LUXAFLOOR® PTX

Polyurethane Floor Topcoat PC 701


FEATURES • EXCELLENT HIGH BUILD BRUSH & ROLLER APPLICATION
• SUPERIOR GLOSS & COLOUR RETENTION
• GOOD CHEMICAL & ABRASION RESISTANCE
• AVAILABLE IN A WIDE RANGE OF COLOURS FROM THE LUXAFLOOR® COLOUR CHART
USES LUXAFLOOR® PTX is a high performance, high build recoatable polyurethane floor coating designed for ease of
use and exceptional flow out. LUXAFLOOR® PTX exhibits excellent gloss and colour retention under extreme UV
exposure. LUXAFLOOR® PTX can be used over LUXAFLOOR® LGE as a smooth floor coating, and with
LUXAFLOOR® AGGREGATES for slip resistant finishes.
LUXAFLOOR® PTX is available in a wide range colours from the LUXAFLOOR® Colour Chart and can be matched
to most colours in the Dulux® World of Colour range through the COLORFAST™ Tint System.

SPECIFICATIONS AS 4586:2013 Refer to Luxafloor Aggregates Technical Data Sheet for the full list of systems and ratings.
RESISTANCE GUIDE
WEATHERABILITY Excellent gloss and colour retention on SOLVENTS Resists splash and spillage of most
exterior exposure hydrocarbon solvents, refined petroleum
products and most common alcohols
HEAT RESISTANCE Up to 120°C dry heat WATER Excellent resistance to fresh and salt water
but not suitable for immersion
SALTS Unaffected by splash and spillage of neutral ALKALIS Good resistance to splash and spillage of
and alkaline salt solutions most common alkalis
ACIDS Excellent resistance to splash and spillage of ABRASION Excellent when fully cured
most acids

TYPICAL PROPERTIES AND APPLICATION DATA


CLASSIFICATION Acrylic polyurethane coating APPLICATION CONDITIONS
FINISH Gloss Min Max
COLOUR Wide range of tinted colours and N35 Light Air Temp. 10°C 45°C
Grey
Substrate Temp. 10°C 45°C
Relative Humidity 85%
Concrete Moisture <6%
COMPONENTS Two
VOLUME SOLIDS 70% (White) COATING THICKNESS (MICRONS)
VOC LEVEL <280 g/L (White) Min Max Recommended
FLASH POINT 42°C Wet film per coat 110 180 145
(μm)
POT LIFE 2 Hours (4 Litre kit, 25°C) Dry film per coat 75 125 100
(μm)
MIXING RATIO V/V Part A : 4 Part B : 1
THINNER 965-42166 Duthin® 040 SUITABLE Suitably primed diamond ground or track
SUBSTRATES blasted concrete

PRODUCT CODE 771-63001 White/Light Base PRIMERS Luxafloor® Primer, Luxafloor® LGE, and
771-63002 Deep Base Luxafloor® HSG
771-63003 Clear Base
771-38678 N35 Light Grey TOPCOATS Not applicable
976-H0160 Standard Hardener
APPLICATION Brush, roller, conventional, airless spray or
METHODS air assisted spray

DRYING CHARACTERISTICS AT 100 μm DRY FILM THICKNESS*


OVERCOAT
Floor Temperature Humidity Touch Light Traffic Full Cure Min Max
15° C 50% 10 Hours 36 Hours 7 Days 24 Hours Extended
25° C 50% 3 Hours 24 Hours 7 Days 10 Hours Extended

These figures are a guide only, as ventilation, film thickness, humidity, thinning and other factors will influence the rate of drying.

SPREADING RATE 7.0 square metres per litre equals 100 μm dry film thickness
assuming no losses NOTE: Practical spreading rates will vary depending on such factors as application method, ambient
conditions, surface porosity and roughness.

