Calc
Calc
𝜃 𝑣𝑎𝑙𝑢𝑒𝑠
𝜇𝑛 1.07 Unitless
𝑘𝑛 1.053 Unitless
𝐾𝑑𝑛 1.04 Unitless
Wastewater Characteristics:
Constituent Concentration (g/m3)
BOD 480
Generally 0.4 to 0.8 Sbod 240 we take 0.5 times of BOD
COD 1230
Generally 0.4 to 0.6 Scod 530 we take 0.43 times of COD
Generally 0.2 to 0.4 rbCOD 307.5 we take 0.25 times of COD
TSS 155
Generally 80-90% of TSS VSS 131.75 we take 0.85 times the TSS
TKN 0
NH4-N 5.5
TP 0.5
Alkalinity 140 as CaCO3
Bcod/BOD ratio 1.6
a Find bCOD
b Find nbCOD
d Find nbVSS
0.548571429
11.80290814 g/g.d
0.177629314 g/g.d
S 0.66 g bCOD/m3
Now,
b
let assume,
A 185.3174803
B 12.2309537
Now,
197.548434 VSS/d
265.3507483 kg/d
ii
V 466.74 m3
Time 9.83 hr
c Determine MLVSS,
0.81217248
a 0.412435242 g/g.d
0.412435242 kg/kg.d
1.172389936 kg/m3.d
6 Determine the observed yield based on TSS & VSS,
874.7664124 kg/d
0.373490834
594.2476361 kg/d
24.76031817 kg/hr
8 Find Bubble aeration design - determine air flowrate
i using Appendix D
𝐶20 9.08 mg/L
𝐶12 10.77 mg/L
g 9.8 m/s2
M 28.97 kg/kg.mole
z_a 0
z_b 8 m
R 8314 kg.m2/s2.kg.mole.K
T 285.15 K
1.000958494
10.34919585 m
iv Detemine oxygen concentration
Assume, leaving aeration tank 15 %
9.72 m
4.4 m
11.68026763 mg/L
b Determine SOTR
𝛼 0.5
𝛽 0.95
F 0.9
C 2 g/m3
177.3546188
4.093314413
Assume
sBODe 10 g/m3
TSS 10 g/m3
BOD 16 g/m3
10 Diffusers Requirement
Fine bubble diffusers generally gives 4-6m3/hr Flow rate
We will take 5 m3/hr
Total Diffusers requirement = Air flowrate/diffuser flow rate