Call Trace & Network Parameter Collection Procedures
Call Trace & Network Parameter Collection Procedures
Parameter Collection
Procedures
July 2015
Call Trace & Network Parameter Collection Procedures
Collection Procedures
Contents
Collection Procedures
Collection Procedures
The Physical information of each cell that contain CellID, Latitude,Longitude, Antenna Orientation etc, that were
not available inside network dump. The supported format will be in Text Delimited or in our XIF format.
The following header fields are mandatory for parsing xif dump files.
• CellId
• Latitute
• Longitute
• AntDir
Parsing will fail, if one of these mandatory header fields is not found in the dump file.
This file need to be parsed daily to ensure the information drawn on the map and data that will be snyc to Xeus
are accurate.
Sample :
Collection Procedures
Supported file format is an XML file exported from CM Export feature of iManager M2000.
BSC6000NE
BSC6000CellChannel
BSC60002GExtCell
BSC60003GExtCell
BSC6000Cell
BSC6000CellBaseAttr
BSC6000CellCallCtrl
BSC6000CellChMng
BSC6000CellHOCtrl
BSC6000CellPwrCtrl
BSC6000CellSoftPara
BSC6000CellSysMsg
BSC6000CellTimer
BSC60002GAdjRel
BSC60003GAdjRel
BSC6000CellHopData
BSC6000Site
BSC6000TRX
Collection Procedures
<attr name="locationName">Arena</attr>
<attr name="longitude">194.0</attr>
<attr name="matchVersion">iManagerM2000_BSC6000_MATCH_ENG_V200R006C01B624</attr>
<attr name="name">BSCNTB31</attr>
<attr name="neID">2</attr>
<attr name="neType">BSC6000</attr>
<attr name="neVersion">BSC6000V900R008C12</attr>
<attr name="realLatitude">0DN</attr>
<attr name="realLongitude">0DE</attr>
<attr name="vendorName">Huawei</attr>
<MO className="BSC6000BCGrp" fdn=".3221229568.3221233664.3221282818.3221417986">
<attr name="fdn">.3221229568.3221233664.3221282818.3221417986</attr>
<attr name="BSCIndex">0</attr>
<attr name="GrpIndex">0</attr>
<attr name="MOIndex">2_0_0</attr>
<attr name="className">BSC6000BCGrp</attr>
<attr name="name">CBCGrp</attr>
<attr name="neID">2</attr>
</MO>……
Supported file format is the export file from Huawei OSS EXP CFGMML command.
By default, this file is saved in the ftp/export_cfgmml directory of the main area of the OMU and named
CFGMML-RNCX-IP-YYYYMMDDHHMMSS.zip("X" indicates RNC ID).
The folder in located within the RNC. To avoid Xeda having to access the folder, it is best that these Data in the
folder be copied out into a server.
Collection Procedures
ADD GSMCELL
ADD GSMNCELL
ADD NRNC
ADD NRNCCELL
ADD CCP
ADD NCP
ADD NODEB
ADD NODEBALGOPARA
ADD NODEBIP
ADD NODEBLDR
ADD CNOPERATOR
ADD RNCBASIC
SET ADMCTRL
SET AMRC
SET CERRMTIMER
SET CMCF
SET CONNMODETIMER
SET DCCC
SET DPB
SET DRD
SET FACHSCHEPRIO
SET FRMHANDPRIO
SET HCSHO
SET HOCOMM
SET HSDPCC
SET HSDSCHSCHEPRIO
SET HSSCCH
SET IDLEMODETIMER
SET INTERFREQHOCOV
SET INTERFREQHONCOV
SET INTERRATHOCOV
SET INTERRATHONCOV
SET INTRAFREQHO
SET LDCALGOPARA
SET LDM
SET LOCHPRIO
SET OLPC
SET SATLDCPERIOD
SET SRNSR
SET STATETIMER
SET SYS
SET UESTATETRANS
SET WFMRCFGDATA
ACT CELL
ACT CELLHSDPA
ADD CELLACCESSSTRICT
ADD CELLALGOSWITCH
ADD CELLCAC
ADD CELLFRC
ADD CELLHCS
ADD CELLHOCOMM
ADD CELLHSDPA
ADD CELLINTERRATHOCOV
ADD CELLLDB
ADD CELLLDM
ADD CELLLDR
Collection Procedures
ADD CELLMEAS
ADD CELLOLC
ADD CELLPUC
ADD CELLRLACTTIME
ADD CELLSELRESEL
ADD CELLSETUP
ADD CELLSIBSWITCH
ADD CHPWROFFSET
ADD PSINACTTIMER
ADD SMLCCELL
SET PSINACTTIMER
ADD INTERFREQNCELL
ADD INTRAFREQNCELL
Below are the instruction to generate this file in case it is not available in the server :
1. Running the following command to export the MML script file from the configuration data of the OMU
by the default setting.
