Multi Sensor Memory Logging
Multi Sensor Memory Logging
Applications:
Vertical, deviated or horizontal wells
Determination of downhole flowrates
Layering
Zonal distribution
Crossflow and leaks
Multiphase flow
Benefits:
High resolution
Portable for fast mobilisation, minimising rental period
Accurate and reliable
Can be run on slickline and coiled tubing
Allows rapid decisions
exprogroup.com
Production Monitoring
Technical Specifications:
Memory
Type Non-volatile EEPROM
Size Expandable up to 128Mb
Sample Rate From 0.1 sec to several days
Data Set Minimum of 30,000 on all channels
Length / OD 1.64ft / 111/16” (500mm / 43mm)
Full-bore Flowmeter
Size Various for use in up to 95/8” (244.5mm) casing
Measurement Range 100 to over 30,000 bbl/day in 7” (177.8mm) casing
Length / OD 2.95ft / 111/16” & 11/2“ (899mm / 43mm & 38mm)
In-line Flowmeter
OD 21/8” and 111/16” (54mm & 43mm)
Measurement Range 600 to over 60,000 bbl/day
Length 1.44ft (439mm)
CCL
Type Passive
Length / OD 1.54ft / 111/16” (470mm / 43mm)
Gamma Ray
Type Scintillation Crystal
Sensitivity 1 cps / API unit
Length / OD 1.93ft / 111/16” (587mm / 43mm)
Capacitance Array
Type Capacitance
Number of Fluid Sensors 12 (1 sensor per spring bow)
Orientation Sensor Indicates which sensor is “up”
Resolution ± 5% (dependant upon the distribution of phases in the wellbore)
Range 0-100% oil/water/gas
Length / OD 51.43”(1306mm) / 111/16” (43mm) (Spring bow fully closed)
Water Hold-up
Type Capacitance
Measurement Range 0.01 to 1 (accuracy decreases at high values)
Length / OD 2.18ft / 111/16” (665mm / 43mm)
Pressure
Type Shear quartz
Resolution < 0.008 psi
Linearity < 0.01% FS
Length / OD 1.02ft / 111/16” (310mm / 43mm)
exprogroup.com