Electromagnetic Flow Meter
Electromagnetic Flow Meter
OPTIFLUX 2000
1 Product features
1.1 Features......................................................................................................................... 3
1.2 Applications..................................................................................................................... 3
1.3 Options............................................................................................................................ 4
1.4 Body structure................................................................................................................ 4
1.5 Principle of operation......................................................................................................5
2 Converters and sensors
4.1 Installation.................................................................................................................... 20
4.2 Grounding..................................................................................................................... 21
5 Features of the liner material and electrode material
5.1 Main profermances of hte liner materials................................................................... 22
5.2 Main profermances of the electrode materials........................................................... 23
6 Rate-flow comparison table
2
1.Products features
1.1 Features
1.2 Applications
• Water abstraction
• Water purification and desalination
• Drinking water distribution networks
• Revenue metering or billing
• Leakage detection
• Irrigation
• Industry water
• Cooling water
• Wastewater
• Sewage and sludge
• Sea water
3
1.3 Options
Electromagnetic
Flowmeter
A reliable "friend" for industrial
applications and flow measurements of
process liquids & slurries
Flange connection version
For flowrates upto 380, 000m /h and more Meter
i om DN6 to DN3000mm
separate version
with connection box
signal converter in field housing
compact version
LCD display,four thin-film
button for dataset
DN3-DN3000mm
4
1.5 Principle of Operation
Flange connection flow meter Insertion type flow meter Battery powered flow meter
5
2.Converters and sensors
Compact type converter Battery powered type converter Remote type converter
Sensors
6
2.2 Converters
2.2.1 HTLD/Z converters drawing and features
Circinal Panel converter
Alarm
FQH ×1 m 3/ h Unit
indicator
Flow velocity ( FLS )
∑+ 00000013.5 m 3 Percentage ( FQP )
Ratio of emptiness ( MTP )
Forward and reverse intergated volumes
Deference of forward and reverse
Alarm
Alarm
FQH ×1 m 3/ h Unit
indicator
Flow velocity ( FLS )
∑+ 00000013.5 m 3 Percentage ( FQP )
Ratio of emptiness ( MTP )
Forward and reverse intergated volumes
Deference of forward and reverse
Alarm
Shift
Down ; minusl1, page down , exit key
Up; plus1, page up , enter key
Exterior size of the squared converter shells Keys on squared panel and large LCD display
7
1. Basic function
■ High-frequency square-wave exciting,exciting frequency 1/2 power frequency for grouting liquid
measure ;
■ No need to add empty pipeline measurement, and can measure continuously, alarm by fixed value;
■ Three integrator gross inside, respective register: Forward gross, reverse gross and minus value gross.
2.Especial function
■ Recording time when power turn-off, to record power broken time of instrument system automatically
■ Recording function of hour gross, to record the flux gross by hour, fit for timed measure;
explosion-proof;
The integrated squared shells: squared shells, shells connect with the flange directly
1
8
The split squared shells: squared shells (hang on the wall), Signal converters connect with cable of
sensor
Circinal Panel converter with flange connection sensor Squared panel converter with flange connection sensor
32 bit
CPU
preampli A/D ROM
fier
Communication
RS485 .etc
Interface
The converter can supply exciting current to the coil in the sensor of electronetic flowmeters,the head
amplifier amplifies the electromotive force from the sensor and converts it into standard signals of current or
frequency so that the signals can be used for displaying, controlling and processing. See structure of
converter circuit shown above.
