Embedded Design

- Knowledge is Power -

HOME • BIOG RAPHY • FPG A PROJECT S • EMBED D ED C PROJECT S • ANT ENNA D ESIG NS 

• HARD WARE D ESIG NS • CONTACT

Three Phase Full-Wave Controller Bridge Rectifier


Author: Farid M, https://embeddeddesign.org/

In this article, I will talk about a six pulse three phase AC-DC converter design I
implemented on a Xilinix FPGA, Zynq-7000: https://amzn.to/2CZakDI. The converter uses
semiconductor controller rectifiers, SCRs, to generate +24VDC output voltage. Before I
start talking about how the digital control algorithm is implemented in VHDL, I would like
first to talk a bit about SCRs and how they work.

An SCR is a device made of four layers of alternating N-type and P-type semiconductor
material. As seen in the diagram below, an SCR has three terminals: Gate, Anode and
cathode and current flows through it only in the positive direction: from Anode to
Cathode. An SCR can be turned on in two ways: either by applying an increasing voltage
between the anode and cathode till it gets beyond the breakdown voltage or by sending a
positive pulse at the gate, which is the case in this project.

Figure1. Semiconductor Controlled Rectifier: https://amzn.to/2SIxSly

Theoretically, the DC output voltage of a three phase full-wave SCR bridge rectifier is a
function of what it is called: SCR firing time delay, which is a phase delay between the
moment an AC phase signal changes polarity from positive to negative or negative to
positive, and the rising edge of the positive gate pulse.

In my design each AC phase signal goes through an analogue Zero Crossing Detection
circuit, ZCD. As soon as the AC signal change polarity in either direction, an active high
pulse is generated. Since I am having a system powered up from a three phase power
source, this means I will have six zero crossing detection pluses generated at different
times: 2 pulses per one phase cycle. The rising edge of each of these pulses will be used
trigger a timer counter for the phase delay. Once this timer expires, depending on the
phase angle required, a pulse is sent to the gate of its dedicated thyristor.

The schematics below shows the circuit implementation of this three phase full wave
controlled rectifier. By looking at Figure2 and figure3, which shows power source that is
the three phase signals, I will explain the firing sequence for each rectifier thyristor:
T1,T2,T3,T4, T5, and T6. I would like to mention here that the purple, green and red
waveforms represent Phase A, Phase B, and Phase C respectively.

Figure2. Fullwave SCR AC-DC converter schematics

Figure3. Three phase AC Signals: 120º phase with each other

Each of the six SCRs are turned on when these two conditions occur:

1. When a phase power signal changes polarity from positive to negative or from negative
to positive. In other words, when a zero crossing detect signal becomes active high.
2. When firing time delay is expired: 60º +α(the firing phase delay). In this demo project, I
selected a phase delay α=0º.

The offset 60º is used here when we do not have access to the Neutral line, meaning the
load is connected as shown in Figure2. But if we have access to the Neutral line and the
negative terminal of the load, for example a battery, is connected to neutral line while
positive terminal is connected to positive output port, then the offset is equal to 30º, and
in this case the firing angle delay will be 30º +α.

The SCRs firing pulses sequence, assuming no access to the neutral line: Pulses are
sent after α+60º from the time a zero crossing detect signal becomes active high. For a 50
Hz AC power signal, this means that for a phase delay angle α=0º, the time delay is equal
to 60*20/360=3.33ms. Below is the firing sequence of all the thyristors gate pulses:

T1 is triggered by Pulse1 after 3.33ms (60º+α) from the instance V_an (Phase A)
changes polarity from positive to negative.
T2 is triggered by Pulse2 after 3.33ms (60º+α) from the instance V_cn (Phase C)
changes polarity from positive to negative.
T3 is triggered by Pulse3 after 3.33ms (60º+α) from the instance V_bn (Phase B)
changes polarity from negative to positive.
T4 is triggered by Pulse4 after 3.33ms (60º+α) from the instance V_an (Phase A)
changes polarity from positive to negative.
T5 is triggered by Pulse5 after 3.33ms (60º+α) from the instance V_Cn (Phase C)
changes polarity from negative to positive.
T6 is triggered by Pulse6 after 3.33ms (60º+α) from the instance V_bn (Phase B)
changes polarity from positive to negative.

