Salicru SLC X-TRA Catalog

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

U N I N T E R R U P T I B L E P O W E R S U P P L I E S + L I G H T I N G F L O W D I M M E R S TA B I L I S E R S + V O LTA G E S TA B I L I S E R S & P O W E R L I N E C O N D I T I O N E R S + D C P O W E R S Y S T E M S + S TAT I C I N V E R T E R S + P H O T O V O LTA I C I N V E R T E R S

SLC X-TRA
UNINTERRUPTIBLE POWER SUPPLIES
SLC X-TRA
ABOUT SALICRU
Since 1965, SALICRU has designed, manufactured and commercialised power electronic solutions for the key sectors of business activity.

SALICRU’s mission is to provide innovative solutions and services to increase our customers’ productivity through the provision of high-quality
power supplies that will be continuous, clean, affordable, reliable and ecologically-friendly, in both alternating and direct current.

SALICRU has the broadest national coverage and has 8 international subsidiaries, with sales to over 40 countries worldwide, with well over 600,000
product units operating and running.

The main product lines are:

UPS (Uninterruptible Power Supply systems): Electronic protection with autonomy for all kinds of critical environments, ranging from 400 VA
to several MVA.

Lighting flow dimmer-stabilisers: Energy and CO2 emission saving for lighting installations.

Photovoltaic solar inverters: Generation of AC grid tied voltage using solar energy.

Voltage stabilisers: Regulating of the electrical supply.

DC systems and inverters: Solutions for AC/DC and DC/AC power supplies.

...AND THE ENVIRONMENT


SALICRU holds ISO-9001 and ISO-14001 certifications and its
products are designed and produced in full respect of the environment.
Similarly, we comply with all of the rules for the Recycling of Hazardous
Substances (RoHS).

SALICRU’s investment in the environment is longstanding: since


the first lighting flow dimmer-stabiliser (ILUEST+) came out in the
early 1990s, to the photovoltaic solar inverters (EQUINOX), the will
of the company has always been to produce equipment that is not
only respectful of the environment but also actively participates in
preserving it.

SALICRU is associated with the European GreenLight Programme,


a voluntary initiative for the fight against pollution, in particular, the
reduction in energy consumption in indoor lighting and street lighting
throughout Europe.

SALICRU
SLC X-TRA: UPS FROM 100 kVA TO 800 kVA
The SLC X-TRA series is one of the most reliable, high-performance
three-phase Uninterruptible Power Supply systems (UPS) on the
market, and provides protection and quality energy for a wide range
of applications. Based on the Voltage and Frequency Independent (VFI)
mode of operation, it has been developed using double conversion
IGBT technology with DSP control, which gives considerable savings
in the costs of operation and installation while it offers maximum
protection for the connected loads. This series has been conceived
to offer the best guarantees in meeting customers’ requirements and
needs and has been designed in full respect of the most demanding
environmental regulations. And to make the most of the equipments
potential, the system’s reliability can be increased by installing several
units in parallel.

We offer qualified technical support with over 45 years’ experience


and an established base of units installed, offering a wide range of
preventive/corrective services, 24/7 coverage and telemaintenance.

10 REASONS FOR CHOOSING SLC X-TRA


1 - Double conversion DSP+IGBT technology: Giving the system
the most advanced technology, protecting the loads against any
electrical disturbance.

SLC X-TRA 250 kVA 2 - Double input connection: This allows connection to 2 different
mains supplies to increase availability.

3 - Unit input power factor: Smaller consumption of reactive power


which translates into lower operating costs.

4 - Very low input current distortion (<3%): This avoids pollution


upstream, enables smaller generators and contributes to
improving the quality of the electrical system.

5 - High efficiency in On-line mode, between 95% and 96%: This


implies a considerable energy saving and reduces the need for
additional air-conditioning.

6 - Ready for loads with PF = 0.9: Optimal solution for active PFC
power supply servers.

7 - Efficiency >98% in Smart Eco-mode: Energy savings increased


with permanent On-line availability.