9
2.2.1 HTLD/D converters drawing and features
Display panel
Battery powered converter
Pressure
Fowward and reverse total flow
Alarm display
Timer(second)
Battery
Instantaneous flow
Flow velocity
Percentage
Conductivity ratio
Shift key
Exit,down,munus one,next page
Enter,down,plus one,previously page
Depth
10
Basic parameters
■ Working temperature: -20 ℃ -50 ℃
■ Operating humidity: ≦ 95%
■ Protection class: IP68
■ Flow rate measuring range: 0 --- 15 m / s
■ Medium conductivity: clean water> 20 μs / cm
■ For measuring diameter: DN10 --- DN800
■ Supporting Accuracy class: 0.5
■ Measurement parameters: instantaneous flow, instantaneous flow
rate
■ Record parameters: Flow cumulative total
■ Detection and alarm parameters: Fluid empty pipe detection alarm,
the excitation current detection alarm
■ Scaled output signal: Unit volume flow pulse
■ Communication: RS485 (modbus protocol), GPRS
Battery life(month)
Measuring cycle 50mA excitation 20mA excitation
30S 120 200
15S 60 100
14S 56 93
13S 52 86
12S 48 79
11S 44 73
10S 40 66
9S 36 59
8S 32 53
7S 28 46
6S 24 39
5S 20 33
4S 16 26
3S 12 19
11
2.2 Sensors
Caliver DN3~DN3000mm
Nominal Pressure 0.6~4.0MPa(special pressure can be made to)
Accuracy ±0.5%,±0.3%or±0.2% are selectable
Liner material Teflon,pfa,f46,Neoprene,POLY
Electrode Type General type ,scraper type and replaceable type
Electrode material Stainless steel SUS316,Hastelloy C,Titanium,Tantalum Platinum-iridium,etc
Ambient Temperature 25℃below zero to 60℃
Ambient Humidity 5~100%RH(relative humidity)
Measuring Range 1500:1,flow rate<15m/s
Basic parameters Structure type Integral type,remote type,submersible type,ex-proof type
Protection Class IP65,IP68(optional)
Ex-proof Mark ExmdⅡT4
Product Standard JB/T 9248-1999Electormagnetic Flowmeter
flange diamension
Connecting flange and installing dimension see picture
4.0MPa(DN3-DN150) GB/T9119-2000
1.6MPa(DN200-DN600) GB/T9119-2000
1.0MPa(DN700-DN1000) GB/T9115-2000
0.6MPa(DN1200-DN3000) GB/T9115-2000
Connection flange drawing
(Special flange standard can be made to)
12
External and installing dimension
External dimension reference
Nominal diameterNominal pressure
L of PTFE liner L of Neoprene liner D H weight
3 200(PFA) 90 220 4
6 200(PFA) 90 220 5
10 200 / 90 220 6
15 200 / 95 220 8
20 200 / 105 220 10
25 200 / 115 223 12
32 200 / 140 240 13
4.0
40 200 200 150 250 14
50 200 200 165 263 15
65 250 250 185 283 18
80 250 250 200 290 20
100 250 250 235 318 25
125 250 250 270 350 28
150 300 300 300 380 30
200 350 350 340 430 50
250 450 450 405 495 70
300 500 500 460 547 95
350 550 550 520 602 120
1.6
400 600 600 580 665 140
450 600 600 640 720 160
500 600 600 715 783 200
600 600 600 840 897 280
700 700 700 895 982 350
800 800 800 1015 1092 400
1.0
900 900 900 1115 1192 480
1000 1000 1000 1230 1299 550
1200 1200 1200 1405 1488 660
1400 1400 1400 1630 1700 750
1600 1600 1600 1830 1924 850
1800 1800 1800 2045 2134 980
2000 2000 2000 2265 2344 1200
0.6
2200 2200 2200 2475 2549 1600
2400 2400 2400 2685 2754 2000
2600 2600 2600 2905 3169 2400
2800 2800 2800 2905 3169 2700
3000 3000 3000 3315 3369 2900
13
Flange diamension
Nominal pressure Caliber D K Φ n C
3 90 60 14 4 14
6 90 60 14 4 14
10 90 60 14 4 14
15 95 65 14 4 14
20 105 75 14 4 16
25 115 85 14 4 16
32 140 100 18 4 18
4.0
40 150 110 18 4 18
50 165 125 18 4 20
65 185 145 18 8 22
80 200 160 18 8 24
100 235 190 22 8 26
125 270 220 26 8 28
150 300 250 26 8 30
200 340 295 22 12 26
250 405 355 26 12 28
300 460 410 26 12 32
350 520 470 26 16 35
1.6
400 580 525 30 16 38
450 640 585 30 20 42
500 715 650 33 20 46
600 840 770 36 20 52
700 895 840 30 24 30
800 1015 950 33 24 32
1.0
900 1115 1050 33 28 34