The script file is exported to "the main area directory of the OMU/ftp/export_cfgmml/CFGMML-RNCX-
IP-YYYYMMDDHHMMSS.zip("X" indicates RNC ID)".
EXP CFGMML:;
2. Running the following command to export the MML script of configuration data on the OMU by the
default export file path.
The script file is exported to /ftp/export_cfgmml on the active workspace of the active OMU and named
"the main area directory of the OMU/ftp/export_cfgmml/cfgmml.zip".
EXP CFGMML: FN="cfgmml.txt";
3. If the OMU runs the WINDOWS system, to export the MML script of configuration data on the OMU
(Export file path = D:\mbsc\bam\version_a\ftp; Export file name = cfgmml.zip), run the following
command(Please affirm that "D:\mbsc\bam\version_a\ftp" is a valid path on the OMU server):
EXP CFGMML: FILEPATH="D:\mbsc\bam\version_a\ftp", FN="cfgmml.txt";
4. If the OMU runs the LINUX system, to export the MML script file from the configuration data of the
OMU (Export file path = /mbsc/bam/version_a/ftp; Export file name = cfgmml.zip), run the following
command (Please affirm that "/mbsc/bam/version_a/ftp" is a valid path on the OMU server):
EXP CFGMML: FILEPATH="/mbsc/bam/version_a/ftp", FN="cfgmml.txt";
Supported file format is an XML configuration file located in the NodeB itself. There is one file per NodeB.
Collection Procedures
<NODEBSOM ID = "0x14000000">
<NODEBTYPE ID = "0x24000001">15</NODEBTYPE>
<NULPFPGA ID = "0x24000002">
<NULPRXDELAYTIME ID = "0x34000003">
<NULPRDT ID = "0x44000004" STATIC = "0" DESC = "Rx time
delay">184</NULPRDT>
</NULPRXDELAYTIME>
</NULPFPGA>
<NULPCDMDDMDSP ID = "0x24000005">
<DEMDSPMODE ID = "0x34000006">
<NBWM ID = "0x44000007" STATIC = "1" DESC = "NodeB work mode(0-
TWOANTENNA 1-FOURANTENNA 3-ECONOMIZED)">0</NBWM>
</DEMDSPMODE>
</NULPCDMDDMDSP>
<NDLPFPGA ID = "0x24000008">
<NDLPUPGBUSMODE ID = "0x34000009">
<UGWM ID = "0x4400000a" STATIC = "0" DESC = "Rx G_Bus work mode(0-
BACKUP 1-STANDALONE)">0</UGWM>
</NDLPUPGBUSMODE>
</NDLPFPGA>
<NDLPENCODEDSP ID = "0x2400000b">
<TXDELAYTIME ID = "0x3400000c">
<TDT ID = "0x4400000d" STATIC = "0" DESC = "Tx time
delay">248</TDT>
</TXDELAYTIME>
</NDLPENCODEDSP>
<BBUCM ID = "0x2400000e" STATIC = "0" DESC = "BBU cascade mode">0</BBUCM>….