PC 701 July 2023 Page 1 of 3


LUXAFLOOR® PTX
TYPICAL SYSTEMS
This is a guide only and not to be used as a specification. Your specific project needs must be discussed with a Dulux Protective Coatings Consultant.
SURFACE ENVIRONMENT PREPARATION GUIDE SYSTEM DFT (μm)
1st Coat Luxafloor® LGE 125 μm
Remove curing agents and other
Exterior/ OR
CONCRETE surface contaminants. Diamond 100 μm
Interior 1st Coat Luxafloor® Primer
grind or track blast to provide a key nd 100 μm
2 Coat Luxafloor® PTX
Remove curing agents and other 1st Coat Luxafloor® LGE Thin by 10 - 15% 125 μm
Exterior/
CONCRETE surface contaminants. Diamond 2nd Coat Luxafloor® LGE 125 μm
Interior
grind or track blast to provide a key 3rd Coat Luxafloor® PTX Mix in Stir-In Aggregate Coarse @ 30g/L 100 μm
1st Coat Luxafloor® LGE Thin by 10 - 15% 125 μm
2
Sprinkle Broadcast Aggregate No. 36 at 50g/m while still wet
Remove curing agents and other
Exterior/ OR
CONCRETE surface contaminants. Diamond 100 μm
Interior 1st Coat Luxafloor® Primer
grind or track blast to provide a key Sprinkle Broadcast Aggregate No. 36 at 50g/m2 while still wet
2nd Coat Luxafloor® PTX 100 μm
NOTE: If application is by brush or roller, additional coats will be necessary to achieve the minimum DFT and full opacity
SURFACE Specifiers should follow the surface preparation guidelines from the data sheet of the primer used. The first coat
PREPARATION must be clean, sound and free from moisture, grease and other contaminants. If application of the second coat has
exceeded the recoat window of the first coat (refer to data sheet) then the entire surface MUST be abraded.
APPLICATION Mix each can thoroughly using a power mixer until the contents are uniform. Ensure bases have been tinted to the
correct colour before use. DULUX® ASSUMES NO RESPONSIBILITY FOR THE APPLICATION OF INCORRECT
COLOUR. Mix the contents of both packs together thoroughly with a power mixer and let stand for 10 minutes. Box
all containers before use to ensure colour consistency. Remix thoroughly before application.
BRUSH/ROLLER Apply even coats of the mixed material to the prepared surface. Thin, if necessary, with up to 50 ml/litre with Duthin®
040 (965-42166) to aid application. When brushing and rolling additional coats may be required to attain the
specified thickness. Note - If a highly decorative appearance is required it may be necessary to adjust thinning
levels (up to 100 – 150ml/litre), roller type and application technique.
CONVENTIONAL Thin up to 100 ml/litre with DUTHIN® 040 (965-42166) to aid atomisation.
SPRAY Typical Set-up Graco AirPro: 1.8mm (239543)
Pressure at Triton 308: 65-100 kPa (10-15 p.s.i.)
Pressure at Gun: 385-420 kPa (55-60 p.s.i.)
AIRLESS SPRAY Standard airless spray equipment such as a Graco Xtreme 45:1 with a fluid tip of 15-19 thou (0.38-0.48mm) and
an air supply capable of delivering 550-690 kPa (80-100 p.s.i.) at the pump. Thinning is not normally required but
up to 50 ml/litre of Duthin® 040 (965-42166) may be added to aid application.
PRECAUTIONS This is an industrial product designed for use by experienced Protective Coating applicators. Where conditions
may require variation from the recommendations on this Product Data Sheet contact your nearest Dulux ®
Consultant for advice prior to painting. Do not apply in conditions outside the parameters stated in this document
without the written consent of Dulux® Australia. Freshly mixed material must not be added to material that has been
mixed for some time. The rate of cure is dependent upon temperature. Do not apply at temperatures below 10°C.
Do not apply at relative humidity above 85% or when the surface is less than 3°C above the dewpoint. Ensure that
you read and understand the safety precautions on the Material Safety Data Sheets for the two components before
using. The recommended thinner MUST be used as some solvents react with the isocyanate hardener seriously
degrading the life of the coating. Under no circumstances should water or non-specified thinner be allowed to
contaminate the product. . Note – Rubber-tyred vehicles, particularly those using new high-performance car tyres,
may cause yellowing or staining on floor coatings. The rubber can contain materials that will migrate into the surface
coating and cause this effect. This is dependent on the composition and age of the tyre and may affect all coatings
to a greater or lesser extent. Refer to our tech note (https://www.duluxprotectivecoatings.com.au/media/1542/139-
concrete-floors-tyre-staining.pdf) to find out more about tyre staining and how it can be managed. Dulux Protective
Coatings.
CLEAN UP Clean all equipment with Duthin® 040 (965-42166) immediately after use
OVERCOATING Degrease with Gamlen CA 1 according to the manufacturer’s written instructions and all safety warnings. Test
adhesion of existing coating by standard cross hatch adhesion test. If the coating fails, remove it. Use a suitable
epoxy filling mortar to fill any cracks or defects in the concrete. Spot prime bare areas with Luxafloor® LGE.
Mechanically grind the existing coating to remove any gloss and create a good key for the new coating. Vacuum
clean to remove all dust.
SAFETY Read Data Sheet, SAFETY DATA SHEET and any precautions on container labels. SAFETY DATA SHEET
PRECAUTIONS is available from Customer Service (13 23 77) or www.duluxprotectivecoatings.com.au
STORAGE Store as required for a flammable liquid Class 3 in a bunded area under cover. Store in well-ventilated area away
from sources of heat or ignition. Keep containers closed at all times.
HANDLING As with any chemical, ingestion, inhalation and prolonged or repeated skin contact should be avoided by good
occupational work practice. Eye protection approved to AS1337 should be worn where there is a risk of splashes
entering the eyes. Always wash hands before smoking, eating, drinking or using the toilet.
USING Use with good ventilation and avoid inhalation of spray mists and fumes. If risk of inhalation of spray mists exists,
wear combined organic vapour/particulate respirator. When spraying, users must comply with their respective State
Spray Painting Regulations.
FLAMMABILITY This product is flammable. All sources of ignition must be eliminated in, or near the working area. DO NOT SMOKE.
Fight fire with foam, CO2 or dry chemical powder. On burning will emit toxic fumes.
WELDING Avoid inhalation of fumes if welding surfaces coated with this paint. Grind off coating before welding.