Another important requirement to mention here is the pulse width. It is very important to
have the pulse ON for an adequate amount of time so that the SCR is energized properly.
Regardless of having access to neutral or not,the maximum pulse duration is 120º. Thus in
our example, the pulse duration formula is always: 180º-(60º+α), and this means that for
α=0º, the pulse duration will be 120º or 6.67ms. Please, note that this pulse duration will
get shorter more and more as the delay angle α increases. For example, for an α=90º, the
pulse duration will be: 30º or 1.67ms. However, with neutral line as the load reference, the
falling edge of the firing pulse will always occurs at 150º from the zero crossing, while, in
our example( no access to neutral line) this pulse falling edge will always occur at 180º
from the zero crossing event.

The diagram below shows the the six firing pulses for: T1 (probe0), T2(probe1), T3(probe2),
T4(probe3), T5(probe4), and T6(probe5). Notice the duration of the pulse when it is high:
since my system runs from a three phase 50 Hz source, 120 degrees corresponds to
6.67ms, which is roughly the case on my scope if I had increased my time resolution. Also
notice in Figure5 that the phase delay between all pulses is 60º.

Figure4: Six SCR Firing Pulses for a phase angle α=0 degrees

Figure5: Angle phase delay for α=0 degrees

In the next few paragraphs, I will be explaining how the code is implemented in VHDL. The
project is implemented on a Xilinix Zedboard: https://amzn.to/2CZakDI, and it uses AXI
protocol to transfer data from the processor system, PS, to the peripheral logic, PL, via
UART. In this project, the user makes a selection of the phase delay desired: α=0º, α=30º,
α=45º, α=60º, α=75º, α=90º, and the generated DC output is displayed onto an LCD. Below
are the main processes of the SCRs control algorithm.

VHDL Implementation
Phase Selection: This process gives the user the option to select the desired phase angle
delay. Note here that the system frequency used is 100MHz, and a full power cycle is
completed every 20 ms: when counter=2000000. Note here that “phaseSelect” register is
updated from the PS via AXI protocol.

PhaseSELECTION: process(clock,reset)
begin
if(reset='1') then
FiringPulse_RisingEdge<=0;
FiringPulse_FallingEdge<=0;
elsif(rising_edge(clock)) then
if(phaseSelect="000001") then --zero degrees delay
FiringPulse_RisingEdge<=333333; --0+60 degrees: pulse
duration=120degrees(6.67ms)
FiringPulse_FallingEdge<=1000000; --120 degrees +60 degrees
elsif(phaseSelect="000010")then --15 degrees degrees delay:pulse
duration=105degrees(5.83ms)
FiringPulse_RisingEdge<=416667;
FiringPulse_FallingEdge<=1000000;
elsif(phaseSelect="000100")then --30 degrees degrees delay:pulse
duration=90degrees(5ms)
FiringPulse_RisingEdge<=500000;
FiringPulse_FallingEdge<=1000000;
elsif(phaseSelect="001000")then --45 degrees degrees delay:
pulse duration=75degrees(4.16ms)
FiringPulse_RisingEdge<=583333;
FiringPulse_FallingEdge<=1000000;
elsif(phaseSelect="010000")then --60 degrees degrees delay:
pulse duration=60degrees(3.33ms)
FiringPulse_RisingEdge<=666667;
FiringPulse_FallingEdge<=1000000;
elsif(phaseSelect="010000")then --75 degrees degrees delay:
pulse duration=45degrees(2.5ms)
FiringPulse_RisingEdge<=750000;
FiringPulse_FallingEdge<=1000000;
elsif(phaseSelect="100000")then --90 degrees degrees delay:
pulse duration=30degrees(1.67ms)
FiringPulse_RisingEdge<=833333;
FiringPulse_FallingEdge<=1000000;
else
FiringPulse_RisingEdge<=333333; --zero degrees delay
FiringPulse_FallingEdge<=1000000;
end if;

end if;
end process PhaseSELECTION

Timer counters Process: This process is used to implement a timer for phase delay
whenever a zero crossing detection signal becomes active high.