8 - Wide range of options available: System adaptation to the


specific requirements of each installation.

9 - Permanent technical cover: This improves productivity and


SLC X-TRA 600 kVA assures maximum working for the protected environments.

10 - SLC Greenergy solution: Conceived for increased efficiency and


energy-saving.

UNINTERRUPTIBLE POWER SUPPLIES (UPS)


DIGITAL SIGNAL PROCESSOR (DSP) THE HIGH EFFICIENCY REDUCES THE OPERATING
COSTS
The combination in the use of a DSP and a management microcontroller
coordinates the Power Factor Corrector module of the rectifier and the The SLC X-TRA UPS have a high efficiency between 95% and
output inverter, and provides significant advantages in managing the 96%, thus reducing operating costs and the cost of implementation
system: (without any need for an excessively large electrical installation), air-
conditioning (without considerably increasing the needs for cooling),
Greater precision through a distributed control. and operation (it enables economic savings throughout the useful life
Faster response. cycle), at the same time increasing the system’s reliability. Similarly,
Redundant and high speed communication. the technology used enables galvanic isolation of input/output,
Greater stability and reliability thanks to the total digital control. achieves low input harmonics and prevents all additional losses. The
Intuitive display with easier-to-read menus and simple navigation, high yield is achieved for the full range of loads.
with the possibility of adjusting all of the control parameters.
They are also able to work in the Smart Eco-mode, in which the loads
are supplied directly from the mains through the bypass line circuit
to achieve efficiency values of up to 98%. In this situation, the mains
HIGH PERFORMANCE RECTIFIER is continually monitored in order to supply the load with the utmost
reliability. If the mains is out of range, the load is transferred to the
The broad admissible margins on the input in voltage and frequency inverter in under 4 ms. When the mains’ conditions enable the UPS
variations give simultaneous benefits such as the lack of necessity to work correctly once more within the range, it returns to the Smart
to frequently use the batteries with unstable mains or optimal Eco-mode function. In this energy-saving mode, the rectifier keeps
synchronisation and operation with generators. the battery charged in order to provide an auxiliary supply (from the
batteries) if the main supply should fail.
The IGBT rectifier employed guarantees a Total Harmonic Distortion on
the input current (THDi) under 3% with a Power Factor of 0.99, thus 100,00
absorbing pure sinusoidal current and considerably optimising the 99,00
electrical infrastructure on the input:
98,00
97,00
Without any need for excessively large generators. 96,00
% Efficiency

Reducing the size of installation components: wiring, protections, 95,00


supply transformer... 94,00
Improving the installation in terms of quality and capacity. 93,00
Savings by avoiding the need to install harmonic suppressor filters.
92,00
91,00
90,00
20 30 40 50 60 70 80 90 100
1,20
FPin

% Load Smart Eco-mode


1,00 On-line

0,80 Efficiencies in On-line mode and Smart Eco-mode.

0,60 TRANSFORMER IN ZIG-ZAG


0,40
To be able to work with highly unbalanced loads, the secondary
0,20
winding of the output transformer has been set up in the form of
0,00 a zig-zag with neutral. We are therefore able to achieve maximum
0% 25% 50% 75% 100% nominal output capacity in kVA with non-linear loads and we cancel
LOAD
out the third order harmonics (and multiples) from the load.
Input Power Factor (PF)

12%
THDi

10%

8%

6%

4%

2%
Transformer in zig-zag
0%
0% 25% 50% 75% 100%
LOAD
Total Harmonic Distortion of input current (THDi)

