OE-18DPS30 Manual

Download as pdf or txt
Download as pdf or txt
You are on page 1of 46

Operating manual 1-8DPS Global

1-8DPS Global
g
1-8DPS30
1-8DPS55
Operating manual

1-8DPS75
Version 1.0

Gebruikershandle
Operating manual 1-8DPS Global 2/12

EC DECLARATION OF CONFORMITY
in accordance with Appendix II sub A of Directive 98/37/EC

BLASTRAC B.V.
Utrechthaven 12
NL - 3433 PN NIEUWEGEIN
Tel: 0031 (0)30 601 88 66
Fax: 0031 (0)30 601 83 33
[email protected]
The Netherlands

Declare under our sole responsibility that the machine as described below
Conforms with the Health and Safety requirements of the European Directive
of the machine Safety.

In case of changes to the machine without our written authorization this declaration loses
its validity.

Model: BLASTRAC 1-8DPS Global Serial number: …….

1. satisfies the conditions set out in the Machine Directive (Directive 98/37/EC); Low
voltage directive (73/23/CEE, as last amended; EMC directive 89/336/CEE, as last
amended)

2. satisfies the following harmonized standards:


NEN-EN 349, NEN-EN 418, NEN-EN 294 and NEN-EN 60204

Nieuwegein 04-03-2010

2
Operating manual 1-8DPS Global 3/12

Table of contents
EC Declaration of Conformity 02

1. Introduction 04

2. Machine description 04

3. Safety 05
Safety precautions
Safety regulations
Safety instructions

4. Initial operation 07
Checkpoints of power supply
Checkpoints of machine

5. Operating 08

6. Maintenance 09

7. Selection of abrasive 10

8. Technical data 11

Contact 12

3
Operating manual 1-8DPS Global 4/12

1. Introduction
It is important that all persons who are working with or maintaining this machine must
read the manual carefully and understand it fully. Keep this manual near to the machine,
to enable it be referred to at any time
Only authorized and trained personnel may operate this machine.

2. Machine description
The Blastrac blast cleaning machine 1-8DPS Global is a downward blasting machine with
a closed abrasive circuit designed for the pre-treatment of horizontal surfaces. The
bouncing impact of metallic abrasive onto the surface to be treated thoroughly removes
surface contaminants, coats of paint, sealants and thin coatings.
A suitable filter unit must be connected to the machine in order to separate the dust from
the abrasive. A specially designed dust collection system ensures dust-free operation of
the machine and clean air at the workspace.

1 Hose and cable clamp 7 Overdrive 13 Quick release pin


2 Dust hose connection pipe 8 Move forwards 14 Feed spout
3 Ammeter blast motor 9 Speed control 15 Clamp lever for cage adjusting
4 Hour counter 10 Travel switch
5 Emergency shutdown 11 Blastwheel On/Off
6 Abrasive control 12 Main switch
cable

4
Operating manual 1-8DPS Global 5/12

3. Safety
Before operating the machine, the personnel must be familiar with the safety instructions
given in this manual.
Keep this manual near to the machine, so it can always be consulted.

Safety precautions
The surface to be treated must be swept clean to remove stones, screws etc.
Never use the machine when the surface is not clear and if there is a risk of
tripping.
Make sure there is not any water on the surface to be treated.
Don’t get disturbed during the activities.
Remove any trailing electrical cables and or dust hoses from the surface to be
treated.
Always switch on the dust collector.

Safety regulations
Persons who do not operate the machine are not permitted to stay in the
surrounding of the machine. Don’t leave children anyway.
Keep the machine original; Use cables who are approved and not damaged. Never
remove the earth connecting of the supply cable and machine. Use only cables
with earth wire and connectors with a earth connecting.
Connect main power supply cable to a installation with a earth leakage circuit
breaker.
Inspect and test the electrical components of the machine regularly. This electrical
components have to satisfy to the requirements EN60204-1.
Always call a skilled electrician when you have questions about the safety of the
electrical components.
Work on electrical equipment or operating materials may only be undertaken by a
skilled electrician or by trained persons under the guidance and supervision of a
skilled electrician as well as in accordance with the electrical engineering
regulations.
Pull out the main plug during inspections and repairing on the machine.
Never operate the machine when workplace is wet.
Never stay in the rain with the machine.

5
Operating manual 1-8DPS Global 6/12

The following sticker is placed on the machine.

Meanings of these symbols are:


Ear protection is obliged
Safety glasses with lateral protection are obliged
CE-mark on this machine
Safety shoes obliged
Consult the manual before operating the machine

Personnel must tie back long hair and not wear loose clothing or jewellery including rings.
Wear gloves and dust mask during operating the machine.

Safety instructions
Abrasive can escape from the sides of the blast head at high speed. Wear safety
glasses with lateral protection and close-fitting protective clothing.
Be very careful with inserting the quick release pin
The machine, specially the handle grip must be free of fats and has to be dry.
The dust container / bag of the filter unit must be emptied regularly. Comply with
the local waste treatment regulations considering the removed material.
The weight of the 1-8DPS Global is 155 kg. By transport the machine with a crane
or lift, use the lifting eyes of the machine.
Pay attention that the drive unit do not turn away during lifting the machine.

6
Operating manual 1-8DPS Global 7/12

4. Initial operation
Before using the machine it is of great importance to inspect the machine.
It is not permitted to use the machine if the machine safety is not according the
checkpoints below.

Checkpoints power supply


Use only extension cables for extending the main cable that are sized and marked
in accordance with the overall power consumption of the machine.
Electrical cables must be fully unwind of them reels.
No damage is permitted for electrical cables.
Use a electrical power supply connection with earth connecting.

Checkpoints of machine
Safety functions and operating functions must work correct.
Check the following parts for damage and wear: blastwheel, feedspout, liners,
magnet- and brush sealing.
No loose bolts and nuts permitted
No any damage of electrical components permitted.
Dust hose must be undamaged and the connection must be reliable.
Check de parts of the separator on wear and defects. Remove foreign bodies and
dust deposits.

7
Operating manual 1-8DPS Global 8/12

5. Operating
During operating the 1-8DPS Global, the following additional safety instructions must be
followed closely.

Before switch on
Check if the distance from magnet to the floor is 8 – 10 mm. Check this height
with aluminium strips.
Check the distance from brush sealing to the floor. This may be max. 1 mm.
Fill the separator equally with the selected abrasive up to the bottom of the
separator tray. The magnetic valve must be closed whilst doing this.
Connect the blast machine and filter unit with the dust hose. This connection must
be reliable.
Connect the power supply cable of the filter unit with the generator. Be sure that
electrical power supply is correct.

Switch on the machine

Before switch on the blast machine, switch on the filter unit.


Press the green push button “Blast wheel ON” and check the rotating direction of
the blast motor. The correct direction is given with a arrow on the housing of the
motor.
Select the speed using the speed control knob. (item 9 of machine description)
When the machine is traveling pull the abrasive control cable to open the magnetic
valve. Observe the ammeter. It may indicate the full load amperage. After having
blasted aprox. 2 m, close the abrasive valve, stop the machine and check the
blasted surface.
If the ‘hotspot’ is too much on the right, turn clockwise the blastwheel cover a
little bit. Loose the clamp lever for cage adjusting (item 15 of machine description)
and hammer on the finger to adjust the position. Tighten the clamp lever after
adjusting.