1000 1230 1160 36 28 34
1200 1405 1340 33 32 28
1400 1630 1560 36 36 32
1600 1830 1760 36 40 34
1800 2045 1970 39 44 36
2000 2265 2180 42 48 38
0.6
2200 2475 2390 42 52 42
2400 2685 2600 42 56 44
2600 2905 2810 48 60 46
2800 3115 3020 48 64 48
3000 3315 3220 48 68 50
14
2.3.2 Wafer and tri-clamp(sanitary) connection sensor features and drawing
15
2.3.3 Insertion type sensor features and drawing
Terminal box
Flow directional φ 125
Seal parts
80
Ball valve
Mounting base
Installation depth Users pipeline Users pipeline
φ 50
Flow directional
Insertion rod
Measuring probe
16
3.Selection code table
17
3.2 HTLD/D SELECTION TABLE
Battery powered type electromagnetic flow meter
converter sensor
HTLD/D XXX X X X X X X XX X X X X X X X X X
main name
Caliber: DN3~DN600
Expression to three digits, the top two for the first, the second
caliber digital, the third of the number of 0 for the unit for
Standard pressure
1:0.6MPa 4:4.0MPa
2:1.0MPa 5:Others
3:1.6MPa
Liner materials
1: Teflon 4:ETFE
2: Polyurethane 5:PTFE*
3: Neoprene 6:F46
7:PFA 8:others
Electrode material:
1:316L 2:Hastelloy
3:Titanium 4:Tantalum
5:Platinum-iridium 6:Stainless steel covered with tungsten carbide 7:others
working environment
1: General place environment temperature ≤60℃ medium temperature≤80℃
2: General place environment temperature ≤60℃ medium temperature≤140℃(only with remote type)
grounding
0: unworthy grounding ring 1: worthy grounding ring
calibration
A: standard testing 0.5 class B: standard testing 0.2 class(15≤DN≤300)
Cable length
remote type:≤100m ,integral type is 00,if have special require, please description when place an order
outlet seal
1: 20mm plastic seal (manufacturer will install finish when leave factory) 2:G1/2
3:1/2NPT 4: 20mm plastic seal (the consumer install cable or Integral type )
connection mode:
F:flange connection J:Oil Charon connection K:Clamp connection C:insert connection
Structure Type H:: Integral type, R:remote type
power
1: 3.6V internal power supply
Display
1: Take the keyboard 3 lines display
output
0: RS485 output 1:pulse output
working environment
1.General place can not be used in seriflux
display direction
standard direction
Protection Class
1:Complete machineIP65 2:Complete machineIP67 3: sensor IP67, converter IP65
4: sensor IP68, converter Ip65 5: sensor IP68, converter IP67
Note: PTFE liner material of negative pressure ability is poor, such as existing in the pipeline has negative pressure, please consider using network type PFA or F46
18
3.3 HTLD/C SELECTION TABLE
Insertion type electromagnetic flow meter
19
4. Installation and grounding
4.1 Installation
Right Wrong
Right Right Wrong
Right Wrong
Right
Right Wrong
Wrong
Right
Stop valve
The valve full open The valve full open
20
5.2 Grounding
airproof gasket
2
>4mm copper line
ground Grounding load less than 10 Ohm
Metal pipe
connection line
airproof gasket
airproof gasket
flow direction
2
>4mm copper line
ground >4mm copper line
Grounding load less than 10 Ohm ground
Grounding load less than 10 Ohm
insulated gasket
flow direction
21
5. Features of the liner material and electrode material
Teflon
F46
Neoprene
QNb・@ッヲ@ァッッ、@・ャ。ウエゥ」ゥエケLイ・エイ。」エゥャゥエケ@。ョ、@。「イ。ウゥッョ@イ・ウゥウエ。ョ」・N
RNb・@イ・ウゥウエ。ョエ@エッ@ャッキ@。ゥ」、L。ャォ。ャゥ@。ョ、@ウ。ャエ@「オエ@ョッエ@ヲッイ@ックゥ、。エゥッョ@ュ・、ゥオュウN
aーーャケ@ゥョ@キ。エ・イLウ・キ。ァ・@エイ・。エュ・ョエ@。ョ、@ウャオイイケLュゥョ・イ。ャ@ウ・イッウゥエケ@ッヲ@ャッキ@。「イ。ウゥッョN
Polyurethane
22
5.2 Main Performances Of electrode materials
ta nle teel 3 6
ica in m i m o no co o i an o a a ion
Ha tell y
Ha tell y
tan u
antalu
Having strong resistance to corrosive mediums that is similar with glass. Almost applicable
in all chemical mediums.Except for hydrofluoric acid,oleum and alkali.