TimerCounters:process (clock,reset)
begin
if(reset='1') then
PhaseCounter1<=0;
PhaseCounter2<=0;
PhaseCounter3<=0;
PhaseCounter4<=0;
PhaseCounter5<=0;
PhaseCounter6<=0;
SynchFlag<="000000";
elsif(rising_edge(clock)) then
PhaseCounter1<=PhaseCounter1+1;
if(SW1_CrossUp_Pulse='1')then
PhaseCounter1<=0; --Reset counter1
SynchFlag(0)<='1';
end if;
PhaseCounter2<=PhaseCounter2+1;
if(SW3_CrossDwn_Pulse='1')then
PhaseCounter2<=0; --Reset counter2
SynchFlag(1)<='1';
end if;
PhaseCounter3<=PhaseCounter3+1;
if(SW2_CrossUp_Pulse='1')then
PhaseCounter3<=0; --Reset counter3
SynchFlag(2)<='1';
end if;
PhaseCounter4<=PhaseCounter4+1;
if(SW1_CrossDwn_Pulse='1')then
PhaseCounter4<=0; --Reset counter4
SynchFlag(3)<='1';
end if;
PhaseCounter5<=PhaseCounter5+1;
if(SW3_CrossUp_Pulse='1')then
PhaseCounter5<=0; --Reset counter5
SynchFlag(4)<='1';
end if;
PhaseCounter6<=PhaseCounter6+1;
if(SW2_CrossDwn_Pulse='1')then
PhaseCounter6<=0; --Reset counter6
SynchFlag(5)<='1';
end if;

end if;
end process counters;

SCR Control Process: This process controls the firing sequence of each SCR.

SCRs_Control:process (clock,reset)
begin
if(reset='1') then
Thyristors_Sig'0');
elsif(rising_edge(clock)) then
--Thyristor T1 Control --PhaseA_CrossUp='1'
if(PhaseCounter1=FiringPulse_RisingEdge) then
Thyristors_Sig(0)<='1';
elsif(PhaseCounter1=FiringPulse_FallingEdge)then
Thyristors_Sig(0)<='0';
end if;
---Thyristor T2 Control --Phase3_CrossDwn='1'
if(PhaseCounter2=FiringPulse_RisingEdge) then
Thyristors_Sig(1)<='1';
elsif(PhaseCounter2=FiringPulse_FallingEdge)then
Thyristors_Sig(1)<='0';
end if;
--Thyristor T3 Control --PhaseB_CrossUp='1'
if(PhaseCounter3=FiringPulse_RisingEdge) then
Thyristors_Sig(2)<='1';
elsif(PhaseCounter3=FiringPulse_FallingEdge)then
Thyristors_Sig(2)<='0';
end if;
--Thyristor T4 Control --PhaseA_CrossDwn='1'
if(PhaseCounter4=FiringPulse_RisingEdge) then
Thyristors_Sig(3)<='1';
elsif(PhaseCounter4=FiringPulse_FallingEdge)then
Thyristors_Sig(3)<='0';
end if;
--Thyristor T5 Control --PhaseC_CrossUp='1'
if(PhaseCounter5=FiringPulse_RisingEdge) then
Thyristors_Sig(4)<='1';
elsif(PhaseCounter5=FiringPulse_FallingEdge)then
Thyristors_Sig(4)<='0';
end if;
--Thyristor T6 Control --PhaseB_CrossDwn='1'
if(PhaseCounter6=FiringPulse_RisingEdge) then
Thyristors_Sig(5)<='1';
elsif(PhaseCounter6=FiringPulse_FallingEdge)then
Thyristors_Sig(5)<='0';
end if;
end if;
end process;
-------------------------------------------------------------------

VHDL Simulation for a Six Pulses Three Phase Controlled Rectifier

The VHDL processes below simulates a three phase AC power system running at 50 Hz.
Also it simulates six thryistors firing at α=0º. Complete VHDL file can be downloaded from
my Github repository at: here