Switch off the machine

Close the abrasive valve


Press the red button “Blast wheel OFF”
Press the red button “Drive OFF”
Switch the main switch to position “OFF”
Pull out the connector of the main power supply of the machine.
Switch off the filter unit.
Wait for standstill of all drives before any inspection or maintenance works are
started.

8
Operating manual 1-8DPS Global 9/12

6. Maintenance
Changing the liners
Loose the press bolt of the top liner and remove the cover.
Loosen the nuts of the side liners and plenum liner. Take them out at the bottom
of the housing.

To mount the liners, keep on the following sequence:


First place the plenum liner and fix it with the nuts.
Place the side liners inside the housing. The sideliners may stick out the body for
max. 1mm. Tighten the nuts.
Place the top liner in the housing and make sure that the top liner sits close to the
edges of the side liners.
Place the cover and tighten the bolts.
Tighten the pressure bolt of the top liner slightly and press the top liner against
the side liners.

Changing the tune-up kit


De tune-up kit consists of the blastwheel, the cage and a bolt.

Remove the feed spout


Remove the cage clamps
Remove the cage and blastwheel cover plate
Block the blastwheel and remove the central fixing bolt
Take the blastwheel out of the housing

Use a new central fixing bolt when mounting a new blastwheel

Place the blastwheel on the hub and tighten the central fixing bolt.
Fix the blastwheel cover plate with 3 nuts and clamping handle.
Insert the control cage in the center and clamp the cage with the control clamps
so that the blastwheel can rotate freely
Turn the blastwheel manually. It must rotate freely.
Place the feed spout between the abrasive valve and the cage.

Clean the machine every day with air and non-aggressive materials. Never use a high
pressure water cleaner to clean the machine.
Store the cleaned machine in a dry room. Protect the electrical motor from moisture, heat
dust and shocks. Remove the abrasive out of the abrasive storage hopper.
All repair work has to be done by qualified Blastrac personnel, this guarantee a save and
reliable machine.
Any guarantee on the machine is expired when:

By not using original Blastrac spareparts and abrasive.


When repair work is not done by qualified Blastrac personnel.
When changes, add ons or conversions are undertaken without written permission
of Blastrac.

9
Operating manual 1-8DPS Global 10/12

7. Selection of abrasive

Media nr. 2
Is often used when the surface is only subsequently sealed.
− creates fine profiles, e.g. on vacuum concrete and non-glazed tiles
− removes thin layers of rust on steel surfaces
− removes thin layers of paint

Media nr. 3
− creates a fine to medium texture on concrete.
− removes glazing from tiles prior to subsequently coating with antiskid floor sealings
− removes old impregnations and coatings about 1 mm thick

Media nr. 4
Standard abrasive, suitable for about 50-60 % of all applications. Creates a medium profile
on concrete. Fulfils the same purpose as Media No. 3 when a higher speed of the machine is
required, e.g. on asphalt, in order to keep the thermal load low.
− removes laitance from new concrete
− roughening of smooth concrete or natural stone
− removes coatings with a thickness of 1-3 mm
− cleaning of steel surfaces

Media nr. 5
This media is used to create a coarse profile or to increase the work speed in the case of
surfaces hard to treat.
− removes sediments on concrete prior to coating
− removes thick paint coatings or rust from steel surfaces, bridges, tanks, etc.
− removes flexible coatings on parking house decks
− removes road markings and retexturing of asphalt and concrete roads

Media nr. 8
Only as an addition to Media No. 3, No. 4 and No. 5 with maximum 30% content.
Media No. 8 should never be used without blending since otherwise the wear in the machine
as a whole would increase disproportionately.
− removes polyurethane coatings
− removes adhesive remnants
− removes rubber deposits
− penetrates coatings hard to remove
− also suitable to be used on steel for extraordinary roughness

10
Operating manual 1-8DPS Global 11/12

8. Technical data

1-8DPS Global
Power 3KW
consumption 5.5kW
blast motor 7.5kW
Electrical 230V SF 50/60Hz
connection 400V / 50Hz
(voltage is given 400V / 60Hz
on the control
box)
Blast width 200 mm

Drive speed 0 – 23 m/min

Length 1700 mm

Width 380 mm

Height 1050 mm

Weight 155 kg

Noise level 85dBa


(under load)
Vibration level 1.6 RMS
Allows 18.8 hrs. of working
with the mentioned equipment
without having to use anti
vibration precaution measures.

Dust hose Ø75 mm


connection

11
Service manual 1-8DPS Global

1-8DPS Global
1-8DPS30
Gebruikershandleiding
1-8DPS55
1-8DPS75
Version 1.2
Service Manual
Service manual 1-8DPS Global 2/13

EC DECLARATION OF CONFORMITY
in accordance with Appendix II sub A of Directive 2006/42/EC

BLASTRAC B.V.
Utrechthaven 12
NL - 3433 PN NIEUWEGEIN
Tel: 0031 (0)30 601 88 66
Fax: 0031 (0)30 601 83 33
[email protected]
The Netherlands

Declare under our sole responsibility that the machine as described below
Conforms with the Health and Safety requirements of the European Directive
of the machine Safety.

In case of changes to the machine without our written authorization this declaration loses
its validity.

Model: BLASTRAC 1-8DPS Global Serial number: ……….

1. satisfies the conditions set out in the Machine Directive (Directive 2006/42/EC);
Low voltage directive (2006/95/EC, as last amended; EMC directive 2004/108/EC,
as last amended)

2. satisfies the following harmonized standards:


NEN-EN 349, NEN-EN 418, NEN-EN 294 and NEN-EN 60204

Nieuwegein …………

2
Service manual 1-8DPS Global 3/13

Index

1. Spare parts 04

2. Maintenance box 12

Contact

3
Service manual 1-8DPS Global 4/13

1. Spare parts

Fig. 01

4
Service manual 1-8DPS Global 5/13

Fig. 01

Item Part number Description Remarks Qty.


1 B21001 Blasthousing 1
2 004587 Oilite bush 2
3 B21009 Plenum bottom liner 1
4 B21044 Top liner 1
5 979085 Bearing unit 1
6 B21008 Blasthousing cover 1
7 976317 Felt seal 1
8 976310 Hub 1
9 B21637 Tune up kit 6 1/2" 1
10 969780 Side magnet 2
11 969763 Front magnet 1
12 001624 Side brush 2
13 001623 Front brush 1
14 E06437 Adjustable blastwheel cover 1
15 9700120 Cage clamp 1
16 969212 Skid seal 1
17 004573 Skid seal 1
18 971427 Skid retainer 1
19 969580 Side liner LH 1
20 971428 Skid retainer 1
21 969581 Side liner RH 1
22 969217 Rear wheel bar 2
23 E06921 Clamp lever M10 1
24 974963 Wheel 2
25 969586 Liner screw M10x25 2

5
Service manual 1-8DPS Global 6/13

Fig. 02

6
Service manual 1-8DPS Global 7/13

Fig. 02

Item Part number Description Remarks Qty.