Plat nu u
Almost be applicable in all chemical mediums except for aqua fortis,ammonium salt.
23
6. Rate-flow Comparison
Rate-Flow comparison
3
m /h m/s
0.5 1 2 3 4 5 15(max)
mm
10 0.1414 0.2827 0.5654 0.8482 1.1309 1.4137 4.2411
15 0.3481 0.6362 1.2723 1.9085 2.5447 3.1809 9.5426
20 0.5655 1.1310 2.2619 3.3929 4.5239 5.6549 16.9646
25 0.8836 1.7671 3.5343 5.3014 7.0686 8.8357 26.5072
32 1.4476 2.8953 5.7906 8.6859 11.5812 14.4765 43.4294
40 2.2619 4.5239 9.0478 13.5717 18.0956 22.6195 67.8584
50 3.5343 7.0686 14.1372 21.2058 28.2743 35.3429 106.0288
65 5.9730 11.9459 23.8918 35.8377 47.7836 59.7295 179.1886
80 9.0478 18.0956 36.1911 54.2867 72.3823 92.4779 271.4336
100 14.1372 28.2743 56.5487 84.8230 113.0973 141.3717 424.1150
125 22.0893 44.1786 88.3573 132.5359 176.7146 220.8932 662.6797
150 31.8086 63.6173 127.2345 190.8518 254.4690 318.0863 954.2588
200 56.5787 113.0973 226.1947 339.2920 452.3893 565.4867 1696.4600
250 88.3573 176.7146 353.4292 530.1438 706.8583 833.5729 2650.7188
300 127.2345 254.4690 508.9380 763.4070 1017.8760 1272.3450 3817.0351
350 173.1803 346.3606 692.7212 1039.0818 1385.4424 1731.8030 5195.4089
400 226.1947 452.3893 904.7787 1357.1680 1809.5574 2261.9467 6785.8401
450 286.2776 572.5553 1145.1105 1717.6658 2290.2210 2862.7763 8588.3289
500 353.4292 706.8583 1413.7167 2120.5750 2827.4334 3534.2917 10608.7520
600 508.9380 1017.8760 2035.7520 3053.6281 4071.5041 5089.3801 15268.1403
700 692.7212 1385.4424 2770.8847 4156.3271 5541.7694 6927.2118 20781.6354
800 904.7787 1809.5574 3619.1147 5428.6721 7238.2295 9047.7868 27143.3605
900 1145.1105 2290.2210 4580.4421 6870.6631 9047.7868 11451.1052 34353.3157
1000 1413.7167 2827.4334 5654.8668 8482.3002 11309.7336 14137.1669 42411.5008
1200 2035.7520 4071.5041 8143.0082 12214.5122 16286.0163 20357.5204 61072.5612
1400 2770.8847 5541.7694 11083.5389 16625.3083 22167.0778 27708.8472 83126.5416
1600 3619.1147 7238.2295 14476.4589 21714.6884 28952.9179 36191.1474 108573.4421
1800 4580.4420 9160.8842 18321.7684 27482.6526 36643.5367 45804.4209 137413.2627
2000 5654.8667 113097.3360 22619.4671 33929.2007 45238.9342 56548.6678 169646.0033
2200 6842.3887 13684.7776 27369.5552 41054.3328 54739.1104 68423.8880 205217.6640
2400 8143.0080 16286.0163 32572.0326 48858.0490 65144.0653 81430.0816 244290.2448
2600 9556.7247 19113.4268 38226.8536 57340.2804 76453.7072 95567.1340 286701.4020
2800 11083.5387 22167.0774 44334.1548 66501.2322 88668.3095 110835.3869 332506.1608
3000 12723.4500 25446.9001 50893.8001 76340.7002 101787.6002 127234.5003 381703.5009
3 0.013 0.025 0.102 0.382