The network dump files is inside M2000 server in the following path:
M2000 server : /export/home/sysm/ftproot/NE type (for example: DBS3900)/Data
Example : /export/home/sysm/ftproot/DBS3900/Data
The data generated for automatic backup is located in the AUTOBAKDATA****** directory.
Collection Procedures
Each eNodeB will be having the same file named : NodeBCfg.xml as per screenshot below :
Supported file format is an XML configuration file located in the NodeB itself. There is one file per NodeB.
Collection Procedures
In order to produce the network dump, data need to be backup automatically (periodically).
2.4.1.1 Prerequisites
2.4.1.2 Context
Generally, M2000 dynamic data is backed up periodically. The periodic backup of the dynamic data is performed
in full backup mode.
Dynamic data backup has no restriction on backup time. The backup can be performed during the system
operation.
Note : Backing up dynamic data consumes system resources. Thus, the time set for backup should be at night
when the system traffic is light.
2.4.1.3 Procedure
Collection Procedures
Click Common Parameters, and set Task Name and Start Time.
Collection Procedures
The network dump files is inside M2000 server in the following path:
M2000 server : /export/home/sysm/ftproot/NE type (for example: DBS3900 LTE)/Data
Example : /export/home/sysm/ftproot/DBS3900 LTE/Data
The data generated for automatic backup is located in the AUTOBAKDATA****** directory.
Collection Procedures
Each eNodeB will be having the same file named : M2000.xml as per screenshot below :
Collection Procedures
Supported file format is the command printout from Command Handling in Ericsson OSS. Here is a list of
supported command printout:
Note: Some commands may be applicable for certain version of the BSC only.
RLADP:SET=ALL;
DBTSP:TAB=AXEPARS;
RLGRP:CELL=ALL;
IOEXP;
RAEPP:ID=ALL;
RLCAP;
RLCDP:CELL=ALL;
RLDCP;
RLLSP;
RLOMP;
RLTYP;
RLHBP;
RLBDP:CELL=ALL;
RLCFP:CELL=ALL;
RLCHP:CELL=ALL;
RLDTP:CELL=ALL;
RLGAP:CELL=ALL;
RLSTP:CELL=ALL;
DTSTP:DIP=ALL;
RLACP:CELL=ALL;
RLCRP:CELL=ALL;
RLCXP:CELL=ALL;
RLDEP:CELL=ALL;
RLDHP:CELL=ALL;
RLDMP:CELL=ALL;
Collection Procedures
RLDRP:CELL=ALL;
RLGSP:CELL=ALL;
RLHPP:CELL=ALL;
RLIMP:CELL=ALL;
RLLCP:CELL=ALL;
RLLDP:CELL=ALL;
RLLFP:CELL=ALL;
RLLHP:CELL=ALL;
RLLLP:CELL=ALL;
RLLPP:CELL=ALL;
RLMFP:CELL=ALL;
RLPBP:CELL=ALL;
RLPDP:CELL=ALL;
RLSBP:CELL=ALL;
RLSMP:CELL=ALL;
RLSSP:CELL=ALL;
RLSUP:CELL=ALL;
RLUMP:CELL=ALL;
RRGBP;
RLBCP:CELL=ALL;
RLCPP:CELL=ALL;
RLLOP:CELL=ALL;
RLPCP:CELL=ALL;
RLCPP:CELL=ALL,EXT;
RLDEP:CELL=ALL,EXT;
RLLHP:CELL=ALL,EXT;
RLLOP:CELL=ALL,EXT;
RLDEP:CELL=ALL,EXT,UTRAN;
RLNRP:CELL=ALL,UTRAN;
RLGNP:CELL=ALL;
RLNRP:CELL=ALL;
RLLBP;
SAOSP;
SAAEP:SAE=ALL;
SAAEP:SAE=1153;
SAAEP:SAE=298;
SAAEP:SAE=299;
SAAEP:BLOCK=RQCD,SAE=522;
SAAEP:BLOCK=RQCD,SAE=523;
RLAPP:CELL=ALL;
RLIHP:CELL=ALL;
RLLUP:CELL=ALL;
RLOLP:CELL=ALL;
RLSLP:CELL=ALL;
RLTDP:MSC=ALL
RRTPP:TRAPOOL=ALL;
RLLPP:CELL=ALL;