1 E06434 Dust cover All types 1
E03034 3 kW motor 1-8DPS30 1
2 E06360 5.5 kW motor 1-8DPS55 1
E06118 7.5 kW motor 1-8DPS75 1
1-8DPS55 &
E06387 Belt guard 1
3 1-8DPS75
E06939 Belt guard 1-8DPS30 1
4 E06392 Hose clamp All types 1
1-8DPS55 &
E06394 Fill up plate blast motor 1
5 1-8DPS75
E03028 Fill up plate blast motor 1-8DPS30 1
1-8DPS55 &
E06398 Motor bracket 1
6 1-8DPS75
E06399 Motor bracket 1-8DPS30 1
1-8DPS55 &
E10415 Taper lock 1
7 1-8DPS75
E06937 Taper lock 1-8DPS30 1
8 E06160 Pulley All types 1
All types
E03518 Taper lock 1
50 Hz
9
All types
E00629 Taper lock 1
60 Hz
All types
976659 Pulley 1
50 Hz
10
All types
E00620 Pulley 1
60 Hz
1-8DPS55 &
E06131 V-belt 1-8DPS75 2
50 Hz
1-8DPS55 &
11
E06182 V-belt 1-8DPS75 2
60 Hz
1-8DPS30-
E06938 V-belt 2
50 & 60Hz
12 500-1195 Rubber latch assy All types 1

7
Service manual 1-8DPS Global 8/13

Fig. 03

8
Service manual 1-8DPS Global 9/13

Fig. 03

Item Part number Description Remarks Qty.


1 E03024 Drive motor bracket 1
2 E03026 Drive motor 1
3 979076 Drive motor sprocket 1
4 979067 Chain guard 1
5 969409 Drive wheel 1
6 979077 Drive sprocket 1
7 976818 Bearing 2
8 Washer 1
9 971621 Drive shaft 1
10 970015 Drive plate 1
11 976323 Cover for drive pin 1
12 E03035 Drive shaft 1
13 E00237 Chain 1/2" ISO 0.56M
14 478198 Quick release pin 1
15 970016 Wheel plate 1
16 E06403 Handle top part 1
17 E00867 switch 2
18 E00866 Potentiometer 1
19 E00743 Switch lever 1
20 976817 Sleeve bearing bush 2
21 970108 Swivel pin 1
22 453290 Soft grip Ø25 1
23 454796 Limit switch 1
24 979087 Sleeve bearing bush 1
25 E06405 Handle stem 1
26 E00740 Control box 1
27 E00741 Control box top plate 1

9
Service manual 1-8DPS Global 10/13

Fig. 04

10
Service manual 1-8DPS Global 11/13

Fig. 04

Item Part number Description Remarks Qty.


1 B21003 Deflector 1
2 E06595 Separator tray 1
1-8DPS30
3 967577 Feed spout & 1
1-8DPS55
E06142/ Electro box complete
1-8DPS30 1
1-8DPS30 1-8DPS30
1-8DPS30
E01535 Elektro box special 220V/SF 220V/SF 1
4 50/60Hz
E06142/ Electro box complete
1-8DPS55 1
1-8DPS55 1-8DPS55
E06142/ Electro box complete
1-8DPS75 1
1-8DPS75 1-8DPS75
5 E00368 Cable guide- end 2
6 DG39 Pipe clamp Ø25 2
7 DG41 Cable tube 1
8 E06418 Separator basic 1
Logo Blastrac with mounting
9 E06436 1
strip
10 E06419 Separator lid 1
11 E06531 Locking lever 1
12 E06912 Adapter plate elektro box 1
13 B21021 Control cable bracket 1
14 03600001 Clamp/Toggle 1-8DPS30 1
15 973322 Magnetic valve 1-8DPS75 1
16 970385 Handle 1
17 B21035 Adapter magnetic valve 1-8DPS75 1
18 491726-1 Nipple & screw 1
19 959647 Valve lever 1
20 975100 Control cable 1
21 971500 Feed spout seal ring 1
1-8DPS30
22 969819 Magnetic valve & 1
1-8DPS55

11
Service manual 1-8DPS Global 12/13

3. Maintenance box

Maintenance box 1-8DPS55 50Hz / 1-8DPS75 50Hz : E07005


Maintenance box 1-8DPS55 60Hz / 1-8DPS75 60Hz: E07006
Maintenance box 1-8DPS30 50Hz & 60Hz: E07007

Item Maintenance box 1-8DPS55/75 50Hz E07005 Qty.


1 E06131 V-belt 2
Maintenance box 1-8DPS55/75 50Hz
See list below
4 - 25
Remarks

Item Maintenance box 1-8DPS55/75 60Hz E07006 Qty.


1 E06182 V-belt 2
Maintenance box 1-8DPS55/75 50Hz
See list below
4 - 25
Remarks

Item Maintenance box 1-8DPS30 50/60Hz E07007 Qty.


1 E06938 V-belt 2
Maintenance box 1-8DPS55/75 50Hz
See list below
4 - 25
Remarks

Item Part number Description Remarks Qty.


4 001030 Metal box
5 969580 Left liner
6 969581 Right liner
7 B21044 Top liner
8 B21637 Tune-up kit 6“
9 975100 Abrasive control cable
10 004573 Rear seal rubber
11 969212 Skid seal
12 001624 Side brush 2
13 001623 Front brush 1
14 001017 Open-end spanner 10/11
15 001040 Open-end spanner 13/17
16 001019 Open-end spanner 17/19
17 000144 Ratchet spanner 1/2"
18 000145 Box spanner 8mm
19 000146 Box spanner 13mm
20 001043 Box spanner 17 mm
21 001032 Screwdriver 5,5 x 100
22 001035 Insulated screwdriver
23 001056 Water pump pliers
24 001000 Hammer
25 001031 Safety glasses

12
0 1 2 3 4 5 6 7 8 9

Blastrac
Utrechthaven 12
bv
3433 PN Nieuwegein
Netherlands
+31(0)30-6018866
+31(0)30-6018333

Project description 1-8DPS30 3KW 230V SF MKII ULCSA

Drawing number PJ11.01067.10


Blastrac number E01535-1/ULCSA
Power supply 230VAC 1ph 60Hz
Input lead
Control Voltage 230VAC 60Hz

Year of Manufacturing 2010

Remarks As built

Note: Production check Parts for Aproval Label

Created on by hvandenbrink
Edit date 16-9-2015 by KR Number of pages 16

2
Date 2-1-2012 Project name: Page description: Customer: =
Ed. HVDB 1-8DPS30 3KW 230V SF ULCSA Blastrac BV +
Titelblad / voorblad
Modification Date Name
Appr
Last print 16-9-2015
E01535-1/ULCSA Drawing number:
PJ11.01067.10 Page
1
© ART4 Technical Systems, Soest NL
0 1 2 3 4 5 6 7 8 9

Table of contents
Page Page description Revision Date Edited by
1 Titelblad / voorblad 2-1-2012 HVDB
2 Table of contents 16-9-2015 HVDB
2.a Revision sheet 30-6-2014 PH
3 Legend 6-5-2011
4 Symbol library 25-2-2011
5 Panel layout 30-6-2014 PH
5a Panel layout dimensions 15-10-2012
5b Mountingplate dimensions 25-2-2011
6 Cableset 26-7-2013
10 Main Current 30-6-2014 PH
11 Control current 17-7-2014 HVDB
20 Terminal diagram 2-1-2012 HVDB
21 Terminal diagram 2-1-2012 HVDB
22 Terminal diagram 16-9-2015 KR
30 Part list 16-9-2015 KR
31 Part list 16-9-2015 KR

1 2.a
Date 16-9-2015 Project name: Page description: Customer: =
Ed. KR 1-8DPS30 3KW 230V SF ULCSA Blastrac BV +
Table of contents
Modification Date Name
Appr
Last print 16-9-2015
E01535-1/ULCSA Drawing number:
PJ11.01067.10 Page
2
© ART4 Technical Systems, Soest NL
0 1 2 3 4 5 6 7 8 9