SALICRU
INCREASED EFFICIENCY BATTERY MANAGEMENT
The very low Total Harmonic Distortion in the output voltage (THDv) As the batteries are electrochemical elements and their performance
results in an almost perfect supply voltage wave-form at critical loads, falls in time, the SLC X-TRA series monitors the state of the batteries
with the resulting improvement of their operation and longer life to give (Batt-Watch) in accordance with the manufacturer’s requirements.
the unit the possibility of handling non-linear and non-balanced loads,
with power factors below 0.9. On the basis of the characteristic I/V curve, the battery charge
starts with a constant current suited to the type used in order to
avoid giving excessive charge. In addition to a floating voltage
charge, a deep charge may be given to shorten the recharging time
in the event of successive mains failures in a short period of time,
and even to enable Ni-Cd batteries to be recharged.
ACTIVE POWER (kW)
1
Batt-Watch also reduces the ripple current which is one of the causes
CAPACITIVE INDUCTIVE of premature battery death, and protects them from damage due to
POWER FACTOR 0,9 0,9 POWER FACTOR
deep discharge and automatically compensates the charging voltage
0,8 0,8 of the batteries in line with the temperature in order to extend their
lifetime.

Using the Dynamic Charge Mode function, it is possible to charge


batteries with very long autonomy without increasing the recharging
time. This is achieved by increasing the maximum recharging current
of the batteries when the load is not absorbing the total power of the
inverter.
100% 80 60 40 20 0 20 40 60 80 100%

CAPACITIVE POWER (kVAr) INDUCTIVE POWER (kVAr) Similarly, the equipment includes the possibility of automatic or
Power capacity
manual battery tests as standard in order to forecast their capacity
and durability.

UNINTERRUPTIBLE POWER SUPPLIES (UPS)


GROWTH IN PARALLEL BY REDUNDANCY OR BY CAPACITY
The parallel control is distributed (it is not centralised) and communication between units is achieved with a CANBUS communication protocol to
make the system highly reliable and avoid ‘single points of failure’. It is extremely simple to start up systems in parallel to facilitate their installation
in the field itself and/or to add new units according to customer needs.
Rectifier connection Bypass connection

UPS 1 UPS 2 UPS 3

Parallel set-up
Loads Up to 8 UPS

EASE OF INSTALLATION, OPERATION AND MAINTENANCE


The SLC X-TRA series equipment can be installed against a rear wall
with other walls or cabinets to the sides thanks to the well studied
ventilation circuit which, by first cooling the most critical systems/
components, efficiently sends the air around the inside of the unit and
finally sends it out of the top. None of the modules in a higher power
system is larger than 1,200 mm width, to make it easier to handle in
the installation.

Their compact design provides considerable savings in space which is


still more important in locations where the available space is scarce,
and costly at the same time.

The built-in display provides maximum information and enables the


equipment to be handled simply and intuitively. The information
available includes the state of the UPS, alarms, measurements
and event log. It also includes a block diagram to make it easy to
interpret the supply to loads and an operation keyboard to work in
the different multilingual menus.

The design has also included front access to most of the components,
even the most critical. This front access makes it easier to service and
maintain, therefore reducing the MTTR. Equipment of over 400 kVA
is provided with a protection system in case the energy returns back,
with integrated Back-Feed protection and eliminating the need for any
external element.

Cooling flow

SLC X-TRA Display

SALICRU
FLEXIBILITY
The SLC X-TRA series is suitable for any kind of application: from Total protection is not guaranteed until the user has permanent
IT to the most demanding industrial environments. Thanks to its communication with the UPS and is always informed of its state.
wide range of accessories and options, it is possible to prepare The equipment therefore has the RS-232 and USB interfaces that
configurations and projects with complex architectures in order to allow it to connect to the outside world by means of the different
guarantee maximum power availability for the most critical loads. communication options (software for monitoring and closing operating
systems, integration in SNMP platforms, telemaintenance,…).

UNINTERRUPTIBLE POWER SUPPLIES (UPS)


AVAILABLE OPTIONS
PARALLEL/REDUNDANT KIT MONITORING OR MANAGEMENT SOFTWARE

A kit for installations needing to grow in power or redundancy in the For a single UPS by means of a PC/server through RS-232
system, enabling the different units to be interconnected. communication. It sends electronic mails, SMS, UPS programmed
shutdowns, etc.
EXTENDED AUTONOMIES

Configurations of batteries adapted for cases requiring a long back-up


time.