RXMOP:MOTY=RXOTG;
RXTCP:MOTY=RXOTG;
RXMOP:MOTY=RXOTRX;
CACLP;
Collection Procedures
Supported file format is MO Shell from the Ericsson OSS. Following are the supported command printout:
Note: For new release of Ericsson RNC the supported file format is extracted from MO Shell (kget). The command
is ‘lt all; kget all’
RncFunction
UeRc
UeRcTrCh
UeRcRab
UeRcEdchFlow
UeRcPhyChEdch
WcdmaCarrier
UtranCell
Pch
UtranRelation
GsmRelation
Fach
Hsdsch
Eul
Rach
IubLink
NbapCommon
NodeSynch
NbapDedicated
IubEdch
Handover
DchFrameSynch
Ura
RncModule
Rcs
SecurityHandling
IurLink
WcdmaCarrier
ExternalUtranCell
CchFrameSynch
UeRrcType
UePositioning
PositioningServiceClass
AgpsPositioning
RttPositioning
ExternalGsmNetwork
ExternalGsmCell
LocationArea
ServiceArea
RoutingArea
Collection Procedures
Panging
UtranNetwork
PowerControl
PlmnIdentityGroup
Sid
SasPositioning
ChannelSwitching
UeMeasControl
Supported file format is the BulkCM Export from the Ericsson OSS. By default Ericsson OSS will automatically
export the Bulk CM for whole network daily. In order to reduce the output file, user can exclude the Transport
Network information which is not required.
NodeBFunction
vsDataNodeBFunction\
vsDataSector
vsDataCarrier
vsDataRbsLocalCell
vsDataSectorAntenna
vsDataAntennaBranch
vsDataAntFeederCable
Collection Procedures
vsDataAuxPlugInUnit
RNCFunction
attributes
VsDataContainer
UtranCell
IubLink
Collection Procedures
2. OSS Common Explorer will appear on the screen as shown in the figure below. At Topology Tab, select the
Root node from the network tree. Then, right click and select ‘Export.’ option from the context menu.
Collection Procedures
3. After clicking on ‘Export.’ option, Bulk CM Export dialog box will appear as shown in the figure below.
Tick to select Radio Network only as a filter details option and click Export button.
Collection Procedures
Collection Procedures
Supported file format is the exported Comma Delimited file at the OMC. There are separate files for Cell and
Neighbor parameter. For the neighbor parameters file the GSM Neighbors Export and Utran Relation Export are
in one single file.
Collection Procedures
Collection Procedures
Collection Procedures
Collection Procedures
2. CHR Log
The CHRs are generated automatically and stored under the BAM in the following path:
- RNC R10 /bam/versiona/loaddata/famlogfmt for R10
- RAN R11 /bam/common/fam/famlogfmt
- RAN R12 & R13 /bam/common/fam/famlogfmt/pchr
The PCHR log will have either UCHR or PCHR word in the filenames e.g.
- RNC R10 RNC0101_02Log20110404000002_20110404010109.log.zip
- RAN R11 BSC0121_[UCHR]02Log20111010231746(DST)_20111010232743(DST).log.zip
- RAN R12 & R13 BSC0121_[PCHR]02Log20111010231746(DST)_20111010232743(DST).log.zip
Important: For R11 and above, please ensure that the file name has ‘UCHR’ or ‘PCHR’. File with
‘CHR’ string alone does contain the performance call log and not supported in Xeus Pro.