Revision Date Discription Remark Editor

01 19-05-2011 Cable gland added for eart connection to frame Engineering Art4 HvdB

02 28-09-2011 Wire bridge drawn in frequency drive on page 10 Engineering Art4 HvdB

03 14-12-2011 Update cable gland discription Engineering Art4 HvdB

04 02-01-2012 CSA logo added Engineering Art4 HvdB

05 18-07-2012 Settings freqency drive changed (E2-01, H4-02 and L3-06) Engineering Art4 acc. remarks Blastrac and new motor HvdB

06 17-08-2012 Remark added for production acc CSA surveyor remark Engeneering ART4 HvdB

07 15-10-2012 page 5a cable glands changed, page 6 m16A changed to M20 Engeneering ART4 HvdB

08 02-05-2013 Partlist updated Engeneering ART4 HvdB

09 30-06-2014 Partlist updated Engeneering ART4 PH

10 16-09-2015 Update partlist Engineering ART4 KR

2 3
Date 16-9-2015 Project name: Page description: Customer: =
Ed. KR 1-8DPS30 3KW 230V SF ULCSA Blastrac BV +
Revision sheet
Modification Date Name
Appr
Last print 16-9-2015
E01535-1/ULCSA Drawing number:
PJ11.01067.10 Page
2.a
© ART4 Technical Systems, Soest NL
0 1 2 3 4 5 6 7 8 9

WIRE COLOR SYMBOL CODE

Main Voltage (200-230Vac) 11 F 11

Phase Colors - Running number


L - Black - Symbol letter
N - White - Schedule page
Earth / PE - Yellow/Green

CORE CODE
Control Voltage
11 11
Phase (230VAC) -Black
Hook-up wire - Black - Running number
Neutral (230VAC) - white

Frequency inverter and Varispeed V7

Hook-up wire - dark blue

DRAWING NUMBER

PJ##.####.##
AWG - Metric
AWG 12 - 4.0mm² - Revision number
AWG 14 - 2.5mm² - Archive number
AWG 18 - 1.0mm²
AWG 22 - 0.5mm² - Year

2.a 4
Date 6-5-2011 Project name: Page description: Customer: =
Ed. 1-8DPS30 3KW 230V SF ULCSA Blastrac BV +
Legend
Modification Date Name
Appr
Last print 16-9-2015
E01535-1/ULCSA Drawing number:
PJ11.01067.10 Page
3
© ART4 Technical Systems, Soest NL
0 1 2 3 4 5 6 7 8 9

auxiliary contact hulpcontact signal light signaallamp Safety fuse smeltveiligheid

Power contact vermogenscontact horn hoorn

Fused switch, three-pole schakelbare scheider


NO contact, maakcontact,
opens with time delay vertraagd open
A apm.meter amperemeter

Fused disconnect, three-pole scheider "klapbak"


NO contact, maakcontact,
closes with time delay vertraagd sluitend runninghour
h counter urenteller
Main switch hoofdschakelaar
NC contact, verbreekcontact,
opens with time delay vertraagd open

Circuit breaker, single-pole installatieautomaat 1-polig


NC contact, verbreekcontact, transformer transformator
closes with time delay vertraagd sluitend

Circuit breaker, two-pole installatieautomaat 2-polig


Pushbotton drukknop
Contactor coil
rebound terugverend relay coil spoel

Circuit breaker, three-pole installatieautomaat 3-polig


Pushbotton drukknop
Contactor/relay coil, Spoel met
locking blijvend with pick-up delay opkomvertraging

Power circuit breaker


Rotary switch Contactor/relay coil, spoel met
motor overload switch
rebound tip draaischakelaar with drop-out delay afvalvertraging
I> I> I> with switch mechanism motorbeveiligingsschakelaar

Rotary switch Contactor pulse coil


locking draaischakelaar relay pulse coil, spoel puls Valve elektrisch bediende klep

Emergency stop noodstop met


rotary unlock draaibare vrijgave Resistor with movable contact regelbare weerstand
Tube light TL verlichting

thermostaat Terminal rijgklem


Thermostatic switch hygrostaat
weerstand
Resistor / Heating verwarming Terminal with fuse rijgklem met zekering

P P
Pressure switch drukschakelaar

Socket wandcontactdoos -
˜
+
˜
Rectifier gelijkrichter
Limit switch eindschakelaar

Current transformer stroomtransformator

Proximity switch naderingsschakelaar

3 5
Date 25-2-2011 Project name: Page description: Customer: =
Ed. 1-8DPS30 3KW 230V SF ULCSA Blastrac BV +
Symbol library
Modification Date Name
Appr
Last print 16-9-2015
E01535-1/ULCSA Drawing number:
PJ11.01067.10 Page
4
© ART4 Technical Systems, Soest NL
0 1 2 3 4 5 6 7 8 9

FRONT VIEW
MOUNTING PLATE
CAB

STEERING-UNIT

10F3 10F8

11K3 11U5
Speed control
Overdrive FWD./REV.
10P5 11SH2 11S1

11S7 11S8
11R6

11S6

10S1
10U3

10S1

X0-X1-X2

4 5a
Date 30-6-2014 Project name: Page description: Customer: =
Ed. PH 1-8DPS30 3KW 230V SF ULCSA Blastrac BV +
Panel layout
Modification Date Name
Appr
Last print 16-9-2015
E01535-1/ULCSA Drawing number:
PJ11.01067.10 Page
5
© ART4 Technical Systems, Soest NL
0 1 2 3 4 5 6 7 8 9

TOP VIEW

15 15
2xØ6.5

18
297

LEFT-HAND VIEW FRONT VIEW RIGHT-HAND VIEW REAR VIEW


FAN side 210 300

68.5
75 75

Dimensions form doorside


45 Ø22.5 Ø22.5

45

Both holes must be pluged


72
4xØ4.5
72

397

400
4xØ4.5

Dimension form doorside


72

88.5
Ø7

4xØ5.5

72
8

Ø7
180

8
Ø13 Ø13.5 Ø13.5
48

2x Blind rivet M10x17


120
55
Dimension form doorside
170

48

155
123.5

120
BOTTOM VIEW

UNIONPLATE
A= SUPPLY
B= STEERING UNIT
C= EARTH
D= BLASTMOTOR
E= DRIVE MOTOR
75 35

40
Ø25.5
Ø16.5 Ø20
A C B
Ø25.5 2xØ20.5

D E
70
40

0
0

Ø1
Ø1

Ø1
10

Ø1

0
0

60
70 70
95
95 110 95

5 5b
Date 15-10-2012 Project name: Page description: Customer: =
Ed. 1-8DPS30 3KW 230V SF ULCSA Blastrac BV +
Panel layout dimensions
Modification Date Name
Appr
Last print 16-9-2015
E01535-1/ULCSA Drawing number:
PJ11.01067.10 Page
5a
© ART4 Technical Systems, Soest NL
0 1 2 3 4 5 6 7 8 9

MOUNTING PLATE
250
25 50 35 83 38

18
38

60

111
73

75
68

370
158
80

35
118 15

All tapped holes M4

5a 6
Date 25-2-2011 Project name: Page description: Customer: =
Ed. 1-8DPS30 3KW 230V SF ULCSA Blastrac BV +
Mountingplate dimensions
Modification Date Name
Appr
Last print 16-9-2015
E01535-1/ULCSA Drawing number:
PJ11.01067.10 Page
5b
© ART4 Technical Systems, Soest NL
0 1 2 3 4 5 6 7 8 9