The three phase sine waveform were generated using a look up table as shown below:

type SineConstants_Array is array(0 to 399) of integer range -1241 to


1241; --signed(12 downto 0); --400 constants 11 bits each
constant SineConstants : SineConstants_Array :=
(19,39,58,78,97,117,136,156,175,194,213,233,252,271,290,309,328,346,365
,
384,402,420,439,457,475,493,511,528,546,563,581,598,615,632,649,665,681
,
698,714,730,745,761,776,791,806,821,835,850,864,878,891,905,918,931,944
,
956,969,981,993,1004,1015,1027,1037,1048,1058,1068,1078,1088,1097,1106,
1115,1123,1131,1139,1147,1154,1161,1168,1174,1180,1186,1192,1197,1202,1
207,
1211,1215,1219,1223,1226,1229,1231,1234,1236,1237,1239,1240,1241,1241,1
241,
1241,1241,1240,1239,1237,1236,1234,1231,1229,1226,1223,1219,1215,1211,1
207,
1202,1197,1192,1186,1180,1174,1168,1161,1154,1147,1139,1131,1123,1115,1
106,
1097,1088,1078,1068,1058,1048,1037,1027,1015,1004,993,981,969,956,944,9
31,
918,905,891,878,864,850,835,821,806,791,776,761,745,730,714,698,681,665
,649,
632,615,598,581,563,546,528,511,493,475,457,439,420,402,384,365,346,328
,309,
290,271,252,233,213,194,175,156,136,117,97,78,58,39,19,0,-19,-39,-58,-7
8,
-97,-117,-136,-156,-175,-194,-213,-233,-252,-271,-290,-309,-328,-346,-3
65,
-384,-402,-420,-439,-457,-475,-493,-511,-528,-546,-563,-581,-598,-615,-
632,
-649,-665,-681,-698,-714,-730,-745,-761,-776,-791,-806,-821,-835,-850,-
864,
-878,-891,-905,-918,-931,-944,-956,-969,-981,-993,-1004,-1015,-1027,-10
37,
-1048,-1058,-1068,-1078,-1088,-1097,-1106,-1115,-1123,-1131,-1139,-1147
,
-1154,-1161,-1168,-1174,-1180,-1186,-1192,-1197,-1202,-1207,-1211,-1215
,
-1219,-1223,-1226,-1229,-1231,-1234,-1236,-1237,-1239,-1240,-1241,-1241
,
-1241,-1241,-1241,-1240,-1239,-1237,-1236,-1234,-1231,-1229,-1226,-1223
,
-1219,-1215,-1211,-1207,-1202,-1197,-1192,-1186,-1180,-1174,-1168,-1161
,
-1154,-1147,-1139,-1131,-1123,-1115,-1106,-1097,-1088,-1078,-1068,-1058
,
-1048,-1037,-1027,-1015,-1004,-993,-981,-969,-956,-944,-931,-918,-905,-
891,
-878,-864,-850,-835,-821,-806,-791,-776,-761,-745,-730,-714,-698,-681,-
665,
-649,-632,-615,-598,-581,-563,-546,-528,-511,-493,-475,-457,-439,-420,-
402,
-384,-365,-346,-328,-309,-290,-271,-252,-233,-213,-194,-175,-156,-136,-
117,
-97,-78,-58,-39,-19,0);

Sine waves generation: This process generates three sine wave forms 120 degrees out of
phase from each other running at 50 Hz. Signal Sine1_out, Sine2_out,and Sine3_out
simulates Phase A, Phase B, and Phase C respectively. I selected the counter to reset at
5000 as I am running the FPGA at 100MHz.

-----------------------------------------------------------------------
---
--Sine waves generation:
-----------------------------------------------------------------------
---
SineWaves:process (clock,reset)
variable counter : integer range 0 to 5000;
begin
if(reset='1') then
Sine1_out<=0;
Sine2_out<=0;
Sine3_out<=0;
index1 <=0;
index2 <=133;
index3 <=266;

elsif(rising_edge(clock)) then
counter :=counter+1;
if(counter=5000) then
Sine1_out<= SineConstants(index1);
Sine2_out<= SineConstants(index2);
Sine3_out<= SineConstants(index3);

if(index1<399) then
index1<=index1+1;
else
index1<=0;
end if;

if(index2<399) then
index2<=index2+1;
else
index2<=0;
end if;

if(index3<399) then
index3<=index3+1;
else
index3<=0;
end if;

counter :=0;
end if;

end if;
end process SineWaves;

Zero Crossing Process: it simulates the zero crossing detection circuit used to detect the
very moment a phase signal changes polarity from positive to negative or from negative to
positive. The circuit generate a two clock cycles pulse whenever a zero cross detection
occurs.