The CHRs are generated automatically and stored under the BAM in the following path:
RAN R12 & R13 /bam/common/fam/famlogfmt/pchr
The PCHR log will have either UCHR or PCHR word in the filenames e.g.
RAN R12 & R13 BSC0121_[PCHR]02Log20111010231746(DST)_20111010232743(DST).log.zip
If one of the fields is not enabled in the CHRs, use the following command to enable it:
1. In the LMT tool, execute the command SET CHRRNCCTRL (R10) or SET UCHRCTRL (R11) in the Command Input
field.
2. Click the “SELECT ALL” check box in the Type option drop down lists.
Collection Procedures
Huawei R10
SET CHRRNCCTRL:STATETYPE=ABNORMAL_ONLY-1&NORMAL_ONLY-1, DOMAINTYPE=CS_ONLY-1&PS_ONLY-1, FLOWTYPE=CONN_SETUP-1&RAB-1&DCCC-
1&SHO-1&HHO-1&SYS_HO_OUT-1&RRC_RELEASE-1&STAT-1&NET_OPT-1, RRCCAUSE=ORIGINATING_CONVERSATIONAL_CALL-
1&ORIGINATING_STREAMING_CALL-1&ORIGINATING_INTERACTIVE_CALL-1&ORIGINATING_BACKGROUND_CALL-
1&ORIGINATING_SUBSCRIBED_TRAFFIC_CALL-1&TERMNT_CONVERSATIONAL_CALL-1&TERMNT_STREAMING_CALL-1&TERMNT_INTERACTIVE_CALL-
1&TERMNT_BACKGROUND_CALL-1&EMERGENCY_CALL-1&INTER_RAT_CELL_RESELECTION-1&INTER_RAT_CELL_CHG_ORDER-1®ISTRATION-
1&DETACH-1&ORIGINATING_HIGH_PRIOR_SIG-1&ORIGINATING_LOW_PRIOR_SIG-1&CALL_RE_ESTAB-1&TERMNT_HIGH_PRIOR_SIG-
1&TERMNT_LOW_PRIOR_SIG-1&TERMNT_CAUSE_UNKNOWN-1&MBMS_RECEPTION-1&MBMS_PTP_RB_REQ-1;
Collection Procedures
2) After capturing the log, you can export the log from eNodeB by executing the MML commands as the
following:
Collection Procedures
Collection Procedures
• Trace Depth
o Set to High
• Message Type
o Select ALL messages
Collection Procedures
Site Data
It is advisable for the users to import the site data by XIF/TEMS Cel-file/ MCOM file format first before the
importing of the Ericsson WCDMA OSS Bulk CM XML file or Ericsson RNC MOSHELL KGET log.
The table below shows some of the mandatory fields in creating a XIF format site data:
Note: Xeus Pro does not accept two records with SAME Cell Id. Any duplicate
cell Id will be renamed with additional suffix e.g. G1001A_1.
Mandatory field
Mandatory field
Mandatory field
Mandatory field
Note: RncId-Cid pair allows matching of WCDMA Cell network data to the site
data in Xeus Pro database
Note: RncId-Cid pair allows matching of WCDMA Cell network data to the site
data in Xeus Pro database
Collection Procedures
Collection Procedures
Collection Procedures
9. Select the UE Fraction for the percentage of mobile that will be recorded.
10. Input the schedule for the profile recording. It is advisable to make sure there is no others running
recording on the planned schedule.
11. Once complete, the collected GPEH files will be located in
“/var/opt/ericsson/nms_umts_pms_seg/segment1/GPEH/” folder.
Collection Procedures
1. Select Performance > Initiate data Collection > WCDMA/LTE RAN Measurements to start the
WCDMA/LTE RAN Measurement tool.
Collection Procedures
Collection Procedures
3. Add GPEH subscription profile wizard will appear on the screen as shown in the figure below. Select the
required recording type. (GPEH, CTR or UETR) Click Next button to proceed to the next step.