Kastzijde Motorzijde
Blastmotor (total length 130cm)
150 1050 100

U1
(X1:1)
U
(X1:2) V Neopreen 4x AWG 14 V1 Blue M5
(X1:3)
W
(X1:PE)
PE W1
Wire ferrules
1300 PE

Wheelmotor (total length 75cm)


150 500 100

U1
(X1:4)
U
(X1:5) Neopreen 4x AWG 16 V1
V Red M5
(X1:6)
W
(X1:PE) W1
PE
Wire ferrules
750 PE

Steering-unit (total length 143cm)


Unitzijde
150 280 1000

115 35 50 950

Mantel 3x awg22 afgeschermd Wire ferrules POTMETER


LEFT
Brown Brown Rear
MID
Green Green view
White White RIGHT
X2:4
71
X2:5
73
X2:6
75
X2:7
76
4x AWG 18 dark Blue
Wire ferrules
Slang SP16
Wartel SP16-M20A Wartel SP16-M16B
1430

5b 10
Date 26-7-2013 Project name: Page description: Customer: =
Ed. 1-8DPS30 3KW 230V SF ULCSA Blastrac BV +
Cableset
Modification Date Name
Appr
Last print 16-9-2015
E01535-1/ULCSA Drawing number:
PJ11.01067.10 Page
6
© ART4 Technical Systems, Soest NL
0 1 2 3 4 5 6 7 8 9

1
BK
AWG12
4
WH
AWG12

1 4
BK WH
AWG10 AWG10

1 3 1 3 1 3
15
10S1 10F3 DBU 10F8
AWG22
63A 2 4 D32A 2 4 UL 2 4
C10A
x1

10P5 A
10/20A
9 12 16
10V/25A x2 21 22
BK WH DBU BK WH
AWG10 AWG10 15 AWG22 AWG14 AWG14
18
DBU
AWG22

16 20 Par. settings V1000 inverter Omron


DBU
18 AWG22 Bridge V+ and A1 for max. speed setting
20

A1-01-2 Advanced acces


2
BK
10U3 12 14 b1-02-1 Terminal control
AWG10 Omron L N AM+ AC- SC S1
5 V1000
11K3 b1-03-1 Coast to stop
WH
AWG10
11.3 11 C1-01-3 Second L N
E1-04-50 Hertz 11.0 11.0
U V W HC H1 H2 PE V+ E1-05-230 Vac
A1
E2-01-10,3 Amp
19 H2-01-2 Speedagree
13
BK GN/YL H4-01-103 Output current
10 11 AWG14 AWG14
H4-02 73,5 gain %
H4-03 0 bias %
PE PE PE L3-01-1 General current limit
L3-05-1 Load Limit
L3-06-59 59% current limit during run
L3-02-65 65% current limit during acc
X0 L N PE X1 1 2 3 PE
(AWG14)
10 AWG 2,5mm²

L N PE U1 V1 W1 PE
Earth connection
to Frame
10M3
M
3

Blast motor
Supply 4Hp/230V/11.8A Control Voltage
230V 1ph 60Hz Connection in Delta 230V 1ph 60Hz

MC MA 11.4

6 11
Date 30-6-2014 Project name: Page description: Customer: =
Ed. PH 1-8DPS30 3KW 230V SF ULCSA Blastrac BV +
Main Current
Modification Date Name
Appr
Last print 16-9-2015
E01535-1/ULCSA Drawing number:
PJ11.01067.10 Page
10
© ART4 Technical Systems, Soest NL
0 1 2 3 4 5 6 7 8 9

21 25
BK BK
10.8 / L
AWG14 AWG14 POTMETER
25 25 25 26
BK BK WH
AWG18 AWG18 AWG14
Rear
1 3 22 24
71 71 view
11S1 11SH2 11K3 11R6
11.1 2 11.2 4 11.3 21
27 10K/4W
Emergency stop 11.4 27
BK
Wt Brown White

Brown
AWG18 71

Green
White
start
3 3 3
Green

1 11S6 4 11S7 4 11S8 4


11SH2 Travel Overdrive FWD/REV
73 75 76
11.2 2
stop

X2 PE X2 1 2 3
39
4 5 6 7
76
DBU DBU
PE 37 38 AWG22 71 73 75 AWG22 Par. setting
PE C37 = 50
33

11U5
ESMD 251 L1 L2/N PE 7 8 9 20 28 E1 E2
28
BK
AWG18
U V W

28
BK
AWG18 28

34
BK
31 32 AWG14
MC

26
10U3
BK 10.3 MA
26 AWG18
30
BK
26 26 AWG18
PE
PE
1 2
1 A1 x1
11S1 11M2
M 11K3 11SH2 X1 4 5 6 PE
11.1 2 230V 1~ A2 11.2 x2
Emergency stop PE WT
230V AWG16
26 26
WH WH
22 26 AWG18 AWG18
WH WH U1 V1 W1 PE
AWG14 AWG14
10.8 / N
11M5
M
3

FAN Motor Motor Drive motor Controls


running running 0.3Hp/230VAC/1.6A Steering-unit
Connect as Delta
A1 A2
14 11
12
24 21
22
14 11 10.5
12
24 21 11.3
22

10 20
Date 17-7-2014 Project name: Page description: Customer: =
Ed. HVDB 1-8DPS30 3KW 230V SF ULCSA Blastrac BV +
Control current
Modification Date Name
Appr
Last print 16-9-2015
E01535-1/ULCSA Drawing number:
PJ11.01067.10 Page
11
© ART4 Technical Systems, Soest NL
0 1 2 3 4 5 6 7 8 9

Terminal diagram F13_001

Strip

Cable name

Cable name
X0
Terminals Power Supply

Connection

Connection
cable type

cable type
terminal

jumper
point

point
function text Target designation Target designation Page / column

Supply 230V 1ph 60Hz 10S1 2 L L 10.1


= 10S1 4 N N 10.1
= PE PE PE 10.1

11 21
Date 2-1-2012 Project name: Page description: Customer: =
Ed. HVDB 1-8DPS30 3KW 230V SF ULCSA Blastrac BV +
Terminal diagram
Modification Date Name
Appr
Last print 16-9-2015
E01535-1/ULCSA Drawing number:
PJ11.01067.10 Page
20
© ART4 Technical Systems, Soest NL
0 1 2 3 4 5 6 7 8 9

Terminal diagram F13_001

Strip

Cable name

Cable name
X1
Terminals Blast- and wheelmotor

Connection

Connection
cable type

cable type
terminal

jumper
point

point
function text Target designation Target designation Page / column

Blast motor 4Hp/230V/11.8A Connection in Delta 10U3 U 1 10M3 U1 10.3


= 10U3 V 2 10M3 V1 10.3
= 10U3 W 3 10M3 W1 10.3
= PE PE 10M3 PE 10.3
Drive motor 0.3Hp/230VAC/1.6A Connect as Delta 11U5 U 4 11M5 U1 11.5
= 11U5 V 5 11M5 V1 11.5
= 11U5 W 6 11M5 W1 11.5
= PE PE 11M5 PE 11.5