CompProc: process(clock,reset)
begin
if(reset='1') then
Sine1_out_dly<=0;
Sine2_out_dly<=0;
Sine3_out_dly<=0;

Sinewave1_CrossDwn<='0';
Sinewave1_CrossDwn_dly1<='0';
Sinewave1_CrossUp<='0';
Sinewave1_CrossUp_dly1<='0';

Sinewave2_CrossDwn<='0';
Sinewave2_CrossDwn_dly1<='0';
Sinewave2_CrossUp<='0';
Sinewave2_CrossUp_dly1<='0';

Sinewave3_CrossDwn<='0';
Sinewave3_CrossDwn_dly1<='0';
Sinewave3_CrossUp<='0';
Sinewave3_CrossUp_dly1<='0';

elsif(rising_edge(clock)) then
-------------------------------------------------
Sinewave1_CrossUp_dly1<=Sinewave1_CrossUp;
Sinewave1_CrossDwn_dly1<=Sinewave1_CrossDwn;

Sinewave2_CrossUp_dly1<=Sinewave2_CrossUp;
Sinewave2_CrossDwn_dly1<=Sinewave2_CrossDwn;

Sinewave3_CrossUp_dly1<=Sinewave3_CrossUp;
Sinewave3_CrossDwn_dly1<=Sinewave3_CrossDwn;

Sine1_out_dly<=Sine1_out;
if((to_signed(Sine1_out,12)0)) then
Sinewave1_CrossDwn<='1';
Sinewave1_CrossUp=0)AND(to_signed(Sine1_out_dly,12)<0))then
Sinewave1_CrossUp<='1';
Sinewave1_CrossDwn<='0';
end if;

Sine2_out_dly <=Sine2_out;
if((to_signed(Sine2_out,12)0))then
Sinewave2_CrossDwn<='1';
Sinewave2_CrossUp=0)AND(to_signed(Sine2_out_dly,12)<0))then
Sinewave2_CrossUp<='1';
Sinewave2_CrossDwn<='0';
end if;

Sine3_out_dly <=Sine3_out;
if((to_signed(Sine3_out,12)0))then
Sinewave3_CrossDwn<='1';
Sinewave3_CrossUp=0)AND(to_signed(Sine3_out_dly,12)<0))then
Sinewave3_CrossUp<='1';
Sinewave3_CrossDwn<='0';
end if;
end if;
end process CompProc;

SCRs Control Process: This process implements these functionalities: It controls the six
timing counters used keep track of the angle firing timings for each thyristor,including the
gate pulse duration; it also simulate the DC output voltage generated from a three phase
AC power source. See figure6 for all of the system signals including the firing pulses. DC
output voltage is plotted in yellow.

In this example: FiringPulse_FallingEdge constant is set to 100000(180 degrees), while


FiringPulse_RisingEdge is set to 333333 which represents 60 degrees. Thus, the pulse
duration is 120 degrees for α=0º.

SCRs_Control:process (clock,reset)
begin
if(reset='1') then
PhaseCounter1<=0;
PhaseCounter2<=0;
PhaseCounter3<=0;
PhaseCounter4<=0;
PhaseCounter5<=0;
PhaseCounter6<=0;
Thyristors_Sig'0');

elsif(rising_edge(clock)) then
-------------------------------------------------------------------
---------------------------
--This is used to active firing angle timing counters
-------------------------------------------------------------------
--------------------------
if(Sinewave1_CrossUp='1')then
PhaseCounter1<=PhaseCounter1+1;
end if;

if(Sinewave3_CrossDwn='1')then
PhaseCounter2<=PhaseCounter2+1;
end if;
if(Sinewave2_CrossUp='1')then
PhaseCounter3<=PhaseCounter3+1;
end if;
if(Sinewave1_CrossDwn='1')then
PhaseCounter4<=PhaseCounter4+1;
end if;
if(Sinewave3_CrossUp='1')then
PhaseCounter5<=PhaseCounter5+1;
end if;
if(Sinewave2_CrossDwn='1')then
PhaseCounter6<=PhaseCounter6+1;
end if;
-------------------------------------------------------------------
---------------------------
--This is used to reset phase angle timing counters
-------------------------------------------------------------------
--------------------------