Collection Procedures
4. Type in the Profile name and click Next button to proceed to the next step.
Collection Procedures
5. Select RNC network elements should be observed and click Next button to proceed to the next step.
Collection Procedures
6. Select the required RNC you would like to collect and click Next button to proceed to the next step.
Collection Procedures
7. Select the required Utran Cells for recording and click Next button to proceed to the next step.
Collection Procedures
8. Select the events for the GPEH recording and click Next button to proceed to the next step. Please refer
to section 3.4.1 for GPEH Recording Scenarios for the required events on different analysis scenarios.
Collection Procedures
9. Select the UE Fraction (Percentage of mobile that will be recorded) and click Next button to proceed to
the next step.
Collection Procedures
Collection Procedures
11. Monitor the progress at Profile display tab > General performance even handling profiles.
Following table shows the different analysis scenarios in Xeus Pro 5 and the recommended data collection
configuration.
Analysis Type Recommended GPEH Event to be collected Cell Set Recording
Setting
Problem Cells detail GPEH Internal Event Problem cells only. gpehDataLevel =
analysis such as INTERNAL_ADMISSION_CONTROL_RESPONSE Not more than 1 (ALL DATA)
troubleshooting of INTERNAL_CALL_REESTABLISHMENT 10% of total RNC
dropped call, INTERNAL_CALL_SETUP_FAIL limit Ue_Fraction =
blocked call and INTERNAL_CHANNEL_SWITCHING 500
Throughput. User INTERNAL_CMODE_ACTIVATE
needs to analyze INTERNAL_CMODE_DEACTIVATE
call messages with INTERNAL_CNHHO_EXECUTION_ACTIVE
message details. INTERNAL_FAILED_HSDSCH_CELL_CHANGE
INTERNAL_FAILED_TRANSITION_TO_DCH
INTERNAL_HSDSCH_CELL_SELECTION_NO_CELL_SELE
CTED
INTERNAL_IFHO_EXECUTION_ACTIVE
INTERNAL_IMSI
INTERNAL_IRAT_HO_CC_EVALUATION
Collection Procedures
INTERNAL_IRAT_HO_CC_EXECUTION
INTERNAL_MEASUREMENT_HANDLING_EXECUTION
INTERNAL_PACKET_DEDICATED_ THROUGHPUT
INTERNAL_RAB_ESTABLISHMENT
INTERNAL_RAB_RELEASE
INTERNAL_RADIO_QUALITY_MEASUREMENTS_UEH
INTERNAL_SOFT_HANDOVER_EXECUTION
INTERNAL_SOHO_DS_MISSING_NEIGHBOUR
INTERNAL_SOHO_DS_UNMONITORED_NEIGHBOUR
INTERNAL_SUCCESSFUL_HSDSCH_CELL_CHANGE
INTERNAL_SUCCESSFUL_HSDSCH_CELL_SELECTION_
NEW_ACTIVE_SET
INTERNAL_SUCCESSFUL_HSDSCH_CELL_SELECTION_
OLD_ACTIVE_SET
INTERNAL_SUCCESSFUL_TRANSITION_TO_DCH
INTERNAL_SYSTEM_BLOCK
INTERNAL_SYSTEM_RELEASE
INTERNAL_SYSTEM_UTILIZATION
INTERNAL_OUT_HARD_HANDOVER_FAILURE
INTERNAL_OUT_HARD_HANDOVER_SUCCESS
RRC Event
RRC_CELL_CHANGE_ORDER_FROM_UTRAN
