and Analogue-to-Digital Conversion (ADC) system - which generates FSC and SSC as well as fluorescence signals from light into electrical signals that can be processed by a computer an amplification system - linear or logarithmic a computer for analysis of the signals.
The process of collecting data from samples using the flow cytometer is termed 'acquisition'. Acquisition is mediated by a computer physically connected to the flow cytometer, and the software which handles the digital interface with the cytometer. The software is capable of adjusting parameters (i.e. voltage, compensation, etc.) for the sample being tested, and also assists in displaying initial sample information while acquiring sample data to insure that parameters are set correctly. Early flow cytometers were, in general, experimental devices, but technological advances have enabled widespread applications for use in a variety of both clinical and research purposes. Due to these developments, a considerable market for instrumentation, analysis software, as well as the reagents used in acquisition such as fluorescently-labeled antibodies has developed.
Modern instruments usually have multiple lasers and fluorescence detectors. The current record for a commercial instrument is four lasers and 18 fluorescence detectors. Increasing the number of lasers and detectors allows for multiple antibody labeling, and can more precisely identify a target population by their phenotypic markers. Certain instruments can even take digital images of individual cells, allowing for the analysis of fluorescent signal location within or on the surface of cell.
was expanded by Len Herzenberg, who was responsible for coining the term FACS. Herzenberg won the Kyoto Prize in 2006 for his seminal work in flow cytometry. The cell suspension is entrained in the center of a narrow, rapidly flowing stream of liquid. The flow is arranged so that there is a large separation between cells relative to their diameter. A vibrating mechanism causes the stream of cells to break into individual droplets. The system is adjusted so that there is a low probability of more than one cell per droplet. Just before the stream breaks into droplets, the flow passes through a fluorescence measuring station where the fluorescent character of interest of each cell is measured. An electrical charging ring is placed just at the point where the stream breaks into droplets. A charge is placed on the ring based on the immediately prior fluorescence intensity measurement, and the opposite charge is trapped on the droplet as it breaks from the stream. The charged droplets then fall through an electrostatic deflection system that diverts droplets into containers based upon their charge. In some systems, the charge is applied directly to the stream, and the droplet breaking off retains charge of the same sign as the stream. The stream is then returned to neutral after the droplet breaks off.
[edit] Labels
[edit] Fluorescent labels
Main article: Fluorophore A wide range of fluorophores can be used as labels in flow cytometry. Fluorophores, or simply "fluors", are typically attached to an antibody that recognises a target feature on or in the cell; they may also be attached to a chemical entity with affinity for the cell membrane or another cellular structure. Each fluorophore has a characteristic peak excitation and emission wavelength, and the emission spectra often overlap. Consequently, the combination of labels which can be used depends on the wavelength of the lamp(s) or laser(s) used to excite the fluorochromes and on the detectors available.[16] The maximum number of distinguishable fluorescent labels is thought to be 17 or 18, and this level of complexity necessitates laborious optimization to limit artifacts, as well as complex deconvolution algorithms to separate overlapping spectra.[17]
Use of flow cytometry to measure copy number variation of a specific DNA sequence (FlowFISH)
volume and morphological complexity of cells cell pigments such as chlorophyll or phycoerythrin total DNA content (cell cycle analysis, cell kinetics, proliferation, etc.) total RNA content DNA copy number variation (by Flow-FISH or BACs-on-Beads technology) chromosome analysis and sorting (library construction, chromosome paint) protein expression and localization Protein modifications, phospho-proteins transgenic products in vivo, particularly the Green fluorescent protein or related fluorescent proteins cell surface antigens (Cluster of differentiation (CD) markers) intracellular antigens (various cytokines, secondary mediators, etc.) nuclear antigens enzymatic activity pH, intracellular ionized calcium, magnesium, membrane potential membrane fluidity apoptosis (quantification, measurement of DNA degradation, mitochondrial membrane potential, permeability changes, caspase activity) cell viability monitoring electropermeabilization of cells oxidative burst characterising multidrug resistance (MDR) in cancer cells glutathione various combinations (DNA/surface antigens, etc.) cell adherence (for instance pathogen-host cell adherence)
[edit] Applications
The technology has applications in a number of fields, including molecular biology, pathology, immunology, plant biology and marine biology. It has broad application in medicine (especially in transplantation, hematology, tumor immunology and chemotherapy, prenatal diagnosis, genetics and sperm sorting for sex preselection). In marine biology, the auto-fluorescent properties of photosynthetic plankton can be exploited by flow cytometry in order to characterise abundance and community structure. In protein engineering, flow cytometry is used in conjunction with yeast display and bacterial display to identify cell surface-displayed protein variants with desired properties.