if((SW1_CrossUp_Pulse='1')OR(PhaseCounter1=FiringPulse_FallingEdge))the
n
PhaseCounter1<=0;
end if;

if((SW3_CrossDwn_Pulse='1')OR(PhaseCounter2=FiringPulse_FallingEdge))th
en
PhaseCounter2<=0;
end if;

if((SW2_CrossUp_Pulse='1')OR(PhaseCounter3=FiringPulse_FallingEdge))the
n
PhaseCounter3<=0;
end if;

if((SW1_CrossDwn_Pulse='1')OR(PhaseCounter4=FiringPulse_FallingEdge))th
en
PhaseCounter4<=0;
end if;

if((SW3_CrossUp_Pulse='1')OR(PhaseCounter5=FiringPulse_FallingEdge))the
n
PhaseCounter5<=0;
end if;

if((SW2_CrossDwn_Pulse='1')OR(PhaseCounter6=FiringPulse_FallingEdge))th
en
PhaseCounter6<=0;
end if;
--------------------------------------------------------------------
--------------------------
--This is used to control the firing time for gate pulses
--------------------------------------------------------------------
-------------------------
if(PhaseCounter1=FiringPulse_RisingEdge) then
Thyristors_Sig(0)<='1'; --T1
elsif(PhaseCounter1=FiringPulse_FallingEdge)then
Thyristors_Sig(0)<='0';
end if;

if(PhaseCounter2=FiringPulse_RisingEdge) then
Thyristors_Sig(1)<='1'; --
elsif(PhaseCounter2=FiringPulse_FallingEdge)then
Thyristors_Sig(1)<='0';
end if;

if(PhaseCounter3=FiringPulse_RisingEdge) then
Thyristors_Sig(2)<='1'; --
elsif(PhaseCounter3=FiringPulse_FallingEdge)then
Thyristors_Sig(2)<='0';
end if;

if(PhaseCounter4=FiringPulse_RisingEdge) then
Thyristors_Sig(3)<='1'; --
elsif(PhaseCounter4=FiringPulse_FallingEdge)then
Thyristors_Sig(3)<='0';
end if;

if(PhaseCounter5=FiringPulse_RisingEdge) then
Thyristors_Sig(4)<='1'; --
elsif(PhaseCounter5=FiringPulse_FallingEdge)then
Thyristors_Sig(4)<='0';
end if;

if(PhaseCounter6=FiringPulse_RisingEdge) then
Thyristors_Sig(5)<='1'; --
elsif(PhaseCounter6=FiringPulse_FallingEdge)then
Thyristors_Sig(5)<='0';
end if;
--------------------------------------------------------------------
--------------------------
--This is used to simulate DC output of the three phase AC input
power
--------------------------------------------------------------------
-------------------------
if(Thyristors_Sig(0)='1')then --T1
Sine1_Rec <=Sine1_Out;
elsif(Thyristors_Sig(3)='1')then --T4
Sine1_Rec <=Sine1_Out*(-1);
else
Sine1_Rec <=0;
end if;

if(Thyristors_Sig(2)='1')then --T3
Sine2_Rec <=Sine2_Out;
elsif(Thyristors_Sig(5)='1')then --T6
Sine2_Rec <=Sine2_Out*(-1);
else
Sine2_Rec <=0;
end if;

if(Thyristors_Sig(4)='1')then --T5
Sine3_Rec <=Sine3_Out;
elsif(Thyristors_Sig(1)='1')then --T2
Sine3_Rec <=Sine3_Out*(-1);
else
Sine3_Rec <=0;
end if;
end if;

AC_out<=Sine1_Rec+Sine2_Rec+Sine3_Rec;

end process;

and last but not least, the output signals have to be latched in a combinatorial circuit as
below:

Thyristors(0)<=Thyristors_Sig(0);
Thyristors(1)<=Thyristors_Sig(1);
Thyristors(2)<=Thyristors_Sig(2);
Thyristors(3)<=Thyristors_Sig(3);
Thyristors(4)<=Thyristors_Sig(4);
Thyristors(5)<=Thyristors_Sig(5);

The image below demonstrates the rectified six pulses DC output shown in yellow color.
Also notice that each current pulse is triggered 60 degrees after the previous pulse. Thus,
all pluses are 60 degrees apart from each other, and this is why we ended up having six
pulse for each full power cycle/period, which also means that DC output voltage has a 300
Hz ripple frequence(6 times AC signal frequency). Therefore, an LC low pass filter is
needed to filter out these voltage ripples.