RRC_CELL_CHANGE_ORDER_FROM_UTRAN_FAILURE
RRC_CONNECTION_REJECT
RRC_CONNECTION_RELEASE
RRC_CONNECTION_REQUEST
RRC_CONNECTION_SETUP_COMPLETE
RRC_DOWNLINK_DIRECT_TRANSFER
RRC_HANDOVER_FROM_UTRAN_COMMAND
RRC_HANDOVER_FROM_UTRAN_FAILURE
RRC_INITIAL_DIRECT_TRANSFER
RRC_MEASUREMENT_CONTROL
RRC_MEASUREMENT_REPORT
RRC_UPLINK_DIRECT_TRANSFER
RANAP Event
RANAP_COMMON_ID
RANAP_IU_RELEASE_COMMAND
RANAP_IU_RELEASE_REQUEST
RANAP_RELOCATION_COMMAND
RANAP_RELOCATION_PREPARATION_FAILURE
Collection Procedures
NBAP Event
NBAP_RADIO_LINK_SETUP_REQUEST
NBAP Event
NBAP_RADIO_LINK_SETUP_REQUEST
RANAP Event
RANAP_COMMON_ID
Collection Procedures
RRC Event
RRC_CONNECTION_RELEASE
RRC_CONNECTION_REQUEST
NBAP Event
NBAP_RADIO_LINK_SETUP_REQUEST
RANAP Event
RANAP_COMMON_ID
Phone Profiling GPEH Internal Event Whole RNC gpehDataLevel =
INTERNAL_ADMISSION_CONTROL_RESPONSE 1 (ALL DATA)
INTERNAL_CALL_REESTABLISHMENT
INTERNAL_CALL_SETUP_FAIL Ue_Fraction =
INTERNAL_CNHHO_EXECUTION_ACTIVE 500
INTERNAL_FAILED_HSDSCH_CELL_CHANGE
INTERNAL_FAILED_TRANSITION_TO_DCH
INTERNAL_IFHO_EXECUTION_ACTIVE
INTERNAL_IRAT_HO_CC_EXECUTION
INTERNAL_MEASUREMENT_HANDLING_EXECUTION
INTERNAL_RAB_ESTABLISHMENT
INTERNAL_RADIO_QUALITY_MEASUREMENTS_UEH
INTERNAL_SOFT_HANDOVER_EXECUTION
INTERNAL_SOHO_DS_MISSING_NEIGHBOUR
INTERNAL_SOHO_DS_UNMONITORED_NEIGHBOUR
INTERNAL_SYSTEM_BLOCK
INTERNAL_SYSTEM_RELEASE
RRC Event
RRC_CONNECTION_RELEASE
RRC_CONNECTION_REQUEST
RRC_DOWNLINK_DIRECT_TRANSFER
RRC_INITIAL_DIRECT_TRANSFER (Mandatory)
RRC_UPLINK_DIRECT_TRANSFER (Mandatory)
Collection Procedures
RANAP Event
RANAP_COMMON_ID
RANAP_IU_RELEASE_COMMAND
RANAP_IU_RELEASE_REQUEST
NBAP Event
NBAP_RADIO_LINK_SETUP_REQUEST
NBAP Event
NBAP_CELL_SETUP_REQUEST
RANAP Event
RANAP_COMMON_ID
RANAP_IU_RELEASE_COMMAND
RANAP_IU_RELEASE_REQUEST
Collection Procedures
Here is a table of events and the protocol required to be collected. The events that are available for CTR and
UETR respectively are marked by a tick:
Collection Procedures
INTERNAL_PER_UETR_CELL_TRAFFIC_REPORT INTERNAL
INTERNAL_PER_UETR_RADIO_CELL_MEASUREMENT INTERNAL
INTERNAL_PER_UETR_RADIO_UE_MEASUREMENT INTERNAL
INTERNAL_PER_UETR_RADIO_UTILIZATION INTERNAL
INTERNAL_PER_UETR_UE_RB_TRAFFIC_REP INTERNAL
INTERNAL_PER_UETR_UE_TRAFFIC_REP INTERNAL
INTERNAL_PROC_ERAB_RELEASE INTERNAL
INTERNAL_PROC_ERAB_SETUP INTERNAL
INTERNAL_PROC_HO_EXEC_S1_IN INTERNAL
INTERNAL_PROC_HO_EXEC_S1_OUT INTERNAL
INTERNAL_PROC_HO_EXEC_X2_IN INTERNAL
INTERNAL_PROC_HO_EXEC_X2_OUT INTERNAL
INTERNAL_PROC_INITIAL_CTXT_SETUP INTERNAL
INTERNAL_PROC_RRC_CONN_SETUP INTERNAL
INTERNAL_PROC_S1_SETUP INTERNAL