[edit] Bibliography
Flow Cytometry First Principles by Alice Longobardi Givan. ISBN 0471382248 Practical Flow Cytometry by Howard M. Shapiro. ISBN 0471411256 Flow Cytometry for Biotechnology by Larry A. Sklar. ISBN 0195152344 Handbook of Flow Cytometry Methods by J. Paul Robinson, et al. ISBN 0471596345 Current Protocols in Cytometry, Wiley-Liss Pub. ISSN 1934-9297 Flow Cytometry in Clinical Diagnosis, v4, (Carey, McCoy, and Keren, eds), ASCP Press, 2007. ISBN 0891895485 Ormerod, M.G. (ed.) (2000) Flow Cytometry A practical approach. 3rd edition. Oxford University Press, Oxford, UK. ISBN 0199638241 Ormerod, M.G. (1999) Flow Cytometry. 2nd edition. BIOS Scientific Publishers, Oxford. ISBN 185996107X Flow Cytometry A basic introduction. Michael G. Ormerod, 2008. ISBN 9780955981203
[edit] References
1. ^ US 3380584, Mack Fulwyler, "Particle Separator", issued 1965-06-01 2. ^ Fulwyler, M. J. (1965). "Electronic separation of biological cells by volume". Science 150 (698): 910911. doi:10.1126/science.150.3698.910. PMID 5891056.edit 3. ^ DE 1815352, Wolfgang Dittrich & Wolfgang Ghde, "Flow-through Chamber for Photometers to Measure and Count Particles in a Dispersion Medium", issued 197101-14 4. ^ Kamentsky, Proceedings of the Conference Cytology Automation" in Edinburgh, 1970 5. ^ http://pingu.salk.edu/flow/fluo.html 6. ^ "TSRI Cytometry Software Page". http://facs.scripps.edu/software.html. Retrieved 2009-09-03. 7. ^ "PUCL Cytometry Software Page". http://www.cyto.purdue.edu/Purdue_software. Retrieved 2011-07-07.