BACS II

A system for monitoring, regulation and alarm for lead batteries.


It guarantees full operation of the battery system by avoiding
unexpected or unforeseen faults caused by faulty batteries.

ETHERNET/SNMP ADAPTER OR GPRS MODEM

This enables the UPS to be controlled without having an associated SHUTDOWN SOFTWARE
local computer. Available in box and card versions for the UPS
intelligent slot. For computers in mixed networks in which different operating
systems work together.
INTERFACE TO RELAYS

Power-free contacts for remote alarm and state monitoring.

MODBUS PROTOCOL + RS-485 INTERFACE

For communication with compatible systems.

Ethernet/SNMP adapter

SALICRU
SICRES PLATFORM FOR REMOTE
TELEMANAGEMENT
TECHNICAL SPECIFICATIONS
Just as important as the equipment operation is MODEL SLC X-TRA
the possibility of controlling it from a distance, TECHNOLOGY On-line, double conversion, DSP control
which provides large savings in time and money INPUT Nominal voltage Three-phase 3 x 380 V / 3 x 400 V / 3 x 415 V
and assures constant information on the state of Voltage margin +15% / -20% (@ 3 x 400 V)

the units. SICRES is an Internet telemanagement Frequency 50/60 Hz (45-65 Hz)


Total Harmonic Distortion (THDi) <3%
platform whose functions include the supervision
Power factor >0.99
of all of the system parameters, information on the Nominal voltage Three-phase 3 x 380 V / 3 x 400 V / 3 x 415 V (3Ph+N)
OUTPUT
state of the UPS and detection of any possible faults Precision ±1% Steady state; ±5% Dynamic state (100% unbalanced)
to automatically advise the maintenance services. <20 ms recovery time
Frequency 50/60 Hz
TEMPERATURE AND HUMIDITY SENSORS Total Harmonic Distortion (THDv) Linerar load <1%
Non-linear load <5%
Obtention of environmental data of the room where Efficiency On-line 95% ÷ 96%

the UPS is located. Smart Eco-mode >98%


Admisible overload 125% for 10 min. / 150% for 1 min.
STATIC Type and activation criteria Solid state, microprocessor controlled
REMOTE DISPLAY BYPASS Input Independent
Voltage Three-phase 3 x 380 / 3 x 400 / 3 x 415 V (3Ph + N)
A replica of the display included in the unit for Frequency 50/60 Hz
controlling it from a distance. Transfer time Nil
Transfer to by-pass Immediate for overloads of over 150%
COMMON INPUT CONNECTION Retransfer Automatic after alarm disappearance
Admisible overload 1000% for 1 cycle
Single input for bypass and rectifier lines. MANUAL Type Without interruption
BYPASS 100 – 300 kVA As standard
RECTIFIER Structure Three-phase IGBT complete wave, soft start and PFC
TOP CABLE INPUT Protection Against transitory over-voltages
BATTERIES Type(1) Lead acid, sealed, maintenance free
Enabling connection in installations without raised Protection Against over-voltages and under-voltages
floor. Charging time 4 hours, @ 80% of capacity
Charge voltage regulation Batt-Watch
EXTERNAL MANUAL BYPASS Test Manual + Automatic
COMMUNICATION Ports RS-232, USB, Emergency Power Off (EPO),
Port of monitoring battery switch
Assembled in a cabinet for fixing to the wall, this
Display LCD + LED block diagram
assures full UPS electrical isolation for maintenance
GENERALS Operating temperature 0º C ÷ +40º C
purposes. Relative humidity Up to 95%, non-condensing
Operating altitude < 1.000 m.a.s.l.
ISOLATION TRANSFORMER FOR BYPASS LINE Acoustic noise @ 1 metre < 60 dB
STANDARDS Safety EN-62040-1-2; EN-60950-1
In cases where perfect galvanic isolation is Electromagnetic Compatibility (CEM) EN-62040-2
necessary between the equipment input and output, Operating VFI-SS-111 according to EN-62040-3
there is the possibility of installing a transformer to Quality and Environmental Management ISO 9001 and ISO 14001
separate the system, which can be connected on (1) Ni-Cd under request