20 22
Date 2-1-2012 Project name: Page description: Customer: =
Ed. HVDB 1-8DPS30 3KW 230V SF ULCSA Blastrac BV +
Terminal diagram
Modification Date Name
Appr
Last print 16-9-2015
E01535-1/ULCSA Drawing number:
PJ11.01067.10 Page
21
© ART4 Technical Systems, Soest NL
0 1 2 3 4 5 6 7 8 9

Terminal diagram F13_001

Strip

Cable name

Cable name
X2
Terminals Steering-unit

Connection

Connection
cable type

cable type
terminal

jumper
point

point
function text Target designation Target designation Page / column

Speed 11U5 7 1 11R6 11.6


= 11U5 8 2 11R6 11.6
= 11U5 9 3 11R6 11.6
Supply 11U5 20 4 11S6 3 11.7
Travel switch 11U5 28 5 11S6 4 11.7
Overdrive 11U5 E1 6 11S7 4 11.8
FWD/REV 11U5 E2 7 11S8 4 11.8
Speed control shield PE PE 11.6

21 30
Date 16-9-2015 Project name: Page description: Customer: =
Ed. KR 1-8DPS30 3KW 230V SF ULCSA Blastrac BV +
Terminal diagram
Modification Date Name
Appr
Last print 16-9-2015
E01535-1/ULCSA Drawing number:
PJ11.01067.10 Page
22
© ART4 Technical Systems, Soest NL
0 1 2 3 4 5 6 7 8 9

Parts list
device tag Quantity designation Type number Brand Blastrac number

CAB 1 Wall mount encl 400x300x210MM IP66 MAS 0403021SPECIAL Eldon E05174
CAB 1 Cable gland M20*1.5 polyamide 50.620 WARTEL PA M20*1.5 Jacob E07887
CAB 2 Cable gland M25*1.5 polyamide 50.625 WARTEL PA M25*1.5 Jacob E07978
CAB 2 Cable gland nut M20*1.5 polyamide 50.220PA WARTELMOER PA M20 Jacob E07889
CAB 2 Cable gland nut M25*1.5 polyamide 50.225PA WARTELMOER PA M25 Jacob E07979
CAB 1 FITTING @16*M20 SP16/M20/A Adaptaflex E07839
CAB 1 FITTING @16*M16 DRAAIBAAR SP16/M16/B Adaptaflex E05178
CAB 1 Cable gland nut M16*1.5 brass, nickel-plated WARTELMOER M16*1.5 Jacob E00405_1
CAB 2 Blindklinkmoer M10 POPBC-1Z-M10X17 CK16 Generic E05180
CAB 1 overdrive-forward zelfkl.60*10 witte pl/zw letter RESOPAL 2-20DT/1 Generic E07836
CAB 1 speed control zelfkl.45*10 witte pl/zw letter RESOPAL 2-20DT/2 Generic E07837
CAB 1 Cable gland nut M20*1.5 brass, nickel-plated WARTELMOER M20*1.5 Jacob E00406_1
CAB 1 zelfkl.:BLASTWHEEL MAX 11A RESOPAL 60*14 ZP/WL 1 Generic E07980
CAB 1 Spiraalsl. wit 15-80MM P4 per mtr. SPIRAALSLANG 15-80MM Generic E07901
CAB 1 Mount.drain BxH 25x60 MM vpp=60 T1-E 25X60 MOUNT.DRAIN Generic E07972
CAB 1 M.rail galvanized,7,5x35MM 2M TS35 MOUNT.RAIL GROOVE Generic E07835
CAB 20 Mont. bundelb. 98*2,5mm. wit a 100st. T-18R N 100 WIT E07981
CAB 2 Stuurstroomkabel pvc 3*0.35 UL/CSA 3X AWG22/7 E10733
CAB 7 Internal wire blue AWG12 4mm2 UL-CSA AWG 12 BLAUW LAPP E08026
CAB 7 Internal wire black AWG12 4mm2 UL-CSA AWG 12 ZW LAPP E08110
CAB 1 Internal wire yellow/green AWG14 2.5mm2 UL-CSA AWG 14 GE/GN LAPP E07974
CAB 4 Internal wire black AWG14 2.5mm2 UL-CSA AWG 14 ZWART LAPP E07843
CAB 5 Internal wire black AWG18 1.0mm2 UL-CSA AWG 18 ZWART LAPP E07845
CAB 16 Internal wire darkblue AWG22 0.5mm2 UL-CSA AWG 22 D BL. LAPP E08012
CAB 50 Ferrule 0.5mm2 white insulated G 488 MONT.ADERHULS Calpe E07848
CAB 50 Ferrule 1mm2 red insulated G 490 Calpe E07849
CAB 25 Ferrule 2x1mm2 red insulated G 490-TWIN MONT.A.H. Calpe E07850
CAB 5 Ferrule 1,5mm2 black insulated G 491 MONT.A.H. Calpe E07851
CAB 50 Ferrule 2,5mm2 grey insulated G 492 MONT.ADERHULS Calpe E07852
CAB 25 Ferrule 4mm2 orange insulated G 493 MONT.AD.HULS Calpe E07854
CAB 10 Ferrule 2x4mm2 grey insulated G 493 TWIN MONT.AD.HULS Calpe E07897
CAB 4 Ferrule fork M5 0.5-6.0 mm2 blue A-25053 Calpe E07982
CAB 4 Cabletag eye M5 1,04..2,63 mm2 blue A-2553 R MONT.K.SN. Calpe E07983
CAB 3 Internal wire white AWG10 6mm2 UL-CSA AWG 10 WIT LAPP
CAB 3 Internal wire black AWG10 6mm2 UL-CSA AWG 10 ZW LAPP E07891
CAB 3 Internal wire blue AWG14 2.5mm2 UL-CSA AWG 14 BLAUW LAPP E08028
CAB 2 Internal wire white AWG18 1.0mm2 UL-CSA AWG 18 WI LAPP E07844
CAB 1 UL neopreen 4*AWG16 (1.5mm2) 600V. AWG 16*4 LAPP E10796
CAB 1 Cable gland M16*1.5 polyamide 50.616 WARTEL PA M16*1.5 Jacob E01196
CAB 1 Cable gland nut M16*1.5 polyamide 50.216PA WARTELMOER PA M16 Jacob E07890
CAB 3 Internal wire white AWG14 2.5mm2 UL-CSA AWG 14 WIT LAPP E08112
CAB 1 Internal wire white AWG12 4mm2 UL-CSA AWG 12 WIT LAPP
CAB 2 UL neopreen 4*AWG14 (2.5mm2) 600V. AWG 14*4
10S1 1 Body 3p main switch 63A V3 Schneider Electric 333-3486.01
10S1 1 Rotary handle front KCF - for V3, V4 - red handle KCF-2PZ Schneider Electric 333-3486.02
10U3 1 Freq. regelaar monophase 200/240Vac 4kW ex filter Yaskawa FREQ V1000 Omron E07985
10F3 1 Circuit breaker AB 2P 32A D-kar UL489 C60N-1489-M2D320 Allen Bradley E07984
10P5 1 Amperemeter schaal 25A/ in10Vdc 48*48 met cornermask IQ/EQ48 25A/10V Crompton E01635
10F8 1 Circuit breaker AB 2P 10A C-kar UL 489 480/277V C60N-1489-M2C100 Allen Bradley E05181
11S1 1 Red Ø40 Emergency switching off pushbutton head Ø22 latching ZB4-BS844 Schneider Electric E08437
11S1 1 Body for control button - Ø 22 - 2NC ZB4-BZ104 Schneider Electric E01333
11S1 1 Sticker emergency stop yellow/red EMERGENCY STOP STICKER De Vries E07832
11M2 2 UITL.FILT.MONT.UITSP. 80*80MM 221-336 KAST KL.BEH. PABST E00283
11M2 2 Finger Guard 80mm. 250-1612 KAST KL.BEH PABST E00283
11M2 1 VENTILATOR80*80*38MM 240VAC FAN 80*80*38 PABST E05140
11SH2 1 Green flush/red flush illuminated double-headed pushbutton Ø ZB5-AW7A3741 Schneider Electric E07804