PC 701 July 2023 Page 2 of 3


COMPANY INFORMATION PACKAGING, TRANSPORT AND STORAGE
Dulux Protective Coatings a division of PACKAGING Available in 10 litre packs

DuluxGroup (Australia) Pty Ltd DuluxGroup (New Zealand) Pty Ltd TRANSPORTATION WEIGHT 1.43 kg/litre (Average of components)
1956 Dandenong Road, Clayton 3168 150 Hutt Park Road, Lower Hutt, NZ Part A: Class 3 UN 1263
DANGEROUS GOODS
A.B.N. 67 000 049 427 A.B.N. 55 133 404 118 Part B: Class 3 UN 1263
Dulux, and Luxafloor are registered trade marks of DuluxGroup (Australia) Pty Ltd.
Any advice, recommendation, information, assistance or service provided by Dulux Australia in relation to goods manufactured by it or their use and application is given
in good faith and is believed by Dulux to be appropriate and reliable. However, any advice, recommendation, information, assistance or service provided by Dulux is
provided without liability or responsibility PROVIDED THAT the foregoing shall not exclude, limit, restrict or modify the right entitlements and remedies conferred upon
any person or the liabilities imposed upon Dulux by any condition or warranty implied by Commonwealth, State or Territory Act or ordinance void or prohibiting such
exclusion limitation or modification. Products can be expected to perform as indicated in this sheet so long as applications and application procedures are as
recommended. Specific advice should be sought from Dulux for application in highly corrosive areas and for large projects to ensure proper performance.

PC 701 July 2023 Page 3 of 3

You might also like