either the input or the output depending on the


specific topology of the installation.
RANGE
AUTOTRANSFORMERS TO ADAPT THE VOLTAGE POWER CABINET NO. UPS DIMENSIONS WEIGHT BAT. CABINET DIM. WEIGHT
MODEL (kVA / kW) UPS + BAT (D x W x H mm.) (kg) (D x W x H mm.) (kg)

Located on the UPS input or output to adapt the SLC-100-XTRA 100 / 90 1+1 865 x 815 x 1705 630 850 x 1300 x 1900 875

voltage as required. SLC-125-XTRA 125 / 112.5 1+1 865 x 815 x 1705 662 850 x 1300 x 1900 1370
SLC-160-XTRA 160 / 144 1+1 865 x 815 x 1705 720 850 x 1300 x 1900 1370
SLC-200-XTRA 200 / 180 1+1 895 x 1220 x 1905 870 850 x 1300 x 1900 1550
SLC-250-XTRA 250 / 225 1+1 895 x 1220 x 1905 1020 850 x 1300 x 1900 1800
SLC-300-XTRA 300 / 270 1+2 895 x 1220 x 1905 1200 850 x 1300 x 1900 1370
SLC-400-XTRA 400 / 360 1+2 990 x 1990 x 1920 1820 850 x 1300 x 1900 1800
SLC-500-XTRA 500 / 450 1+2 990 x 2440 x 2020 2220 850 x 1300 x 1900 1800
SLC-600-XTRA 600 / 540 1+2 990 x 2440 x 2020 2400 850 x 1300 x 1900 2125
SLC-800-XTRA 800 / 720 1+3 990 x 3640 x 1920 3600 850 x 1300 x 1900 1925

UNINTERRUPTIBLE POWER SUPPLIES (UPS)


APPLICATIONS
IT-NETWORKS DATA CENTRES

Information is one of the most important capitals for any type of company. The critical elements’ costs in the data’s availibility (hosting, housing,
Any breakdown in the availability of information, or absolute loss in the packaging sending, airline bookings, etc.), the cost per hour in the
worst case, can cause high costs in terms of money and downtime event of mains failure are extremely high.
or system recovery. This damage, which is difficult to assume, can be
avoided with the right protection. It must also be stressed that the TELECOMMUNICATIONS
damage caused by faults in the electrical power supply is much higher
and more numerous than that caused by computer viruses. The phenomenal growth in the telecommunications sector has
increased demands from providers and subscribers alike on the
FINANCIAL SERVICES need for the uninterrupted availability of communication service. It
is therefore not unusual to enhance the supply by introducing long
The on-line, globalised operativity of world financial transactions must autonomies capable of giving coverage during systematic cuts for
have continuous back-up to assure uninterrupted operation in all areas grid upgrades and/or maintenance.
(bank offices, automatic cash dispensers, card payment authorisation
systems, transactions, continuous quotation,…) turning the reliability INFRASTRUCTURES
of the electrical supply as one of the key factors into achieving secure,
continuous and reliable transactions. SALICRU solutions meet these Hospitals: With needs ranging from the protection of all vital
requirements effectively. equipment in ICU, IVU, operating theatres and analysis and
laboratory equipment, to assuring temperature control and
INDUSTRIAL PROCESSES emergency lighting.

Electrically complex environments such as sub-stations or difficult Airports: Where the entire management of flight processes, control
loads (highly reactive) in many productive processes are just some of towers or check-in must guarantee operation free of errors and
the applications that require electrical backup equipment to provide unexpected incidents.
important protection, with the necessary flexibility to adapt to different
circumstances. Tunnels: Mostly lit day and night, duly signposted and ventilated,
they must be backed up by a leading system capable of dealing
with any problem.