22 31
Date 16-9-2015 Project name: Page description: Customer: =
Ed. KR 1-8DPS30 3KW 230V SF ULCSA Blastrac BV +
Part list
Modification Date Name
Appr
Last print 16-9-2015
E01535-1/ULCSA Drawing number:
PJ11.01067.10 Page
30
© ART4 Technical Systems, Soest NL
0 1 2 3 4 5 6 7 8 9

Parts list
device tag Quantity designation Type number Brand Blastrac number

11SH2 1 White light block with body/fixing collar integral LED 230.2 ZB5-AVM1 Schneider Electric E05093
11SH2 1 Single contact block for head Ø22 1NO screw clamp terminal ZBE-101 Schneider Electric E05091
11SH2 1 Single contact block for head Ø22 1NC screw clamp terminal ZBE-102 Schneider Electric E05092
11SH2 1 Transparent boot for rectangular multiple-headed pushbutton ZBA-710 Schneider Electric E05070
11K3 1 Relay interf. 2W 230AC with indication OMRON G2R-2-SNI 230AC Omron E05086
11K3 1 Screwless clamp terminal socket for G2R-2 OMRON P2RF-08-S Omron E07986
11K3 1 Clip for socket P2RF-08S OMRON P2CM-S Omron E05188
11U5 1 ESMD251X2SFA basic 0.25 kW FREQ.REG 0.25 KW BAS Lenze E00281
11R6 1 Potm. 10KOhm. 4W-500V POTMETER 10 K OHM Generic 454795
11R6 1 Head Ø22 + mounting base for potentiometer ZB5-AD912 Schneider Electric E01351/1
11R6 2 Black round blanking plug for Ø22 hole ZB5-SZ3 Schneider Electric E05182
11R6 1 Schroef aansluiting potmeter POTMETER PRINT KLEM Wieland E05088
11S6 1 Limit switch XCKP - steel roller plunger - 1NO+1NC - snap - XCK-P2102P16 Schneider Electric 454796
11S7 1 White square flush complete pushbutton Ø16 spring return 1NO XB6-CA11B Schneider Electric E00867
11S8 1 White square flush complete pushbutton Ø16 spring return 1NO XB6-CA11B Schneider Electric E00867
X0 2 Conn. railkl. 10MM2 grijs VU5-10 GRIJS Wieland 350-3554-EDA
X0 1 Conn.aardkl.,10MM2, geel/groen VUPE WKN 10SL/U Wieland E05192
X0 1 Eindschot voor VU5-10 APN 10
X1 6 Conn. railkl. 4MM2 grijs WK4/U VU4-4 GRIJS CONN.R.K Wieland E07829
X1 2 Aardkl. 4MM2 ge/gr WK4SL/u VUPE 4-4 CONN.AARDKL Wieland E01197
X2 1 End plate Beige for ZDK 2.5 multi level WEID ZAP/TW ZDK2.5 DB Weidmuller E05171
X2 4 tension clamp terminal multi level 2*2.5 WEID ZDK 2.5 Weidmuller E05169
X2 1 earth terminal for ZDK 2*2.5 WEID ZDK 2.5PE Weidmuller E05170
X2 2 End bracket for weidmuller terminals WEID ZEW 35 Weidmuller E05177

30
Date 16-9-2015 Project name: Page description: Customer: =
Ed. KR 1-8DPS30 3KW 230V SF ULCSA Blastrac BV +
Part list
Modification Date Name
Appr
Last print 16-9-2015
E01535-1/ULCSA Drawing number:
PJ11.01067.10 Page
31
© ART4 Technical Systems, Soest NL
Certificate of Compliance
Certificate: 2459264 Master Contract: 251963

Project: 2459264 Date Issued: December 1, 2011

Issued to: ART4 Technical Systems B.V.


Nieuwe gracht 11
3763 LP Soest
THE NETHERLANDS

The products listed below are eligible to bear the CSA Mark shown
with adjacent indicators 'C' and 'US' for Canada and US or with adjacent
indicator 'US' for US only or without either indicator for Canada only

Issued by: G. Vertechy


G. Vertechy

PRODUCTS

CLASS 3211 07 INDUSTRIAL CONTROL EQUIPMENT – Miscellaneous Apparatus


CLASS 3211 87 INDUSTRIAL CONTROL EQUIPMENT – Miscellaneous Apparatus –
Certified to US Standards

Motor control box, enclosure Type 1


Model 350E SB UL, 480Y/277 V, 30 A, 18 Hp, 3-ph, 60 Hz, SCCR 5kA
Model 500E SB UL, 480Y/277 V, 45 A, 29 Hp, 3-ph, 60 Hz, SCCR 5kA
Model BDC 854, 480Y/277 V, 62 A, 40 Hp, 3-ph, 60 Hz, SCCR 5kA
Model 654 BDC, 480Y/277 V, 36 A, 27 Hp, 3-ph or 230 V, 72 A, 27 Hp, 3-ph, 60 Hz, SCCR 5kA
Model 1-10DS Dual Voltage, 480Y/277 V, 19 A, 16 Hp, 3-ph or 230 V, 38 A, 16 Hp, 3-ph, 60 Hz, SCCR 5kA
Model 1-15DS Dual Voltage, 480Y/277 V, 26 A, 21 Hp, 3-ph or 230 V, 52 A, 21 Hp, 3-ph, 60 Hz, SCCR 5kA
Model 1-8 DPS30, 230V, 14 A, 4.3 Hp, 1-ph, 60 Hz, SCCR 5kA
Model 1-10 DPS75, 230V, 29 A, 10.5 Hp, 3-ph , 60 Hz, SCCR 5kA
Model BMC-EHY335, 480Y/277 V, 25 A, 17 Hp, 3-ph, 60 Hz, SCCR 5kA

Note:
- The motor control boxes are factory installed on industral floor treatment equipment. The suitability of
the combination is to be determined by CSA-International or other NRTL.

FF0 002

DQD 507 Rev. 2009-09-01 Page 1


Certificate: 2459264 Master Contract: 251963
Project: 2459264 Date Issued: December 1, 2011

APPLICABLE REQUIREMENTS

CSA Standard C22.2 No. 0 - General Requirements, Canadian Electrical Code Part II
CSA Standard C22.2 No. 04 - Bonding of Electrical Equipment
CSA Standard C22.2 No. 14 - Industrial Control Equipment
UL508 - Industrial Control Equipment
UL508A - Industrial Control Panels

DQD 507 Rev. 2009-09-01 Page 2


Supplement to Certificate of Compliance

Certificate: 2459264 Master Contract: 251963

The products listed, including the latest revision described below,


are eligible to be marked in accordance with the referenced Certificate.