8. ^ Qian, Yu; Wei, Chungwen; Eun-Hyung Lee, F.; Campbell, John; Halliley, Jessica; Lee, Jamie A.; Cai, Jennifer; Kong, Y. Megan et al. (2010). "Elucidation of seventeen human peripheral blood B-cell subsets and quantification of the tetanus response using a density-based method for the automated identification of cell populations in multidimensional flow cytometry data". Cytometry Part B: Clinical Cytometry 78B: S69. doi:10.1002/cyto.b.20554. 9. ^ "Immunology Database and Analysis Portal". https://www.immport.org/immportWeb/home/home.do?loginType=full. Retrieved 2009-09-03. 10. ^ "FLow analysis with Automated Multivariate Estimation (FLAME)". http://www.broadinstitute.org/cancer/software/genepattern/modules/FLAME/. Retrieved 2009-09-03. 11. ^ "flowClust". http://www.bioconductor.org/packages/2.5/bioc/html/flowClust.html. Retrieved 2009-09-03. 12. ^ http://www3.interscience.wiley.com/journal/117925662/abstract?CRETRY=1&SRET RY=0 13. ^ http://www.biomedcentral.com/1471-2105/10/145 14. ^ "FlowCAP - Flow Cytometry: Critical Assessment of Population Identification Methods". http://flowcap.flowsite.org/. Retrieved 2009-09-03. 15. ^ "FACS MultiSET System" (PDF). Becton Dickinson. http://www.bdbiosciences.com/pdfs/brochures/23-3428-02.pdf. Retrieved 2007-0209. 16. ^ Loken MR (1990). Immunofluorescence Techniques in Flow Cytometry and Sorting (2nd ed.). Wiley. pp. 34153. 17. ^ a b c Ornatsky, O.; Bandura, D.; Baranov, V.; Nitz, M.; Winnik, M. A.; Tanner, S. (2010). "Highly multiparametric analysis by mass cytometry". Journal of Immunological Methods 361 (12): 120. doi:10.1016/j.jim.2010.07.002. PMID 20655312.edit
Flow cytometry - How does it work? (Oregon State University) How a flow cytometer operates (MD Anderson Cancer Center) Learn About Flow Cytometry (Millipore) Powerpoint lectures on flow cytometry (Purdue University) Tutorials on fluorescence and flow cytometry (Invitrogen), including Introduction to Flow Cytometry Fluorescence SpectraViewer - Check the compatibility of your fluorophores when designing multicolor experiments (Invitrogen) Searchable database of fluorescent dyes (Graz University of Technology) Table of fluorochromes (Salk Institute) Java Fluorescence Spectrum Viewer (Becton, Dickinson and Company) MeSH Flow+cytometry FICCS - the Flow Informatics and Computation Cytometry Society History of Flow Cytometry by Bob Auer (hosted by Beckman Coulter) Flow Cytometry - A Basic Introduction (hosted by De Novo Software) Clinical Flow Wiki
v d eMedicine: Pathology Disease/Medical condition (Infection, Neoplasia) Hemodynamics (Ischemia) Inflammation Wound healing Cell death: Necrosis (Liquefactive necrosis, Coagulative necrosis, Caseous Principles necrosis, Fat necrosis) Apoptosis Pyknosis Karyorrhexis Karyolysis of pathology Cellular adaptation: Atrophy Hypertrophy Hyperplasia Dysplasia Metaplasia (Squamous, Glandular) accumulations: pigment (Hemosiderin, Lipochrome/Lipofuscin, Melanin) Steatosis Surgical pathology Cytopathology Autopsy Molecular pathology Anatomical Forensic pathology Dental pathology pathology Gross examination Histopathology Immunohistochemistry Electron microscopy Immunofluorescence Fluorescent in situ hybridization Clinical chemistry Hematopathology Transfusion medicine Medical Clinical microbiology Diagnostic immunology Immunopathology pathology Enzyme assay Mass spectrometry Chromatography Flow cytometry Blood bank Microbiological culture Serology Specific Myocardial infarction conditions Retrieved from "http://en.wikipedia.org/w/index.php?title=Flow_cytometry&oldid=458520238" Categories:
Cell biology Clinical pathology Blood tests Laboratory techniques Medical tests
Hidden categories:
Articles needing additional references from May 2009 All articles needing additional references
Personal tools
Namespaces
Article Discussion
Variants Views
Actions Search
Navigation
Main page Contents Featured content Current events Random article Donate to Wikipedia
Interaction Toolbox
What links here Related changes Upload file Special pages Permanent link Cite this page
Print/export
Languages
Franais Nederlands Polski Portugus Svenska This page was last modified on 1 November 2011 at 20:32. Text is available under the Creative Commons Attribution-ShareAlike License; additional terms may apply. See Terms of use for details. Wikipedia is a registered trademark of the Wikimedia Foundation, Inc., a non-profit organization. Contact us Privacy policy About Wikipedia Disclaimers Mobile view