SALICRU
STS – SERVICE & TECHNICAL SUPPORT
Your work on a business day should not be interrupted by a problem PREVENTIVE / CORRECTIVE INTERVENTIONS
in a UPS. SALICRU therefore provides its Service & Technical Support
(STS) department with its team of qualified engineers who will give Preventive: These are the necessary procedures on site in order to
you support in any eventuality or with any incident in your equipment, avoid possible future faults
in any place, on any day and at any time.
Corrective: Necessary procedures for repairing a fault.
PRE-SALES SUPPORT
MAINTENANCE CONTRACTS
Advice in choosing the model and the best options depending on the
application and requirements. In a wide range of forms and times, these guarantee maximum
efficiency and optimise the useful life span of your UPS.
STARTING UP
TELEMAINTENANCE CONTRACTS (SICRES)
The engineers from authorised SALICRU services go to the
installation site to check the cabling, to start up the equipment A remote monitoring service called SICRES, capable of giving
and to give basic training to the users. customers personalised treatment. With this permanent 24/7
telemaintenance system, when it detects an incident the SALICRU
TELEPHONE TECHNICAL SUPPORT Technical Service is capable of reacting immediately, informing the
customer and acting in consequence.
Just a call to our hot-line for an engineer to guide you on the
possible causes of the fault and, if necessary, to book a day and TRAINING COURSES
time for a site visit.
The training given by SALICRU will help you to operate your power
system safely: harmonics, neutral system, communication softwares,
electrical supervision, etc.

UNINTERRUPTIBLE POWER SUPPLIES (UPS)


U N I N T E R R U P T I B L E P O W E R S U P P L I E S + L I G H T I N G F L O W D I M M E R S TA B I L I S E R S + V O LTA G E S TA B I L I S E R S & P O W E R L I N E C O N D I T I O N E R S + D C P O W E R S Y S T E M S + S TAT I C I N V E R T E R S + P H O T O V O LTA I C I N V E R T E R S

Avda. de la Serra 100


08460 Palautordera
BARCELONA. Spain
Tel. +34 93 848 24 00
Fax +34 93 848 11 51
[email protected]
SALICRU.COM

DELEGATIONS and SERVICE & TECHNICAL SUPPORT (STS)

BARCELONA PALMA DE MALLORCA


BILBAO SAN SEBASTIÁN
CORUNNA SANTA CRUZ DE TENERIFE
GIJÓN SEVILLE
LAS PALMAS DE G. CANARIA VALENCIA
MADRID VALLADOLID
MÁLAGA ZARAGOZA
MURCIA

SUBSIDIARIES

CHINA MEXICO
FRANCE PORTUGAL
HUNGARY SINGAPORE
MOROCCO

REST OF THE WORLD

ALGERIA MALAYSIA
AUSTRIA NETHERLANDS
BELGIUM NIGERIA
BRAZIL PERU
BULGARIA PHILIPPINES
CHILE POLAND
CUBA ROMANIA
CZECH REPUBLIC RUSSIA
DENMARK SAUDI ARABIA
ECUADOR SLOVAKIA
EGYPT SWEDEN
ESTONIA SWITZERLAND
FINLAND THAILAND
GERMANY TUNISIA
GREECE UAE
Note: Salicru can offer other power electronics solutions according to requeriments of the application or technical specifications.
INDONESIA UKRAINE
IRAN UNITED KINGDOM
IRELAND UNITED STATES OF AMERICA
ITALY URUGUAY
JORDAN VENEZUELA
KUWAIT VIETNAM
LATVIA
LITHUANIA

Product Range
Uninterruptible Power Supplies (UPS)
Lighting Flow Dimmer Stabilisers
Voltage Stabilisers & Power Line Conditioners
DC Power Systems
Static Inverters
Photovoltaic Inverters

SALICRU REF. JM804B01 CODE 401AB000586 ED. AUGUST 2015 UNINTERRUPTIBLE POWER SUPPLIES (UPS)

You might also like