Features
• Wide sensitivity range
• Laser based smoke detection
• 4 configurable alarm levels
• High efficiency aspirator
• Four inlet pipes
• Airflow supervisor per sampling pipe
• Dual stage air filter
• Easy to replace air filter
• 7 programmable relays
• VESDAnet™
• AutoLearn™
• Referencing
The LaserPLUS detector is the central element of the VESDA smoke detection
product range. Using unique detection principles, the LaserPLUS has an alarm • Event log
sensitivity range of 0.005%–20% obscuration/m (0.0015%–6.25% obscuration/ft).
• Modular design
The LaserPLUS is classed as a “Very Early Warning Smoke Detector” which means
that it detects fire at the earliest possible stage and reliably measures very low to • Recessed mounting option
extremely high concentrations of smoke.
Listings/Approvals
How It Works
• UL
Air is drawn into the LaserPLUS through a network of air sampling pipes by a high
efficiency aspirator. Each inlet pipe has an airflow sensor that monitors airflow • ULC
changes in the pipes. Air is exhausted from the LaserPLUS and may be vented back • FM
into the protected zone.
• LPC
Inside the LaserPLUS, a sample of air is passed into the laser detection chamber
via a dual-stage air filter. The first filtration stage removes dust and dirt from the air • VdS
sample before entering the laser detection chamber for analysis. The second stage • CCCf
provides ultra fine air filtration to provide very clean air that is used to protect the
optical surfaces inside the detector from contamination. • ActivFire

The detection chamber uses a stable Class 1 laser light source and carefully • AFNOR
positioned sensors to achieve the optimum response to a vast range of smoke types. • CE - EN 54-20
- Class A (30 holes / 0.05% obs/m)
The status of the detector, and all alarm, service and fault events, are transmitted to
displays and external systems via VESDAnet. - Class B (60 holes / 0.06% obs/m)
- Class C (100 holes / 0.08% obs/m)
VESDAnet™ Classification of any configuration is
VESDA detectors and devices communicate across VESDAnet, Xtralis’ fault-tolerant determined using ASPIRE2.
communications protocol. The VESDAnet loop provides a robust bi-directional
communication network between devices, even allowing continued operation during
single point wiring failures. It also allows for system programming from a single
location and forms the basis of the modular nature of the VESDA system.
AutoLearn™
The LaserPLUS technology employs unique software tools to ensure optimum
operation in many differing environments. AutoLearn monitors the ambient
environment and sets the most appropriate alarm thresholds (Alert, Action, Fire1,
Fire2) during the commissioning process to allow the earliest possible warning of
a potential fire situation with no nuisance alarms.
Referencing
Environments that employ air handling systems may be affected by pollution external
to the controlled environment when “fresh air make up” is added. Referencing by
VESDA ensures that external pollution does not interfere with the true smoke level
being detected in the protected environment. The system can safely compensate for
this transient state and allow continued operation free from nuisance alarms.
LaserPLUS TM

Specifications
Detector Mounting Box
Dimensions Supply Voltage: 18–30 VDC
mm in Power Consumption @ 24 VDC:
A 350 13.8 No Display or Programmer
B 225 8.9 Aspirator @ 3000 rpm Aspirator @ 4200 rpm
C 70 2.75 Quiescent With Alarm Quiescent With Alarm
D 57 2.25 Power 5.8 W 6.96 W 8.16 W 9.36 W
E 35 1.37 Current 240 mA 290 mA 340 mA 390 mA
F 44.5 1.75 Dimensions (WHD):
G 22.0 0.87 350 mm x 225 mm x 125 mm (13.8 in x 8.9 in x 4.9 in)
H 14.1 5.56
Weight:
I 15.9 0.62
4.0 kg (9 lbs) including Display and Programmer
J 33.3 1.31
modules
K 34 1.33
L 23.8 0.94
IP Rating: IP30
M 51 2 Operating Conditions:
N 21 0.83 Tested to: -10°C–55°C (14°–131°F)
O 141 5.56 Detector Ambient: 0°C–39°C (32°–103°F)
P 25.4 1 (Recommended)
Q 11.1 0.44 Sampled Air: -20°–60°C (-4°–140°F)
R 9.5 0.37 Humidity: 10%–95% RH, non-condensing
S 28.5 1.12 Please consult your Xtralis office for operation outside
T 30.2 1.19 these parameters or where sampled air is continually
U 3.2 0.125 above 0.05% obs/m (0.015% obs/ft) under normal
operating conditions.
Sampling Network:
Aggregate pipe length: 200 m (650 ft)
Maximum Single Length: 100 m (325 ft)
Pipe Modelling Design Tool: ASPIRE2™
Pipe Size:
Detector Termination Card External Diameter 25 mm (1 in)
Internal Diameter 15–21 mm (9/16 in–7/8 in)
Programmable Relays:
7 Relays, Contacts rated 2 A @ 30 VDC NO/NC
Contacts
Cable Access:
8 x 25 mm (1 in) knockouts in various positions
Cable Termination:
Screw terminals 0.2–2.5 sq mm (30–12 AWG)
Alarm Sensitivity Range:
0.005%–20% obs/m (0.0015%–6.25% obs/ft)
Alarm Threshold Setting Range:
Alert: 0.005%–1.990% obs/m (0.0015%–0.6218% obs/ft)
Action: 0.010%–1.995% obs/m (0.0031%–0.6234%
obs/ft)
Fire 1:0.015%–2.00% obs/m (0.0046%–0.625% obs/ft)
Fire 2:0.020%–20.00% obs/m (0.0062%–6.25% obs/ft)*
*Limited to 12% obs/m (4% obs/ft) in UL mode
Event Log:
Up to 18,000 events stored on FIFO basis.
AutoLearn:
Minimum 15 minutes, maximum 15 days. Recommended
minimum period 1 day. During AutoLearn thresholds are
NOT changed from pre-set values.
Software Features:
Referencing: Compensation for external ambient
conditions Four Alarm Levels: Alert, Action, Fire 1 &
Ordering Information Fire 2
Two Fault Warning Levels: Maintenance and Major fault
Software Programmable Relays: 7
Maintenance Aids: Filter & Flow monitoring.
Event reporting via VESDAnet or Event Log.

Remote Programmer VRT-100


Recessed Mounting Kit (Optional) VSP-011
Hand-held Programmer VHH-1000
19 in Sub Rack Configuration contact Xtralis

www.xtralis.com
The Americas +1 781 740 2223 Asia +852 2297 2438 Australia and New Zealand +61 3 9936 7000
Continental Europe +41 55 285 99 99 UK and the Middle East +44 1442 242 330
The contents of this document are provided on an “as is” basis. No representation or warranty (either express or implied) is made as to the
completeness, accuracy or reliability of the contents of this document. The manufacturer reserves the right to change designs or specifications
without obligation and without further notice. Except as otherwise provided, all warranties, express or implied, including without limitation any
implied warranties of merchantability and fitness for a particular purpose are expressly excluded.
This document includes registered and unregistered trademarks. All trademarks displayed are the trademarks of their respective owners.
Your use of this document does not constitute or create a licence or any other right to use the name and/or trademark and/or label.
This document is subject to copyright owned by Xtralis AG (“Xtralis”). You agree not to copy, communicate to the public, adapt, distribute, transfer,
sell, modify or publish any contents of this document without the express prior written consent of Xtralis.
Doc. no. 09364_09 Part: 18252

You might also like