ALso notice that only 2 thyristors are conducting at a time. In this example, these two SCRs
are conducting for a period of 60 degrees, but this conduction duration period will
decrease as we increase the phase delay, and this is the reason why the DC output
voltage decreases.

Figure6: Simulated rectified six pulses DC output from a three phase AC power source

The plotted signals below are for a phase angle α=90º. Here as it can be seen that only
one thyristor is energized at a time unlike the case with phase delays below 60 degrees.
Each thyristor here is turned on for only 30 degrees during an entire cycle. Also notice that
the delay between each active pulse is 30 degrees. The yellow plot show the expected DC
output; it has a saw-tooth waveform shape.

Figure7: Simulated rectified six pulses DC output for α=90º

As I mentioned at the beginning of this article, there is a direct relationship between the DC
output and the phase delay angle, and this is how they are related:

Controlled rectifier with free wheeling diode:

Conclusion: This AC-DC converter design did not have to be implemented on an FPGA at all,
it could have been implemented on a TI DSP processor or any other similar processor. It
was just the need of my application that I had to use an FPGA as I have other peripherals
and modules in my system that needed intensive computations within short amount of
time. I plan in the future to demo this project in this website on a TI C2000 processor.
Check back!

Author: Farid M, https://embeddeddesign.org/

If you find any of the projects posted here helpful to you while working on similar projects,
or you learned something from any of the topics discussed, please do not hesitate to make
a donation, whatever amount you can afford, just as a gesture of appreciation and to keep
this website alive and progressing so that its benefits extends to many younger engineers
and students around the globe

References:
1. https://en.wikipedia.org/wiki/Silicon_controlled_rectifier
2. http://www.worldcolleges.info/sites/default/files/enggnotes/three
phase_controlled_rectifiers.pdf
3. http://www.euedia.tuiasi.ro/lab_ep/ep_files/Lab_no_13_c1.pdf

Share this:

 Twitter  Facebook

Loading...

9 thoughts on “Three Phase Full-Wave Controller


Bridge Rectifier”
BESTLUIGI
July 21, 2019 at 6:26 pm

I see you don’t monetize embeddeddesign.org, don’t waste your traffic, you can
earn extra bucks every month with new monetization method.
This is the best adsense alternative for any type of website (they
approve all sites), for more details simply search in gooogle: murgrabia’s tools

 Like
Reply →

FARID
September 5, 2019 at 5:53 am

My only intention from writing in this website is to share knowledge. It’s not
meant for generating income!

 Like
Reply →

FARID
September 5, 2019 at 5:57 am

My only intention for launching this website is to promote knowledge. It is not


for generating income.

 Like
Reply →

Pingback: AXI4 for Controlling SCRs Delay Angle | SmartJade Author: Farid M,
https://embeddeddesign.org/

FARID
January 5, 2021 at 1:01 am

Please add the source: Author: Farid M, https://embeddeddesign.org/

 Like
Reply →

FARID
January 5, 2021 at 1:17 am

Please add the source: Author: Farid M, https://embeddeddesign.org/

 Like

Pingback: AXI4 for Controlling SCRs Delay Angle | SmartJade

FARID
January 5, 2021 at 1:16 am

Please add the source: Author: Farid M, https://embeddeddesign.org/

 Like
Reply →

ANONYMOUS
November 18, 2023 at 3:07 pm

Can you please provide the pic18 program for PWM generation for 3 phase full wave
controlled rectifier

 Like
Reply →

Leave a comment

This site uses Akismet to reduce spam. Learn how your comment data is processed.

Privacy & Cookies: This site uses cookies. By continuing to use this website, you agree to their use.
To find out m ore, including how to control cookies, see here: Cookie Policy B L O G AT W O R D P R ESS. C O M. Clo se and ac c ept

You might also like