iRIS4 Quick User Guideline Fire Alarm EN-1

The document provides quick guidelines for using an iRIS4 addressable fire alarm panel. It describes what to do in the event of a fire alarm, including starting an evacuation and turning off the buzzer. It also provides instructions for operating the panel in a networked system.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
100 views1 page

iRIS4 Quick User Guideline Fire Alarm EN-1

The document provides quick guidelines for using an iRIS4 addressable fire alarm panel. It describes what to do in the event of a fire alarm, including starting an evacuation and turning off the buzzer. It also provides instructions for operating the panel in a networked system.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

User Quick Guidelines for iRIS4 Addressable Fire Alarm Panel REAL FIRE ALARM, time delay set

REAL FIRE ALARM, time delay set for Sounder, Fire and Fire Protection outputs
Start Evacuation:
FIRE Event in the System Alarm, Zone 1, Loop 1, Loop Device Address 5

FIRE ALARM Indication 1 Tue 13.Jul.2021 09:42:44


36 36 36 34 34 34
Activated Sounders FIRE ALARM Message FIRE alarm in the zones Silence Alarm Silence Buzzer System
13.07. 13.07.
09:43 2021 09:43 2021

1 1
Alarms Alarms
Evacuate, Zone 1, Loop 1, Loop Device Address 7 0 0
Faults Faults
Evacuate RESET
1 Tue 13.Jul.2021 09:42:44
2 0
Warnings Warnings
13.07.
09:42 2021

1 EXIT MENU Access 1 MORE EXIT MENU Access 1 MORE


Alarms

0
Faults

0
Warnings

EXIT MENU Access 1 MORE


In case of Operation in Network, start Evacuation as choose:
1 2 3 4 5 6 7 8 9 10 Select Panel Number 1-64, press an active
11 12 13 14 15 16 17 18 19 20 button for a single panel in the Network,
21 22 23 24 25 26 27 28 29 30 or
FIRE ALARM EVENT, time delay set for Sounder, Fire and Fire Protection outputs 09:43
13.07.
2021
31 32 33 34 35 36 37 38 39 40
Select ALL available panels in the Network,
Turn off the buzzer: 1
Alarms
41 42 43 44 45 46 47 48 49 50
or
51 52 53 54 55 56 57 58 59 60
Alarm, Zone 1, Loop 1, Loop Device Address 5 0 Select only THIS concrete panel.
Faults
61 62 63 64
0
1 Tue 13.Jul.2021 09:42:44 ALL THIS
Warnings
40 40 40 36 36 36 Sounders
09:42
13.07.
2021 09:43
13.07.
2021
Silence Alarm Silence Buzzer System
EXIT MENU Access 1 MORE Active 112
1 1
Alarms Alarms

0 0
Faults Faults
Evacuate RESET
Turn off sounders and Reset:
0 0
Warnings Warnings Evacuate, Zone 1, Loop 1, Loop Device Address 7

EXIT MENU Access 1 MORE EXIT MENU Access 1 MORE


1 Tue 13.Jul.2021 09:42:44 **** 1 2 3

13.07. 13.07.
09:43 2021 09:43 2021 LOG OUT 4 5 6
In case of Operation in Network, turn off the buzzer as choose:
1 1
Alarms Alarms
1 2 3 4 5 6 7 8 9 10 Select Panel Number 1-64, press an active Enter code for 7 8 9
0 0
11 12 13 14 15 16 17 18 19 20 button for a single panel in the Network, Faults Faults access level
0 0 2 or 3. 0 OK
21 22 23 24 25 26 27 28 29 30 Warnings Warnings
13.07. or
09:43 2021
31 32 33 34 35 36 37 38 39 40
EXIT MENU Access 1 MORE EXIT MENU Access 1 MORE

1 41 42 43 44 45 46 47 48 49 50
Alarms Select ALL available panels in the Network,
51 52 53 54 55 56 57 58 59 60
2
Faults
61 62 63 64 or
2
Disable ALL THIS

EXIT MENU Access 1 MORE


Select only THIS concrete panel. Silence Alarm Silence Buzzer System Silence Alarm Silence Buzzer System
13.07. 13.07.
09:43 2021 09:43 2021

1 1
Alarms Alarms

Alarm, Zone 1, Loop 1, Loop Device Address 5


Go to the zone with fire alarm 0 0
event and check for a real Faults
Evacuate RESET
Faults
Evacuate RESET

1 Tue 13.Jul.2021 09:42:44


presence of FIRE, then follow 0
Warnings
0
Warnings
34 34 34 Step 2 - Start Evacuation,
13.07. 13.07. and/or EXIT MENU Access 2 MORE EXIT MENU Access 2 MORE
09:43 2021 09:43 2021
Step 3 - Stop Sounders,
1 1
Alarms Alarms
according the situation. In case of Operation in Network, choose the The panel is reset to Normal operation mode.
panels, where to perform Turn off Sounders. Press Access 2 , then LOG OUT .