INTERNAL_PROC_S1_SIG_CONN_SETUP INTERNAL
INTERNAL_PROC_UE_CTXT_RELEASE INTERNAL
RRC_MEASUREMENT_REPORT RRC
RRC_RRC_CONNECTION_RECONFIGURATION RRC
RRC_RRC_CONNECTION_RECONFIGURATION_COMPLETE RRC
RRC_RRC_CONNECTION_RELEASE RRC
RRC_RRC_CONNECTION_REQUEST RRC
RRC_RRC_CONNECTION_SETUP RRC
RRC_RRC_CONNECTION_SETUP_COMPLETE RRC
S1_DOWNLINK_NAS_TRANSPORT S1
S1_ERAB_RELEASE_COMMAND S1
S1_ERAB_RELEASE_REQUEST S1
S1_ERAB_SETUP_REQUEST S1
S1_ERAB_SETUP_RESPONSE S1
S1_ERAB_RELEASE_INDICATION S1
S1_HANDOVER_COMMAND S1
S1_HANDOVER_REQUEST S1
S1_HANDOVER_REQUIRED S1
S1_INITIAL_CONTEXT_SETUP_REQUEST S1
S1_INITIAL_CONTEXT_SETUP_RESPONSE S1
S1_INITIAL_UE_MESSAGE S1
S1_UE_CONTEXT_RELEASE_COMMAND S1
S1_UE_CONTEXT_RELEASE_REQUEST S1
Collection Procedures
S1_UPLINK_NAS_TRANSPORT S1
X2_HANDOVER_REQUEST X2
X2_HANDOVER_REQUEST_ACKNOWLEDGE X2
1. On the Performance menu of the OSS Network Explorer window, click Initiate data Collection then click
RAN Measurements.
2. To create a new Subscription Profile select Add profile from the Administration menu, then the Add
subscription profile wizard will appear. There follows a series of steps at the end of which a new
Subscription Profile will be created. Move between the steps using the Next and Previous buttons.
Collection Procedures
Collection Procedures
Collection Procedures
12. At the LTE Cell Trace Profiles tab, select the newly created profile, Right click on the UE ID Mapping label
and select “Enable UE ID mapping”
The Ericsson LTE MME EBM Trace file correlates with Ericsson LTE Call Trace. The aim is to provide IMSI
information to the calls logged in the LTE Call Trace. Its format is *_ebs.* where the extension is a sequence
number.
Example:
A20110207.1115-0600-20110207.1130-0600_1_ebs.235
A20110207.1130-0600-20110207.1145-0600_1_ebs.236
Collection Procedures
Event Name
L_TAU
L_SERVICE_REQUEST
L_ATTACH
L_DETACH
Site Data
Users need to import the site data by XIF/TEMS Cel-file/ MCOM file format first before the importing of the Nokia
WCDMA RAML XML file.
The table below shows some of the mandatory fields in creating a XIF format site data:
Note: Xeus Pro does not accept two records with SAME Cell Id. Any duplicate
cells Id will be renamed with additional suffix e.g. G1001A_1.
Mandatory field
Mandatory field
Mandatory field
Mandatory field
Collection Procedures
Note: RncId-Cid pair allows matching of WCDMA Cell network data to the site
data in Xeus Pro database
Note: RncId-Cid pair allows matching of WCDMA Cell network data to the site
data in Xeus Pro database
Collection Procedures
Collection Procedures