Product Certification History


Project Date Description

2459264 December 1, 2011 Original cCSAus Certification of motor control boxes Types 350E SB UL,
500E SB UL, BDC 854, 654 BDC, 1-10DS dual voltage, 1-15DS dual
voltage, 1-8 DPS30, 1-10 DPS75 and BMC-EHY335.

DQD 507 Rev. 2009-09-01 Page 1


13201 North Santa Fe Avenue  Oklahoma City, OK 73114  Ph: 800-256-3440  F: 405-478-8608 blastrac.com

Product Warranty

Standard Equipment Products:


Blastrac warrants its Blastrac Standard Equipment Products against defects in quality of
material and workmanship, under normal and proper use for a period of 1 Year from the date of
delivery, as noted on the returned warranty registration card, or, in the case of Rental Fleet
Machines, 180 Days from the date of assignment to Rental Fleet. This warranty is non-
transferable and is extended to machines purchased and entered into the normal service of
surface preparation by a recognized professional or qualified contractor. Blastrac makes this
warranty only to the buyer who purchases the products directly from Blastrac or its Authorized
Distributor. This warranty does not include expendable parts such as, but not limited to, blades,
blast wheels, wear plates, liners, seals, and electrical components. All purchased parts utilized
in the manufacture will be honored to the original manufacturer’s specified warranty.

If the buyer does not return the warranty card or register the product online at
www.blastrac.com within 30 days after taking delivery of Blastrac Standard Equipment Products,
the warranty period is limited to 6 months from the date of delivery noted on shipping receipt.

Hand Tool Products:


Blastrac warrants its BLASTRAC Hand Tool Products, including hand grinders and
accessories, against defects in material and workmanship under normal and proper use for a
period of 90 days from the date of delivery or, in the case of Rental Fleet Machines, from the
date of assignment to a Rental Fleet. Blastrac makes this warranty only to the buyer who
purchases the products directly from Blastrac or its authorized distributor. This warranty does
not include expendable parts such as blades.

If the buyer does not return the warranty card, or register online at www.blastrac.com
within 15 days after taking delivery of Blastrac Hand Tool Products, the warranty period is
limited to 30 days from the date of delivery noted on shipping receipt.

WARRANTY TERMS AND CONDITIONS:


1. Blastrac’s obligation under this warranty is limited to the replacement or repair, at
Blastrac’s option, of products and does not include, labor, the cost of transportation, loss
of operating time, or normal maintenance services.

2. This warranty does not apply to failure occurring as a result of abuse, misuse,
negligence, corrosion, erosion, normal wear and tear, alterations or modifications made to
products without the express written consent of Blastrac.

3. The buyer must submit all warranty claims no later than thirty (30) days after buyer
becomes aware of the basis for any such claim, or should have become aware of the basis
for any such claim in the exercise of reasonable diligence.
To return parts for warranty consideration, please call Blastrac Customer Service at
800-256-3440. Your customer service representative will obtain the necessary
information to complete the Blastrac Returned Merchandise Authorization (RMA) Form.
Blastrac will then send the RMA form to the customer authorizing the return of the parts
for warranty evaluation. The parts must be received within sixty (60) days following the
RMA origination date or the warranty claim will be denied. Once the parts are received they
will be evaluated for warranty.

If the customer cannot wait for the evaluation/replacement of the parts during this
process, the customer must issue a new purchase order to Blastrac for the replacement
parts before they can be shipped. Once the evaluation process is complete and parts are
deemed a valid warranty claim, a credit will be issued against this invoice.

4. The buyer may not return Blastrac products without written authorization to do so
through a Blastrac RMA.

5. Blastrac reserves the right to inspect and determine the scope of its warranty
responsibilities for any returned Blastrac products.

6. Blastrac makes no warranty with respect to accessories it does not manufacture,


including but not limited to, engines, motors, batteries, tires and all other parts. See
component manufacture warranty.

7. Blastrac reserves the right to make product changes or improvements without


prior notice and without undertaking any obligation for such changes or improvements on
previously sold products.

8. The above warranty conditions can only be altered by Blastrac. Blastrac must
confirm alterations in writing for each specific transaction.

9. Blastrac reserves the right to modify this warranty for used or demo products on an
individual transaction basis. Blastrac will include warranty modifications on its invoices for
used or demo products.

10. BLASTRAC DOES NOT AUTHORIZE ANY PERSON, REPRESENTATIVE, SERVICE OR


SALES OUTLET TO MAKE ANY WARRANTY DIFFERENT FROM THIS PRODUCT WARRANTY.

11. EXCEPT FOR ITS PRODUCT REPAIR OR REPLACEMENT OBLGATIONS DESCRIBED


IN THIS PRODUCT WARRANTY, UNDER NO CIRCUMSTANCES SHALL BLASTRAC BE LIABLE
TO THE BUYER, OR ANY OTHER PERSON, FOR ANY DIRECT, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OF THE BLASTRAC PRODUCT, OR
FOR ANY SPECIAL OR CONSEQUENTIAL DAMAGES OF ANY CHARACTER, INCLUDING
WITHOUT LIMITATIONS, DAMAGES FOR ANY LOSS OF GOODWILL, WORK STOPPAGE, OR
ANY AND ALL OTHER COMMERCIAL DAMAGES OR LOSSES.

12. BLASTRAC MAKES NO OTHER PRODUCT WARRANTIES, EXPRESS OR IMPLIED,


INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE.

This Product Warranty Effective January 1, 2010.


Warranty Registration Notification
I M P O R TA N T !
TO THE DELIVERING DISTRIBUTOR OR END USER
To ensure the proper warranty coverage is extended to the owner of this machine, fill
in the necessary information below COMPLETELY and ACCURATELY and retain for
your records. Go to www.blastrac.com and register online. Click on the Register icon
in the left column of the homepage, and fill out the product registration form with the
same information that will be recorded here.
The warranty period will start upon the delivery date of the machine.
The distributor or the end user must provide the machine warranty information when
the machine is delivered. Registration of the machine will extend the warranty period
from the recorded delivery date entered with product registration. Failure to comply
will make any and all warranties on the equipment void after 6 months.
OWNER / END USER’S REFERENCE INFORMATION
Delivery Date _________________________ Machine Model No._____________________
Delivering Distributor’s Name and Address Machine Serial No. _____________________
_____________________________________ Modifications__________________________
_____________________________________ _____________________________________
_____________________________________ _____________________________________
_____________________________________ _____________________________________
_____________________________________ _____________________________________
Signature of Delivering Distributor’s Representative

Blastrac is a registered trademark of Blastrac,NA


Fold and Detach Here if Mailing

Warranty Registration
IMPORTANT! To ensure that your Blastrac® machine is covered under warranty, please provide
the information recorded here by registering online at blastrac.com, or complete this page and fax
to 866-485-1046, or if you prefer, detach and mail to:
Blastrac, 13201 North Santa Fe Avenue, Oklahoma City, OK 73114-9901
(Please print legibly)

Company _____________________________________________________________________
Address ______________________________________________________________________
City, State, & Zip _______________________________________________________________
Telephone No._____________________ Contact Person ______________________________
Date of Purchase___________________ Date Received ______________________________
Machine Model No. __________________________ Serial No. _________________________
Distributor Name _______________________________________________________________
End User Name _______________________________________________________________
End User E-mail _______________________________________________________________
Contact
Blastrac NA
13201 North Santa Fe Avenue
Oklahoma City, OK 73114
Tel: 800-256-3440
Fax: 405-478-8608
www.blastrac.com

You might also like